Permit HVAC 1731 Beach Ave 2013 .�l I , I
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 13-00001997 Date 1/15/13
Property Address . . . . . . 1731 BEACH AVE
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
1 cu 1 ahu
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
PARRISH ROBERT B. & FORREST OCEAN STATE HEAT & AIR, INC.
1731 BEACH 1476 ATLANTIC BLVD.
ATLANTIC BEACH FL 322335838 NEPTUNE BEACH FL 32266
(904) 249-82S1
----------------------------------------------------------------------------
Permit MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee . . . . 103 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 7/14/13
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 103 . 00 103 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 107 . 00 107 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALI, CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BVIYIDAM,CODES.
MECRANTICAL PERMIT APPLICATION
CITY OF ATLANTIC 13EACH
800 Seminole Rd Atlantic Beach, FL 322-3.3
Ph (90A) 247-5826 Fax (904) 21T7-584-5
JOB ADDRESS: 1 -7z 1 13,c,�L- --- PERMTT 9
PROJECT VALUE S S' .00
N
TW AIR CONDITIONING & HEATING SYSTEM LNTSTALLATION
AL- Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTUs Per Unit Seer Ratina
Duct Systems: Total CFM REO UTRED
REPLACE-KENT AIR CONDITIONrLNG & ]HE,ATING SYSTEM LNSTALLATION
AR1# szrmioi
Air Conditioning: Unit Quantity I Tons Per Unit 3 REQ117kED
Heat: Unit Quantity BTU's Per Unit z Seer Ratina 1,3
Duct Systems: Total CFM REOLTIRED
FIRE PREVEINITIONT
Fire SprinU- eer System Quantity (Requires 3 sets of plans)
Fire Standpipe . Quantity (Requires 3 sets of plans)
UndergoTound Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Con-iniercial Hoods Quantity (Requires 31 sets of plans)
Fire Suppression Systerns Quantity ('Requires 3 sets of pians)
FIRE PLACES MISCELLAINT, OUS:
Prefabricated Fireplace Q-L:,- Automobile Lifts
(I Boilers BTI-T's
Gas Piping Outlets Elevators�—P scalaLors
'G
kLL OTHER GAS PIFLN Heat Exchariger
Quantity of Outlets Pumps
T', Vented Wall Furnaces Refrigerator Condenser BTU's
4 Water Heaters Solar Collection Systems
Tanks (gallons)
Well S
OTHER:
Permit bcoomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I herein,cerdfv that I have read
Us application and know the same to be true and correct. All provisions ofla-ws and ordinaDees governing this work-will be complied with whether spec.ifled
or not. Th�,permit does no',givc authornty to violate the provisions of any othe�,-state or local law regulation construction o7 the perforinance-of consxucuon.
11roperty 0,,Nmers Nairi�- 12,0 PC-rri3-1. PhoncNturrtber ?-Y(. -,30(D2
, ? — 8W?
flice Phone Fax
Mechanical Company 6L,C". _ '71-1�1
Co. Address: IV-76
citv IN �U, afe-ei- Statefi- Zipjz-,,-i-�
License Holder (Print): St Certification/Registration -141
Notarized Signature of License Holde
c p
p
Ci Iq �Ijl
St Certificat
ense ffo)lde
'iC Sw 4u
- -1 scrib- ore me this day of 201
............ Swo s
yv5TTr.P.MORALES
PU17�
of,T lie
j,T
1� -ure .,Oe
M#()DO860534 7"- e of T A
cam ignatur wy Publi _0 IAA, A-A A
V I
Exores 312/2013
Inc
Vioride Notary Assn
..............
Lifia 0
ACCA Manual "J" Heat Load Calculation Date 01/15/13
Customers Name Parrish Location Atlantic Beach
Type of Construction Heat Transfer Multipliers Area or BTUH
Exposure Notes HEATING COOLING Length HEATING COOLING
1 Gross Wall 1,561
2,3 Windows
North Al, N, 2 29.0 16.0 15 435 240
East& West Al, E&W, 2 29.0 46.0 112 3,248 5,152
South Al, S, 2 29.0 25.0 20 580 500
4 Doors
Front Solid Wood - Panel 27.0 15�8 30 810 474
Patio Solid Wood -Storm 16.4 9,7 60 984 582
Other SIdg GI Dr, S, 2 32.6 25.0 0 0 0
5 Net Wall
Area I R- 11, 1/2"Asp. l3rd. 3.2 1�9 1,424 4,557 2,706
Area 2 R- 13, 1/2"Asp. l3rd. 3.0 1�8 0 0
Area 3 R- 13, 1/2"Asp. l3rd. 3.0 1.8 0 0
6 Ceilings
Area I Attic, R-22 1.9 2.1 1,561 2,966 3,278
Area 2 Attic, R- 19 2.1 2,3 0 0
Area 3 Attic, R- 19 2.1 2,3 0 0
7 Floors
Area I Slab 40�5 0.0 167 6,764 0
Area 2 None 0.0 U 0 0
8 Infiltration Winter Summer Avg Cilng Ht
Poor 1500-2100 1.2 0.6 9 14,485 11,097
9 Sub Total BTUH Loss 34,828
10 Duct BTUH Loss 3,483
11 TOTAL HEATING LOAD 38,311
12 People and Appliances Bedrooms 3 3,000
13 -Sub Total BTUH Gain (Structure)
14 Duct BTUH Gain Location Attic 15% 4,054
15 TOTAL SENSIBLE 1 31,083
16 Infiltraton Latent Gain Infit. CFM 141 4,882
17 People Latent Gain #People 4 2,400
19 TOTAL LATENT 7,282
19 Total Cooling Load 38,365
A; CERTIFIEDT"
L: www.aliridirectory.org
Certificate of Product Ratings
AHRI Certified Reference Number: 5201061 Date: 1/9/2013
Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source
Outdoor Unit Model Number:YHJR42S41S4
Indoor Unit Model Number: AV*48
Manufacturer: YORK BY JOHNSON CONTROLS
Trade/Brand name: LX SERIES
Manufacturer responsible for the rating of this system combination is YORK BY JOHNSON CONTROLS
Rated as follows in accordance with AHRI Standard 2101240-2008 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third
party testing:
Cooling Capacity(Btuh): 39500
EER Rating (Cooling): 10.95
SEER Rating (Cooling): 13.00
Heating Capacity(Btuh)@ 47 F 38500
Region IV HSPF Rating (Heating): 8.75
Heating Capacity(Btuh)@ 17 F 23400
Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate.
DISCLAIMER
AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for,
the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance ofthe product(s),or the
unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org.
TERMS AND CONDITIONS
This Certificate and its contents are proprietary products ofAHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.
The contents ofthis Cerbficate may not,in whole or in part be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any
form or manner or by any means,except for the user's individual,personal and confidential reference.
CERTIFICATE VERIFICATION
The information forthe model cited onthi:s certificate can be verified atwww.ahridirectory.org, "IMP, -Conditioning,Heating,
click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on iliiiu Air
which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. and Refrigeration Institute
@2012 Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO.: 130022339782490133