Loading...
Permit HVAC 1338 Violet St 2012 CITY OF ATLANTIC BEACH .� 800 SEMINOLE ROAD J s3 ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 12-00000650 Date 10/17/12 Property Address . . . . . . 1338 VIOLET ST Application type description SINGLE FAMILY ATTACHED DWELLING Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 75000 ---------------------------------------------------------------------------- Application desc single fam attached ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ BEACHES HABITAT FOR HUMANITY BEACHES HABITAT 1671 FRANCIS AVE. 1671 FRANCIS AVENUE ATLANTIC BEACH FL 32233 ATLANTIC BEACH FL 32233 (904) 241-1222 (904) 241-1222 --- Structure Information 000 000 NEW SINGLE FAMILY ATTACHED DWELLING Construction Type . . . . . TYPE 5-A Occupancy Type . . . . . . RESIDENTIAL Flood Zone . . . . . . . . ZONE X ---------------------------------------------------------------------------- Permit MECHANICAL HVAC PERMIT Additional desc . . Sub Contractor . . FLORIDA AIR SERVICE & ENG.LLC Permit Fee . . . . 91 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 4/15/13 ---------------------------------------------------------------------------- Special Notes and Comments 2010 FLORIDA BUILDING CODE, 2008 NATIONAL ELECTRIC CODE FOR AN APPROVED FINAL MECHANICAL A/C INSPECTION, A STICKER SHALL BE INSTALLED ON THE AHU TO VERIFY THAT DUCTS HAVE BEEN SEALED, A CERTIFICATION SHALL BE ON SIGHT FOR THE INSPECTOR STATING THAT THE A/C SYSTEM PASSED THE "AIR BLAST INSPECTION" FROM AND INDEPENDENT TESTING AGENCY. *SUBMIT "CERTIFICATE OF COMPLIANCE" BY A LICENSED PEST CONTROL COMPANY PRIOR TO C.O. WINDOW AND DOOR INSPECTION: *INSTALLATION INSTUCTIONS REQUIRED *ALL STICKERS ARE TO REMAIN ON THE WINDOWS *PROVIDE ACCESS TO ALL WINDOWS TO INSPECT FASTENERS Avoid damage to underground water/sewer utilities . Verify vertical and horizontal location of utilities . Hand dig if necessary. If field coordination is needed, call 247-5834 . Ensure all meter boxes, sewer cleanouts and valve covers are set to grade and visible. A sewer cleanout must be installed at the property line. PERMIT THE FLORIDA BUILDING CODES. CITY OF ATLANTIC BEACH } 800 SEMINOLE ROAD J m " =y ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Page 2 Application Number . . . . . 12-00000650 Date 10/17/12 ---------------------------------------------------------------------------- Special Notes and Comments metal lid. Cleanout to be set to grade and visible. Any utility cuts in the road must be repaired using COJ Standard Detail Case X and must be overlaid 10 feet in each direction from the center of the cut . Repair must be shown on the plans . Full right-of-way restoration, including sod, is required. Roll off container company must be on City approved list and container cannot be placed on City right-of-way. (Approved: Advanced Disposal, Realco, Shappelle ' s and Waste Management) Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities . Contact Public Works (247-5834) for Erosion and Sediment Control Inspection prior to start of construction. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 91 . 00 91 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 95 . 00 95 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247-5826 Fax (904) 247-5845 . 4T013 ADDRESS: V 10 c,,C-T Sr PERMIT# PROJECT VALUE $ ARI# REQUIRED NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity ( Tons Per Unit Heat: Unit Quantity— I BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps - #Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name _ / Phone Number Mechanical Company t'�0��4 h�rL �� Office Phone �L1 Fax �tl Q.- Co. Address: ��� +� �v -I De City JOAK ✓e-AM State (4--Zip �L— License Holder(Prin#: M ' 8t-71- State Certification/Registration# :fA c i6`tjQj _ X09'. Notarized Signature �l�afise HA SEE t21278S1Vand subsc ' ed before me this i day of 0cF- 20 i� //' '•.';fin F .� /z Z,%,��t►►„4 `` Ature of Notary P lic