Loading...
Permit HVAC 335 4th St 2012 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ............ ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 r Application Number . . . . . 12-00001733 Date 11/26/12 Property Address . . . . . . 335 4TH ST Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 3700 ---------------------------------------------------------------------------- Application desc REPLACE 3 TON CU & AHU ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ CHAPIN, NAN DONOVAN HEATING & AIR 335 4TH ST 315 SIXTH AVENUE SOUTH ATLANTIC BEACH FL 32233 JAX BEACH FL 32250 (904) 241-378S ---------------------------------------------------------------------------- Permit MECHANICAL HVAC PERMIT Additional desc REPLACE 3 TON CU/AHU Permit Fee . . . . 99 . 00 Plan Check Fee . 00 Issue Date . . . . valuation . . . . 0 Expiration Date . . 5/25/13 ----------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 99 . 00 99 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 103 . 00 103 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. A- 4–RcnAMCAL pERMT ApPLICAnON CITY OFATLANnc BFACH '00 SM'nole Rd Atlantic awk FL 32233 Ph(904)247-5826 Fax(9()4)247-5g45 JOBADDRM: PMMT# momcT vwwE 3-7oo NEW AIR CONDMONING&E[FATjNG SySTEM INSTALLAnON Air Conditi - Unit Quantity 011109-1 Heat Tons PerUnit Duct Systems: Total CFM BTU'S Per Unit---- Seer jRafi—ng REPLACEAUNT AEP.CONDMONING&H]ZATING SySTEM INS iffOR—M Air Conditionying., unit Quantity TALLARON A R I#�3 b Vr Heat Unit Quardi-ty Tons Per Unit 3 Duct Optems.- BTUs Per Unit' Sea Total CFM na 1-3 REQUATM PWVF2MON Fire Sprinkler System Quantity (Requires 3 sets pkm) Fire Sax1pipe Quantity (Requires 3 sets of pbm) Und"mund Fue Alain Value Fire Hose Cabinets Quantity (Requires 3 sets of plaw) Commercial Hoods quantit� (Requires 3 sets of phm) Fire Summession Systems Quantity (Requires 3 sets of phkns) MEPLACES (Requires 3 sets of phkns) Preftdcated Fheplace Qty MISCELLAMOUS: Gas Piping Outletj AutomoWe LffLs Boilers BTUs ALL OTHER GAS PIUMING ElevatorOEj�� quantiti of Outlets Heat Exchanger #Vented Wall Furnaces Reffigerawr Conde-nsa #Water Heaters Sobw Collection Systems BTffs— Tanks(gallons) Wells OTHER: Permit becomes vOid if work dm--not: meow withiii a six nionth-Period Or Work is Mspwded or abandoned:fibr sk months.I hereby certify dM I have read &b SPAcation a4d)mow%e sametDbe fte and cMeM All Provisions of laws and onlinances goveming this work will be complied with whedier q)CCIfied 3r noL llie permit does not gin anthoft to violate the provisions ofaity other state,or local kw regulation construction or the peiftmance of construction. f 11roperty Owners Name o Phone NumberogL��.. Aechanical Company 'I-a-viove,A �o-Address: Z IS- Ldt�, p4 -.Office Phone VI 1-3-7 LS-Fax 7-H 1-31 9Y- Acense Holder(Print).- van City ,.&)" Gelc-k StMefl- Zip kloftrked Sipwftwe ofLkewe Holder State CmfflcationfReeLsftufion#_Lecp3l-)61 sworn subscribed before me this 21 day of 20,A 14 Signature of Notary Public T ...............I............. wrightsoft- Project Summary Job: Date: September 10,2012 Enfire House By: Aaron Thacker Donovan Heat & Air 315 Oth Ave S,Jacksonville Beach,Ft.32250 Phone:904-241-3785 Fax 904-241-3745 Email:aaron@donovanac.com Web:www.DonovanAC.com Project Information For: Nan Ch;fi,n 335 4th t Atlantic Beach, FL 32233 Notes: Desicin Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 OF Outside db Inside db 70 OF Inside db 99 OF 75 OF Design TD 31 OF Design TD 24 OF Daily range L Relative humidity 50 % Moisture difference 69 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 26705 Btuh Structure 23491 Btuh Ducts 4737 Btuh Ducts 4949 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh pipigg 0 Btuh Equipment load 31442 Btuh Use manufacturer's data n Rate/swing multiplier 1.04 Infiltration Equipment sensible load 29578 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1497 Btuh Ducts 2465 Btuh (ft2) Heating Cool'n Central vent (0 cfm) 0 Btuh Area 1W 140 Equipment latent load 3961 Btuh Volume(ft3) 8320 8320 Air changes/hour 0.45 0.23 Equipment total load 33539 Btuh Equiv.AVF(cfm) 62 32 Req. total capacity at 0.70 SHR 3.5 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier i Trade BASE 13 PURON HIP Trade BASE 13 PURON HIP Model 25HBC336(A,W)--30 Cond 25HBC336(A,W)--30 AHRI ref no3699488 Coil FB4CNF036 AHRI ref no3699488 Efficiency 8 HSPF Efficiency 11.0 EER, 13 SEER Heating input Sensible cooling 23800 Btuh Heating output 34000 Btuh @ 47*F Latent cooling 10200 Btuh Temperature rise 27 OF Total cooling 34000 Btuh Actual air flow 1133 cfm Actual air flow 1133 cfm Air flow factor 0.036 cfm/Btuh Air flow factor 0.040 cfm/Btuh Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat Load sensible heat ratio 0.88 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wriightSOft' Right-Suite4l)Universal 8.0.24 RSU05995 2012-Nov-26 07:53:50 C:kUsers\Owner\Documents\Wrightsoft HVAC\Bogus 3 ton-rup Calc=MJ8 Front Door faces: W Page 1 CERTIFIEDTM L www.ahridirectory.o Ig Certificate of Product Ratink"Itft- AHRI Certified Reference Number: 3699488 Date: 11/26/2012 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 25HBC336(A,W)**30 Indoor Unit Model Number: FB4CNF036 Manufacturer: CARRIER AIR CONDITIONING Trisde/Brand name: BASE 13 PURON HP malnufacturer responsible for the rating of this system combination is CARRIER AIR CONDITIONING Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity(13tuh): 34000 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Heating Capacity(Btuh) @ 47 F: 34000 Region IV HSPF Rating(Heating): 8.00 Heating Capacity(Btuh) @ 17 F: 21400 Ratings followed by an asterisk indicate a voluntary rerate of previously published data,unless accornpanied with a WAS,which indicates an involuntary rerate. DISCLAMMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the pro�. uct(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthiDrized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and lite contents are proprietary products ofAHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The co�tents ofthis Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form oO,manner or by any means,except forthe user's individual,personal and confidential reference. CERTIFICATE VERIFICATION The inf#rmation for the model cited on this certificate can be verified at www.ahridirectory.org, A "IMF, Air-Conditioning,Heating, click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on which the cortificate was issued,which is listed above,and the Certificate No.,which is listed below. NMI an ILI and Refrigeration Institute @20i 2 Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 129984094293508376