Loading...
1174 Beach Ave HVAC 2012CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 12-00001607 Date 10/31/12 Property Address . . . . . . 1174 BEACH AVE Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 5337 ---------------------------------- Application desc Replace 1 cu 1 ahu --------------------------------- PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. Contractor Owner ---------- -------------- _____________ OCEAN STATE HEAT & AIR,INC. HENNESSY 1476 ATLANTIC BLVD. 1174 BEACH AVENUE FL 32233 NEPTUN249E CH FL 32266 ATLANTIC BEACH ----- -----Permit . MECHANICAL HVAC PERMIT Additional desc REPLACE 1 CU 1 AHU Plan Check Fee 00 Permit Fee 91.00 Valuation Issue Date 4/29/13 Expiration Date . . --- - ------------ ------- ---------- STATE MECH DCA SURCHARGE 2.00 Other Fees STATE MECH DBPR SURCHARGE 2.00 _ ________ Charged --- Paid Credited Fee summary - _ _----- Permit Fee Total ---------- 91.00 ---------- .00 91.00 00 .00 .00 Plan Check Total .00 .00 Other Fee Total 4.00 4.00 .00 95.00 .00 .00 Grand Total 95.00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERWT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247-5826 Fax (904) 247-5845 4�e JOB ADDRESS: 1/ 718 e_� A j- f, PERMIT ## PROJECT VALUE S S 3 37 NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Heat: Unit Quantity Tons Per Unit BTU's Per Unit Seer RatinRREQUIAED Duct Systems: Total CFM REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATIONA��9 Air Conditioning: Unit Quantity I Heat: Unit Quantity 1 Tons Per Unit 2 REQUIRED BTU's Per Unit T/Lt-) Seer Rating /SJ' Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity Value (Requires 3 sets of plans) (Requires 3 sets of plans) Underground Fire Main Fire Hose Cabinets Quantity _ (Requires 3 sets of plans) Commercial Hoods Quantity Systems Quantity (Requires 3 sets of plans) (Requires 3 sets of plans) Fire Suppression FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts _ BTU s Gas Piping Outlets Boilers Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets 9 Vented Wall Furnaces Pumps Refrigerator Condenser BTU's it Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six to period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name &�A -r'" Phone Number ?-Vi - /9 -73 Mechanical Company 0(-<" XakAki d.Kae r' _Office Phone ZY r - 2 Z r l Fax Z Y 5 _a 9 Y9 Co. Address: l Y7b ,4 Ffr'c. bt �� City 7T1�,0kvti Q�� State � Zip .3 2z6` License Holder (Print): 1Votarized Signature of License Holder ....... ''VETTE P.�MORALES••••••••_ S O �,• ���:, ,,,, Comm# Woa60534 5 x Expires 31212013 Sigr e+ e" Notary Assn., Inc ,?` c' Florida ............................................: .I• of Notary Certification/Registration t Get tJ?93/0 f - day of ©L�j �J�.t' 2011— 10/30/2012 07:57 FAX 9042498949 OCEAN -STATE -A/C 3 ATLANTIC-BEACH/6002/003 RCCA Manual "J" Heat Load Calculation Customers Name Hennessey Date 10/30/12 Location Atlantic Beach Type of Exposure• Construction Heat Transfer Multipliers •COOLING Area or BTUH 1 Gross Wall 1,332 2,3 Windows North East & West South Al. N. 2 29.0 16.0 11 319 176 Al,E & W. 2 29.0 46.0 89 2,031 3,094 AI, S, 2 29.0 25,0 23 667 575 4 Doors Front Patio Other Solid Woad - Panel 27.0 15.8 30 810 474 Solid Wood - Storm 16.4 9,7 60 994 582 Sldq GI Dr, S, 2 32.6 25.0 0 0 0 5 Net Wall Area 1 Area 2 Area 3 R- 11, 1 /2" As . Brd. 3.2 1.9 983 2,146 1,868 R- 13,1/2" Asp. Brd, 3,0 1,B 0 0 R- 13,1/2' Asp, Brd. 3.0 1.8 0 0 6 Ceilings Area t Area 2 Area 3 Attic, R- 22 1.9 2.1 1,332 2,531 2,797 Attic, R- 19 2,1 2.3 0 0 Attie R- 19 2,1 2.3 0 0 7 Floors Area 7 Area 2 Slab 40.5 0.0 167 4,764 0 None 0.0 0.0 0 0 8 Infiltration winter Suminer Avg Cling Ht 9 Poor 1500-2100 1.2 0.6 5,213 3,325 9 Sub Total BTUH Loss 19,465 10 Duct BTUH Loss 1,1346 11 TOTAL HEATING LOAD 21,411 12 People and Appliances 1 Bedrooms 3 3,000 13 Sub Total BTUH Gain Structure 15,891 14 Duct 8TUH Gain Location Attic 15% 2,384 1$ TOTAL SENSIBLE r 18,275 16 Infiltraton Latent Gain Infit, CFM 120 4,166 17 People Latent Gain I # Peo le 4 1 920 19 TOTAL LATENT 5,086 19 ITotal Cooling Load 23,350 This combination qualifies for a Federal Energy Efficiency Tax Credit when placed in service AM so ILI CERTIFIEDT. between Feb 17, 2009 and Dec 31, 2011. Certificate of Product Ratings AHRI Certified Reference Number: 5020849 Date: 10/29/2012 Product: Split System: Heat Pump with Remote Outdoor Unit -Air -Source Outdoor Unit Model Number: 4TWX5024B1 Indoor Unit Model Number: *AM7AOA24H21 Manufacturer: TRANE Trade/Brand name: XL151 WEATHERTRON Manufacturer responsible for the rating of this system combination is TRANE Rated as 08 for and follows Equ Equipment and subjecwith t to verification of rating ac curacyrbynAHR1 sponso ed, Air-Conditioning Air-Source Heat Pump party testing: Cooling Capacity (Btuh): 23600 EER Rating (Cooling): 13.00 SEER Rating (Cooling): 15.50 Heating Capacity(Btuh) @ 47 F: 21600 Region IV HSPF Rating (Heating): 9.00 Heating Capacity(Btuh) @ 17 F: 13000 Ratings followed by an asterisk (*) indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION ry g The information for the model cited on this certificate can be verified at www.ahridirecto or ow ■o&' Air -Conditioning, Heating, click on "Verify Certificate" link and enter the AHRI Certified Reference Number and the date on and Refrigeration Institute which the certificate was issued, which is listed above, and the Certificate No., which is listed below. CERTIFICATE N O.: 129959855993848282 @2012 Air -Conditioning, Heating, and Refrigeration Institute