Loading...
Permit HVAC 1199 Beach Ave 2012 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 12-00001586 Date 10/29/12 Property Address . . . . . . 1199 BEACH AVE Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ DICKINSON MAXWELL K TRUST ETAL ONE HOUR AIR 1199 BEACH AVE 1015 ATLANTIC BLVD #249 ATLANTIC BEACH FL 32233 ATLANTIC BEACH FL 32233 (904) 222-8482 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 91 . 00 Plan Check Fee . 00 Issue Date . . . . valuation . . . . 0 Expiration Date . . 4/27/13 -----------------------------------------------I---------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 91 . 00 91 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 95 . 00 95 . 00 . 00 . 00 PERMIT IS APPROVED ONLV IN ACCORDANCE WITH ALL CITV OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247-5826 Fax (904) 247-5845 JOBADDRESS:_112? &e PERMIT# PROJECTVALUE $ (OS60. ' ARI# '12 V,,5 Y73 RE Q UIAMD NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating I Duct Systems: Total CFM REQU1RkD-- FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty_ Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's 4 Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provislo )f any other state or local law regulation construction or the performance of construction. Property Owners Name -U)e LL Oil Cc, /1)50/L) Phone Number 2 qq— 2S-2 Mechanical Company a )p Office Phone29[3107Fax2L1?-S-S-26 Co. Address: jt2jq Cit *VI-X Gc tl- State FL Zip 3Z-77-7 License Holder(Print): (1,Q/6 F4)v X�/ S rtifica 'on/Registration Notarized Signature of License Holder Sworn and subscribed h/fo', e this d f CT 2012 Signature of Notary Pub wrightsoft Project Summary Job: 120544 Date: 10/25/2012 Entire House By: CRAIG EDDY ONE HOUR AIR 1198 MAYPORT RD#1,ATLANTIC BEACH,FL 32233 Phone:904-241-3107 Fax:904-247-5526 License:CAC18144�0 For: MAXWELL DICKINSON 1199 BEACH AVE,ATLANTIC BEACH, FL 32233 Phone: 904-249-2528 Notes: Desian Information Weather: Jacksonville/Craig, FL, US Winter Design Conditions Summer Design Conditions Outside db 35 'F Outside db Inside db 70 *F Inside db 91 *F Design TD 75 *F 35 *F Design TD 16 *F Daily range M Relative humidity" 50 % Moisture difference 53 gr1lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 18507 Btuh Structure i i 17763 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh 0 Btuh Equipment load 18507 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 17763 Btuh Method Simplified Latent Co oling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2024 Btuh Ducts 0 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft� 800 800 Equipment latent load 2024 Btuh Volume(M 6400 6400 Air changes/hour 0.61 0.32 Equipment total load 19788 Btuh Equiv.AVF(cfm) 65 34 Req.total capacit y! at 0.75 SHR 2.0 ton Heating Equipment Summary Cooling Equipment Summary Make GOODMAN Make GOODMAN Trade ONE HOUR AIR Trade ONE HOUR AIR Model SSZ140241 Cond SSZ140241 AHRI ref 4248573 Coil ASPF183016 AHRI ref 4248573 Efficiency 0 HSPF Efficiency Heating input 15 SEER Sensible cooling 17700 Btuh Heating output 0 Btu h @ 47-F Latent cooling 5900 Btuh Temperature rise 0 oF Total cooling 23600 Btuh Actual air flow 809 cfm Actual air flow Air flow factor 809 cfm 0.044 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat Load sensible heat ratio 0.90 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wright$01V Right-Suites universal 2012 12.1.00 Right Ja Mobile 2012-Oct-25 14:51:40 C:\WNDOWS\TEMP\wstmp\30562c5a-fc27-4fd8-9Oc8-cbbOOb9885e7.rup Calc=MJ8 Front Door faces: E Page 1 This combination qualifies for a Federal Energy Efficiency Tax Credit when placed in service WILN CERTIFIEDTM between Feb 17, 2009 and Dec 31, 2011. www.ahridirectory.org ) Certificate of Product Ratings AHRI Certified Reference Number: 4248573 Date: 10/29/2012 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: SSZ140241A* Indoor Unit Model Number: ASPF183016E*+TXV Manufacturer: GOODMAN MANUFACTURING CO., LP. Trade/Brand name: GOODMAN,JANITROL,AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR CONDITIONING AND HEATING, ENERGI AIR Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP. Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity(Btuh): 23600 EER Rating (Cooling): 12.50 SEER Rating (Cooling): 15.00 Heating Capacity(Btuh)@ 47 F: 22000 Region IV HSPF Rating (Heating): 8.60 Heating Capacity(Btuh)@ 17 F: 13500 Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized afteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of Z Certificate may not in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at wwmahridirectory.org, Air-Conditioning,Heating, click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on and Refrigeration Institute which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. @2012 Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO.: 129959945408347688