Permit HVAC 950 Seminole Rd 2012 1,11 4' 11,
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 12-00001896 Date 12/20/12
Property Address . . . . . . 950 SEMINOLE RD
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
1 cu 1 ahu
----------------------------------------------------------------------------
Owner Contractor
------------------------ ----I-------------------
HOWELL, SHIRLEY B ONE HOUR AIR
950 SEMINOLE RD 1015 ATLANTIC BLVD #249
ATLANTIC BEACH FL 32233 ATLANTIC BEACH FL 32233
(904) 222-8482
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee . . . . 103 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 6/18/13
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 103 . 00 103 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 107 . 00 107 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph(904)247-5826 Fax(904) 247-5845
JoB ADDRESS: /U PERmrr#
PROJECTVALUE $
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Ratin REQUIRED
Duct Systems: Total CFM
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
ARI# 320
__�j�5(9�6 —
Air Conditioning: Unit Quantity Tons Per Unit REQUIRED
Heat: Unit Quantity BTU'sPerUnit q'2 15�- SeerRating J �(
Duct Systems: Total CFM REQUIRED
IMF PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty_ Automobile Lifts
Gas Piping Outlets Boilers BTUs:
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
Vented Wall Furnaces Refrigerator Condenser BTU's
Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER:
Pen-nit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
this application and know the same to be true and correct. AJI provisions of laws and ordinances governing this work will be complied with whether specified
or not The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
Property Owners Name WiLCIMAJ Phone Number 2� �—?/&�—
Mechanical Company nrue Office Phone 2-'41-3 10-;�ax -2 Y-7-2 2
�ity LC76�
Co. Address: //96) M41100 ,11 F/ / tate J��:zip
License Holder(Print): Ce, ication/Registrat;ion W--�2
Notarized Signature of License Holder
4pin 201Z
EEd subscribed before this ay o
&HIFLEYLGRA AM
rPb;.iary 1 11 - --6,
W-j Rai No�qry Public linlerwriters
UAO�11i�3sja�,; nc, -'I-
$, 4- al e of Notary Pu
wrightsoft' Project Summary Job: 121055
Date: 12120/2012
Entire House By: CRAIG EDDY
ONE HOUR AIR
1198-MAYPORT RD#1.ATLANTIC BEACH,FL 32233 Phone:904-241-3107 Fax:904-247-5526 License:CAC1814420:
Project Information
For: WILLIAM HOWELL
950 SEMINOLE RD,ATLANTIC BEACH, FL 322�3
Phone: 904-249-9185
Notes:
Design Information
Weather: Jacksonville/Craig, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 35 'F Outside db 91 *F
Inside db 70 *F Inside db 75 *F
Design TD 35 *F Design TD 16 *F
Daily range M
Relative humidity 50 %
Moisture difference 53 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 26902 Btuh Structure
30914 Btuh
Ducts 0 Btuh Ducts 0 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 Cim) 0 Btuh
Humidification 0 Btuh Blower
0 Btuh
Piping 0 Btuh
Equipment load 26902 Btuh Use manufacturers data y
Rate/swing multi lier 1.00
Infiltration Equipment senste load 30914 Btuh
i
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 3545 Btuh
Ducts 0 Btuh
Heating Cooling Central vent (0 cfm) 0 Btuh
Area(ft� 1808 1808 Equipment latent load 3545 Btuh
Volume (ft) 16272 16272
Air changes/hour 0.38 0.20 Equipment total load 34460 Btuh
Equiv.AVF(cfm) 103 54 Req.total capacity at 0.74 SHR 3.5 ton
Heating Equipment Summary Cooling Equipment Summary
Make GOODMAN Make GOODMAN
Trade AMANA DISTINCTIONS Trade AMANA DISTINCTIONS
Model GSZ1 30421 Cond GSZ130421
AHRI ref 4358320 Coil ASPF426016
AHRI ref 4358320
Efficiency 0 HSPF Efficiency 14 SEER
Heating input Sensible cooling:1 30299 Btuh
Heating output 0 Btuh @ 47-F Latent cooling !i 10701 Btuh
Temperature rise 0 *F Total cooling 41000 Btuh
Actual air flow 1407 cfm Actual air flow 1407 cfm
Air flow factor 0.052 cfm/Btuh Air flow factor 0.046 cfm/Btuh
Static pressure 0 in H20 Static pressure 0 in H20
Space thermostat Load sensible heat ratio 0.90
Calculations approved by ACCA to meet all requirements::of Manual J 8th Ed.
2012-Dec-20 05:51:12
vvr19hft0ft' Right-Suites Universal 2012 12.1.00 Right JS Mobile Page 1
C:�WNDOWS\TEMP\wstmp\6bOldbff-3da2-4acO-8325-620014fe6e83.rup CaIc-MJ8 FrontDoorfaces: E
CERTIFIEDTM
www.ahridirectory.org A
Certificate of Product Rafinqs
AHRI Certified Reference Number: 4358320 Date: 12/20/2012
Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source
Outdoor Unit Model Number: GSZ130421A*
Indoor Unit Model Number: ASPF426016E*
Manufacturer: GOODMAN MANUFACTURING CO., LP.
Trade/Brand name: GOODMAN, JANITROL,AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR
CONDITIONING AND HEATING, ENERGI AIR
Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP.
Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third
party testing:
Cooling Capacity(13tuh): 41000
EER Rating (Cooling): 11.30
SEER Rating (Cooling): 14.00
Heating Capacity(Btuh)@ 47 F: 40500
Region IV HSPF Rating (Heating): 8.20
Heating Capacity(Btuh)@ 17 F: 24000
Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate.
somm�
DISCLAIMER
AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for,
the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the
unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory atwww.ahridirectory.org.
TERMS AND CONDITIONS
This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.
The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any
form or manner or by any means,except for the user's individual,personal and confidential reference.
CERTIFICATE VERIFICATION
The information for the model cited on this certificate can be verified at www.ahridirectory.org, A' C nditioning,Heating,
click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on so ILI on"d R,efrigeration Institute
which the certificate was issued,which is listed above,and the Certificate No.,which is listed below.
@2012 Air-Conditioning,Heating,and Refrigeration Institute CERTIFICATE NO.: 130004916499322464