Loading...
Permit HVAC 1731 Beach Ave 2013 .�l I , I CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00001997 Date 1/15/13 Property Address . . . . . . 1731 BEACH AVE Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ PARRISH ROBERT B. & FORREST OCEAN STATE HEAT & AIR, INC. 1731 BEACH 1476 ATLANTIC BLVD. ATLANTIC BEACH FL 322335838 NEPTUNE BEACH FL 32266 (904) 249-82S1 ---------------------------------------------------------------------------- Permit MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 103 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 7/14/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 103 . 00 103 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 107 . 00 107 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALI, CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BVIYIDAM,CODES. MECRANTICAL PERMIT APPLICATION CITY OF ATLANTIC 13EACH 800 Seminole Rd Atlantic Beach, FL 322-3.3 Ph (90A) 247-5826 Fax (904) 21T7-584-5 JOB ADDRESS: 1 -7z 1 13,c,�L- --- PERMTT 9 PROJECT VALUE S S' .00 N TW AIR CONDITIONING & HEATING SYSTEM LNTSTALLATION AL- Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTUs Per Unit Seer Ratina Duct Systems: Total CFM REO UTRED REPLACE-KENT AIR CONDITIONrLNG & ]HE,ATING SYSTEM LNSTALLATION AR1# szrmioi Air Conditioning: Unit Quantity I Tons Per Unit 3 REQ117kED Heat: Unit Quantity BTU's Per Unit z Seer Ratina 1,3 Duct Systems: Total CFM REOLTIRED FIRE PREVEINITIONT Fire SprinU- eer System Quantity (Requires 3 sets of plans) Fire Standpipe . Quantity (Requires 3 sets of plans) UndergoTound Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Con-iniercial Hoods Quantity (Requires 31 sets of plans) Fire Suppression Systerns Quantity ('Requires 3 sets of pians) FIRE PLACES MISCELLAINT, OUS: Prefabricated Fireplace Q-L:,- Automobile Lifts (I Boilers BTI-T's Gas Piping Outlets Elevators�—P scalaLors 'G kLL OTHER GAS PIFLN Heat Exchariger Quantity of Outlets Pumps T', Vented Wall Furnaces Refrigerator Condenser BTU's 4 Water Heaters Solar Collection Systems Tanks (gallons) Well S OTHER: Permit bcoomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I herein,cerdfv that I have read Us application and know the same to be true and correct. All provisions ofla-ws and ordinaDees governing this work-will be complied with whether spec.ifled or not. Th�,permit does no',givc authornty to violate the provisions of any othe�,-state or local law regulation construction o7 the perforinance-of consxucuon. 11roperty 0,,Nmers Nairi�- 12,0 PC-rri3-1. PhoncNturrtber ?-Y(. -,30(D2 , ? — 8W? flice Phone Fax Mechanical Company 6L,C". _ '71-1�1 Co. Address: IV-76 citv IN �U, afe-ei- Statefi- Zipjz-,,-i-� License Holder (Print): St Certification/Registration -141 Notarized Signature of License Holde c p p Ci Iq �Ijl St Certificat ense ffo)lde 'iC Sw 4u - -1 scrib- ore me this day of 201 ............ Swo s yv5TTr.P.MORALES PU17� of,T lie j,T 1� -ure .,Oe M#()DO860534 7"- e of T A cam ignatur wy Publi _0 IAA, A-A A V I Exores 312/2013 Inc Vioride Notary Assn .............. Lifia 0 ACCA Manual "J" Heat Load Calculation Date 01/15/13 Customers Name Parrish Location Atlantic Beach Type of Construction Heat Transfer Multipliers Area or BTUH Exposure Notes HEATING COOLING Length HEATING COOLING 1 Gross Wall 1,561 2,3 Windows North Al, N, 2 29.0 16.0 15 435 240 East& West Al, E&W, 2 29.0 46.0 112 3,248 5,152 South Al, S, 2 29.0 25.0 20 580 500 4 Doors Front Solid Wood - Panel 27.0 15�8 30 810 474 Patio Solid Wood -Storm 16.4 9,7 60 984 582 Other SIdg GI Dr, S, 2 32.6 25.0 0 0 0 5 Net Wall Area I R- 11, 1/2"Asp. l3rd. 3.2 1�9 1,424 4,557 2,706 Area 2 R- 13, 1/2"Asp. l3rd. 3.0 1�8 0 0 Area 3 R- 13, 1/2"Asp. l3rd. 3.0 1.8 0 0 6 Ceilings Area I Attic, R-22 1.9 2.1 1,561 2,966 3,278 Area 2 Attic, R- 19 2.1 2,3 0 0 Area 3 Attic, R- 19 2.1 2,3 0 0 7 Floors Area I Slab 40�5 0.0 167 6,764 0 Area 2 None 0.0 U 0 0 8 Infiltration Winter Summer Avg Cilng Ht Poor 1500-2100 1.2 0.6 9 14,485 11,097 9 Sub Total BTUH Loss 34,828 10 Duct BTUH Loss 3,483 11 TOTAL HEATING LOAD 38,311 12 People and Appliances Bedrooms 3 3,000 13 -Sub Total BTUH Gain (Structure) 14 Duct BTUH Gain Location Attic 15% 4,054 15 TOTAL SENSIBLE 1 31,083 16 Infiltraton Latent Gain Infit. CFM 141 4,882 17 People Latent Gain #People 4 2,400 19 TOTAL LATENT 7,282 19 Total Cooling Load 38,365 A; CERTIFIEDT" L: www.aliridirectory.org Certificate of Product Ratings AHRI Certified Reference Number: 5201061 Date: 1/9/2013 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number:YHJR42S41S4 Indoor Unit Model Number: AV*48 Manufacturer: YORK BY JOHNSON CONTROLS Trade/Brand name: LX SERIES Manufacturer responsible for the rating of this system combination is YORK BY JOHNSON CONTROLS Rated as follows in accordance with AHRI Standard 2101240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity(Btuh): 39500 EER Rating (Cooling): 10.95 SEER Rating (Cooling): 13.00 Heating Capacity(Btuh)@ 47 F 38500 Region IV HSPF Rating (Heating): 8.75 Heating Capacity(Btuh)@ 17 F 23400 Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance ofthe product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products ofAHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents ofthis Cerbficate may not,in whole or in part be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION The information forthe model cited onthi:s certificate can be verified atwww.ahridirectory.org, "IMP, -Conditioning,Heating, click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on iliiiu Air which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. and Refrigeration Institute @2012 Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO.: 130022339782490133