Permit HVAC 2057 Mayport Rd 2012 CITY OF ATLANTIC BE�YH .
800 SEMINOLE RbWD
ATLANTIC BEACH,FL 32233
INSPECTION PHONE LINE 247-5814
!tit
Application Number . . . . . 12-00001722 Date 11/20/12
Property Address . . . . . . 2057 MAYPORT RD
Tenant nbr, name . . . . . . VACANT RETAIL
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 34959
----------------------------------------------------------------------------
Application desc
NEW 1 CU 1 AHU
------------------------------------------------ ----------------------------
Owner Contractor
------------------------ ------------------------
SPECIALTY MARINE & IND SUP, INC DONIS AIR CONDITIONING INC
P.O. BOX 330478 2403 KELLOW CIR
ATLANTIC BEACH FL 32233 JACKSONVILLE FL 32216
(904) 398-4972
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . . INSTALL NEW SYSTEM & DUCT
Permit Fee . . . . 135 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date 5/19/13
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 03
STATE MECH DBPR SURCHARGE 2 . 03
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 135 . 00 135 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 06 4 . 06 . 00 . 00
Grand Total 139 . 06 139 . 06 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEA xr
CJEX
$00 Serninole Rd Atlantic Beach,FL 32233
Ph(904)247-5826 Fax (904)247-5845 ?;?-1 C
26 01-?
JOB Amms: 0 m Ar o,+c 4,
PROJECTVALUE APJ 4 5 8--i�60 7d'
REQ 1 0
ME
U
NEW AER CONDITIONING&HJ�ATING SYSTEM INS
Air Conditioning: Unit Quantity Tons Per Unit VALLATION
Heat: Unit Quantity 7 BTU's Per Unit Seer Rating
Duct Systems: Totwcpm REQUI—R—ED
REPLACEMENT AIR CONDITIONING& HEATING SYSTEM INSTALLATION
Air Conditioning: UnitQuantity 4 Tons Per Unit
Heat: Unit Quantity— BTU's Per Unit Seer Ratina-
Duct Systems., Total CFM REQUIRED
FIRE PREVENTION
Fire Sprinlder System Quantity (Requh-es 3 sets of plans)
Fire$tandpipe Quantity (14Zequ
aub"3 sets of plans)
Underground Fire Main Value
Fire Hose Cabinets Quantity (RequIlres 3 sets of plans)
(Requires 3 sets of pl=)
Commercial Hoods Quantity QUquims 3 sets of ilans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplade Qty--__ Automobile Lifts
.083 Piping Outlets Boilers BTU's
ALL OTHER GAS PIPING Elevator�&calat�ors
Quantity of Outlets Heat Exchanger
#Vented Wall Furnaces Pumps
# Water Heaters Refrigerator Condenser BTUT—
Solar Collection Systems
Tanks(gallons)
Wells
OTHER:
I'Milt-�omcs v�old if work dm not commorm with n a six trion—iliperiod or work is suspended orabantlonod for six months.i horeby certilly that I have rcad
thk applimion and know the wrie to be tme And 00ML All provisions of laws and ordinances governing this work will W MOW with Whether mxcirted
ornot, The Permit does not give authority to violate the Provisions of any other state or local law regulation cons i ortbi; ro c orc stru !on,
Property Owners Name S14412dil 6JR01-6 W(-(A 1,600 truct on Per rmanc on ct
Phone Number 90 q- a q 7-
Mechanical Company T)b6V-C. A14
__Zj�c , of fee PJ;0(ne 1, -7 ZZ
QL(3o x X-1��0
Co.Address: L--L.L(14 (f I;L city State�,a�ZIP
License Holder(Print): 130 A1j4LJ1)_ Iq -
(f 1('4 t-&= State CtTdficationMegimation�,#".e__�6�.2-� -(S
er a-
Notarized!1:9.na
SCHANNE R. THOMAS Om and subscribed before'�ne thi da
tu
My COMMSSION#DO 931903 20
rc of Notary Publi
EXPKS:October 8,2013
L/L d 'OU09fftft << SWS L9? 4de(l BULPILng j4p:ni Jn-7A-V1A'2
CERTIFIEDTIA
www.ahridirEictory.org
Certificate of Product Ratings
AHRI Certified Reference Number: 3896076 Date: 11/20/2012
Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source
Outdoor Unit Model Number: GSZ1 30601 A*
Indoor Unit Model Number: AR*F486016C*
Manufacturer: GOODMAN MANUFACTURING CO., LP.
Trade/Brand name: GOODMAN,JANITROL, AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR
CONDITIONING AND HEATING, ENERGI AIR i
Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP.
Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third
party testing:
Cooling Capacity(Btuh): 57000
EER Rating (Cooling): 11.10
SEER Rating (Cooling): 13.00
Heating Capacity(Btuh) @ 47 F: 58000
Region IV HSPF Rating (Heating): 8.20
Heating Capacity(Btuh) @ 17 F: 36000
Ratings followed by an asterisk(*)indicate a Voluntary rerate of previously published data,unless accoinpanied with a WAS,which indicates an involuntary rerate.
DISCLAIMER
AHRI does not endorse the product(s)listed an this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for,
the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising"of the use or performance ofthe products),or the
unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectoTy.org.
TERMS AND CONDITIONS
This Certificate and its contents are proprietary products ofAHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.
The contents ofthis certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any
form or manner or by any means,except for the user's individual,personal and confidential reference.
CERTIFICATE VERIFICATION
The information for the model cited on this certificate can be verified at www.ahridirectory.org, "IMP, Air-Conditioning,Heating,
click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on
which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. Pill" on Iki and Refrigeration Institute
@2012 Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 129979063384924471
Florida Energy Efficiency Code For B uAlding Construction
EnergyGauge SummitO Fla/Com-201 0, Effective Date: March 15, 2012 -- Form 506-2010
Prescriptive Compliance for Renovations, Occupancy Change, etc.
PROJECT SUMMARY
Short Desc: add hvac Description: 2057 mayport road
Owner:
Addressl: 2057 mayport road City: atlantic bch
Address2: State: florida
Zip: 32233
Type: Retail Class: Renovation to existing buildi
Jurisdiction: ATLANTIC BEACH,DUVAL COUNTY,FL(261100)
Conditioned Area: 1600 SF Conditioned&UnConditioned Area: 1600 SF
No of Stories: I Area entered from Plans 1600 SF
Permit No: 0 Max Tonnage 5
If different,write in:
EnergyGauge Summit@ Fla/Com-2010.Section 506A Compliant Software. Effective Date:March 15,2012
11/14/2012 Page I of 7
Project: add hvac
Title:2057 mayport road
Type: Retail
(WEA File: FL—JACKSONVILLE—INTL—ARPT.tm3)
Other Required Compliance
Category Section Requirement(write N/A in box if not applicable) Check
Report 506.4.2 Input Report Print-Out from EnergyGauge FlaCom attached
Operations Manual 303.3.1, Operations manual provided to owner
503.2.9.3,
505.7.4.2
Windows&Doors 502.3.2 Glazed swinging entrance&revolving doors:max. 1.0 cfin/ft2;all
other products: 0.3 cfm/112
Joints/Cracks 502.3.3 To be caulked,gasketed,weather-stripped or otherwise sealed
Dropped Ceiling Cavity 502.3 Vented: seal&insulated ceiling.,Unvented seal&insulate roof&
side walls
HVAC Efficiency 503.2.3 Minimum efficiencies: Tables 503.2.3(l)-(8)
HVAC Controls 503.2.4 Zone controls prevent reheat(exceptions);separate thermostatic EY
control per zone;
Ventilation 503.2.5 Outdoor air supply&exhaust ducts shall have dampers that
automatically shut when systems,or spaces served are not in use.
Exhaust air energy recovery required for cooling systems
(Exceptions).
ADS 503.2.7.5 Duct sizing and Design have been performed
HVAC Ducts 503.2.7 Air ducts,fittings,mechanical equipment&plenum chambers shall
be mechanically attached,sealed', insulated&installed per Table
503.2.7.2.Fan power limitations,
Balancing 503.2.9.1 HVAC distribution system(s)tested&balanced.Report in
construction documents.
Piping Insulation 503.2.8 HAC and service hot water.In accordance with Table 503.2.8.
Water Heaters 504 Performance requirements in accordance with Table 504.2.Heat El
trap required.
Swimming Pools 504.7 Vapor-retardant or liquid cover or other means proven to reduce E]
heat loss on heated pools;Time switch(exceptions);readily
accessible on/off switch.
Motors 505.7.5 Motor efficiency criteria have been met El
Lighting Controls 505.2, 502.3 Automatic control required for interior lighting in buildings>5,000 E]
s.f;Space control;Exterior photo sensor;Tandom wiring with I or
3 linear fluorescent lamps>30W
EnergyGauge Summit@ Fla/Com-201 0.Section 506.4 Compliant Software.Effective Date: March 15,2012
11/14/2012 Page 7 of 7
Piping System Compliance
Category Pipe Dia Is Operating Ins Cond ins Req Ins Compliance
[inches] Runout? Temp [Btu-in/hr Thick[inj Thick[inj
[F] SF.Fl
None
EnergyGauge Summit@ Fla/Com-2010.Section 506A Compliant Software.Effective Date:March 16,2012
11/14/2012 Page 6 of 7
Project: add hvac
Title:2057 mayport road
Type:Retail
(WEA File: FL JACKSONVILLE INTL ARPT.tm3)
System Report Compliance
PrOSyl System 1 Constant Volume Air Cooled No.of Units
Split System<65000 Btu/hr
Component Category Capacity Design Eff Design IPLV Comp-
Eff Criteria IPLV Criteria liance
Cooling System Air Conditioners Air Cooled 13.00 12.23 8.00 PASSES
Split System<65000 Btu/h
Cooling Capacity
Air Handling Air Handler(Supply)- 0.80 0.82 PASSES
System-Supply Constant Volume
PASSES
Plant Compliance
Description Installed Size Design Min Design Min Category Comp
No Eff Eff IPLV IPLV liance
None
Water Heater Compliance
Description Type Category Design Min Design Max Comp
Eff Eff Loss Loss liance
None
EnergyGauge Summit@ Fla/Com-201 0.Section 506.4 Compliant Softvvare. Effective Date:March 15,2012
11/14/2012
Page 5 of 7
External Lighting Compliance
Description Category Tradable? Allowa lace Area or Length ELPA CLP
(W[Unit) or No.of Units (W) (W)
(Sqft or ft)
None
Project: add hvac
Title: 2057 mayport road
Type: Retail
(WEA File: FL JACKSONVILLE INTL ARPT.tm3)
Lighting Power Compliance
Space Ashrae Description Area Height No.of Design Effective Allowance
ID (sq.ft) (ft) Spaces (W) (W) (W)
PrOZolSpl 16 Office-Open Plan 1,600 10.0 1 960 960 1,760
Design 960 (W) PASSES
Effective: 960 (W)
Allowance: 1760 (W)
,Passing requires Design to be at most 100% of Criteria
Project: add hvac
Title: 2057 mayport road
Type: Retail
(WEA File: FL JACKSONVILLE INTL ARPT.tm3)
Lighting Controls Compliance
Acronym Ashrae Description Area Design Min Compli-
ID (sq.ft) CP CP ance
PrOZo I Sp 1 16 Office-Open Plan 1,600 1 PASSES
PASSES
EnergyGauge Summit@)Fla/Com-2010.Section 506,4 Compliant Softvyare.Effective Date:March 15,2012
11/14/2012 Page 4 of 7
CERTIFICATIONS
I hereby certify that the plans and specifications covered by this alculation are in compliance with the
Florida Energy Code
Prepared By- Building Official:
Date: 7/U�- ! Date:
I certify that this building is in compliance wi�h the FLorida Energy Efficiency Code
Owner Agent: Date:
If Required by Florida law, I hereby certify that the system design is::in compliance with the Florida Energy
Efficiency Code
Architect: Reg No:
Electrical Designer: Reg No:
Lighting Designer: Reg No:
Mechanical Designer: Reg No:
Plumbing Designer: Reg No:
Signature is required where Florida Law requires design to be performed by registered design
professionals.
Project: add hvac
Title: 2057 mayport road
Type: Retail
(WEA File: FL—JACKSONVILLE—INTL—ARPT.tm3)
Prescriptive Envelope Compliance
Item Zone Description Design Criteria Meet Req.
Glass PrOZol Percent glass Max allowed .000 50.000 Yes
Skylights PrOZol Percent Skylight Max allowed .000 5.000 Yes
Meets Shell Envelope Requirements --PASSES
EnergyGauge Surnmit@ Fla/Com-2010.Section 506.4 Compliant Software. Effective Date:March 15,2012
11/14/2012 Page 3 of 7
Compliance Summary
Component Design:, Criteria Result
RENOVATED ENVELOPE PRESCRIPTIVE
i PASSES
LIGHTING POWER 960.0 1,760.0 PASSES
LIGHTING CONTROLS PASSES
EXTERNAL LIGHTING None Entered
HVAC SYSTEM PASSES
PLANT None Entered
WATER HEATING SYSTEMS None Entered
PIPING SYSTEMS None Entered
Met all required compliance from Check List? Yes/No/NA
IMP RTANT MESSAGE
Info 5009 An input report of this design building must be submitted along with this
Compliance Report
11/14/2012 EnergyGauge Summit@ Fla/Com-201 0.Section 506.4 Compliant Soft�are, Effective Date:March 15,2012
Page 2 of 7
>
44
0. Y2
ro 0
C14
cl
z
on
cc
a
10
Ln
cl
10, 0
cc
lap
r. 9 4-4
rA
41*1
c
0 CL
en
PO
W) 4�
wj W)
low)
73
C: 44
W2
IM
cn
40
.j
Lo
z
0 coo
4) W2
z
9D
ILL 1-11.
44
CD 10
0 CL 0
9D.
En
00
u
rq
cc
0.