Loading...
2044 Duna Vista Ct 2012 HVAC 2012 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 it Application Number . . . . . 12-00001682 Date 11/13/12 Property Address . . . . . . 2044 DUNA VISTA CT Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 4082 ---------------------------------------------------------------------------- Application desc REPLACE 1 CU 1 AHU ------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ ARMEL BRUCE E & JENNIFER S WAYCHOFFS AIR CONDITIONING 2044 DUNA VISTA CT 6929 PHILLIPS PARKWAY DR S ATLANTIC BEACH FL 322334534 JACKSONVILLE FL 32256 (904) 838-9052 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . REPLACE 1 CU 1 AHU . 00 Permit Fee . . . . 103 . 00 Plan Check Fee 0 Issue Date . . . . Valuation . . . . Expiration Date . . S/12/13 ------ ------------------------------------------------------------- -------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 103 . 00 103 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 107 . 00 107 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, Fl,32233 Ph(904)247-5826 Fax (904) 247-5845 JOB ADDRESS: aC)Lj(4 _�)LL(jCt \/jS+CL COLLr-� PERNHT# lo?- Ik f 2- PROJECT VALUE $ L4081 NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION ARI# 370041-7 Air Conditioning: Unit Quantity Tons Per Unit -3.5 REQUIRED Heat: Unit Quantity BTU's Per Unit 14 It OW Seer Ratil�g'__04(_ Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity — (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity — (Requires 3 sets of plans) TIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty_ Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators �LL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps Vented Wall Furnaces Refrigerator Condenser BTU's Water Heaters Solar Collection Systems Tanks (gallons) Wells )THER: ,rmit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read is application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the perforinance of construction. -operty Owners Name 'Rr L,((!e Phone Number 00y�aLw-,)-7C3z echanical CompanykA)aA42h RIC— —Office Phoneq&o ISSoN I>Slzg_�_l SFax :02 Address:(gPOci !Ali I I IpS 'Pkwv City State FL Zip 3,)a5_& .cense Holder (Print): State Certifi ati egistration 4 CACI-2 118-7 Varized Signature ofLicense Holder S orn and subscribed before-me t s ay of NCN/CrYlbe r 2 0 1,-,L JENNFER LyNm BOOKER Public, yX.1k t WCOWASsmMi" nature of Notary EEXPM Dwmdm 01.2015, U ,I NMI" Job: Right J@ Mobile Report Date: 11112/2012 + wrightsoft Entire House By: AL Project Information For: Bruce Armel 2044 Duna Vista Ct., Atlantic Beach,, FL 32256 Phone: 904- Design Conditions Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature(oF) 70 75 Elevation: 43 ft Design TD (oF) 35 16 30'N Relative humidity(%) 30 50 Latitude: Moisture difference(gr/lb) 8.4 52.8 Outdoor: Heating Cooling Dry bulb(*F) 35 91 Infiltration: Dailyrange('F) - 17 ( M Method Simplified Wet bulb('F) - 77 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 N N 2 -Component Btu h/fF Btuh % of load Walls 2.7 4237 12.8 MIS Dils Glazing 19.7 4216 12.7 Doors 13.5 433 1.3 Claft Ceilings 1.7 3603 10.9 Floors 4.4 9374 28.3 Infiltration 2.2 3876 11.7 ditaficn Ducts 7381 22.3 CdIir9S__ Piping 0 0 Humidification 0 0 Ventilation 0 0 Adjustments 0 Total 33119 100.0 Component Btu h/f? Btuh %of load Walls 1.1 1739 5.8 V�bls rtemal Gans Glazing 45.0 9619 31.8 Doors 11.4 367 1.2 Ceilings 2.1 4457 14.7 Floors 0 0 0 Ga�ng Infiltration 0.5 913 3.0 Duds Ducts 10049 33.2 Ventilation 0 0 Internal gains 3090 10.2 Blower 0 0 aher Adjustments 0 Ceilirgs Infift4on Total 30233 100.0 Latent Cooling Load 4792 Btuh Overall U-\ralue=0.105 Btih/ft2-'F Data entries checked. 2012-Nov-1 2 OBA 3:49 wrightsoft Right-Suite(g)Universal 2012 12.1.00 Right J@ Mobile Page 1 ACCA C:\VnNDOWS\TEMP\w!;tmp\25662d8b-860e-4360-98f7-e8le3366efbb.rup Calc=MJ8 FrontDoorfaces: S Job: Project Summary Date: 11112/2012 + wrightsoft Entire House By: AL Project Information ------ For: Bruce Armel 2044 Duna Vista Ct., Atlantic Beach,, FL 32256 Phone: 904- Notes: Des ig n Information Weather: Jacksonville/Craig, FL, US Winter Design Conditions Summer Design Conditions Outside db 35 *F Outside db 91 *F Inside db 70 'F Inside db 75 -F Design TD 35 'F Design TD 16 'F Daily range M Relative humidity 50 % Moisture difference 53 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 25738 Btuh Structure 20184 Btuh Ducts 7381 Btu h Ducts 10049 Btuh Central vent(0 cfm) 0 Btu h Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 33119 Btu h Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 30233 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2429 Btuh Ducts 2363 Btuh Heating Cooling Central vent(0 cfm) 0 Btu h Area(ft') 2125 2125 Equipment latent load 4792 Btuh Volume(ft) 19125 19125 Air changes/hour 0.32 0.16 Equipment total load 35025 Btuh Equiv.AVF (cfm) 102 51 Req.total capacity at 0.70 SHR 3.6 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref Efficiency 0 HSPF Efficiency 0 SEER Heating input Sensible cooling 0 Btuh Heating output 0 Btuh @ 47-F Latent cooling 0 Btuh Temperature rise 0 'F Total cooling 0 Btu h Actual air flow 1209 cfm Actual air flow 1209 cfm Air flow factor 0.037 cfm/Btuh Air flow factor 0.040 cfm/Btuh Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat Load sensible heat ratio 0.86 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2012-Nov-1 2 08:13:49 + vv'rightsoft Right-SuiteG universal 2012 12.1.00 Right J0 Mobile Page 1 -*—'C�l C:\V\nNDOWS\TEMP\wstmp\25662d8b-860e-436G-98f7-e8le3366efbb.rtjp Calc=MJ8 Front Door faces: S Job: wrightsoft Right-JO Worksheet Date: 11112/2012 Entire House By: AL Entire House First Floor 1 Room name 199.5 ft 199.5 ft 2 Exposed wall 9.0 ft 9.0 ft heat/cool 3 Room height 1�0 x 2125.0 ft 4 Room dimensions 2125.0 ft' 2125.0 ft2 5 Room area I - Ty I Consinj HTM Load Area (ft2) 0'ad U-value Or Area (ft') (ICB h) number (13tuh/ft'�-'IF) (Btuh/ft) or perimeter (ft) .Btu I h) or perimeter (ft) 1:111 -[:��Heat I or I Gross Heat Cc G=. r="PIS Heat 6 2B-3bw 0.079 n 2.73 1 12 360 318 868 356 360 318 868 356 11 D--2ow, 1972 2091 43 0 838 889 43 0 838 889 0570 n 64 57 155 63 2B-3bw 0.079 ne 2.73 1A2 64 57 1 55 63 t-G 1 0.570 ne 19.72 46.75 7 0 140 331 7 0 140 331 1 D-c2ow 2.73 1.12 450 396 1082 444 450 396 1082 444 12B-3bw 0.079 e 0 1068 3413 t-G I D-c2ow 0.570 e 19.72 63.01 54 0 1068 3413 54 2B-3bw 0.079 s 2.73 1.12 405 357 975 400 405 357 975 400 T--G 11 D-c2ow 0.570 s 19.72 25.16 48 0 953 1216 48 0 953 1216 1 2B-3bw 0.079 w 2.73 1.12 454 367 1003 412 454 367 1003 412 1D-,c2ow 0570 w 19.72 63.01 55 0 1076 3439 55 0 1076 3439 111130 0.390 w 13.49 11.43 32 32 433 367 32 32 433 367 2B-3bw 0.079 nw 2.73 1.12 64 57 155 63 64 57 155 63 t--G '1D-c2ow, 0570 nw 19.72 46.75 7 0 140 331 7 0 140 331 C 16G-19al 0.049 1.70 2.10 2125 2125 3603 4457 2125 2125 3603 4457 F 22Acph 1.358 46.99 0.00 2125 200 9374 0 2125 200 9374 0 0 0 21862 161 1 211862_. 16 18,1 Envelope loss/gain 3876 913 3876 913 12 a) Infiltration 0 0 0 0 b) Room ventilation - 690 3 690 13 Internal gains: Occupants @ 230 3 2400 2400 Appliances/other --- - - 25738 20184 25738, 20184, Subtotal(lines 6 to 13) ---- 0 0 0 0 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 25738 20184 25738 20184 14 Subtotal 29% 50% 7381 10049 29% 50% 7381 10049 15 Duct loads - 331191 3023�3 331191 302331 Total room load 12091 12091 120 1209 Air required(cfm) Calculations approved by ACCA to meet all reguirements of Manual J 8th Ed. 2012-Nov-12 08:13:49 %mriiO"'tsc)�ft Right-Suiteg Universal 2012 12.1.00 Right J@ While oorfaces: S Page 1 Ci\VVINDOWS\TEMP\wstrnp\25662dBb-86OeA360-98f7-e8le3366efbb.rup Calc=MJ8 Front D Job: Component Constructions Date: 11112/2012 wrightsoft Entire House By: AL Project Information For: Bruce Armel 2044 Duna Vista Ct.,Atlantic Beach,, FL 32256 Phone-. 904- Design Conditions Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature(T) 70 75 Elevation- 43 ft Design TD(T) 35 16 Relative humidity 30 50 Latitude, 30'N Moisture difference(gr/lb) 8.4 52.8 Outdoor: Heating Cooling Dry bulb(T) 35 91 Infiltration: Daily range(T) - 17 M Method Simplified V\Ietbulb(*F) - 77 Construction quality Average V\find speed(mph) 15.0 7.5 Fireplaces 0 Or Area 1.1-value Insul R Htg HTM Loss Cig HTM Gain Construction descriptions ft2 BtuhW-0F W-0 F/Btuh Btuh/W Btuh l3tuh1W l3tuh Walls 1.12 356 12B-3bw:Frm wall,brk 4"ext,r-1 1 cav ins,1/2"gypsum board int n 318 0.079 14.0 2.73 868 fnsh,r-3 ext bd ins,2"x4"wood frm ne 57 0.079 14.0 2.73 155 1.12 63 e 396 0.079 14.0 2.73 1082 1.12 444 S 357 0.079 14.0 2.73 975 1.12 400 w 367 0.079 14.0 2.73 1003 1.12 412 nw 57 0.079 14.0 2.73 155 1.12 63 all 1550 0.079 14.0 2.73 4237 1.12 1739 Partitions (none) Windows 889 1 D-c2ow:2 glazing,cir outr,air gas,wd frm mat,clr innr,1/4"gap, n 43 0.570 0 193 838 20.9 ne 7 0.570 0 19.7 140 46.8 331 1/8"thk e 54 0.570 0 19.7 1068 63.0 3413 s 48 0.570 0 19.7 953 25.2 1216 w 55 0.570 0 19.7 1076 63.0 3439 nw 7 0.570 0 19.7 140 46.8 331 all 214 0.570 0 19.7 4216 45.0 9619 Doors w 32 0.390 0 13.5 433 11.4 367 11 DO:Door,wd sc type Ceilings 2.10 4457 16C-19al:Attic ceiling,asphalt shingles roof mat,r-19 ceil ins,1/2" 2125 0.049 19.0 1.70 3603 gypsum board int fnsh Floors 0 0 22A-cph:Bg floor,heavy damp soil,on grade depth,carpet fir fnsh 200 1.358 0 47.0 9374 2012-Nov-12 08:13:50 wrightSCM Right-Suite@ Universal 2012 12.1.00 Right JO Mobile Page 1 ACC-l', C:\WiNDOWS\TEMP\wstmp\25662d8b-860e-4360-98f7-e81 e3366efbb.pip Cale=MJ8 Front Door fares S Ulm 0%0 MEN CERTIFIEDT. www.ahridirectory.org Certificate of Product Ratings AHRI Certified Reference Number: 3700417 Date: 11/13/2012 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 213BN(A,W)042****A Indoor Unit Model Number: FX4DN(B,F)043 Manufacturer: BRYANT HEATING AND COOLING SYSTEMS Trade/Brand name: LEGACY LINE PURON HP Manufacturer responsible for the rating of this system combination is BRYANT HEATING AND COOLING SYSTEMS Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (Btuh)-. 41000 EER Rating (Cooling): 11.50 SEER Rating (Cooling): 14.00 Heating Capacity(Btuh) @ 47 F 40000 Region IV HSPF Rating (Heating): 8.00 Heating Capacity(Btuh) @ 17 F 23800 Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products ofAHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org, "IMF, Air-Conditioning,Heating, click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on &I " No ILI and Refrigeration Institute which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. (92012 Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 129972946025883507