Application Number . . . . . 13-00001934 Date 1/03/13
Property Address . . . . . . 501 CRUISER LN
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
----------------------------------------
Application desc
Replace 1 cu 1 ahu
----------------------------------------
Owner Contractor
-
------------------------
-----------------------
DALTON, NANCY ONE HOUR AIR
501 CRUISER LANE 1015 ATLANTIC BLVD #249
ATLANTIC BEACH FL 32233 ATLANTIC BEACH FL 32233
(904) 241-5780 (904) 222-8482
---------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . . REPLACE 1 CU 1 AHU . 00
Permit Fee 99 . 00 Plan Check Fee .
Issue Date . . . Valuation 0
Expiration Date . . 7/02/13
__ ------------------------------
Other Fees .
. STATE MECH DCA SURCHARGE 2 . 0
STATE MECH DBPR SURCHARGE 2 . 00
Fee summary Charged Paid Credited Due
_ ----------
----- ----------
Permit Fee Total 99 . 00 99 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 103 . 00 103 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph(904) 247-5826 Fax(904) 247-5845
JOB ADDRESS: S� I C 2 U t SC'y I—A/V
PERMIT## '
PROJECT VALUE $ S6 S-6)
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATIONARI
,Z
Air Conditioning: Unit Quantity i Tons Per Unit 3REQUIRED
Heat: Unit Quantity ( BTU's Per Unit;::' Seer Rating / 3
Duct Systems: Total CFM REQUIRED
FIRE PREVENTION 3 sets of plans)
Fire Sprinkler System Quantity (Requires
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIREPLACES MISCELLANEOUS:
Prefabricated Fireplace Qty Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Refrigerator Condenser BTU's
#Vented Wall Furnaces Sol ollection Systems
#Water Heaters Tanks (gallons)
Wells
OTHER:
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified
or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
vi
Property Owners Name �� /i��� �4 L 7U/(/ Phone Number 2
Mechanical Company C iLJC� CJ2 / 4 Office Phone2yl��1U7F 2� ��G
Ci C State�Zip
�Y �ZZ�
Co. Address: / 1 � /- �G2—( f20 ZC�
License Holder(Print):
to Certific o e ' ation ��`�y
Notarized Signature of License Holder
Sworn and subscribed before me this da f 20
p�ppAli AMANDA a e of Notary Public
=� My COMMISSION#EE 057 9
An"IfF EXPIRES:May 21,2015
Bonded Thru Notary PoWic Underwriters
P
Project Summa Job:
W rlghtSdft � � Date: 113/2013
CRAIG EDDY
Entire House By
ONE HOUR AIR
1198 MAYPORT RD#1,ATLANTIC BEACH,FL 32233 Phone:904-241-3107 Fax:904-247-5526 License:CAC1814420
Project Information
For: NANCY DALTON
501 CRUISER LANE,ATLANTIC BEACH, FL 32233
Phone: 904-241-5780
Notes:
Design Information
Weather: Jacksonville/Craig, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 35 °F Outside db 91 °F
Inside db 70 °F Inside db 75 °F
Design TD 35 °F Design TD 16 °F
Daily range M
Relative humidity 50 %
Moisture difference 53 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 29053 Btuh Structure 28267 Btuh
Ducts 0 Btuh Ducts 0 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 29053 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 28267 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average Structure
Fireplaces 2990 Btuh
Ducts 0 Btuh
Heating Cooling Central vent(0 cfm) 0 Btuh
Area(ftp 1872 1872 Equipment latent load 2990 Btuh
Volume (ft) 14976 14976
Air changes/hour 0.38 0.20 Equipment total load 31257 Btuh
Equiv.AVF (cfm) 95 50 Req.total capacity at 0.80 SHR 3.0 ton
Heating Equipment Summary Cooling Equipment Summary
Make GOODMAN Make GOODMAN
Trade ONE HOUR AIR Trade ONE HOUR AIR
Model GSZ130361 Cond GSZ130361
AHRI ref 5439792 Coil ARUF361
AHRI ref 5439792
Efficiency 0 HSPF Efficiency 13 SEER
Heating Input Sensible cooling 26301 Btuh
Heating output 0 Btuh @ 47°F Latent cooling 6699 Btuh
Temperature rise 0 °F Total cooling 33000 Btuh
Actual air flow 1287 cfm Actual air flow 1287 cfm
Air flow factor 0.044 cfm/Btuh Air flow factor 0.046 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.90
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2013-Jan-03 06:21:12