Loading...
Permit HVAC 161 16th St 2012 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 12-00001830 Date 12/18/12 Property Address . . . . . . 161 16TH ST Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 3000 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ AYERS RICHARD J & CYD L DONOVAN HEATING & AIR 161 16TH STREET 315 SIXTH AVENUE SOUTH ATLANTIC BEACH FL 32233 JACKSONVILLE BEACH FL 32250 (904) 241-3785 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . REPLACE 1 CU 1 AHU Permit Fee . . . . 95 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 6/16/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 95 . 00 95 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 99 . 00 99 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. A- ft—CHANICAL PERMIT APPLICATION CITY OF ATLANTIC BFACH goo Semin0le Rd Atlantic Beach,FL 32233 JOB ADDR=: t Ph(904)247-5826 Fax(904)247-5845 sT A 2a PERMFT# PRO.WCTVALUE 3000 NEW AIR CONDMONING&EIFATING SYSTEM INSTALLATION Air Conditiojifing.- Unit Quantity Tons Per Unit Heat: Unit Quantity BTUsPerUnit'— Seer Ratin—Ly Duct Systems: Total CFM REQMW REPLACEMENT AIR CONDITIONING&HFATING SYSTEM T-#AI=IAIAr Air,Caxhfi * Unit Quantity Tons Per Unit ARJ1#,36 Heat 0=9-* Unit Quantity BTLI-s Per Unit qc?p_ Seer Ratinig /5,3 Duct Systems: Total CFM RBQU� FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of phums) Fire Stan0pipe 3 sets of pbm) Underground Fire Main ?=,Y 3 sets of phius) Fire Hose Cabinets Quantity 3 sets of phm) Commercial Hoods Quantity 3 sets of pbw) Fire Suppression Systems Quantity 3 sets of phums) FWPLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts (Requh-es (Requires (Requrwn (Requires (Requires Gas Piping Outlets Boilers BTUs ElevatoriJ"�a�m ALL CKIBER GAS PIPING Heat Exchanger Quantity of Outlets PUMPS #Vented Wall Furnaces I Water Heaters Srw�erogjioction systems BlUs Tanks ns) wells OTEMR: Ramit becomes void if work do-w not vdddnagx month periodorwork issuspPendellorabaodoned1w six month&I her*certifymatnimeread counnence hbWhcadonmdknow*esamtobeMwmdwnoa All povhionsof lam andwdinancesgovanntinswwkwill be compbW*vh whotherVeMed )rwt 11e,peradt does not eve anthomy to viollft the provWons of my other state or local law regniadw consftuction or the patnrmance ofconstrucdon. 'W�OwnersName P,&ayd AtAe (� Phone Number ft 43-5 93 7,5-- dectianical Company 'CL-viova on Office Phone 'Z-'t 1-3*7WFax �Z�1-3-)9s- 'o.Address: Z 1 15- Lit:" 16i ure- City- d&v- Ge-4r-k statef- zip ,icenseBolder(Print): wAUP-w,,- _ State CC[tifiCatiOnMegistration.# -3-1161 Totariwd S4P"w"ofLA�mw Holder Sworn and subscribed before me this day of 201�- Notary Public S of Florida Sigmitwe OfNatary Public Tknothy Lee Hughes M 'on EE 186278 :04"10312016 ME.YpCi, Job: Project SuMm3rY [)Ste� [)@comber 14,2012 wrigh 4 Entire House By: Aaron Thacker Donovan Heat& Air MS Avo beggh.F1,32250 Phone:904-241-3785 Far.go4-241.3T45 Effialp.agroo@donovome-com Web;vr&w.0cnoY*nAC-con1 ILI For: Richard Ayers 161 16th St,Atlantic Beach, FL 32233 Notes, Weather: Jacksonville Mayport Naval, FL, US Winixar Design Conditions Summer Design Conditions 39 OF Outside db 95 OF Outside db 70 OF Inside db 75 OF Inside db 31 OF D ign 20 'IF Design TD D I ra L al 50 % Relat' e umidity moisture difference 53 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 11282 Stuh Structure 15262 Stuh 3308 Btuh Ducts 4672 Stuh Ducts vent (0 rfm) 0 Stuh Central van:(0 cfm) 0 Stuh Central 0 Btuh Humidificat on 0 Btuh Blower pip' 0 Btuh Ing ,manufacturer's data n 14-590 Btuh Use Equipment oad Rate/swing multiglier 1.00 Infiltration Equipment sensi a load 19934 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construmceti cluality Average 0 Structure 2253 Btuh Fireplaces Ducts 997 Btuh Heafin Coolin Central vent 0 cfm) 0 Btuh Area(ft. 13N 1321 Equipment Uent 100 3250 Btuh Volume?1ft-1 11916 Equipment total load 23184 Btuh Air chanWs/hour 0,45 0.23 Equiv.AVF (cfm) 89 46 Req. tctal capacity at 0,70 SHR 2.4 ton Heating Equipment Summary Cooling Equipment Summary Make Tempstar Make Tempstar Trade 15 SEER N SERIES R410A HP Trade 15 SEER N SERIES R410A HIP Model NXH530GKA* Cond NXH530GKA* C00 FXM4X30**A* AHRI ref nxWO844 AHRI ref no3670844 Efficiency 8.7 HSPF Efficiency 12.5 EEP., 15.3 SEER Sensible cooling 20160 Btuh Heating in 28600 Btuh 47OF Latent cooling 8640 Stuh Heating o W. 28WO Btuh Temperatu e rise 27 OF Total cooling 960 cfm Actual air I low 960 cfm Actual air flow O.OoG cfm/Btuh Air flow factor 0,048 cfm/Btuh Air flow fe.1or 0 in 1120 Static pressure 0 in H20 Static pressure 0.86 Load sensible heat ratio Space thot mostat Calculations approved by ACCA to meet all requirements of Manuel d 8th Ed. 20124)ec-14 0%52:50 wrll�MSOft" Rlghl�SOQAD unlverso)0,0,24 RSU05995 Flage I ,0& c:wsamow ionnocumants)WdOtsoft HVAMOgue 2,6 ton,ruo Galc-M.10 rront 000r faces; E This combination qualifies for a Federal Energy Efficiency Tax Credit when placed in service amal CERTIFIEDTM between Feb 17,2009 and Dec 31,2011. L www.ahridirectory.org 'A Certificate of Product Ratings AHRI Certified Reference Number: 3670844 Date: 12/18/2012 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: NXH530GKA* Indoor Unit Model Number: FXM4X30**A* Manufacturer: TEMPSTAR Trade/Brand name: 15 SEER N SERIES R410A HP Manufacturer responsible for the rating of this system combination is TEMPSTAR Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity(Btuh): 28800 EER Rating (Cooling): 12.50 SEER Rating(Cooling): 15.25 Heating Capacity(Btuh) @ 47 F: 28200* Region IV HSPF Rating (Heating): 8.50* Heating Capacity(Btuh) @ 17 F: 17000 Ratings followed by an asterisk(*)indicate a voluntary rerate of previOLISly 1)ublished data,unless accoinpanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized afteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.orcj. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org, Air-Conditioning,Heating, click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on On ILI and Refrigeration Institute which the cerdficato was issued,which is listed above,and the Certificate No.,which is listed below. 9 @2012 Air-Conditioning,Heating,and Refrigeration Institute CERTIFICATE NO.: 13000310508515511