Loading...
Permit HVAC 950 Seminole Rd 2012 1,11 4' 11, CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 12-00001896 Date 12/20/12 Property Address . . . . . . 950 SEMINOLE RD Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu ---------------------------------------------------------------------------- Owner Contractor ------------------------ ----I------------------- HOWELL, SHIRLEY B ONE HOUR AIR 950 SEMINOLE RD 1015 ATLANTIC BLVD #249 ATLANTIC BEACH FL 32233 ATLANTIC BEACH FL 32233 (904) 222-8482 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 103 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 6/18/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 103 . 00 103 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 107 . 00 107 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904)247-5826 Fax(904) 247-5845 JoB ADDRESS: /U PERmrr# PROJECTVALUE $ NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Ratin REQUIRED Duct Systems: Total CFM REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION ARI# 320 __�j�5(9�6 — Air Conditioning: Unit Quantity Tons Per Unit REQUIRED Heat: Unit Quantity BTU'sPerUnit q'2 15�- SeerRating J �( Duct Systems: Total CFM REQUIRED IMF PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty_ Automobile Lifts Gas Piping Outlets Boilers BTUs: Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps Vented Wall Furnaces Refrigerator Condenser BTU's Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Pen-nit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. AJI provisions of laws and ordinances governing this work will be complied with whether specified or not The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name WiLCIMAJ Phone Number 2� �—?/&�— Mechanical Company nrue Office Phone 2-'41-3 10-;�ax -2 Y-7-2 2 �ity LC76� Co. Address: //96) M41100 ,11 F/ / tate J��:zip License Holder(Print): Ce, ication/Registrat;ion W--�2 Notarized Signature of License Holder 4pin 201Z EEd subscribed before this ay o &HIFLEYLGRA AM rPb;.iary 1 11 - --6, W-j Rai No�qry Public linlerwriters UAO�11i�3sja�,; nc, -'I- $, 4- al e of Notary Pu wrightsoft' Project Summary Job: 121055 Date: 12120/2012 Entire House By: CRAIG EDDY ONE HOUR AIR 1198-MAYPORT RD#1.ATLANTIC BEACH,FL 32233 Phone:904-241-3107 Fax:904-247-5526 License:CAC1814420: Project Information For: WILLIAM HOWELL 950 SEMINOLE RD,ATLANTIC BEACH, FL 322�3 Phone: 904-249-9185 Notes: Design Information Weather: Jacksonville/Craig, FL, US Winter Design Conditions Summer Design Conditions Outside db 35 'F Outside db 91 *F Inside db 70 *F Inside db 75 *F Design TD 35 *F Design TD 16 *F Daily range M Relative humidity 50 % Moisture difference 53 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 26902 Btuh Structure 30914 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 Cim) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 26902 Btuh Use manufacturers data y Rate/swing multi lier 1.00 Infiltration Equipment senste load 30914 Btuh i Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3545 Btuh Ducts 0 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area(ft� 1808 1808 Equipment latent load 3545 Btuh Volume (ft) 16272 16272 Air changes/hour 0.38 0.20 Equipment total load 34460 Btuh Equiv.AVF(cfm) 103 54 Req.total capacity at 0.74 SHR 3.5 ton Heating Equipment Summary Cooling Equipment Summary Make GOODMAN Make GOODMAN Trade AMANA DISTINCTIONS Trade AMANA DISTINCTIONS Model GSZ1 30421 Cond GSZ130421 AHRI ref 4358320 Coil ASPF426016 AHRI ref 4358320 Efficiency 0 HSPF Efficiency 14 SEER Heating input Sensible cooling:1 30299 Btuh Heating output 0 Btuh @ 47-F Latent cooling !i 10701 Btuh Temperature rise 0 *F Total cooling 41000 Btuh Actual air flow 1407 cfm Actual air flow 1407 cfm Air flow factor 0.052 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat Load sensible heat ratio 0.90 Calculations approved by ACCA to meet all requirements::of Manual J 8th Ed. 2012-Dec-20 05:51:12 vvr19hft0ft' Right-Suites Universal 2012 12.1.00 Right JS Mobile Page 1 C:�WNDOWS\TEMP\wstmp\6bOldbff-3da2-4acO-8325-620014fe6e83.rup CaIc-MJ8 FrontDoorfaces: E CERTIFIEDTM www.ahridirectory.org A Certificate of Product Rafinqs AHRI Certified Reference Number: 4358320 Date: 12/20/2012 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: GSZ130421A* Indoor Unit Model Number: ASPF426016E* Manufacturer: GOODMAN MANUFACTURING CO., LP. Trade/Brand name: GOODMAN, JANITROL,AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR CONDITIONING AND HEATING, ENERGI AIR Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP. Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity(13tuh): 41000 EER Rating (Cooling): 11.30 SEER Rating (Cooling): 14.00 Heating Capacity(Btuh)@ 47 F: 40500 Region IV HSPF Rating (Heating): 8.20 Heating Capacity(Btuh)@ 17 F: 24000 Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. somm� DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory atwww.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org, A' C nditioning,Heating, click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on so ILI on"d R,efrigeration Institute which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. @2012 Air-Conditioning,Heating,and Refrigeration Institute CERTIFICATE NO.: 130004916499322464