Permit HVAC 1403 Linkside Dr 2012 CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
.........,
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 12-00001597 Date 10/29/12
Property Address . . . . . . 1403 LINKSIDE DR
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
1 cu 1 ahu
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
GARBRIEL WILLIAM J HUXHAM HEATING & AIR
1403 LINKSIDE DR 2101 FLORIDA BLVD.
ATLANTIC BEACH FL 32233 NEPTUNE BEACH FL 32266
(904) 246-6721
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee . . . . 95 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 4/27/13
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 95 . 00 95 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 99 . 00 99 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECEUNICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach,FL 32233
Ph(904)247-5826 Fax(904)247-5845
JOB ADDRESS: A/03 PIZ- PERMrr 0/0�
PROJECTVALUEs 3700— A"#�36 99-7
REQUIRED
NEW AIR CONDITIONING & BEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity, Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating—
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit oCS
Heat: Unit Quantity BTU's Per Unit 30,,000 Seer Rating Z-5
_13
Duct System: Total CFM REQUIRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty_ Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
# Water Heaters Solar Collection Systems
Tanks(gallons)
Wells
OTHER:
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby catify that I have read
this application and itnow the same to be true and coffect. All provisions of laws and ordinances governing this work will be complied with whether specified
or not The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
Property Owners Name f-�V�- Phone Number
Mechanical Company &z,46jn2 'Aik-e- Office Phone,9-Y(,,zQV/Fax
Co.Address: r9ja I city A Aed State r( Zip_3V4�6
License Holder(Print): 3�f-S 6:42,1 State Certification/Registration# <Q4-10575-15
Notarized Signature of License.1101d,
IV L G
, � 1� , �.i
subscri ed befo s of 20
�(114;�SION�or,95
of Notary Publi
�nd hru Ndn�l Public$"u
Project Summary Job: 102812
Date: Oct 28,2012
Entire House By: ERIN RODRIGUEZ
-Project Information
For: NORDAN
1403 LINKSIDE DRIVE,ATLANTIC BEACH, FL 32233
Notes: HUXHAM-A/C CHANGE OUT
Design Information
Weather: Jacksonville Mayport Naval, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 39 OF Outside db 92 OF
Inside db 68 OF Inside db 76 OF
Design TD 29 OF Design TD 16 OF
Daily range L
Relative humidity 50 %
Moisture difference 56 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 17202 Btuh Structure 16100 Btuh
Ducts 4173 Btuh Ducts 5764 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 21375 Btuh Use manufacturers data n
Rate/swing multiplier 0.97
Infiltration Equipment sensible load 21208 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces I (Average) Structure 1966 Btuh
Ducts 1445 Btuh
Heatin Cooling Central vent(0 cfm) 0 Btuh
Nea(ft� 1542 1542 Equipment latent load 3411 Btuh
Molume(fe) 12333 12333
Air changes/hour 0.48 0.20 Equipment total load 24619 Btuh
Equiv.AVF(cfrn) 98 41 Req.total capacity at 0.70 SHR 2.5 ton
Heating Equipment Summary Cooling Equipment Summary
Make GOODMAN Make GOODMAN
Trade Trade
Model GSZ130301A Cond GSZ130301A
AHRI ref no.5358271 Coil ARUF30B14A
AHRI ref no. 5358271
Efficiency 0.1 HSPF Efficiency 13 SEER
Heating input Sensible cooling 19600 Btuh
Heating output 27000 Blu h @ 47F Latent cooling 8400 Btuh
Temperature rise 28 OF Total cooling 28000 Btuh
Actual air flow 880 cfm Actual air flow 880 cfrn
Air flow factor 0.041 cfm/Btuh Air flow factor 0.040 cfm/Btuh
Static pressure 0 in H20 Static pressure 0 in H20
Space thermostat Load sensible heat ratio 0.87
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wrightsoft, Right-Sufte@ Untyersal 2012 12.0.07 RSU01508 2012-Od-28 23.40:22
rs%rin\DocumentslWtightsoftHVACITemplate\HUXHAM-NORDAN.rup Ca1c=MJ8 FrontDoorfaces: Page 1
...........
CERTIFIEDTM"'
www.ahridirectory.org -A)
Certificate of Product Ratings
AHRI Certified Reference Number: 5358271 Date: 10/29/2012
Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source
Outdoor Unit Model Number: GSZ130301A*
Indoor Unit Model Number: ARUF30B14A*
Manufacturer: GOODMAN MANUFACTURING CO., LP.
Trade/Brand name: GOODMAN,JANITROL,AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR
CONDITIONING AND HEATING, ENERGI AIR
Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LID.
Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third
party testing:
Cooling Capacity(Btuh): 28000
EER Rating (Cooling): 11.00
SEER Rating (Cooling): 13.00
Heating Capacity(Btuh)@ 47 F: 27000
Region IV HSPF Rating (Heating): 8.00
Heating Capacity(Btuh)@ 17 F: 16500
Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate.
DISCLAIMER
AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for,
the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out ofthe use or performance of the product(s),or the
unauthorized atteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org.
TERMS AND CONDITIONS
This Certificate and Its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.
The contents ofthis Certificate may not in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any
form or manner or by any means,except for the user's individual,personal and confidential reference.
CERTIFICATE VERIFICATION
The information for the model cited on this certificate can be verified at www.ahridirectory.org, A "IMF, Air-Conditioning,Heating,
click on"Verify Cenificate"link and enter the AHRI Certified Reference Number and the date on
which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. #%N no ILI and Refrigeration Institute
@2012 Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO.: 129960117647454024