Loading...
Permit HVAC 592 Royal Palms Dr 2013 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ...........I, ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00001973 Date 1/10/13 Property Address . . . . . . 592 ROYAL PALMS DR Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu. ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ CARTLIDGE, ELIZABETH R AIR FLOW DESIGNS INC 592 ROYAL PALMS DRIVE PO BOX 180308 ATLANTIC BEACH FL 32233 250 JASMINE RD CASSELBERRY FL 32718 (907) 398-0831 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 91 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 7/09/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 91 . 00 91 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 95 . 00 95 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION jql � CITY OF ATLANTIC BEACH 15 01 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247-5826 Fax (904) 247-5845 JOB ADDRESS: PERMrr 04# PROJECT VALUE —Alb NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Q D Air Conditioning: Unit Quantity Tons Per Unit ARI# 1- 0 Heat: Unit Quantity BTU's Per Unit,er Seer RtafinY �6- 0 Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty_ Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name Phone Number Mechanical Company ,�k z::Y-14A) De1j*g-A1X Office Phone-��-,�Ok�ax 5 -,,9 Co. Address:.Sow,5 .,Ie-T,,I, City State License Holder (Print): o St at:o� ertlification/Registration#e",&,Zi!�6A.., Notarized Signature of License Holder Donna L-Thomason commission#DD60490�Sworn and subscribed befor this day of jV .20 40 Expires '�'4J10-0 Bonaed Troy FaIn-111V'11� November 2,20 tary Publ;��e ,%ignature of No I /A,.- - :�Z wrightsofto Load Short Form Job: CARLIDGE Date: 1/9/13 Entire House By: KMA Air Flow Designs Central LLC 250 Jasmine Road,Casselberry,FIL 32707 Phone:407-831-3600 Fax:407-831-4553 Web:www.airflowdesigns.com Project Information For: CARLIDGE Design Information Htg Cig Infiltration Outside db(OF) 33 93 Method Simplified Inside db(OF) 68 75 Construction quality Average Design TD (OF) 36 18 Fireplaces 0 Daily range - M Inside humidity 50 50 Moisture difference(gr/lb) 29 51 HEATING EQUIPMENT COOLING EQUIPMENT Make Carrier Make Carrier Trade BASE 13 PURON HP Trade BASE 13 PURON HP Model 25HBC324(A,W)--30 Cond 25HBC324(A,W)'-30 AHRI ref 3699485 Coil FB4CNF024 AHRI ref 3699485 Efficiency 8 HSPF Efficiency 11.0 EER, 13 SEER Heating input Sensible cooling 18400 Btuh Heating output 22600 Btuh @ 470F Latent cooling 4600 Btuh Temperature rise 27 OF Total cooling 23000 Btuh Actual air flow 767 cfm Actual air flow 767 cfm Air flow factor 0.034 cfm/Btuh Air flow factor 0.042 cfm/Btuh Static pressure 0.50 in H20 Static pressure 0.50 in H20 Space thermostat Load sensible heat ratio 0.86 ROOM NAME Area Htg load CIg load Htg AVF Cig AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) Rooml 1053 22254 18388 767 767 Entire House 1053 22254 18388 767 767 Other equip loads 0 0 Equip. @ 0.98 RSM 17965 Latent cooling 2935 TOTALS 1 1053 1 22254 1 20900 1 767 1 767 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-Jan-09 14:07:43 wrightsOft' Right-SuiteD Universal 2012 12.1.04 RSUC6910 Page 1 GAAFD-Central\CARLlDGE.rup Calc-MJ8 Front Door faces: E Job: CARLIDGE wrightsoft" Building Analysis Date: 1/9/13 Entire House By: KMA Air Flow Designs Central LLC 250 Jasmine Road,Casselberry,FL 32707 Phone:407-831-3600 Fax:407-831-4553 Web:www.airflowdesigns.com Project Information For: CARLIDGE Design Conditions Location: Indoor: Heating Cooling Jacksonville Intl AP, FL, US Indoor temperature(OF) 68 75 Elevation: 33 ft Desi?n TD (T� 36 18 Latitude: 30 ON Rela ilve humi ity 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 29.4 51.2 Dry bulb(OF) 33 93 Infiltration: Daily range�)-F) - 18 ( M Method Simplified Wet bulb (0 - 77 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Component Btuh/ft2 Btuh %of load Walls 4.9 5114 23.0 Glazing 30.9 3799 17.1 Doors 12.0 454 2.0 Ceilings 1.7 1832 8.2 Floors 4.7 4985 22.4 Infiltration 2.6 2772 12.5 Ducts 3299 14.8 Piping 0 0 Humidification 0 0 Ventilation 0 0 Adjustments 0 tal 22254, 100.0 Component Btuh/ft2 Btuh %of load IntefftwGaft Walls 2.6 2719 14.8 w8ft Glazing 44.9 5526 30.1 Doors 10.2 386 2.1 Ceilings 2.6 2771 15.1 Floors 0 0 0 Infiltration 0.7 706 3.8 Ducts 4589 25.0 Ventilation 0 0 Internal gains 1690 9.2 Blower 0 0 1~� Adjustments 0 1 Total 1 1 183881 100.0 Dws Latent Cooling Load 2935 Btuh Overall U-value=0.138 Btuh/ft2-OF Data entries checked. 2013-Jan-09 14:07:43 wrilghtsoft Right-SuiteD Universal 2012 12.1.04 RSU0691 0 Page I ,O� GAAFD-Central\CARLlDGE.rup Calc-MJ8 Front Door faces: E Component Constructions Job: CARLIDGE wrightsoft- Date: 1/9/13 Entire House By: KMA Air Flow Designs Central LLC 250 Jasmine Road,Cassel berry,FL 32707 Phone:407-831-3600 Fax:407-831-4553 Web:www.a!Olowdesigns.com Project Information For: CARLIDGE Design Conditions Location: Indoor: Heating Cooling Jacksonville Intl AP, FL, US Indoor temperature(OF) 68 75 Elevation: 33 ft Design TD (OF) 36 18 Latitude: 30 ON Relative humidity 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 29.4 51.2 Dry bulb(OF) 33 93 Infiltration: Daily range(OF) - 18 ( M Method Simplified Wet bulb(OF) 77 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss ClIg HTM Galn ft� Btuh/ftg-*F ft�F/Btuh BtuhA2 Btuh Btuh/ft2 Stuh Walls 13A-4ocs:Blk wall,stucco ext,r-4 ext bd ins,8"thk,1/2"gypsum board n 213 0.143 4.0 5.08 1081 2.72 579 int fnsh e 184 0.143 4.0 5.08 934 2.72 500 S 201 0.143 4.0 5.08 1020 2.72 546 w 330 0.143 4.0 5.08 1675 2.72 897 all 928 0.143 4.0 5.08 4710 2.72 2521 Partitions 12B-Osw:Frm wall,3/8"wood shth,r-1 1 cav ins,1/2"gypsum board int 117 0.097 11.0 3.44 403 1.69 198 f nsh,2"x4"wood f rm Windows 1 D-c2om:2 glazing,clr outr,air gas,mtl no brk frm mat,cir innr,1/4" n 30 0.870 0 30.9 927 24.8 745 gap,1/8"thk;50%blinds 45*,medium;1 ft overhang(5 ft Window ht,1 e 30 0.870 0 30.9 927 65.5 1965 ft Sep.) S 15 0.870 0 30.9 463 25.4 381 W 30 0.870 0 30.9 927 65.5 1965 all 105 0.870 0 30.9 3243 48.2 5057 1 D-c2om:2 glazing,clr outr,air gas,mtl no brk frm mat,clr innr,1/4" S 18 0.870 0 30.9 556 26.1 470 gap,1/8"thk;50%blinds 451,medium;1 ft overhang(6 ft Window ht,1 ft Sep.) Doors 11 PO:Door,mtl pur core type a 20 0.290 10.5 10.3 207 8.76 176 11 DO:Door,wd sc type n 18 0.390 0 13.8 247 11.8 210 Ceilings 16B-19ad:Attic ceiling,asphalt shingles roof mat,r-19 cell ins,1/2" 1053 0.049 19.0 1.74 1832 2.63 2771 gypsum board int fnsh Floors 22A-cpm:Bg floor,heavy dry or light damp soil,on grade depth,carpet 119 1.180 0 41.9 4985 0 0 flr fnsh ,t:� 2013-Jan-0914:07;43 * wrightsoft' Right-SuiteS Universal 2012 12.1.04 RSU0691 0 Page I JOM G:\AFD-Central\CARLIDGE.rup Calc-MJ8 Front Door faces: E Job: CARLIDGE wrightsoft, Project Summary Date: 1/9/13 Entire House By: KMA Air Flow Designs Central LLC 250 Jasmine Road,Casselberry,FL 32707 Phone:407-831-3600 Fax:407-831-4553 Web:www.ai0lowdesigns.com Project Information For: CARLIDGE Notes: Design Information Weather: Jacksonville Intl AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 33 OF Outside db 93 OF Inside db 68 OF Inside db 75 OF Design TD 36 OF Design TD 18 OF Daily range M Relative humidity 50 % Moisture difference 51 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 18956 Btuh Structure 13799 Btuh Ducts 3299 Btuh Ducts 4589 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 22254 Btuh Use manufacturer's data n Rate/swing multiplier 0.98 Infiltration Equipment sensible load 17965 Btuh Method Simplified Latent Cooling Equipment Load Sizing Constructionquality Average Fireplaces 0 Structure 1862 Btuh Ducts 1073 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft2) 1053 105 Equipment latent load 2935 Btuh Volume (ft3) 9477 9477 Air changes/hour 0.45 0.23 Equipment total load 20900 Btuh Equiv.AVF(cfm) 71 36 Req.total capacity at 0.80 SHR 1.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade BASE 13 PURON HP Trade BASE 13 PURON HP Model 25HBC324(A,W)"30 Cond 25HBC324(A,W)"30 AHRI ref 3699485 Coil FB4CNF024 AHRI ref 3699485 Eff iciency 8 HSPF Efficiency 11.0 EER, 13 SEER Heating input Sensible cooling 18400 Btuh Heating output 22600 Btuh @ 47 OF Latent cooling 4600 Btuh Temperature rise 27 OF Total cooling 23000 Btuh Actual air flow 767 cfm Actual air flow 767 cfm Air flow factor 0.034 cfm/Btuh Air flow factor 0.042 cfm/Btuh Static pressure 0.50 in H20 Static pressure 0.50 in H20 Space thermostat Load sensible heat ratio 0.86 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-Jan-09 14:07:43 wrightsoft, Right-SuiteS Universal 2012 12.1.04 RSU0691 0 Page I GAAFD-Central\CARLlDGE.rup Calc-MJ8 Front Door faces: E wrightsoft, Right-JO Worksheet Job: CARLIDGE Entire House Date: 1/9/13 By: KMA Air Flow Designs Central LLC 250 Jasmine Road,Casselberry,FIL 32707 Phone;407-831-3600 Fax:407-831-4553 Web:www.airflowdesigns.com 1 Room name Entire House Rooml 2 Exposed wall 119.0 ft 119.0 It 3 Room height 9.0 It 9.0 It heat/cool 4 Room dimensions 1.0 x 1053.0 It 5 Room area 1053.0 ft2 1053.0 ft2 Ty Construction U-value Or HTM Area (ft� Load Area (ft� Load number (Btuh/ft2-1F) (Btuh/ft� or perimeter (ft) (Stuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs 0.143 n 5.08 2.72 243 213 1081 579 243 213 1081 579 1 D-c2om 0.870 n 30.89 24.83 30 0 927 745 30 0 927 745 1 3A-40cs 0.143 e 5.08 2.72 234 184 934 Soo 234 184 934 Soo ID-c2orn 0.870 e 30.89 65.51 30 0 927 1965 30 0 927 1965 I 11PO 0.290 e 10.30 8.76 20 20 207 176 20 20 207 176 T::43A-40cs 0143 s 5.08 2.72 234 201 1020 546 234 201 1020 546 11 D-c2om 0:870 a 30.89 25.40 15 13 463 381 15 13 463 381 1 D-c2om 0.870 a 30.89 26.09 18 13 556 470 18 13 556 470 13A-4ocs 0.143 w 5.08 2.72 360 330 1675 897 360 330 1675 897 t--G 1 D-c2orn 0.870 w 30.89 65.51 30 0 927 1965 30 0 927 1965 1213-0sw 0.097 - 3.441 1.69 135 117 403 198 135 117 403 198 1--D 11DO 0.390 n 13.84 1! 11.78 18 18 247 210 18 18 247 210 C 16B-1 9ad 0.049 1.74 2.63 1053 1053 1832 2771 1053 1053 1832 2771 F 22A-cpm 1.180 41.89 0.00 1053 119 4985 0 1053 119 4985 0 6 c)AED excursion 0 0 Envelope loss/gain 16184 11402 16184 11402 12 a) Infiltration 2772 706 2772 706 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 3 690 3 690 Appliances/other 10001 1000 Subtotal(lines 6 to 13) 18956 13799 18956 13799 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 18956 13799 18956 13799 15 Duct loads 1 179/6 33% 3299 4589 17%1 33% 3299 4589 Total room load 22254 18388 22254 18388 Air required(cfm) 1 767 7671 1 7671 767 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -rij- vvrilghtsc),ftl 2013-Jan-09 14:07:43 Right-SuiteD Universal 2012 12.1.04 RSU0691 0 Page 1 'M AC G:\AFD-Contral\CARLIDGE.rup Calc-W8 Front Door faces: E Job: CARLIDGE wrightsoft AED Assessment Date: 1/9/13 Entire House By: KNIA Air Flow Designs Central LLC 250 Jasmine Road,Casselberry,FL 32707 Phone:407-831-3600 Fax:407-831-4553 Web:www.airflowdesigns.com Project Information For: CARLIDGE Design Conditions Location: Indoor: Heating Cooling Jacksonville Intl AP, FL, US Indoor temperature(OF) 68 75 Elevation: 33 ft Design TD (OF) 36 18 Latitude: 30 ON Relative humidity 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 29.4 51.2 Dry bulb(OF) 33 93 Infiltration: Daily range(OF) - 18 M Wet bulb(OF) - 77 Wind speed(mph) 15.0 7.5 Test for Adequate Exposure Diversity Hourly Glazing Load 8,000-- 7,000-- 6,000-- 5,000- 4,000-- 3,000-- 2,000-- 1,000-- 0 8 9 10 11 12 13 14 15 16 17 18 19 20 Hour of Day dF Hourly ,or Average AED limit Maximum hourly glazing load exceeds average by 20.4%. House has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh 2013-Jan-09 14:07:43 wrightsoft, Plight-S,iteM Universal 2012 12.1.04 RSU0691 0 Page 1 AM GAAM-CentraRCARLIDGE.rup Calc.W8 Front Door faces: E 0%Ulm 003 CERTIFIEDTM J www.a h rid ire cto ryiq rg A Certificate of Product Rationgs AHRI Certified Reference Number: 3699485 Date: 1/10/2013 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 25HBC324(A,W)**30 Indoor Unit Model Number: FB4CNF024 Manufacturer: CARRIER AIR CONDITIONING Trade/Brand name: BASE 13 PURON HP Manufacturer responsible for the rating of this system combination is CARRIER AIR CONDITIONING Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity(Btuh): 23000 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Heating Capacity(Btuh)@ 47 F: 22600 Region IV HSPF Rating (Heating): 8.00 Heating Capacity(Btuh)@ 17 F 13600 Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.aliridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org, "IMP, Air-Conditioning,Heating, click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on 0%0 On ILI and Refrigeration Institute which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. 02012 Air-Conditioning,Heating,and Refrigeration Institute CERTIFICATE NO.: 130023077629860971