Permit HVAC 1199 Beach Ave 2012 CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 12-00001586 Date 10/29/12
Property Address . . . . . . 1199 BEACH AVE
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
1 cu 1 ahu
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
DICKINSON MAXWELL K TRUST ETAL ONE HOUR AIR
1199 BEACH AVE 1015 ATLANTIC BLVD #249
ATLANTIC BEACH FL 32233 ATLANTIC BEACH FL 32233
(904) 222-8482
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee . . . . 91 . 00 Plan Check Fee . 00
Issue Date . . . . valuation . . . . 0
Expiration Date . . 4/27/13
-----------------------------------------------I----------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 91 . 00 91 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 95 . 00 95 . 00 . 00 . 00
PERMIT IS APPROVED ONLV IN ACCORDANCE WITH ALL CITV OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph (904) 247-5826 Fax (904) 247-5845
JOBADDRESS:_112? &e PERMIT#
PROJECTVALUE $ (OS60. ' ARI# '12 V,,5 Y73
RE Q UIAMD
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating I
Duct Systems: Total CFM REQU1RkD--
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty_ Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
4 Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER:
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified
or not. The permit does not give authority to violate the provislo )f any other state or local law regulation construction or the performance of construction.
Property Owners Name -U)e LL Oil Cc, /1)50/L) Phone Number 2 qq— 2S-2
Mechanical Company a )p Office Phone29[3107Fax2L1?-S-S-26
Co. Address: jt2jq Cit *VI-X Gc tl- State FL Zip 3Z-77-7
License Holder(Print): (1,Q/6 F4)v X�/ S rtifica 'on/Registration
Notarized Signature of License Holder
Sworn and subscribed h/fo', e this d f CT 2012
Signature of Notary Pub
wrightsoft Project Summary Job: 120544
Date: 10/25/2012
Entire House By: CRAIG EDDY
ONE HOUR AIR
1198 MAYPORT RD#1,ATLANTIC BEACH,FL 32233 Phone:904-241-3107 Fax:904-247-5526 License:CAC18144�0
For: MAXWELL DICKINSON
1199 BEACH AVE,ATLANTIC BEACH, FL 32233
Phone: 904-249-2528
Notes:
Desian Information
Weather: Jacksonville/Craig, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 35 'F Outside db
Inside db 70 *F Inside db 91 *F
Design TD 75 *F
35 *F Design TD
16 *F
Daily range M
Relative humidity" 50 %
Moisture difference 53 gr1lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 18507 Btuh Structure i
i 17763 Btuh
Ducts 0 Btuh Ducts 0 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh 0 Btuh
Equipment load 18507 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 17763 Btuh
Method Simplified Latent Co oling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 2024 Btuh
Ducts 0 Btuh
Heating Cooling Central vent(0 cfm) 0 Btuh
Area(ft� 800 800 Equipment latent load 2024 Btuh
Volume(M 6400 6400
Air changes/hour 0.61 0.32 Equipment total load 19788 Btuh
Equiv.AVF(cfm) 65 34 Req.total capacit y! at 0.75 SHR 2.0 ton
Heating Equipment Summary Cooling Equipment Summary
Make GOODMAN Make GOODMAN
Trade ONE HOUR AIR Trade ONE HOUR AIR
Model SSZ140241 Cond SSZ140241
AHRI ref 4248573 Coil ASPF183016
AHRI ref 4248573
Efficiency 0 HSPF Efficiency
Heating input 15 SEER
Sensible cooling 17700 Btuh
Heating output 0 Btu h @ 47-F Latent cooling 5900 Btuh
Temperature rise 0 oF Total cooling 23600 Btuh
Actual air flow 809 cfm Actual air flow
Air flow factor 809 cfm
0.044 cfm/Btuh Air flow factor 0.046 cfm/Btuh
Static pressure 0 in H20 Static pressure 0 in H20
Space thermostat Load sensible heat ratio 0.90
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wright$01V Right-Suites universal 2012 12.1.00 Right Ja Mobile 2012-Oct-25 14:51:40
C:\WNDOWS\TEMP\wstmp\30562c5a-fc27-4fd8-9Oc8-cbbOOb9885e7.rup Calc=MJ8 Front Door faces: E Page 1
This combination qualifies for a Federal Energy
Efficiency Tax Credit when placed in service
WILN CERTIFIEDTM between Feb 17, 2009 and Dec 31, 2011.
www.ahridirectory.org )
Certificate of Product Ratings
AHRI Certified Reference Number: 4248573 Date: 10/29/2012
Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source
Outdoor Unit Model Number: SSZ140241A*
Indoor Unit Model Number: ASPF183016E*+TXV
Manufacturer: GOODMAN MANUFACTURING CO., LP.
Trade/Brand name: GOODMAN,JANITROL,AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR
CONDITIONING AND HEATING, ENERGI AIR
Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP.
Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third
party testing:
Cooling Capacity(Btuh): 23600
EER Rating (Cooling): 12.50
SEER Rating (Cooling): 15.00
Heating Capacity(Btuh)@ 47 F: 22000
Region IV HSPF Rating (Heating): 8.60
Heating Capacity(Btuh)@ 17 F: 13500
Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate.
DISCLAIMER
AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for,
the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the
unauthorized afteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org.
TERMS AND CONDITIONS
This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.
The contents of Z Certificate may not in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any
form or manner or by any means,except for the user's individual,personal and confidential reference.
CERTIFICATE VERIFICATION
The information for the model cited on this certificate can be verified at wwmahridirectory.org, Air-Conditioning,Heating,
click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on and Refrigeration Institute
which the certificate was issued,which is listed above,and the Certificate No.,which is listed below.
@2012 Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO.: 129959945408347688