Permit HVAC 306 12th St 2012 12
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 12-00001599 Date 10/30/12
Property Address . . . . . . 306 12TH ST
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 3571
----------------------------------------------------------------------------
Application desc
1 cu 1 ahu
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
TOUSEY CLAY B JR & PHYLLIS OCEAN STATE HEAT & AIR, INC.
2225 ALICIA LANE 1476 ATLANTIC BLVD.
ATLANTIC BEACH FL 32233 NEPTUNE BEACH FL 32266
(904) 249-8251
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . . REPLACE 1 CU 1 AHU
Permit Fee . . . . 103 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 4/28/13
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 103 . 00 103 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 107 . 00 107 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd AUlantic Beach. FL 3'22')3
Ph (904) 2471-58-26 Fax (904) 247-584-5
JOB ADDRESS: PERMU 4
PROJECTVALUES �S' 5-31 , 00
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
-Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTUs Per Unit Seer RatinL
Duct Svstems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
-AR1# yy�E-76Z
-Air Conditioning: Unit Quantity Tons Per Unit k E 0 VIP,ED
Heat: Unit Quantity BTUs Per Unit, (r- S(-,cr Rating
Duct Systems: Total CFM REQUIRED
FIRE PRENT,NTION
Fire Sprinkle'r System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantit�, (Requires 3 sets of plans)
Underground Fire Main Value
(Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantit�y (Requires '3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES -T�HSCELLANEOUS:
Prefabricated Fireplace Qty Automobile Lifis
Gas Pipinz Outlets Boilers BTUs
Elevators'E'scalators
ALL OTHER GAS PTLPING Heat Exchanger
Quantity of Outlets Pumps
4 Ventid 'Wall Furnaces Reffigerator Condenser BTU's
4 Water Heaters Solar Collection S-vstems
Tanks (gallons)
Wells
OTHER: L—AD
Permit becomes void if work does noT commence within a six month period o-, work is suspended or abandoned for sixmonths.1 hereby certffill that I have read
this application and k-now the same to be uue and correct. -All provisions oflaws and ordinances governin'gy this work-vill be complied with wn�.-ther specified
or not. The permit does not Ove authority to violate the provisions o'L any other state or local law reguirLion constructio�r,or the performance ofconstruction.
Property ONA-ners Name I bus ey Phone--Number E 1/9 0 7 0 7
Mechanical Company (5(,ccLzA 'i- -Office Phone U�-azr i Fax 2-2 Y Y f
Co. Address: /,,(7(o I"Co GtY-?qr.44u� 6-4� State R- Zip ,?2-1-(.(-
License Holder (Print): ---4--------4tate-C,.�-,irtificationRegistration-# C,*co�-9,?1V
Q ICU
Notarized Signature of License Holder
Sw andsub�s>71'/� be re,methis SO day of CX flu
YVETTE P.MORALES
t
Comm#DD0860534 tary Pu
�*'& 'e 0 -N Pu Ic
of-Notary Pu lie
4L % Signa
2 Expires 3/2/2013
Florida Notary Assn.,Inc
ACCA Manual "J" Heat Load Calculation Date 10/29/12
Customers Name Tousey Location Atlantic Beach
1 Gross Wall 1,680
'680
23
10
20
2,3 Windows !77 17
North Al, N, 2 29.0 16.0 23 667 368
East& West Al, E & W, 2 29,0 46.0 110 3,190 5,060
25.0
South Al, S, 2 29.0 7720 580 500
4 Doors
Front Solid Wood - Panel 27.0 15.8 30 810 474
Patio Solid Wood - Storm 16.4 9.7 60 984 582
1 Other SIdq GI Dr, S, 2 32.6 25.0 0 0 0
5 Net Wall
Area 1 R- 11, 112"Asp. Brd. :3,2 1.9 1,437 4,598 2,730
Area 2 R- 13, 1/2" As ). Brd. 3.0 1.8 0 0
Area 3 R- 13, 1/2"Asp. l3rd. 3.0 1.8 0 0
6 Ceilings
Area 1 Attic, R-22 1-.9 2.1 1,680 3,192 3,528
Area 2 Attic, R- 19 11-1.1 2.3 0
Area 3 Attic, R- 19 2.1 2.3 0 0
7 Floors
Area 1 Slab 1 40.5 0.0 167 6,764 0
Area 2 None 0.0 0.0 0 0
8 Infiltration
Winter Summer Avg Cilng Ht
Poor 1500 -2100 1.2 0.6 9 14,665 12,333
9 Sub Total BTUH Loss
35,450
10 Duct BTUH Loss 3,545
11 TOTAL HEATING LOAD 38,995
12 People and Appliances Bedrooms 3 3,000
13 Sub Total BTUH Gain (Structure)
28,575
14 Duct BTUH Gain Location Attic 15% 4,286
15 TOTAL SENSIBLE
16 Infiltraton Latent Gain Infit. CFM 152 5,254
17 People Latent Gain People 4
1,600
- 19 -TOTAL LATENT 6,854
1 19 ITOtal Cooling Load 39,716
CERTIFIEDT.
www.ahridirectory.org 4�
Certificate of Product Ratings
AHRI Certified Reference Number: "65702 Date: 10/29/2012
Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source
Outdoor Unit Model Number:YHJR42S41S3
Indoor Unit Model Number:AHE42D
Manufacturer:YORK BY JOHNSON CONTROLS
Trade/Brand name: LX SERIES
Manufacturer responsible for the rating of this system combination is YORK BY JOHNSON CONTROLS
Rated as follows in accordance with AHRI Standard 2101240-2008 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-spoinsored, independent,third
party testing:
Cooling Capacity(Btuh): 40500
EER Rating (Cooling): 10.20*
SEER Rating (Cooling): 13.00
Heating Capacity(Btuh)@ 47 F: 39000
Region IV HSPF Rating(Heating): 7.70
Heating Capacity(Btuh)@ 17 F: 22800
Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate.
DISCLAIMER
AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for,
the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance ofthe product(s),or the
unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org.
TERMS AND CONDITIONS
This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.
The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any
form or manner or by any means,except for the user's individual,personal and confidential reference.
CERTIFICATE VERIFICATION
The information for the model cited on this certificate can be verified at www.ahridirectory.org, As "Imp, Air-Conditioning,Heating,
click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on &'%a On ILI and Refrigeration Institute
ic e certificate was issued,which is listed above,and the Certificate No.,which is listed below.
@2012 Air-Conditioning,Heating,and Refrigeration Institute CERTIFICATE NO.: 129960096511668183