Loading...
Permit HVAC 465 Beach Ave 2012 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 12-00001743 Date 11/28/12 Property Address . . . . . . 465 BEACH AVE Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 5500 ---------------------------------------------------------------------------- Application desc System 3 . 5 ton change out ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ LOVELL W RADFORD II ENVIRONMENTAL A/C SERVICES, INC 465 BEACH AVE 8110 CYPRESS PLAZA DR STE 106 ATLANTIC BEACH FL 322335321 JACKSONVILLE FL 32256 (904) 279-0030 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . CHANGE OUT 3 . 5 SYSTEM Permit Fee . . . . 103 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 5/27/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 103 . 00 103 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 107 . 00 107 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALI, CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 JoB ADDRESS: Ph (904) 247-5826 Fax (904) 247-5845 41 fz--t� 1141(-z PERMIT 4V PROJECT VALUE $-f=ESO 6), C2 o NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION A R I 3_3 2 y Air Conditioning: Unit Quantity Tons Per Unit -3. REQUIRED Heat: Unit Quantity BTU's Per Unit Seer Rating /V.,�/7 Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps Vented Wall Furnaces Refrigerator Condenser BTU's Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name Rod Loucj� Phone Number Mechanical Company Envir-one.,11t4l h/C- gC,-V;( ei ;.n r, Office PhonqftkZct�wFax&�O.Z>�-o6 Co. Address: 80110 C-140ttss Ph /F r z zo rjr, 0- /0,/, City all, State AL Zip 32-AS4 License Holder(Print): /110 L4/&.-J lu/A /,I/ ///Stde Certification/Registration # Notarized Signature of License Holder worn and subscribed before e this 2-0�daq o f 20 —,—�ay D ignature of Notary M,�COW,, ,�Isl'ot4#EE 051349 Public_4 m 21 2()15 ay pub VC t3oopd TWU wrightsoft Project Summary Job: Entire House Date; 1014112 Energy Design Systems, Inc. BY. M.Ellis I Colo For: Lovett Residence 465 Beach Avenue Atlantic Beach FL Notes: Front door faces West Kitchen Zone Weather: Jacksonville, Int'l AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 OF Inside db Outside db 94 OF 74 OF Inside db Design TD 42 OF Design TD 74 OF Daily range 20 OF Relative humidity IM Moisture difference 50 % Heating Summary 51 grfib Sensible Cooling Equipment Load Sizing Structure 36639 Btuh Structure 25759 Btuh D Ucts 5605 Btuh Ducts Central vent(61 cfm) 2815 Stuh Central vent(61 cfm) 7745 Btuh Humidification 0 Btuh 1341 Btuh Piping 0 Btuh B lower 0 Btuh Equipment load 45060 Btuh Use manufacturers data n Infiltration Rate/swing multiplier 0.99 Method Simplifed Equipment sensible load 34496 Btuh Construction quality Average Latent Cooling Equipment Load SlZing Fireplaces 0 Structure 1785 Btuh Heating Cooling Ducts 1728 btuh Area (ft ) 2408 2408 Central vent (61 cfm) 2120 Stuh Volume (ft3) 19264 19264 Equipment latent load 5633 Btuh Air changes/hour 0.32 0.16 Equipment total load 40128 Btuh Equiv.AVF(cfm) 103 51 Req. total capacity at 0.85 SHR 3.4 Ion Heating Equipment Summary Cooling Equipment Summary Make Trane Make Trane Trade XR13 Weathertron Trade XR13 Weathertron Model 4TWR3042Bl Cond 4TWR3042131 Coil *AM7AOC36H31 Efficiency 8.5 HSPF Efficiency Heating input 14.5 SEER Heating output 40904 Btuh @ 47'F Sensible cooling 33935 Btuh Temperature rise Latent cooling 8484 Btuh 26 OF Total cooling 42419 Etuh Actual air flow 1437 cfm Actual air flow Air flow factor 0.034 ef m1Btu h Air flow factor 1437 cfm Static pressure O�00 in H20 Static pressure 0.043 cfm/Btuh Space thermostat 0.00 in H20 Load sensible heat ratio 0.86 SWdlitalle values have belan manustly gverridden Printout certified by ACCA to meet all requirements of Manual i 8th Ed. vvri9ht;sc3rt- RIUM-Suite ResidenUal 6 0.119 RSR29784 -IM EAE0S\Current\Reslder%aJ changeout manual J\LAC,CraMber Changeout,4169 BUrning Tree Ln,Jax,rr 2012-Oct-04 10-18:57 Page I ........... CERTIFIEDTM L www.ahridirectory.0 rg Ceftificate of Product Ratings AHRI Certified Reference Number: 4563324 Date: 11/28/2012 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 4TWR3042131 Indoor Unit Model Number: *AM7AOC36H31 Manufacturer: TRANE Trade/Brand name: XR13 WEATHERTRON Manufacturer responsible for the rating of this system combination is TRANE Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity(Btuh): 42500 EER Rating (Cooling): 12.00 SEER Rating (Cooling): 14.50 Heating Capacity(Btuh)@ 47 F: 41000 Region IV HSPF Rating (Heating): 8.50 Heating Capacity(Btuh)@ 17 F: 26400 Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.abridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org, "IMP, Ai r-Conditioning,Heating, click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on ams On IL which the certificate was issued,which Is listed above,and the Certificate No.,which is listed below. I and Refrigeration Institute @2012 Air-Conditioning,Heating,and Refrigeration Institute CERTIFICATE NO.: 129985973984104713