Soil & Treatment 465 Inland Way 2012 ~ PROJECT NO: 0257-0015
/ LAB NO: 71588-A
Ellis Asseclatesinc. DATE TESTED: 06/12/2012
7064 Davis Creek Road REPORT NO: 1-0002
Jacksonville,FI 32256 DATE: 06/19/2012
(904)880-0960 Office
(904)880-0970 Fax
REPORT OF: RESIDENTIAL IN-PLACE DENSITY TEST
PROJECT: 465 Inland Way
Atlantic Beach, Duval Cty, FL
ATTENTION: Mr Gary McCumber
REPORTED TO: McCumber Homes of Ponte Vedra Inc
Suite 211
100 East Town Place
St Augustine, FL 32092
TEST RESULTS Page 1 of 1
General Location: Building Area
Specific Location: House Pad
Course: Fill
Test Dry Percent
Test Depth Percent Density Proctor Spec Proctor
No. (in) Location Moisture (pcf) Number No. Density Pass/Fail
1 12 Southeast Corner 12.6 98.6 71588 1 98 Pass
2 12 Center 13.7 99.4 71588 1 99 Pass
3 12 Northwest Corner 13.2 97.9 71588 1 97 Pass
Proctor Proctor Optimum Maximum LBR
No Date Moisture DryDensity Value Description Location
71588 06/12/2012 16.1 100.8 N/A Gray Brown Fine SAND w/Silt House Lot
Specification
Specification No. Compaction,%
1 95 Min
Date Received:06/12/2012 Date Tested: 06/12/2012
Gauge No.: 34218
Test Methods: ASTM D6938-08a
Orig:McCumber Homes of Ponte Vedra Inc Attm Mr Gary McCumber Respectfully Submitted,
(1-ec copy)
Ellis&Associates, Inc.
This document has been digitally signed in accordance
with Florida Statute 611315-23.003 on 0710112012.
Joseph M.Champion,P.E.
Technician:Adam Jackson Director,CMT and Inspection
Licensed,Florida No.69135
(APK)
THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S)TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES,NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED.THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.
REPORT CREATED BY ElmTree SYSTEM
PROJECT NO: 0257-0015
LAB NO: 71588
ElImAssociatesinc. DATE TESTED: 06/12/2012
7064 Davis Creek Road REPORT NO: 1-0001
Jacksonville,FI 32256
(904)880-0960 Office DATE: 06/14/2012
(904)880-0970 Fax
REPORT OF: SOIL PROCTOR
PROJECT: 465 Inland Way
Atlantic Beach, Duval Cty, FL
ATTENTION: Mr Gary McCumber
REPORTED TO: McCumber Homes of Ponte Vedra Inc
Suite 211
100 East Town Place
St Augustine, FL 32092
TEST RESULTS Page 1 of 1
Sample Location: House Lot
Material: Fill
%Moisture _Dry Density Lbs./Cu.Ft.
100%saturation line for SG=2.65 Estimated 17.5 99.70
1616.6 100.7
--------------------------------- --- 15.5 100.7
------------------------------------ 14.5 100.1
-------------------------------------
-------------------------------------
los -
------------------------------------ 16.1 Optimum 100.8 Maximum
CIL I ------------------------------------- Color/Description:Gray Brown Fine SAND
Vj ------------------------------------- w/Silt
C
Q) -------------------------------------
O
-------------------------------------
O too ------ ------------- -------
------------------------- -----------
--------------------------- ---------
9s
13 M 15 16 17 18 19 20
Moisture Content.percent
Desc of Rammer:Mechanical Date Received: 06/12/2012
Preparation Method: Dry Date Tested: 06/13/2012
Remarks:
Test Method (As Applicable):ASTM D-1557
Orig:McCumber Homes of Ponte Vedra Inc Attn:Mr Gary McCumber Respectfully Submitted,
(1-ec copy)
Ellis &Associates, Inc.
This document has been digitally signed in accordance
with Florida Statute 61G15-23.003 on 06/15/2012.
Nemer(Nick)Y.Oweis,P.E.
Technician:Adam Jackson Chief Engineer
(APK) Licensed,Florida No.44755
THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S)TESTED ANO/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES,NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED.THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.
REPORT CREATED BY ElmTree SYSTEM
Notice of Treatment
Applicator: Florida Pest Control & Chemical Co. (www flapest com)
Address:
City a ( 3 Z7..J Phone
Site Location: Subdivision t ? )A_J
Lot # Block# Permit
Address
Product used Active Ingredient % Concentration
Cl Premise Imidacloprid 0.1%
❑ Termidor Fipronil 0.12%
❑ Bora-Care Disodium Octaborate Tetrahydrate 23.0%
Type treatment: Soil ❑ Wood
Area Treated Square feet Linear feet Gallons Applied
As per Florida Building Code 104.2.6— If soil chemical barrier,method for
termite prevention is used, final exterior treatment shall be completed prior
to final building approval.
If this notice is for the final exterior treatment, initial this line
Z 7i.'/0 M (K / (j,A
to Time Print Technician's Name
Remarks: Ra
Applicator-White Permit File Canary Permit Holder- Pink
10105
�C
Notice of Treatment
Applicator: Florida Pest Control & Chemical L2-- l—www-Ya est.com
Address: Z , 2c7 f r�
City Phon o- S �
Site Location: Subdivision
Lot # Block# Permit # - 7
Address , W AZ
Product used _Active Ingredient % Concentration
Premise Imidacloprid
0.1%
❑ Termidor Fipronil
0.12%
Q Bora-Care Disodium Octaborate Tetrahydrate 23.0%
Type treatment: U Soil ❑ Wood
Area Treated Square feet Linear feet
1 � Gallons Applied
�7�
As per Florida Building Code 104.2.6-If soil chemical barrier method for
termite prevention is used, final exterior treatment shall be completed prior
to final building approval.
If this notice is for the final exterior treatment, initial this line
Dae
44
Time Print Technician's Name
Remarks:
Applicator- White Permit File- Canary Permit Holder-Pink
10105