160 Magnolia St HVAC 2012 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 12-00001705 Date 11/15/12 Property Address . . . . . . 160 MAGNOLIA ST Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 3550 ---------------------------------------------------------------------------- Application desc Replace 1 cu 1 ahu ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ PASKO TRUST PAULA & FRANK DONOVAN HEATING & AIR 13692 VICTORIA LAKES DR 315 SIXTH AVENUE SOUTH JACKSONVILLE FL 322265800 JAX BEACH FL 32250 (904) 241-3785 ---------------------------------------------------------------------------- Permit MECHANICAL HVAC PERMIT Additional desc . - Permit Fee . . . . 95 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . S/14/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 95 . 00 95 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 99 . 00 99 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach,FL 32233 Ph(904)247-5826 Fax(904)247-5845 JOB ADDREss: PROJECTVALUE$ �)SSO, CcYV NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning. Unit Quantity Tons Per_Unit Heat: Unit Q!!�Ftity BTU's Per Unit Duct Systems: Total CFM Seer Rating MQ-ULIZED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTA �TJOJNN _� Air Conditioning: Unit Quantity Tons Per Unit AJU 4 � Heat: Unit Quantity BTU's Per Unit-12-15 REQUMED jp�odlo Duct Systems: Total CFM Seer Rating REQUDZED FIRE PREVENTION Fire Sprinkler System Quantity Fire (Requires 3 sets of plans) Standpipe, Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIREPLACES MISCELLANEOUS: Prefabricated Fireplace Qty_ Automobile Lifts Gas Piping Outlets Boilers BTU's ALL OTHER GAS PIPING Elevator:��cala�tors Quantity of Outlets Heat Exchanger #Vented Wall Furnaces Pumps #Water Heaters Refrigerator Condenser BTU's Solar Collection Systems Tanks(gallons) Wells OTHER: Permit becomes void if work does not commence within a six 7ont—hperiod or work is suspended or abandoned for six­months.I hereby ce that I have read ordinances governing this work wiff be comphed with whether specified his application and know the same to be true and correct. All Provisions of laws and rtify", )r not The permit does not give: ority to vw* hde the provisions of any other state or local law regulation construction or the performance of construction- :'rOPerty Owners Name=7=!7 Phone Number 4echanical Company la-Anov6 ii �o.Address: --�I 1-U=cePhone S�-f-(--329S-Fax ZHJ-3-?k�S- city 0 �. GeAck -Statef- zip s,�.>-!;b Acense Holder(Print): out State Certification/Regi�tion# lfotarized Swnature ofLicense HoLder A::�a Sworn and subscribed beforem-e this day of C_- 20 V .0y Notary Public State of Florfda ignature of Notary Public 'y . Timothy Lee Hughes My Commission EE 186278 %Xdf Expires D4/0312016 Job: + wrightsoft Project Summary Date: October 4,2012 Entire House By: Aaron Thacker Donovan Heat & Air 315 6th Ave S,Jacksonville Beach, FL 32250 Phone:904-241-3785 Fax 9D4-241-3745 Email:aaron@donovanac.com Web:www.DonovanAC.com F Project Information For: Paula Pasko 160 Magnolia St,Atlantic Beach, FL 32233 Notes: Design Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 'F Outside db 95 'F Inside db 70 oF Inside db 75 'F Design TD 31 'F De§iln TID 20 'F Daily range L Relative humidity 50 % Moisture difference 53 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 11282 Btuh Structure 15262 Btuh Ducts 3353 Btuh Ducts 4753 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 14636 Btuh Use manufacturer's data n Rate/swing multiplier 1.00 Infiltration Equipment sensible load 20015 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2253 Btuh Ducts 1014 Btuh Heatin Coolin Central vent (0 cfm) 0 Btuh Area (ft') 13N 13N Equipment latent load 3267 Btuh Volume (ft') 11916 11916 Air changes/hour 0.45 0.23 Equipment total load 23282 Btuh Equiv.AVF (cfm) 89 46 Req. total capacity at 0.70 SHR 2.4 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade BASE 13 PURON HP Trade BASE 13 PURON HP Model 25HBC330(A,W)"30 Cond 25HBC330(A,W)--30 AHRI ref no3699497 Coil FB4CNF030 AHRI ref no3699497 Efficiency 7.7 HSPF Efficiency 11.0 EER, 13 SEER Heating input Sensible cooling 21000 Btuh Heating output 30000 Btuh @ 47'F Latent cooling 9000 Btuh Temperature rise 27 'F Total cooling 30000 Btuh Actual air flow 1000 cfm Actual air flow 1000 cfm Air flow factor 0.068 cfm/Btuh Air flow factor 0.050 cfm/Btuh Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat Load sensible heat ratio 0.86 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2012-Nov-14 14 10:02 wrightSOft Right-SuiteO universal 8.0.24 RSU05995 Page 1 ACCK C:\Users\Owner\Documents\Wrightsoft HVAC\Bogus 2.5 ton.rup Calc=MJ8 Front Door faces� E CERTIFIEDT. L Plu so IL www.ahridirectory.org Certificate of Product Ratinas AHRI Certified Reference Number: 3699497 Date: 11/15/2012 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 25HBC330(A,W)**30 Indoor Unit Model Number: FB4CNF030 Manufacturer: CARRIER AIR CONDITIONING Trade/Brand name: BASE 13 PURON HP Manufacturer responsible for the rating of this system combination is CARRIER AIR CONDITIONING Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity (Btuh): 30000 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Heating Capacity(Btuh) @ 47 F: 30000 Region IV HSPF Rating (Heating): 7.70 Heating Capacity(Btuh) @ 17 F: 18300 Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accontripanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations.warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for darnages of any kind arising out of the use or performance of the product(s),orthe unauthorized atteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at wvvw.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated:entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org, "IMP, Air-Conditioning,Heating, click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on iM ON ILI and Refrigeration Institute which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. (D2012 Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 129974646067107609