Fire Alarm Inspection Test 331 Ahern St 2012 613 N.W.MERCANTILE PLACE 3226 CHERRY PALM DRIVE PORT ST.LUCIE,FL 34986 MTAMPA,FL 33619 772-878-3350-FAX:772-878-5967 11326 DISTRIBUTION AVENUE WEST E 81 3-6 4683 LAR DO AVENUE 0312 JACKSONVILLE,FLORIDA 32256-2745 Automatic Fire Sprinklers, Inc. FORT MYERS,FLORIDA 33905 904-268-3030-FAX:904-268-0724 239-433-3030-FAX:239-433-3263 222 CAPITOL CT. 4370 MOTORSPORT DRIVE 3121 NW 16TH TERRACE CONCORD,NORTH CAROLINA 28027 OCOEE, FL 34761-3033 POMPANO BEACH,FLORIDA 33064 704-782-3032-FAX:704-795-6838 407-656-3030-407-656-8026 954-917-3030-FAX:954-917-9424 Fire Alarm System Inspection and Testing Report This testing was performed in accordance with applicable N.F.P.A.standards. Owner: VIA MARE CONDO ASSOCIATION ISC# J00736 Date: 29 NOVEMBER 21 Owner's Address: 1635 EAGLE HARBOR PRKWY E STE 4 FLEMING IS.,FL 32003 Property Being Evaluated: VIA MARE Property Address: 331 AHERN STREET ATLANTIC BEACH,FL.32233 Monitoring Entity Panel Manufacturer: SILENT KNIGHT Model No. 5700 Name: COPS Circuit Styles: 4.0 Amt 1(SLC) Telephone: 1-800-934-2527 Last Date System Had Service Performed: DECEMBER 2011 /WAFS Account Ref.No. 3258128 Last Date Software or Configuration was Revised: V9.04 AUGUST 2006 Service r,-Weekly AHJ DUVAL COUNTY FIRE MARSHAL (1-Monthly AHJ phone# 904-630-0445 Quarterly ("-Semi-Annually (�` -Digital (-` -R.F. (i-Annually Other(Specify) t Other Specify Inspected by(print) MICHAEL TA Date: 29 NOVEMBER 2012 Time: ELL 1300 Signature of Alarm Agent: (Agent Meets Requirements Per Florida Statute 489.518) Name of Owner or representative S gn tltlu e vto have a copy of NFPA#72(d an extra charge of$50.00. QYes O No Date: 29 NOV:EMBER 2012 !!Owner or Owner rep.not on site. Owner or rep.requests WAFS to release information from inspections to the underwriters of my Insurance company. Oyes ONo System restored to normal operation:Time: 1500 Notifications are made Yes No Who Time Monitoring Entity R 17 OPERATOR 3019 1307 Building Occupants r' F Building Management (X: I- TONY GORIA 1200 Other(Specify) �" r I. ALARM NOTIFICATION APPLIANCES TEST AND INSPECTION Device - Circuit Style/Quantity - Operational Test Approved Location - Pass - Fail Bells Quantity( 4 ) Size(6.00) Type(120VAC ) 15—' PK r 1X_' Horns A( ) B( ) r; h r r Speakers A( ) B( ) r r r r Chimes A( ) B( Strobes A( ) B( ) rr', F r Other:(Specify) A( ) B( ) r r', r r' No.of Alarm indicating circuits: Are Circuits supervised? {`,:Yes (—,No Page 2 II.INITIATING AND SUPERVISORY DEVICE TEST AND INSPECTION Device - Circuit Style/Quantity - Operational Test - Simulated Test - Pass - Fail Manual Stations A( ) B( ) 17, r r' F Ion Detectors A( ) B( ) rl F 17 r'', Photo Detectors A( ) B(1 ) Fx-, r FX_ Duct Detectors A( ) B( ) �-- F F r, Heat Detectors A( ) B( ) rr Waterflow Detectors A( ) B(4 ) r, r Supervisory Switches A( ) B(4 ) r' r (X F Pressure Switches A( ) B( ) F Low Air A( ) B( ) r,' Other(Specify): A( ) B( ) F F, F r III. SUPERVISORY SIGNAL INITIATING DEVICES&CIRCUIT INFORMATION Site Water Temp. Yes (`No C N/A Site Water Level ( Yes (`No r N/A Fire Pump Power ( -Yes r No {i N/A Fire Pump Running (`Yes (`No C N/A Fire Pump Auto Position (`,,Yes (`No f%N/A Fire Pump or Pump Control Trouble (-Yes ( No r!'N/A Generator In Auto Position (`Yes r,,=No (q!)N/A Generator or Controller Trouble 'Yes (`No (!`N/A Switch Transfer (~Yes (' No r%N/A Generator Engine Running (`Yes (`No ( N/A Lock Box (`;Yes (`No lj* N/A A.SIGNALING LINE CIRCUITS Quantity and style(See NFPA 72,Table 3-6)of signaling line circuits connected to system Quantity 1 Style(s): 4.0 IV.SYSTEM POWER SUPPLIES A.Primary(Main):Normal Voltage 120VAC Amps 3 Overcurrent Protection:Type: CKT BRK Amps 20 Location(Panel#): HOUSE PANEL TO RIGHT OF FACP UNDER STAIRS Disconnecting Means Location: CKT 9 B.Secondary(Standby): 24VDC(INSTALLED JUNE 2012) Storage Battery:Amp-Hr.Rating 8Ah Calculated capacity to operate system,in hours: r'' 24 60 NA Engine driven generator dedicated to fire alarm system: C.Location of Fuel Storage: NA D.TYPE BATTERY SECONDARY POWER Dry Cell Type Visual Functional Battery Condition [X— Nickel Cadmium [)W Sealed Lead-Acid Load Voltage 24.6 TX Other(Specify): Discharge Test Min. F Specific Gravity E.Emergency or standby system used as a back-up to primary power supply,instead of using a secondary power supply. NA Emergency system described in N.F.P.A.,.Article 700. Page 3 V.SYSTEM TESTS&INSPECTIONS A.Type Visual Functional D.Notification Appliances - Visual - Functional Control Panel �, Audible F Interface Equipment Visual r', r L.E.D.s/Lampsr r' Speakers (— (— Fuses/MicroBreakers rVoice Clarity �! Primary Power Supply r r Trouble Signals r Disconnect Switches r' r Ground Fault Monitoring r r' E.ON i OFF Premises Monitoring Yes No N/A B.Emergency Communication Equipment Alarm Signal (07 r r— Type Visual Functional N/A Alarm Restoril Phone Set r' Trouble Signal Phone Jacks r' C ' r", � , r, Trouble Restaral Off Hook Indicators Supervisory Signal Amplifier(s) F7 r, (�` Tone Generator(s) �"'' r Supervisory Restoral Call In Signal r, Remote Anuc�iator (` {` (` System Performance (—', r r C.Interface Equipment DEVICE SIMULATED (SPECIFY) VISUAL OPERATION OPERATION WAYNE NET r' F r' r r r r � r Special Hazard System(Specify) F— VI.COMMENTS: SIGNALS RECEIVED&RESTORED W/OPERATOR 2106 at 1525 VII.DEFICIENCIES: These items are the owner's responsibility to be repaired and will be quoted separate from inspection cost. 1)FLOW BELL ON BUILDING ONE DID NOT OPERATE WITH WATER FLOW 2)BUILDING TWO&THREE FLOW SWITCHES ACTIVATED FLOW BELLS,BUT DID NOT REPORT TO FACP;SPRINKLERS PRESENTLY IMPAIRED DUE TO ALARM NOT REPORTING TO FACP OR MONITORING