Loading...
Meadows Electric 0001.1 Meadows Electric, Inc. -A- 2 73 0-7 Clydo Road Jacksonville, Fl. 32207 Phone (904) 367-0676 Fax (904) 367-0544 Atlantic Beach City Hall Cff�Aop p R 0 V E 0 r ATLkt4TIC BEACH ELECTRICAL j3UILDING OFFICE low Gear Submittals 011 RECEIVED NOV 0 8 2004 BORDEN CONSTRUCTION, INC. REXEL GEAR QUOTE By Doug Epps Neg# L23407076401 Alt#0000 11/05/04 11:07:10 Customer Bill of Material 00* I Pow-R-Linela 30 Circuits,225A,Fully Rated,208Y/120V 3Ph 4W,Copper Bus, l0k AIC,200A,3P ED Main Breaker, Surface Mounted I 200A,3P ED Main Breaker I 50A,2P BAB Branch Breaker I 60A,3P BAB-H Branch Breaker I 30A,3P BAB-H Branch Breaker 6 IP Branch Provision Only 2 20A,2P BAB Branch Breaker I 30A,2P BAB Branch Breaker I 60A,2P BAB Branch Breaker I 25A,3P BAB-H Branch Breaker 5 20A, IP BAB Branch Breaker I Copper Main Bus,225 Amps I Std.Bolted Cu Ground Bar(Cu Cable Only) I Panel Nameplate-Black with White Letters I NEMA I Enclosure:YS2042 I Standard Trim:LT2042S Designations: LG I Pow-R-Linela 30 Circuits, 100A,Fully Rated,208Y/120V 3Ph 4W,Copper Bus, l0k AIC, I OOA,Main Lugs Only, Surface Mounted I I OOA,Main Lugs Only 14 IP Branch Provision Only 16 20A, I P BAB Branch Breaker I Copper Main Bus, 100 Amps I Std.Bolted Cu Ground Bar(Cu Cable Only) I Panel Nameplate-Black with White Letters I NEMA I Enclosure:YS2036 I Standard Trim:LT2036S Designations: LH I Safety Switches DR361 UGK, BE3 I A,600 VAC,30 Amps,3-Pole,Non-Fusible with No Neutral,NEMA I Enclosure I Heavy Duty Switch -Non-Fusible,3-Pole,600 VAC, 30 A,NEMA I (DH361 UGK) Designations: 2 Safety Switches DH362UGK, BE3 I A, 600 VAC,60 Amps,3-Pole,Non-Fusible with No Neutral,NEMA I Enclosure I Heavy Duty Switch -Non-Fusible,3-Pole,600 VAC,60 A,NEMA I (DH362UGK) Designations: REXEL GEAR QUOTE By Doug Epps Negff L23407076401 A'It#0000 11/05/04 11:07:10 Customer Bill of Material 6 Safety Switches DH361 URK, BE3 I A,600 VAC,30 Amps,3-Pole,Non-Fusible with No Neutral,NEMA 311 Enclosure I Heavy Duty Switch -Non-Fusible,3-Pole,600 VAC,30 A,NEMA 3R(DH361URK) Designations: General Information Service Voltage: 208Y/120V 3Ph 4W Enclosure: NEMA I Main Breaker 200A Bus Rating&Type: 225A Copper Neutral Rating: 225A Ground Bar: Sid,Bolted Copper,Cu cable only ED3200, Vert Mtri S.C.Rating: 1 Ok A.I.C.Fully Rated I Main Device Type: Main Breaker-Top Cable Entry 3AB3060 BAB2060 2 Main Terminals: Mechanical-(1)#1 4-VO(Cu/Al) Neutral Terminals: Mechanical-(1)#6-300 kcmil(Cu/AI) 3 4 Box Catalog No.: YS2042 Trim: Standard Trim(LT2042S) 5 BAB2050 6 Surface Mounted 7_BAB30301 8 Box Dimensions: 42"[1066.8mm]H x 2(Y'[508.0mm]W x 5.75"[146.Omm]D 9 BAB3025H ic Min.Gutter Size: Top=5.5"[1 39.7mm]Bottom=5.5"[1 39.7mm] — Left=6.9'[152.4mm]Right=6.U'[152.4mml I Panel ID Nameplate: (1)LG 3 BAB2030 Type: Plastic,adhesive-backed (2)20BY/120V 3Ph 4W Color: Black with White Letters (3) 5 BAB2020 7 BAB2020 if NEC Lighting&Appliance,UL CTL —Non4nterchangeable Main Device- 9 BABI020 2( Copper Neutral I BAB1 020 BAB1020 2; Trim Lock:Standard Latch&Lock 3 BABI020 BAB 1020 24 Circuit Directory:Plastic Sleeve With Card 5 PROV PROV 2( 7 PROV M1 PROV 2f PROV PROV 3( Blank Cover 3inches Device Modifications: Branch Devices Ref# Description Qty Poles Trip Frame Amps KAJC 5 1 20 BAB 100 10 1 2 50 BAB 100 10 1 2 60 BAB 100 10 1 2 30 BAB 100 10 2 2 20 BAB 100 10 1 3 60 BAB 100 10 1 3 30 BAB 100 10 1 3 25 BAB 100 10 6 1 PROV Notes PREPARED BY DATE THE INFORMATION ON THIS DOCUMENT L234 iim= EATON IS CREATED BY EATON. APPROVED BY DATE JOBNAME ATLAN`11C BEACH CITY HALL IT 18 DISCLOSED IN CONFIDENCE 11106104 DESIGNATION LG AND IT 13 ONLY TO BE USED FOR THE VERSION TYPE DRAWING TYPE PURPOSE IN WHICH IT 13 SUPPUED. 5.0 PRL1a Customer Approval NEGALT NUMBER REVISION DWG SIZE G.O. ITEM IEET L23407076401-OOW A F I General Information Service Voltage: 208Y/120V 3Ph 4W Enclosure: �NEMA 1 Main Lugs Only Bus Rating&Type: 1 OOA Copper Neutral Rating; 100A 1 OOA Ground Bar: Std.Bolted Copper,Cu cable only S.C.Rating: I Ok A.I.C.Fully Rated Main Device Type: Main Lugs Only-Top Cable Entry BABI020 BAB1 020 2 Main Terminals: Mechanical-(1)#14-1/0(Cu/AI) Neutral Terminals: Mechanical-(1)#14-1/0(Cu/AI) 3 BAB1020 BAB1 020 4 Box Catalog No.: YS2036 Trim: Standard Trim(LT2036S) 5 BAB1 020 BABI020 6 Surface Mounted 7 BAB 1020 BABI 020 8 Box Dimensions: 39'[914.4mm]H x 2U'[508.OmmyV x 5.76'[146.0mm]D 9 BAB 1020 BAB1020 Min.Gutter Size: Top=5.5"(1 39.7mm]Bottom=5.5"[1 39.7mm] Left=6.(Y'll 52.4mm]Right=6.0"11 52.4mm] I BABI020 BAB1020 Panel ID Nameplate: (1)LH 3 BAB1 020 BAB1 020 Type: Plastic,adhesive-backed (2)208YI120V 3Ph 4W 5 BAB1020 BAB1020 if Color: Black With White Letters (3) 7 PROV PROV if NEC Lighting&Appliance,UL CTL —Non4nterchangeable Main Device- 9 PROV PROV 2( 1 PROV PROV 2; Copper Neutral Trim Lock:Standard Latch&Lock 23 PROV PROV 21 Circuit Directory:Plastic Sleeve with Card ?5 PROV PROV 2f 27 PROV PROV 2f �9 PROV PROV 3( Blank Cover 4inches Device Modifications: Branch Devices Ref# Description Qty Poles Trip Frame Amps KAIC 16 1 20 BAB 100 10 14 1 PROV Notes PREPARED BY DATE THE INFORMATION ON THIS DOCUMENT L234 wo5m EATON 13 CREATED BY EATON. APPROVED BY DATE JOBNAME ATLAN'11C BEACH CITY HALL IT 16 DISCLOSED IN CONFIDENCE 11/06104 DESIGNATION LH AND IT 18 ONLY TO BE USED FOR THE VERSION TYPE DRAWING TYPE PURPOSE IN WHICH IT 13 SUPPLIED. 6.0 PRLIa Customer Approval SHEET UU0707"01-1XIN 1 OF I NEG-ALT NUMBER REVISION DD�WZG SIZE G.O. ITEM A A Safety Switch General Infonnation Global Specifications System voltage 600 VAC Switch Type Single Throw-Heavy Duty Poles[Blades 3-Pole Amperage 30 Protection Non-Fusible with No Neutral Enclosure Type NEMA 1 Special Paint ANSI-61 (Gray)Standard Switch Lugs Standard Fungus Proof Treatment N Lock-On Provision N Trapped Key Interlock None Fuse Pullers N Control Pole N Ground Lugs N 316 Stainless N Stainless Mechanism N Mill Duty N Cover Controls Narneplate Field Installed Kits Safety Switch Catalog No. DH361UGK PREPARED BY DATE THE INFORMATION ON THE DOCUWNT L2.0 ivowo4 EATON 0 CREATED BY PPROVEDBY DATE JOB NAME ATILAPMC BEACH CITY HALL EATON. IT 0 DISCLOSED IN CONFIDENCE DESIG NATION AND IT IS ONLY TO BE USED FOR THE - ----- VERSION TYPE DRAWING TYPE PURPOSE IN WHICH IT 4 SUPPLIED. 5.0 Customer Appr. ------- ITEM NEG-ALT NUMBER REVISION DWG SIZE G,O, ECT L2-UO7076401-0000 1 _­_____­_________,—--------- REFERENCE NOTES ERES, 600 VOLTS HEAVY DUTY 1. 30-60 AMP DWG NO 95-955-10 K-SERIES DESIGN. 2. 2 AND 3 POLE FUSIBLE AND NON-FUSIBLE SWITCHES. 3. NEMA I ENCLOSURE: 0.048" COLD ROLLED STEEL. 4 7 [124] 4. MEETS FEDERAL SPECIFICATIONS WS865C. 8 5. MEETS UL 98 FOR SWITCHES, UL 50 FOR ENCLOSURES. 6. MEETS NEC WIRE BENDING SPACE REQUIREMENTS. 7. MEETS NEMA STANDARDS KS1. 8. UL LISTED, FILE NO. 5239. c 9, ANSI 61 LIGHT GRAY BAKED ENAMEL FINISH. CA F,a- KNOCKOUTS TOP AND BOTTOM 8 18 [206] 3 [l 9] 10 [254] 4 MAX. 7 [22] CA CA co K'14 3 MTG. SCREWS 11(5 1/4" MAX. DIA. —v-d- CA CA- 33�] 4 3 5 [92) 8 _P6 El 65] —ioo �otoo CONDUIT KNOCKOUT SIZES in [mml CA I CB 3/4 [17], 1 [25], 1 1/4 [32] 1 1/2 [13], 3/4 [17], 1 [25], 1 1/4 [32] —MENSIONS IN in(mm) ALL KNOCKOUTS ARE CONCENTRIC UNLESS NOTED OTHERWISE 4/98 PREPARED BY DATE THE INFORMATION ON THIS DOCUMENT L2U ii/o5m EATON IS CREATED BY EATON. APPROVED BY DATE JOBNAME ATLANnC BF-ACH CITY HALL IT 13 DISCLOSED IN CONFIDENCE DESIGNATION AND IT IS ONLY TO BE USED FOR THE VERSION TYPE DRAWING TYPE PURPOSE IN WHICH IT IS SUPPLIED. 5.0 Customer Appr. NEGALT NUMBER REVISION G.O. ITEM SHEET L2340707"01-0000 20F2 Safety Switch General Inforrnation Global Specifications System Voltage 600 VAC Switch Type Single Throw-Heavy Duty Poles/Blades 3-Pole Amperage 60 Protection Non-Fusible with No Neutral Enclosure Type NEMA I Special Paint ANSI-61 (Gray)Standard Switch Lugs Standard Fungus Proof Treatment N Lock-On Provision N Trapped Key Interlock None Fuse Pullers N Control Pole N Ground Lugs N 316 Stainless N Stainless Mechanism N Mill Duty N Cover Controls Nameplate Field Installed Kits Safety Switch Catalog No. DH362UGK PREPARED BY DATE THE INFORMATION ON THIS DOCUMENT L234 11105104 EATON 0 CREATED BY EATON. APPROVED BY DATE JOB NAME ATLANTIC BEACH CITY KALL IT 6 DISCLOSED IN CONFIDENCE DESIGNATION AND IT 0 ONLY TO BE USED FOR THE VERSION TYPE— DRAWING TYPE PURPOSE IN WHICH IT 0 SUPPLIED. 5.0 Customer Appr. 1 OF NEG-ALT NUMBER REVISION DWG SIZE GO. ITEM SHEET L234707601-0000 2 REFERENCE NQ_T_E5_- DWG NO 95-955-10 1. 30-60 AMPERES, 600 VOLTS HEAVY DUTY K-SERIES DESIGN. 2. 2 AND 3 POLE FUSIBLE AND NON-FUSIBLE SWITCHES. 3. NEMA 1 ENCLOSURE: 0.048" COLD ROLLED STEEL. 4 7 [124] 4. MEETS FEDERAL SPECIFICATIONS WS865C. 8 5. MEETS UL 98 FOR SWITCHES, UL 50 FOR ENCLOSURES. 6. MEETS NEC WIRE SENDING SPACE REQUIREMENTS. 7. MEETS NEMA STANDARDS KS1. C 8. UL LISTED, FILE NO. 5239. 9. ANSI 61 LIGHT GRAY BAKED ENAMEL FINISH. CA r_lco KNOCKOUTS TOP AND BOTTOM 8 1 -1 [206] 3 [19] 10 [254] 4 MAX. 7 [221 CA CA l' o 00 3 MTG. SCREWS 1/4" MAX. DIA. CD low r-loo to _mt CA CA- r 5 1 [133] 3 5 [92] 4 6 12 [165]- �100 W)loo CONDUIT KNOCKOUT SIZES in [mml CA I CB 3/4 [17], 1 (25], 1 1/4 (32) 1 1/2 [13], 3/4 [17], 1 [25], 1 1/4 [32] —ENSIONS IN in(mm) ALL KNOCKOUTS ARE CONCENTRIC UNLESS NOTED OTHERWISE 4/98 PREPARED BY DATE THE INFORMATION ON THIS DOCUMENT L234 i i iosm EATON 18 CREATED BY EATON. APPROVED BY DATE JOBNAME ATLANTIC SFACH CITY HALL IT 13 DISCLOSED IN CONFIDENCE DESIGNATION AND IT 13 ONLY TO BE USED FOR THE VERSION TYPE DRAWING TYPE PURPOSE IN WHICH IT IS SUPPLIED. 6.0 Customer Appr. __ I NEGALT NUMBER RE-VISION DWG SIZE G.O. ITEM IEET L2UO7076401-0000 A F2 Safety Switch General Infonnation Global Specifications System Voltage 600 VAC Switch Type Single Throw-Heavy Duty Poles/Blades 3-Pole Amperage 30 Protection Non-Fusible with No Neutral Enclosure Type NEMA3R Special Paint ANSI-61 (Gray)Standard Switch Lugs Standard Fungus Proof Treatment N Lock-On Provision N Trapped Key Interlock None Fuse Pullers N Control Pole N Ground Lugs N 316 Stainless N Stainless Mechanism N Mill Duty N Cover Controls Nameplate Field Installed Kits Safety Switch Catalog No. DH361 URK THE INFORMATION ON THIS DOCUMENT PREPARED BY DATE L234 11/05/04 EATON IS CREATED BY EATON. APPROVED BY DATE JOB NAME ATLANnC BEACH CITY HALL IT 15 DISCLOSED IN CONFIDENCE DESIGNATION AND IT IS ONLY TO BE USED FOR THE -VERSION DRAWING TYPE PURPOSE IN WHICH IT IS SUPPLIED. 5.0 Customer Appr. NEG�ALT NUMBER REVISION DWGSIZ G.O. ITEM SHEET UU07076014MID [ 1101`2 A REFERENCE NOTES VOLTS HEAVY DUTY DWG NO 95-955-11 1. 30-60 AMPERES. 600 K—SERIES DESIGN. 2. 2 AND 3 POLE FUSIBLE AND NON—FUSIBLE SWITCHES. 3. NEMA 3R ENCLOSURE; 0.052" ZINC COATED STEEL. 4 7 [124] 4. MEETS FEDERAL SPECIFICATIONS WS865C. 5. MEETS UL 98 FOR SWITCHES, UL 50 FOR ENCLOSURES. CA 6. MEETS NEC WIRE BENDING SPACE REOUIREMENTS. (BOTTOM ONLY) 7. MEETS NEMA STANDARDS KS1, C 8. UL LISTED, FILE NO. 5239. 9. ANSI 61 LIGHT GRAY BAKED ENAMEL FINISH. 10. SIDE HINGED WITH DRIP SHIELD. 11. USE TYPE DS/CS GROUP I HUB. ��ITOP ENDWALL SUPPLIED WITH BLANK PLATE FOR INTERCHANGEABLE HUBS 8 1 [206] 3 [191 10 [254] 1c;C7 8 4 MAX. F3' .T, 0 MTG. SCREWS 1/4" MAX. DIA. 77 C:) CID CA + !L 4 y Y, 7 3 5 [92] 8 [22] 8 — 5 [l 343] [165] —6 2 CONDUIT KNOCKOUT SIZES in [mm] CA I CB 3/4 [19]. 1 [251, 1 1/4 [32] 1 1/2 [13], 3/4 [19], 1 [25], 1 1/4 [32] DIMENSIONS IN in(mm) ALL KNOCKOUTS ARE CONCENTRIC UNLESS NOTED OTHERWISE 4/98 PREPARED BY DATE THE INFORMATION ON THIS DOCUMENT L234 EATON IS CREATED BY EATON. APPROVED BY DATE JOBNAME ATLANTIC BEACH CITY HALL IT 13 DISCLOSED IN CONFIDENCE DESIGNATION AND IT IS ONLY TO BE USED FOR THE VERSION TYPE DRAWING TYPE PURPOSE IN WHICH IT 18 SUPPLIED. 6.0 Customer Appr. NEGALT NUMBER RE\/ISION DWG SIZE G.O. ITEM L2=1707"011-0000 REXEL GEAR QUOTE By Doug Epps Neg#L23407076401 Alt#0000 11/05/04 11:07:10 Customer Bill of Material FM,,LT*N Electrical Selling Policy Effective:October 1,2003 Page I Supersedes Selling Policy 25-000, GENERAL TERMS AND Distribution and Pages 1-4,dated May 1,2000 CONDITIONS OF SALE Control Products and Services 25-000 Terms and Conditions of Sale above,the price of the Products or Services will The Terms and Conditions of Sale set forth herein, Termination and Cancellation be increased 1%per month or fraction thereof up and any supplements which may be attached Any order may be terminated by the Buyer only by to a maximum of 18 months from the date of the hereto,constitute the fijll and final expression of written notice and upon payment of reasonable Buyer's order.For delays resulting in shipment or the contract for the sale of products or services termination charges,including all costs plus profit. provision of Services beyond 18 months from the (hereinafter referred to as Product(s)or Services by !Xwe date of the Buyer's order,the price must be 570 4 wurctom t all t, fi Eaton Electrical Inc.(hereinafter referred to as Sell a9jk1WF44'at renegotiated. Seller)to the Buyer,and supersedes all prior any dmcLJ*avviMos*oticc if Buyer breaches any Price Policy-BUS quotations,purchase orders,correspondence or of the terms hereot becomes the subject of any Refer to Price Policy 25-050. communications whether written or oral between proceeding under state or federal law for the the Wier and the Buyer.Notwithstanding any relief of debtors,or otherwise becomes insolvent Minimum Billing contrary language in the Buyer's purchase order, or bankrupt,generally does not pay its debts as Orders less than$250 will be charged a$30 correspondence or other form of acknowledgment, they bccorne due or makes an assignment for the handling fee. Buyer shall be bound by these Terms and bencfit of creditors. Conditions of Sale when it sends a purchase order Taxes or otherwise indicates acceptance of this contract, Prices The price does not include any taxes.Buyer shall or when it accepts delivery from Seller of the All prices are subject to change without notice.In be responsible for the payment of all taxes Products or Services.THE CONTRACT FOR the event of a price change,the effective date of applicable to,or arising from the transaction,the SALE OF THE PRODUCTS OR SERVICES IS the change will be the date of the new price or Products,its sale,value,or use,or any Services EXPRESSLY LIMITED TO THE TERMS AND discount sheet,letter or telegrarn.All quotations performed in connection therewith regardless of CONDITIONS OF SALE STATED HEREIN. made or orders accepted after the effective date the person or entity actually taxed. ANY ADDITIONAL OR DIFFERENT TERMS will be on the new basis.For existing orders,the PROPOSED BY BUYER ARE REJECTED price of the unshipped portion of an order will be TERMS OF PAYMENT UNLESS EXPRESSLY AGREED TO IN the price in effect at time of shipment. WRITING BY SELLER.No contract shall exist Products except as herein provided. Price Policy—Products and Services Terms of payment for assembled Products When prices are quoted as firm for quoted listed below are net witbin 30 days from Complete Agreement shipment,they arc firm provided the following date of invoice: No amendment or modification hereto nor any conditions are met: Adjustable Speed Drives statement,representation or warranty not contained Automatic Transfer Switches herein shall be binding on the Seller unless made I. The order is released with complete Custom Control Panels in writing by an authorized representative of the cnginLefing details. Elcctrocenters Seller.Prior dealings,usage of the trade or a 2. Shipment of Products arc made,and Services Excitation Control course of performance shall not be relevant to purchased are provided within the quoted Industrial PC's determine the meaning of this contract even though lead time. Load Interrupter Switchgear the accepting or acquiescing party had knowledge 3. When drawings for approval are required for LV and MV Busway of the nature of the performance and opportunity any Products,the drawings applicable to LV and MV Motor Control Centers for objection. those Products must be returned within 30— LV and MV Switchgear calendar days from the date of the original Navy Circuit Breakers Quotations mailing of the drawings by Seiler.The return Network Protectors Written quotations are valid for 30 days from its drawings must be releascd for manufacture Operator Interface date unless otherwise stated in the quotation or and shipment and must be marked Panciboards&Switchboards terminated sooner by notice. "APPROVED"or"APPROVED AS Power Circuit Breakers and Fuses NOTED".Drawing re-submittals which are Solid State Starters Verbal quotations,unless accepted,expire the required for any other reason than to correct Unit Substation Transformers same day they arc made. Seller crrors will not extend the 30-day— period. Terms of payment for standard or stock A complete signed order must be received by Products will be: Seller within 20 calendar days of notification of If the Buyer in itiatcs or in any way causes delays 2%1 O'h proximo,Net 25h proximo for award,otherwise the price and shipment will be in shipment,provision of Services or return of invoices dated I'through 15*of the month; subject to re-ncgotiation. approval drawings beyond the periods stated REXEL GEAR QUOTE By Doug Epps Neg# L23407076401 Alt#0000 11/05/04 11:07:10 -AW Customer Bill of Material 2%25'h proximo,Net 10"'2"d proximo for Services Terms of payment for orders exceeding invoices dated 16'h through 3 1 . Terms of payment are net within 30 days $50,000.00 shall be made according to the from date of invoice for orders amounting to following: Note: Refer to Product discount sheets for less that$50,000-00. further clarification as to which terms of payment apply. FM,TON Electrical Selling Policy 25-000 October 1,2003 Page 2 1. Twenty percent(20%)of order value At Buyer's option,Seller will deliver the Products consider the witness tests waived with the right to with the purchase order payable 30 F.O.B.destination freight prepaid and 2%will be ship and invoice the Products. days from date of invoice. added to the net price. 2. Eighty percent(80%)of order value in Held Orders equal monthly payments over the Shipment and Routing For any order held,delayed or rescheduled at the perfbi-mance period payable 30 days Seller shall select the point of origin or shipment, request of the Buyer,Seller may,at its sole option from date of invoice. the method of transportation and the routing of the (1)require payment to be based on any reasonable shipment. basis�including but not limited to the contract Except for work performed(i)under a firm price,and any additional exp crises,or cost fixed price basis or(ii)pursuant to terms of a If the Buyer specifies a special mode of resulting from such a delay;(2)store Products at previously priced existing contract between transportation or routing,Buyer shall pay all the sole cost and risk of loss of the Buyer-,and/or Seller and Buyer,invoices for work freight. (3)charge to the Buyer those prices under the performed by Seiler shall have added and applicable price policy.Any order so held delayed noted on each invoice a charge of 3%(over When freight is included in the price,no allowance or rescheduled beyond twelve(12)months will be and above the price of the work)which is will be made in lieu of transportation if the Buyer treated as a Buyer termination. related to Seller compliance with present and accepts shipment at factory,warehouse,or freight proposed environmental,health,and safety station or otherwise supplies its own Drawing Approval regulations associated with prescribed transportation. Seller will design the Products in line with,in requirements covering hazardous materials Seller'sjudgment,good commercial practice.If at management and employee training, Risk of Loss drawing approval Buyer makes changes outside of communications,personal protective Risk of loss or damage to the Products shall pass to the design as covered in their specifications,Seller equipment,documentation and record Buyer at the F.O.B.point. will then be paid reasonable charges and allowed a keeping associated therewith. commensurate delay in shipping date based on the Concealed Damage changes made. Adequate Assurances Except in the event of F.O.B.destination If,in thejudgmcnt of Seiler,the financial shipments,Seller will not participate in any WARRANTV condition of the Buyer,at any time during the settlement of claims for concealed damage. period of the contrac�does not justify the terms of Warranty For Products payment specified,Seller may require full or When shipment has been made on an F.O.B. Seller warrants that the Products partial payment in advance. destination basis,the Buyer must unpack manufactured by it will conform to Seller's immediately and,if damage is discovered must: applicable specifications and be free from Delayed Payment failure due to defects in workmanship and If payments are not made in accordance with these I. Not move the Products from the point of material for one(1)year from the date of terms,a service charge will,without prejudice to examination. installation of the Product or eighteen(18) the right of Seller to immediate paymenL be added 2. Retain shipping container and packing months from the date of shipment of the in an amount equal to the lower of 1.5%per month material. Product,whichever occurs first. or fraction thereof or the highest legal rate on the 3. Notify the carrier in writing of any apparent unpaid balance. damage. In the event any Product fails to comply with 4. Notify Seller representative within 72 hours of the foregoing warranty Seller will,at its FREIGHT delivery. option,either(a)repair or replace the 5. Send Seller a copy of the carrier's inspection defective Product,or defective part or F.O.B.—PIS—FrtJPpd.and Invoiced report. component thcreo�F.O.B.Seller's facility Automatic Transfer Switches and Renewal Parts, freight prepaid,or(b)credit Buyer for the and Electronic Operator Interface Products are sold Witness Tests/Customcr Inspection purchase price of the Product.All warranty F.O.B.point of shipment freight prepaid and Standard factory tests may be witnessed by the claims shall be made in writing. Seller invoiced to the Buyer. Buyer for$1500 per day per Product type.Buyer requires all non-conforming Products be may final inspect Products at the factory for$500 returned at Seller's expense for evaluation F.O.B.-P/S-FrtJPpd.and Allowed per day per Product type. unless specifically stated otherwise in writing All other Products sold are delivered F.O.B.point by Seller. of shipment,freight prepaid and included in the Seller will notify Buyer fourteen(14)calendar price. days prior to schedule witness testing or This warranty does not cover failure or inspection.In the event Buyer is unable to attend, damage due to storage,installation,operation F.O.B.Ditstination-FrtJPpd.and Allowed the Parties shall mutually agree on a rescheduled or maintenance not in conformance with date. However,Seller reserves the right to Seller's recommendations and industry standard practice or due to accidenL misuse, REXEL GEAR QUOTE By Doug Epps Neg#L23407076401 Alt#0000 11105104 11:07:10 Customer Bill of Material abuse or negligence.This warranty does not receives from the supplier. 36 months—4%of Contract Price cover reimbursement for labor,gaining access,removal,installation,temporary Extended Warranty for Products Special Warranty(In and Out)for power or any other expenses which may be If requested by the Buyer and specifically Products and specifically accepted incurred in connection with repair or accepted in writing by Seiler,the foregoing If requested by the Buyer replacement. standard warranty for Products will be in writing by Seiler,Seller will,during the extended from the date of shipment for the warranty period for Products,at an additional cost This warranty does not apply to equipment period and price indicated Mow: of 2%of the contract price,be responsible for the not manufactured by Seller. Seller limits direct cost of itself to extending the same warranty it 24 months—2%of Contract Price 30 months—3%of Contract Price FM,ILTON Electrical Selling Policy 25-000 October 1,2003 Page 3 1. Removing the Product from the installed Warranty for Power Systems Studies includes the provision of Services,prior to(i) location. Seiler warrants that any power systems commencement of work at any site under a 2. Transportation to the repair fitcility and studies performed by it will conform to specific Purchase Order, (ii)a change in the work return to the site. generally accepted professional standards. scope of any Purchase Order,the Buyer will certify 3. Reinstallation on site. Any portion of the study which does not so that the work area associated with the Seller's conform shall be corrected by Seiler upon scope of work includes the handling of Class 11 The total liability of Seller for this Special notification in writing by the Buyer within ACM,including but not limited to generator Warranty for Products is limited to 50%of six(6)months after completion of the study. wedges and high temperature gaskets which the contract price of the particular Product A]I warranty work shall be performed in a include asbestos materials.The Buyer shall,at its being repaired and excludes expenses for single shift straight time basis Monday expense,conduct abatement should the removal, removing adjacent apparatus,walls,piping, through Friday. In the event that the study handlin&modification or reinstallation,or some or structures,temporary service,etc. requires correction of warranty items on an all of them,of said Class II ACM be likely to overtime schedule,the premium portion of generate airborne asbestos fibers;and should such Warranty For Services such overtime shall be for the Buyer's abatement affect the cost of or time of performance Seller warrants that the Services performed account. of the work then Seller shall be entitled to an by it hereunder will be performed in equitable adjustment in the schedule,price and accordance with generally accepted other pertinent affected provisions of the contract. professional standards. Limitation on Warranties for Products, Compliance with Nuclear Regulation The Services which do not so conform shall Services and Power Systems Studies Seller's Products are sold as connnercial grade be corrected by Seller upon notification in THE FOREGOING WARRANTIES ARE Products not intended for application in facilities writing by the Buyer within one(1)year after EXCLUSIVE EXCEPT FOR or activities licensed by the United States Nuclear completion of the Services. WARRANTIES OF TITLE AND AGAINST Regulatory Commission for atomic purposes. PATENT INFRINGEMENT. SELLER Further certification will be required for use of the Unless otherwise agreed to in writing by DISCLAIMS ALL OTHER WARRANTIES Products in any safety-rclated application in any Seiler,Seller assumes no responsibility with INCLUDING ANY IMPLIED nuclear fiteility licensed by the U.S.Nuclear respect to the suitability of the Buyer's WARRANTIES OF MERCHANTABILITY Regulatory Commission. equipment or with respect to any latent AND FITNESS FOR A PARTICULAR defects in the same.This warranty does not PURPOSE. Returning Products cover damage to Buyer's equipment, Authorization and shipping instructions for the components or parts resulting in whole or in CORRECTION OF NON-CONFORMITIES return of any Products must be obtained from Seiler part from improper maintenance or operation IN THE MANNER AND FOR THE before returning the Products. or from their deteriorated condition. Buyer PERIOD OF TIME PROVIDED ABOVE will,at its cost,provide Seller with SHALL CONSTITUTE SELLER'S SOLE When return is occasioned due to Seller error,full unobstructed access to the defective Services, LIABILITY AND BUYER'S EXCLUSIVE credit including all transportation charges will be as well as adequate free working space in the REMEDY FOR FAILURE OF SELLER TO allowed. immediate vicinity of the defective Services MEET ITS WARRANTY OBLIGATIONS, and such facilities and systems,including, WHETHER CLAIMS OF THE BUYER Product Notices without I imitation,docks,cranes and utility ARE BASED IN CONTRACT,IN TORT Buyer shall provide the user(including its disconnects and connects,as may be (INCLUDING NEGLIGENCE OR STRICT employees)of the Products with all Seller supplied necessary in order that Seller may perform its LIABILITY),OR OTHERWISE. Product notices,warnings,instructions, warranty obligations. The conducting of any recommendations,and similar materials. tests shall be mutually agreed upon and Asbestos Seller shall be notified oC and may be Federal Law requires that building or facility Force Majeure present at�all tests that may be made. owners identify the presence,location and quantity Seller shall not be liable for failure to perform or of asbestos containing material(hereinafter delay in performance due to fire,flood,strike or "ACK')at work sites.Seiler is not I icensed to other labor difficulty,act of God,act of any abate ACM.Accordingly,for any contract which governmental authority or of the Buyer,riot, REXEL GEAR QUOTE By Doug Epps Neg# L23407076401 Alt#0000 11/05/04 11:07:10 Customer Bill of Material embargo,fuel or energy shortage,car shortage, Patent Infringement held to infiringe United States patent and the wrecks or delays in transportation,or due to any Seller will defend any suit or proceeding use of such Products is enjoined,Seller may, other cause beyond Seller's reasonable control.In brought against Buyer,or Buyer's customers, at its option and expense,either procure for the event of delay in performance due to any such so far as based upon a claim that any Buyer the right to continue using and selling cause,the date of delivery or time for completion Products infringe any United States patent,if the Products;or replace the Products with will be extended by a period of time reasonably notified in reasonable time and given non-infiinging apparatus;or modify it so it necessary to overcome the cffect of such delay. authority,information and assistance(at becomes non-infiringing;or,as a last resort, Seller's expense)for the defense of same, remove the Products and refund the purchase Liquidated Damages and Seller shall pay all legal and court costs price.In no case does Seller agree to pay any Contracts which include liquidated damage clauses and expenses and court assessed damages recovery based upon its Buyer's savings or for failure to meet shipping orjob completion awarded therein against Buyer and resulting profit through use of Seller's Products promises are not acceptable or binding on Seller, from or incident to such suit or proceeding. whether the use be special or ordinary.The unless such clauses are specifically accepted in In addition to the foregoing,if at any time foregoing states the entire liability of Seller writing by an authorized representative of the Seller Seller determines there is a substantial for patent infringement. at its headquarters office. question of infringement of any United States patent or in case any Products are judicially FARX611111 Electrical Selling Policy 25-000 October 1,2003 Page 4 COST OF CAPITAL,CLAIMS OF The preceding paragraph does not apply to CUSTOMERS OF THE BUYER OR ANY modifications made by Buyer to Products SPECIAL,INDIRECT,INCIDENTAL OR furnished by Seiler or to Products mamifitctured CONSEQUENTIAL DAMAGES to Buyer's design and specifications or to the use WHATSOEVER. of Products with other products where Products do not in themselves infringe a United States THE TOTAL CUMULATIVE LIABILITY OF patent,As to any Products manufactured to SELLER ARISING FROM OR RELATED TO Buyer's design or specifications,or when THIS CONTRACT WHETHER THE CLAIMS Products are used with other products,Buyer ARE BASED IN CONTRACT,IN TORT shall hold Seller harmless in the same nianner (INCLUDING NEGLIGENCE OR STRICT and to the extent of Seller's obligation described LIABILITY)OR OTHERWISE,SHALL NOT in the preceding paragraph.Buyer shall be EXCEED THE PRICE OF THE PRODUCT OR responsible for obtaining all license rights SERVICES ON WHICH SUCH LIABILITY IS required by Seller for software products in the BASED. possession of Buyer whose use is required by Seller in performing Services for Buyer. Compliance with OSHA Seller offers no warranty and makes no representation that its Products comply with the provisions or standards of the Occupational Safety and Health Act of 1970,or any regulation issued thereunder.I a no event shall Seiler be liable for any loss,damage,fines,penalty or expenses arising under said Act. Limitation of Liability THE REMEDIES OF THE BUYER SET FORTH IN THIS CONTRACT ARE EXCLUSIVE AND ARE ITS SOLE REMEDIES FOR ANY FAILURE OF SELLER TO COMPLY WITH ITS OBLIGATIONS HEREUNDER. NOTWITHSTANDING ANY PROVISION IN THIS CONTRACT TO THE CONTRARY,IN NO EVENT SHALL SELLER BE LIABLE IN CONTRACT,IN TORT(INCLUDING NEGLIGENCE OR STRICT LIABILITY)OR OTHERWISE FOR DAMAGE TO PROPERTY OR EQUIPMENT OTHER THAN PRODUCTS SOLD HEREUNDER,LOSS OF PROFITS OR REVENUE,LOSS OF USE OF PRODUCTS, ll1r.,TeN I Cutler-Hammer Standard Specifications for Pow-R-Line C' Panelboards -Type PRLI a INDUSTRY STANDARDS Cutler-Hammer panelboards are designed to meet the following applicable industry standards(unless noted) • Underwriters'Laboratories,Inc. Panelboards:UL 67 Cabinets and Boxes: UL 50 (Note-Only paneiboards containing UL listed devices can be UL labeled.) • National Electrical Code • NEMA Standard PB1 • Federal Specification W-P-1 15c All circuit breakers are UL listed under UL 489, comply with Federal Specification W-C-375a,b and conform to the applicable requirements of NEIVIA Standard ABI. All panelboards are seismically qualified for Uniform Building Code and California Building Code Zone 4. INTERIORS Panelboard interiors are assembled with bolt-on(or plug-on)protective devices and are designed for sequence phase connection of branch devices to evenly balance electrical loads.Devices can be replaced without disturbing adjacent units or removing main bus connections. Bus bars are sized in accordance with UL standards to limit temperature rise on any current carrying part to a maximum of 650 C above a 400 C ambient. Standard terminals are mechanical type suitable for either copper or aluminum conductor and are installed with appropriate anti-tum provisions. Neutral bus,when provided,will be full size and insulated with a suitable terminal for each outgoing conductor BOXES Panelboard boxes are constructed from code gauge commercial galvanized steel.Standard boxes are provided with blank removable endwalls. All boxes are sized to provide wire bending space as required by the NEC. Interior mounting studs include in and out adjustment capability for installation alignment. TRIMS Trims are made of code gauge sheet steel with a rust inhibiting phosphatized coating and finished with ANSI-61 gray polyester powder paint.Trims are available for both surface and flush mounted applications. Trims include doors with concealed hinges that allow a 130-degree swing to provide access to circuit breaker handles without exposure to live parts.Separate dead front cover allows access to panelboard interior when trim is removed. All doors include a latch and cylinder lock assembly. An locks are keyed alike. Doors up to 48 inches high have a single point catch and lock. Doors over 48 inches in height have one single point catch and lock plus a quarter-turn fastener at the top and at the bottom of the door. A directory card and transparent holder is provided on the inside of the door. P&S-PRLIa rev I Meadows Electric, Inc. 2730 Clydo Road Jacksonville, FL 32207 (904) 367-0676 Lighting Submittals Atlanti* c Beach C I* ty . Hall AppROVED CITV OF ATLANTIC BEACH BUILDING OFFICE CONSOLIDATED ELECTRICAL& DATACOM PRODUCTS D C 0 12004 2365 DENNIS ST. oil 1;fL JACKSONVILLE. FL 32204 (904) 356-9000 RECEIVED Genlyte Lightolier 2955 Hadley Road NOV 0 8 2004 Jacksonville,Florida 32257 (904) 292-1600 C.C. BORDEN (904) 292-0148 Fax CONSTRUCTION, INC. NUT PHONE: 904-292-1600 LIGHTOLIN FAX: 904-292-0148 2955 HARTLEY RD SUITE 103 JACKSONVILLE, FL 32257 FIXTURE SCHEDULE Project : ATLANTIC BEACH CITY HALL TYPE MFG DESCRIPTION A LIGHTOLIER DPS2Gl8LP332120SO-735F4 B LIGHTOLIER S6132BU B LIGHTOLIER 8021CCLW BE LIGHTOLIER S6132BUEM BE LIGHTOLIER 8021CCLW E LIGHTOLIER LLNUGW Page 1 DEEPCEL Plus DPA2GI 8LP332 Page 1 of 2 2'A' RECESSED FLUORESCENT, 3' DEEP, 18 CELL PARABOLIC LOUVER STATIC OR AIR SUPPLY/RETURN, 3 LAMP T8 OR T12 FEATURES * 5'deep body. * Individual lamp compartments. * 77.6%efficient. * Clean contoured interior. * Eyeleted heat removal vents in fixture ends. * One-piece housing has ribbed construction for added strength. * Black exterior for cooler ballast operating temperature. * Hemmed over side rails for safe handling. * Fixture ends turned-in for safe handling. • Built-in earthquake clips(patent no.5,072,344). • Pre-anodized aluminum parabolic louver. • Vertical grain louver eliminates reflected lamp images on cross baffle. • Spring-loaded rooster head latches. • 18 gauge steel hinges. • Louver frame with integral positive light stop. - Louver has protective film dust guard. MOUNTING METHODS DIMENSIONS exposed T-grid coiling. 13 exposed slot T-grid coiling. =0 0 5 1 (I 27mm) y 1/4'max. Alopa' 1-1/2'max. -_717/8'max. 24'(610mm) Airsupplyslats 6'(152mm) 2'x2-1/2 axess plate with two K O.s (DPA only) 15/16' (7/8'dia.) _X or 1' 24' 9/16' concealed Z-splins coiling. d co ad two directional T c ing.(. as options for play ire') a ay Im 3-1 (89 1/4'max. M MR'min. 1-7/9'max. 39-1/4'(997mm) ML 24-11/16' 3/8* 1 1 —47-31/32'(1218mm) plaster ceilingfflanged. drywall kit.(See options) Type: A Type"G' Support Name: ATLANTIC BEACH CITY HALL Fixture (by others) No.:DPS2G18LP33212OS0-735F4 7J-b -- AT ANTIC BE N i Cat. PS L rat.N:D 2LG18 P33212' Raster Opening Drywall Kit 24-1/8' (See Options) L Lamp(s): 1-1/9� min. D 11 /(trathers) VoltsiBallast: 13/16' Ceiling Opening 15/16' 24-1_1/1 24-5/16'x 48-5/16' Lightolier a Genlyte Thomas Company www.lightolier.com Technical Information:(978)657-7600&Fax(978)658-0595 631 Airport Road,Fall River,MA 02720 9(508)67H131 *Fax(508)674-4710 We reserve the right to change details of design,materials and finish. Q 2002 Genlyte Thomas Group LLC(Lightolier Division) A0902 SECTION 2/Folia G51-0 0 DEEPCEL plus DPA2G1 8LP332 Page 2 of 2 2'x4' RECESSED FLUORESCENT, 3" DEEP, 18 CELL PARABOLIC LOUVER STATIC OR AIR SUPPLY/RETURN, 3 LAMP T8 OR T12 PHOTOMETRY MODEL NO.OPA2G18LP332 Luminaire Efficacy Rating LER-68.6 Watts-85.9 BF-0,89 coefficients of utilization—Zonal cavity method FIF 20 20 20 RC so 50 30 bouldwir RW 70 50 30 50 30 10 50- 30 _10 86 84 81 79 77 75 76 74 73 2 80 75 70 71 67 64 68 65 63 2 3 74 67 61 63 59 56 61 58 55 clu XIIA RR;0012W.6LP33.12CO3 - 4 68 60 54 57 52 48 55 51 48 I—IRkIM,TAM. I NOM MUSM VITA MW VA�=IRTZRIM FIN15H. V P�cArm mm phi��mu"T msIRs.r—c— 5 63 54 48 51 46 42 50 45 42 33.7:3"c——RL �c 26-CM�- 2 32 r�.X­ 6 58 49 42 47 41 37 45 41 37 E 7 54 44 38 42 37 33 41 37 33 8 50 40 34 39 33 30 38 33 29 r .1—1....— 9 47 37 31 36 30 27 35 30 27 45's-M.9 W&" 10 1 44 34 24 -0—0.17 _28 33 28 24 32 28 Me I­RVS M visual comfort probability(VCP)average 100 fc;reflectances 90150120 *J room size coiling height ceiling height A 214 '.'.ic, N.J. 10.2., w L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0 I', "to A". ,1,, 20 20 75 70 67 76 84 80 77 77 11 21.1 1— 2— M. 1.29 20 30 79 74 66 66 86 83 79 75 " !M -1 1111 1111 2191 1111 1111 . .. .. 20 40 82 77 71 66 86 85 82 77 311 20 60 83 79 74 70 86 85 85 80 30 20 79 75 70 75 87 82 77 76 2 6 6 6 5 4 0 30 30 83 78 69 65 09 85 79 73 30 40 86 81 73 66 89 86 82 76 30 60 86 83 76 70 89 86 B4 79 30 80 86 83 79 73 89 86 85 79 40 20 79 75 74 77 87 82 80 76 77 7 16 40 30 151 83 80 73 67 0 89 85 81 74 40 40 85 82 77 69 b 89 86 84 76 40 60 86 83 79 72 89 86 86 79 cis ft�. 40 80 86 83 81 74 89 86 86 79 so 40 100 2 86 83 81 74 .9 89 86 86 79 60 30 1 83 80 73 71 89 85 83 75 60 40 2 85 81 78 72 89 86 85 78 MT. CA,-MW3Q 9 89 87 87 A,"LZ AWT-Ral AVU"AVIIIAGS 86 B4 80 74 so 60 60 A; TU 90-M 60 00 86 U 82 77 89 87 87 80 1144 60 100 86 84 82 77 89 87 87 80 3.0 1190: 11 2: 111: 1 00 40 85 81 711 72 89 86 85 78 A'S 94. W 66 100 60 86 84 80 75 89 87 87 80 100 so 86 84 82 77 89 87 87 80 iOO too 86 84 82 77 89 87 87 81 ORDERING INFORMATION Explanation of Catalog Number Example:DPA2Gl8LP332120O3RF 2 18 P 120 SO VOL AGE: T OPTIONS: TBODYSTYU: C EILIGETYPE: TER LAMP A.Air Supply 0-Grid FINISH*: QUANTrrY 120 or 277 Add appropriate S-Static y-In T bao TILow T Hffb(h) F-F,,,ed NUMBER OF Iridescence LAMPTYPEJ DEEPCEL PLUS FIXTURE no,It: r PARABOLIC: WIDTH tplinp a CELLS: Semi-specular DUAL"V" a ndN ard) REFLECTORS FIXTURE BALLAST TYPE: Pro-anodizod r me 18.3 rows P.r LENGTH: 1&2 Lamp Mag.TI 2 LE aluminum louver T-rIMS'rid'ar of 6 32 T8 0. . 24.3 rows Iridescence <20T D <10THD donal Specular 2 tl concealed T Of 8 W.White Baked ,�(NoE".�l 48') 1&2 Lamp Elec.T8 so H1* 1-3 Lamp Elec.TS 03* H3* (see options) Enamel LOL TS Dimming Ps (1.Champagne Gold *Instant Start Standard OPTIONS&ACCESSORIES (18 cell onl�) Other dimming options.Consult factory, PLASTER FRAME Catalog Number PF24. 735,-'l - & 7-414 ML CONTINUOUS ROW INSTALLATION:For F type fixtures,half-width flanges SPECIFICATIONS(continued) are required between fixtures.Order Catalog Number:S2FCTRIM(each joint). MATERIALS:Chassis parts are die-formed code gauge cold rolled steel. SPLAY TRIM:For T ceiling type only.SUFFIX:CTZ24 S2 SPLAY TRIM. Housing is ribbed for rigidity with side rails hemmed over and housing ends RADIO INTERFERENCE FILTER 120 or 277 volt,50 or 60 Hz.One per fixture turned-in for safe handling.Louver is pre-anodized aluminum(Coilzak(&or standard.SUFFIX:RF equal), ELECTRICAL/W11RING OPTIONS:Consult factory. FINISH:Chassis exterior-black baked polyester enamel.Cavity-white AIR CLOSURE STRIP.SUFFIX:ACS4(factory installed). baked polyester enamel minimum 86%reflectance.Phosphate undercoating. DRYWALL KIT,Order Catalog Number:FK.92X4.Request Folio OA30-10. Louver-4ow iridescence semi-specular anodized vertical grain aluminum CHICAGO PLENUM:SUFFIX:CP. reflector sheet is standard. ELECTRICAL Thermally protected class'P'ballast C.B.M.approved,non PCB. SPECIFICATIONS If K.O.is within 3"of ballast,use wire suitable for at least 90'. PERFORMANCE-In an installation of 3 lamp 32W luminaires in a mom cavity LABELS:I.B.E.W.UL and ULc Listed. ratio of 1,with reflectance of 80%ceiling,50%wall,20%floor, the C.U.shall not be less than.83.To prevent glare the VCP shall not be less ype: A than 73 either lengthwise or crosswise(at 100fc level)arid the average bright- ness at 65'shall not exceed 1869 candelas per square meter To control veiling Lightollier a Genlyte Thomas Company www.lightoliercom reflections,luminaire output in the 30*-90*zone shall not be less than 68.8%. Technical Information:(978)657-7600 R,Fax(978)658-0595 631 Airport Road,Fall River,MA 02720*(508)679-8131 e Fax(508)674-4710 AIR HANDLING(DPA only)side air passages for air supply or air return. Supply air is discharged vertically.Optional side closure strips,Air return is also We reserve the right to change details of design,materials and finish. provided through the lamp compartment through fixture body ends. Q 2002 Genlyte Thomas Group LLC(Lightolier Division) A0902 SECTION 2/Folio 051-0 0 <= Calculitea Compact Fluorescent Open Downlighting 8021 Page I of 2 6" Aperture Triple Tube Vertical Lamp low 5 2 1 4 6 MEM 10" (254mm) 26W 9318' L (14 p5/8* l238 mm) 17.m) 32W 12 314C' 9 7/8" F11 (324mm) (251 mml 3' (76 mm) 0 (DO V0 52 mm)Dia, 1'(25 mm)min Oy 3 1 1/8"(29 mm)max.] 2 118*(54mm)max, mm) 71/4 Ceiling Thickness Ceiling Cutout:6 9116"(167 mm)Dia. Reflector Trim Frame-in Kit Lamp 8021 CCLW Comfort Clear',White Flange S6132SU Electronic 120V-277V 26 or 32W Triple Tube 8021 CCLP Comfort Clear',Polished Flange S6132BCU Universal Dimming 120V-277V 4-Pin(Amalgam) 8021 CCL Comfort ClearT4,Molded Trim Ring S6132BJUM7 Advance Mark7 120V-277V 8021 Add suffix.See options for other finishes. Remodeler Frame-in Kit Lamp 6132BURM Electronic 120V-277V 26 or 32W Triple Tube 4-Pin(Amalgam) Features Options and Accessories(continued) 1. Reflector:16 ga.Alzak'aluminum,50*visual cutoff to lamp and lamp Emergency Ltg.Kit FA EM3E* image,medium distribution.Comfort Clear'low iridescence finish. FA EMV Self-flanged or flangeless with molded white trim ring(field paintable). Fuse(Slow Blow) Add suffix F 2. Socket Cup: Effectively dissipates heat and positions lamp holder. Existing/Thk.Ceiling FA EC6* Snaps onto reflector neck to assure consistently correct optical alignment Emergency Add suffix EM* without tools. Chicago Plenum Use 6132BULC 3. Mounting Frame: Galvanized steel for dry or plaster ceilings.Accepts *See Spec,Sheets:FAEM,FAEC other 6"Triple Tube reflectors(see S6132BU Spec Sheet). Mounting Bars&Accessories;see Specification Sheet MBA. 4. Retaining Springs: Precision-tooled steel friction springs secure reflector Sloped Ceiling Adapters;see Specification Sheet SCA mi to mounting ftame for quick,tool-less installation. 5. Mounting Brackets: 16 ga.steel.Adjust from inside of fixture.Use 3/4"or IC Frame available;see C6CFL32 Specification Sheet. 1 112"lathing channel,112"EMT,or optional mounting bars. Labels 6. Ballast/J-Box: Electronic 120V-277V.UL listed for through branch circuit UL Listed for damp locations. wiring with max of(8)No.12 AWG,90'c supply conductors.Outboard mounted to reduce heat transfer and maintain lamp efficacy and life.Service from below without tools. Alzak'is a registered trademark of ALCOA. Electrical US Patent Pending. Note:For ballast electrical data and latest lamp/ballast compatibility refer to Type: B "Ballast"specification sheet for complete electrical data. Job N- ATLANTIC BEACH CITY HALL S61132BU,S6132BCU:UL listed for through branch circuit wiring with max 1 U/ ICi c S of(8)No.12 AWG,90*C supply conductors. cat-N-:S6132BU/8021 CCLW V 6132BURM:UL listed for No.12 AWG,90'C supply conductors. 7 Options and Accessories Lei (a): I Comfort Clear'Finishes' Other Finishes Notes: Diffuse CCD White WH Champagne Bronze CCZ Pewter CPW 'Specify desired flange.W White,P Polished,Blank-Molded Ring Other Dimming: Lightolier a Genlyte Thomas Company www.lightolier.com S6132BJlMX Advance MarkX,120V S6132BJ1LD3 Lutron Hi-lume*,120V 631 Airport Road,Fail River,MA 02720-(508)679-8131 -Fax(508)674-4710 S6132BJ2MX Advance MarkX,227V S6132BJ2LD3 Lutron Hi-lume*,227V We reserve the right to change details of design,materials and finish. 0 2002 Genlyte Thomas Group LLC(Lightolier Division)-D0204 ou_ CalculiteO Compact Fluorescent Open Downlighting 8021 Page 2 of 2 6" Aperture Triple Tube Vertical Lamp 26W 32W Quick Calculator auick Calculator ROOM SURFACE REFLECTANCE& BOOM SURFACE REFLECTANCES: 60 80%Ceiling;50%Wall;20%Floor 80%Ceiling;50%Wall;20%Floor 50 11110111 Looeses Pw Larg 2400 Lumens Per Lmp RCR.1 (Rm.width=10 x Mtg.Ht.above work plane) 0 RCR-I (Rm.width=10 x Mtg.Ht.above RCR-5 (Rm.width=2xMtg.Ht.abovework plane) RCR-5 (Rm.width=2 x Mtg.HL above v Z 40 501 RCR-10 (Rm.width=Mtg.Ht.above work 5 RCR-10IRm.width=Mtg.Ht.above work plane) 40 30 A �6 30- 20-- 20 - 10 10 20 40 60 80 100 120 10 20 30 40 50 60 70 80 go AREA PER FIXTURE IN SQUARE FEET AREA PER FO(TURE IN SQUARE FEET 3 4 5 6 7 8 1 .9 10 CENTER TO CENTER DISTANCE OF FD(TURES IN FEET CENTER TO CENTER DISTANCE OF FD(TURES IN FEET This tick calculator chan determines the number and spacing of I It,26W M units This&ick calculator chan determines the number and spacing of I It,32W M un with mfort Clearw reflector,for any level of illumination. with mfort CleaP reflector,for any level of illumination Spacing Ratio=1.0 Spacing Ratio =1.1 REPORT NO:LSI 14025 REPORT PREPARED FOR:LIGHTOLIER D4-27-1999 UGHTO UER RECESSED FLUORESCENT LUMINAIRE, REPORTNO:LRL499-9G ZONAL SUMMARY WITH COMFORT CLEAR-REFLECTOR LAMPS: PLT-32 LUMENS:2400 ZONE AVG* ZONAL ONE 26 WATT CPFL GE LAMP, ZONAL SUMMARY DESCRIP.:ODIA X IM HT RECESSED DOWNUGHT DEG. C.P. LUMENS CAT#F26TWVSPX3r)-M ANGLE CP WMENS WITH COMFORTCLEAR-REFLECTOR.VERTICAL 180 0 LUMEN RATING ISOD LMS. 0 775 LAMP. 175 0 0 5 .. 'n 165 0 0 1 0 790 1 55 0 0 15 708 199 85* 145 1 1 20 646 1 35 0 0 25 566 258 751 125 0 1 30 478 115 0 0 35 402 245 105 0 0 40 285 400 65* 95 0 0 45 78 81 90 0 0 50 13 55* 95 1 1 55 4 4 75 1 1 60 2 65 3 3 65 1 2 55 9 8 70 1 800 45*. 45 99 77 75 1 1 35 563 354 80 0 25 904 418 51 0 85 0 0 15 1063 301 Nq 90 0 5 1066 102 111111111101 pw- 65. 55- 4'-. 35, 0 1035 ZONAL LUMENS AND PERCENTAGES 1200 ZONAL LUMENS AND PERCENTAGES ZDNE LLXXNS %LAMP %LUMINAK N A 7 0 0-30 533 29.66 61.66 FO-5- '15- 25* ZOK U)MENS %LAMP %LUMINAIAE 0-40 778 43.25 99.92 0-30 821 342 64*9 0-60 863 47.8 99.75 -EFFICIENCY-52.7%- 0-40 1 175 49.0 92'9 -90 865 0 too.00 0-60 1260 52.5 99.6 0 481 1 40-90 87 4.85 10. DATE:4-27-99 0-90 265 52.7 100.0 60-90 2 .12 25 CIE TYPE DIRECT 40-W 90 3.8 7.1 1fFFllClENCY-4&I%1- 90-190 0 .00 .00 LUMINOUS DIAMETER:6.000 60-90 5 0.2 OA DATE:4-23 99 0-180 865 48.10 100.00 THIS REPORT BASED ON LM-I AND 90-120 0 0.0 0.0 CIE TYPE DIRECT OTHER PERTINENT IES PROCEDURES. 90-150 0 0.0 0.0 90-480 0 0.0 0.0 LUMINOUS DIAMETER:6.000 0-180 1265 52.7 100.0 ML THIS REPORT BASED ON LM-I AND OTHER PERTINENT IES PROCEDURES. Coefficients of Utilization Coefficients of Utilization EFFECTIVE FLOOR CAVITY REFLECTANCE=.20 EFFECTIVE FLOOR CAVITY REFLECTANCE=.20 80 70 1 50 1 30 to WALL REFLECTANCE 80 70 1 50 1 30 to 50 30 10 50 30 10150 30 10 50 30 10 50 30 10 0 WALL REFLECTANCE 1 .59.58.57 -58.57.51 .56.55.54 .54.53 .53 .52.52.51 .50 1% 50 30 10 50 30 10150 30 10 50 30 10 50 30 10 0 2 .56.54.53 .55.54.52 .54.52.51 .52.51 .50 .51.50.49 .48 1 .54.53.52 i3 .52.51.51.50 .49.49.48 .48 47.47 .46 .46 3 .53.51.50 .53.51.49 .51.50.49 .50.49 .48 .49.48.47 .46 %10 2 .50.49..47 iO .48.47.48.47 .46.47.46 .45 45.45 .44 .43 4 51 41,47 50,41,46 49,47*41 .48.46 .45 .47.46.45 .44 3 .47.45 44 17 .45.43.46 A4 .43.44.43 .42 43.42 .41 .41 5 .48.46.44 .48.45.44 .47.45.43 .46 A4 .43 .45.44.43 .42 4 .45.42.40 t4 .42.40.43.4 1 AD 42.41 .39 11 .40 .39 38 6 .46.43.42 .46.43.41 .45.43.41 .44.42 .41 .44.42.41 .40 5 .42.39.37 12 .39.37.41.39 .37.40.38 .37 39.38 .36 36 7 .44 .41.39 .43.41.39 .43.41.39 .42.40 .39 .42.40.39 .39 6 .40.37.35 39 .37.35.39.36 .35.38.36 .34 37.36 .34 34 8 .41 .39.37 41 39 37 41 38 37 .40.38 .37 .40.38.36 .36 7 .37.34.33 7 .34.32.36.34 .32.36.34 .32 35.33 .32 31 9 .39.36.35, �39 36�35 1�38 36�35 .38.36 .34 .38.36.34 .34 8 35.32.3 32 30 34 32 .30.34.31 .30 33.31 .30 29 10 _35.32 31 .35.32.311.35.32.30..34.32 .30 34.21L�3�030 0 0 9 .33.3 .28 �30�28132�30 .28.32.29 .28 31 .29 .28 27 10 1.31 2..26 28.26130.2 .26.30.27 .26 ?9.27 .26,25 Wns -,72Mf*j&it�lllllllllll Type: Lightoli0f a Genlyte Thomas Company www.lightalier.com 631 Airport Road,Fall River,MA 02720 e(508)679-8131 *Fax(50B)674-4710 We reserve the right to change details of design,materials and finish. 0 2004 Genlyte Thomas Group LLC(Lightolier Division)*D0204 0W_ 0 <= Calculite' Compact Fluorescent Open Downlighting 8021 Page 1 of 2 6" Aperture Triple Tube Vertical Lamp ?01W 5 2 1 4 6 (254mm) 9 L (238 mm) 4 05/8'" 1 (117mm) 32W 12 3/4' 9 7/8' (324mm) (251 mm) 3' (76 mmi a 0 6*0 52 mm)Dia. 11/8"(29 mm)max 1"(25 mm)min Ova'Ia;� 3 Ceiling Thickness 2 1/8*(54 mm)max, mm) 71/4'(184 Ceiling Cutout 6 9116"(167 mm)Dia. Reflector Trim Frame-in Kit Lamp 8021 CCLW Comfort ClearTv,White Flange S6132BU Electronic 120V-277V 26 or 32W Triple Tube 8021 CCLP Comfort Clearn`,Polished Flange S6132BCU Universal Dimming 120V-277V 4-Pin(Amalgam) 8021 CCL Comfort Clearlm,Molded Trim Ring S6132BJUM7 Advance Mark7 120V-277V 8021 Add suffix.See options for other finishes. Remodeler Frame-In Kit Lamp 6132BURM Electronic 120V-277V 26 or 32W Triple Tube 4-Pin(Amalgam) Features Options and Accessories(continued) 1. Reflector:16 ga.Alzak'aluminum,50*visual cutoff to lamp and lamp Emergency Ltg.Kit FA EM3E* image,medium distribution.Comfort Clearlv low iridescence finish. FA EM4* Self-flanged or flangeless with molded white trim ring(field paintable). Fuse(Slow Blow) Add suffix F 2. Socket Cup: Effectively dissipates heat and positions lamp holder. Existing[Thk.Ceiling FA EC6* Snaps onto reflector neck to assure consistently correct optical alignment Emergency Add suffix EM* without tools. Chicago Plenum Use 6132BULC 3. Mounting Frame: Galvanized steel for dry or plaster ceilings.Accepts *See Spec.Sheets:FAEM,FAEC other 6"Triple Tube reflectors(see S6132BU Spec Sheet). Mounting Bars&Accessories:see Specification Sheet MBA. 4. Retaining Springs: Precision-tooled steel friction springs secure reflector Sloped Ceiling Adapters;see Specification Sheet SCA. to mounting ftame for quick,tool-less installation. IC Frame available;see C6CFL32 Specification Sheet. 5. Mounting Brackets: 16 ga.steel.Adjust from inside of fixture.Use 3/4"or 1 112"lathing channel,112"EMT,or optional mounting bars. Labels 6. Ballast/J-Box: Electronic 120V-277V.UL listed for through branch circuit UL Listed for damp locations. wiring with max of(8)No.12 AWG,90%supply conductors.Outboard mounted to reduce heat transfer and maintain lamp efficacy and life.Service from below without tools. Alzak'is a registered trademark of ALCOA. Electrical US Patent Pending. Note:For ballast electrical data and latest lamp/ballast compatibility refer to Type: BE "Ballast"specification sheet for complete electrical data. Job N-ATLANTIC BEACH CITY HALL S61328U,S61328CU:UL listed for through branch circuit wiring with max 71 02 C S of(8)No.12 AWG,90*C supply conductors, at-N-:S613 2B7tUJEM 8021 CCLW c t 6132BURM:UL listed for No.12 AWG,90'C supply conductors. 7 Options and Accessories L-- (a): Comfort Clear'Finishes! Other Finishes Notes: Diffuse CCD White WH Champagne Bronze CCZ Pewter CPW 'Specify desired flange.W White,P Polished,Blank-Molded Ring Other Dimming: Lightolier a Genlyte Thomas Company www.lightolier.com S6132BJlMX Advance MarkX,120V S61328.11LD3 Lutron Hi-lume',120V 631 Airport Road,Fall River,MA 02720- (508)679-8131 Fax(508)674-4710 S6132BJ2MX Advance MarkX,227V S6132B.12LD3 Lutron Hi-lumea,227V We reserve the right to change details of design,materials and finish. 0 2002 Genlyte Thomas Group LLC(Lightolier Division) DOZ04 ou_ <= CalculiteO Compact Fluorescent Open Downlighting 8021 Page 2 of 2 6" Aperture Triple Tube Vertical Lamp 26W 32W Cluick Calculator auick Calculator 60 ROOM SURFACE REFLECTANCES: 80 ROOM SURFACE REFLECrANCES: 80%Ceiling;50%Wall;20%Floor 80%Ceiling,50%Wall;20%Floor 18ODLmiiirwiiiisP9rLamp 70- 2400L=ensPerL=p 50 RM-1 (Rm.width=10 x Mtg.Ht.above work plane) C4 60 RCR-I (Rm.width=10 x Mtg.Ht.above, C, PA-5 (Rm.width=2 x Mtg.Ht.above wo rk plane) �j RCR-5 (Rm.width=2 x Mtg.HL above v Z 40 RCR-IO(Rm.width=Mtg.Ht.above work plane) @ 50 RCR-10 (Rm.width=Mtg.Ht.above work 30- U. 30- 20 20- 10 20 40 6b I� 100 120 10 20 30 40 50 60 70 80 90 AREA PER FIXTM IN SQUARE FEET AREA PER FIXTURE IN SQUARE FEET 3 4 5 6 7 8 9 10 1 10 1 1 1 CENTER TO CENTER DISTANCE OF FIXTURES IN FEET CENTER TO CENTER DISTANCE OF FIXTURES IN FEET This k calculator chart determines the number and spacing of 1 It.-26W M units This?ick calculatorchart determines the number and spacing of 1 It.-32W M un with8mcfort Clear"m reflector,for arvy level of illumination. with omfort Clearn'reflector,for any level of illumination Spacing Ratio= 1.0 Spacing Ratio = 1.1 REPORT NO:LS1 14025 1 EPORT PREPARED FOR:LIGHTOLIER 04-27-IM LIGHTOLIER RECESSED FLUORESCENT LUMINAIRE, REPORTNO:LRL4999G ZONAL SUMMARY WITH COMFORT CLEAR-REFLECTOR LAMP$: PLT-32 LUMENS:240D ZONE AVG* ZONAL ONE 25 WATT CPFL GE LAMP, ZONAL SUMMARY OESCRIR:ODIA X 10'HT RECESSED OOWNUGHT DEG. C.P. LUMENS CAT#F26TB)(ISPX35-935. ANGLE CP LUMENS WITH COMFORT CLEAR-REFLECTOR.VERTICAL 180 0 LUMEN RATING=IBOOLMS. 0 775 LAMP. 175 0 0 06 77 1 ID 7'80 11555 10 10 15 708 199 85* 145 0 0 20 646 135 0 0 25 566 258 750 125 0 0 30 478 115 0 0 W.. 105 0 0 35 402 245 65* 95 0 40 285 400 00 olow 45 7' 11111 90 0 50 13 55* 85 1 1 55 4 4 75 1 1 60 2 65 3 3 65 1 2 55 1 70 1 BOO 45*1 45 99 77 75 1 1 35 563 354 so 0 25 904 418 51 0 85 0 0 155 1063 301 90 0 1 066 102 35, 0 1035 ZONAL LUMENSANO PERCENTAGES 1200 ZONE LUMENS %LAMP %LUMINAIRE ZONAL LUMENS AND PERCENTAGES 7 0 0-30 533 29.66 61.66 0*5* 1;. 7r. ZONE UAffM %LAMP %LUMINAIRE 0-40 778 43.25 89.92 0-30 921 34.2 64.9 0_60 863 47.98 99.75 -EPFlCU!NCY-5Z7%- 0-40 1175 49.0 92.9 0-90 865 48.10 100.00 0_60 1260 52.5 99.6 40-90 87 4.5 10.08 DATE:4-27-99 0-90 1265 52.7 100.0 -90 8 40-90 90 3.8 7.1 60 2 .12 .25 CIE TYPE DIRECT -EFFICIENCY-4111.1%*1 90-180 0 .00 Do LUMINOUS DIAMETER:6.000 60--90 5 0.2 0.4 DATE:4-23-99 0-180 865 48.10 100.00 THIS REPORT BASED ON LM-1 AND 90-120 0 0.0 0.0 CIE TYPE DIRECT OTHER PERTINENT IES PROCEDURES. 90-150 0 0.0 0'0 90-180 0 0.0 0 LUMINOUS DIAMETER:6.000 0_480 1265 52.7 100*10 ML THIS REPORT BASED ON LM­1 AND OTHER PERTINENT IES PROCEDURES. Coefficients of Utilization Coefficients of Utilization EFFECTIVE FLOOR CAVITY REFLECTANCE=.20 EFFECTIVE FLOOR CAVITY REFLECTANCE=20 80 70 1 50 30 1 10 WALL REFLECTANCE 80 70 1 50 1 30 10 50 30 10 50 30 10150 30 10 150 30 10 50 30 10 0 WALL REFLECTANCE 1 .59.58.57 58 57'56 '56'55.54 .54.53 .53 .52.52.51 .50 50 30 10 50 30 10150 30 10 50 30 10 50 30 10 0 2 .56.54.53 '55'54.52 54.52.51 .52.51 .50 .51 .50.49 .48 1 .54 53 52 53 �52.511.511.50 .49.49.48 .40 47.47 .46 .46 3 .53.51.50 .53.51,49 .51 50.49 .50.49 .48 .49.48 A 7 .46 2 .50'.49'47 50 .48.47.48.47 .46.47.46 .45 45.45 .44 .43 1 4 51 41,47 50,41*41 41,47 A6 48,46 45 *47 46 A5 44 3 .47.45.44 17 .45.43 46.44 .43,44.43 .42 43.42 Al .41 5, 5 .48.46.44 .48.45,44 .47.45.43 .46.44 .43 .45.44.43 .42 4 .45.42.40 14 .42.40 A3.41 .40 42.41 .39 tl .40 .39.38 6 .46.43.42 .46.43.41 .45.43.41 .44.42 .41 .44.42.41 .40 5 .42.39.37 12 39.37.41.39 .37.40.38 .37 39.38 36 36 7 .44 .41.39 .43.41.39 .43.41 M A2.40 .39 .42 AD.39 .38 6 .40.37.35 39 .37.35.39.36 .35138.36 ..34 37.36 34 34 8 8 .41 .39..37 41 39 37 41 38.37 .40.38 .37 .40.38.36 .36 7 37 34 33 7 .34.32.36.34 .32 36.34 32 35.33 .32 31 9 .39.36 35 �39�36 11�38 36.35 3B.36 .34 .38.36.34 .34 8 35 32�30 32 30 34.32 .30 34.31 .30 33.31 .30 29 10 1.35.32.31 1.35.32.311.35.32.30 1.34.32 .30 134.32.30,.30 8 32.30 .28 32.29 .28 31 .29 .28 27 9 .33.30.2 30'28 1 25 BE 10 _31 .28.26 .28.26 30.28 .26 30.27 .26 Z9.27 .26 Lightolier a Genlyte Thomas Company ype: www.lightoliercom 631 Airport Road,Fall River,MA 02720 0(506)670-8131 o Fax(508)674-4710 We reserve the right to change details of design,materials and finish. 0 2004 Genlyte Thomas Group LLC(Lightolier Division)a D0204 ow_ E LL Series LED Exit Sign LL Page 1 of 1 AC Only or Emergency Operation Thermoplastic Housing The ILL Series Thermoplastic LED Exit is a compact exit sign that blends with modem interiors with its softly rounded corners and universal mounting configuration. The LIL Series is extremely easy to install,and provides years of low cost.efficient 30rvICo. Front View Side View Canopy 7 3" 30.0 t 5.05" 1 112.8 curi) __r 7.5" .15011 (19.0 cm) 0.5 cm) L 1.68" (4.3 cm) Complete Fixture consists of base exit sign. How to Specify. FLL I F 7R F-W-0 SERIES BATTERY FACES LETTER COLOR ST&CIL FACE/ HOUSING COLOR LL=LL Series LED E)dt A=ACOnly I=Single R=Red N-_Nickel Cadmiurn 2=Double I=Green I=Ilacl U=Llniversal W=Wi,e POW Features Code Compliance 1. Illuminadon: Illumination of the exit stencil face is accomplished with long UL 924 listed. lasting,high output Light Emitting Diodes(LEDs).Hot spots and striations are eliminated by the internal"light chamber"especially designed around the Warranty high performance LED array.LEDs and support electronics have an expected Three year full electronics warranty service life of 25 years. Five year full plus five year pro-rated nickel cadmium battery warranty 2. Housing: Constructed of impact resistant,UL 94 V-0,5 VA white or black thermoplastic.NFPA-type field selectable chevrons can be installed/removed from outside the exit housing.Housing design simplifies installation,and does not require hard wire terminations inside of the exit housing,Product can also be ceiling mounted to a standard junction box by using the mounting canopy supplied. 3. Electronics: 120/277 VAC dual voltage input with surge-protected,solid- state circuitry.Charging system is complete with low voltage disconnect,AC lockout,brownout protection,AC indicator lamp and test switch. 4. Battery: Maintenance free,sealed nickel cadmium battery has an estimated Type: E service life of 10 years,and an operating temperature range of 201(-7'C)to 951(35'C). Job Namew ATLA�NTIC BEACH CITY HALL 5. Input Power Requirements: AC Only-Red:.93 W,Green:.72 W at.No.. Emergency Operation-Red:1.55 W,Green:1.85 W Cat-NO-LLNUGW 7c Larnp(s): Notes: Lightolier a Genlyte Thomas Company www.lightolier.com 631 Airport Road,Fall River,MA 02720 e(508)679-8131 &Fax(508)674-4710 We reserve the right to change details of design,materials and finish. Q 2002 Genlyte Thomas Group LLC(Lightolier Division)*80902 0U_ �wv lavid �wu 0' 14121631 lilt �co) 42-- Willi