Loading...
Permit HVAC 2166 S Fairway Villas Ln 2013 CITY OF ATLANTIC BEACH j 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00001998 Date 1/15/13 Property Address . . . . . . 2166 S FAIRWAY VILLAS LN Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu add 3 returns ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ SEELY TROPIC HEATING & AIR 2166 FAIRWAY VILLAS LN E 750 MAYPORT RD ATLANTIC BEACH FL 322334408 ATLANTIC BEACH FL 32233 (904) 241-1788 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 111 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 7/14/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 111 . 00 111 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 115 . 00 115 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE: WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH /�Q 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax(904) 247-5845 I JOB ADDRESS: (� 1 6 N) - Y� u -c PERMIT# PROJECT VALUE $ -j 35on" NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION ARI# 5'35-817 0 Air Conditioning: Unit Quantity / Tons Per Unit Z REQUIRED Heat: Unit Quantity i BTU's Per Unit Seer Rating /3 d Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Tanks(gallons) Wells OTHER: !&(Z ,-e1w c � ti .'S .sice..a..a-i —.¢dg/....� 3 0 o cl:--Al s tp �v�•n Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name Lf)N CA E Phone Number q G`�q Mechanical Company ra P,C. 1'4 4 h L Office Phone aq Fax Co. Address: -750 City (- Ci, State E Zip 3 a a 33 License Holder(Print): \,�f)T- IF .� • �(���� State Certification/Registration# c6Cd 5'a,43 J Notarized Signature of License Holder KAREN E.PANTFOEDER Sworn and subscn ed before me this 5 day of C-k n uQ►'�! 2013 NOTARY PUBLIC Signature of NotaryPublic G y STATE OF FLORIDA Comm#EE064448 Expires 3/4/2016 i CERTIFIED,. , 9CertificateProduct Ratings ce Number: 5358270 Date: 1/15/2013 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: GSZ130241B* Indoor Unit Model Number: ARUF24B14A* Manufacturer: GOODMAN MANUFACTURING CO., LP. Trade/Brand name: GOODMAN, JANITROL,AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR CONDITIONING AND HEATING, ENERGI AIR Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP. Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity(Btuh): 22800' EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Heating Capacity(Btuh)@ 47 F: 21600* Region IV HSPF Rating (Heating): 7.70 Heating Capacity(Btuh)@ 17 F: 13500 rerate of previously published data,unless accon__ a'NAS,which indicates an involuntary rerate- �s®rc. DIS*IMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION The information forthe modei cited on this certificate can be verified at Air-Conditioning,Heating, click on" "link and errter the AHRI Certified Reference Number and the date on Also No ai and Refrigeration Institute which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. 02012 Air-Conditioning,Heating, and Refrigeration Institute CERTIFICATE NO.: 130027346483342230 I Pro ect Summa Job: Seeley aw, t - � ry Date: 1/15/2013 Entire House By: soft•C«d&#swru AL Project • f For: Craig Seeley, Tropic Heating&Air Conditioning, Inc. 2166 Fairway Villas L.,Atlantic Beach, FL 32233 Phone: 904-241-1788 Fax: 904-241-2172 Email: Tropicac@msn.com Notes: Design • • Weather: Jacksonville/Craig, FL, US Winter Design Conditions Summer Design Conditions Outside db 35 'F Outside db 91 °F Inside db 70 °F Inside db 75 °F Design TD 35 'F Design TD 16 °F Daily range M Relative humidity 50 % Moisture difference 53 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 16459 Btuh Structure 12549 Btuh Ducts 3444 Btuh Ducts 3949 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 19904 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 16497 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1700 Btuh Ducts 842 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh ,Area(f:2) 1000 1000 Equipment latent load 2542 Btuh Volume(ft) 8000 8000 Air changes/hour 0.45 0.23 Equipment total load 19040 Btuh Equiv.AVF(cfm) 60 31 Req. total capacity at 0.70 SHR 2.0 ton Heating Equipment Summary Cooling Equipment Summary Make n/a Make Trade n/a Trade Model n/a Cond AHRI ref n/a Coil AHRI ref Efficiency n/a Efficiency 0 SEER Heating input 0 MBtuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 701 cfm Actual air flow 701 cfm Air flow factor 0.035 cfm/Btuh Air flow factor 0.042 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.87 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-Jan-15 06:21 40 WYigh't-soft Right-Su He®UnNersal 201212.1.05 Right J®Mobile Pagel C:\WINDOWS\TEMP\w tmp\faa54ddl-2b70-470e-a901-0358bc32debg.rup Calc=MJ8 FrontDoorfaces. E -- Job: Seeley Right J® Mobile Report Date: Seeley 11AEntire House By: ft"aoN%ftdm AL Project • • For: Craig Seeley, Tropic Heating&Air Conditioning, Inc. 2166 Fairway Villas L.,Atlantic Beach, FL 32233 Phone: 904-241-1788 Fax: 904-241-2172 Email:Tropicac@msn.com Design Conditions Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature (°F) 70 75 Elevation: 43 It Design TD(°F) 35 16 Latitude: 30°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 8.4 52.8 Dry bul b(°F) 35 91 Infiltration: Daily range(°F) - 17 ( M ) Method Simplified Wetbulb(°F) - 77 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 • Component Btuh/ftz Btuh %of load Walls 3.4 3278 16.5 Vd Glazing 19.7 2202 11.1 Lur Doors 13.5 425 2.1 g Ceilings 1.7 1695 8.5 Gm __ Irfiltrm Floors 6.6 6578 33.1 Infiltration 2.0 2280 11.5 Docs Ducts 3444 17.3 Piping 0 0 cilirgs Humidification 0 0 Rous Ventilation 0 0 Adjustments 0 Total 19904 100.0 Component Btuh/ft2 Btuh %of load Walls 2.6 2549 15.5 Intar�l C Glazing 45.7 5104 30.9 WA Is ans Doors 11.4 360 2.2 Ceilings 2.1 2097 12.7 Floors 0 0 0 Ducts Infiltration 0.5 549 3.3 - Ducts 3949 23.9 Ventilation 0 0 Ga ng Internal gains 1890 11.5 Blower 0 0 Infiltration Adjustments 0 Total 16497 100.0 Deas Ceilings Latent Cooling Load=2542 Btuh Overall U-value=0.131 Btuh/ftz--°F Data entries checked. illwrigl•'itSoft Right-Su Re®Universal 201212.1.05 Right J®Mobile 2013-Jan-1 e01 9 C:1WINDOWS\TEMPlwstmp\faa54dd1-2b70-470e-a901-0358bc32debg.rup Calc=MJ8 FrontDoorfaces. E Component Constructions Job: Seeley n "'i"i'i 5I, p Date: 1/15/2013 Entire House By: %Wh1 a Cub%srft- AL Project • ! For: Craig Seeley,Tropic Heating&Air Conditioning, Inc. 2166 Fairway Villas L.,Atlantic Beach, FL 32233 Phone: 904-241-1788 Fax: 904-241-2172 Email:Tropicac@msn.com Design Conditions Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature(°F) 70 75 Elevation: 43 ft Design TD(°F) 35 16 Latitude: 30°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(grab) 8.4 52.8 Dry bulb(°F) 35 91 Infiltration: Daily range(°F) - 17 ( M ) Method Simplified Wetbulb(°F) - 77 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 Construction descriptions or Area U-value Insul R Htg HTM Loss Clg HTM Gain 1F Bhh/R--'F 1F-"FIBIh BMW Btuh BthM Btuh Walls 1213-0sw:Frm wall,vnl ext,r-11 cav ins,1/2"gypsum board int n 184 0.097 11.0 3.36 619 2.61 481 fnsh,2"x4"wood frm a 288 0.097 11.0 3.36 968 2.61 752 s 216 0.097 11.0 3.36 724 2.61 563 W 288 0.097 11.0 3.36 968 2.61 752 all 977 0.097 11.0 3.36 3278 2.61 2549 Partitions (none) Windows 1 D-c2ow:2 glazing,Cir outr,air gas,wd frm mat,dr innr,l/4"gap, n 24 0.570 0 19.7 477 20.9 505 1/8"thk a 32 0.570 0 19.7 625 63.0 1995 S 24 0.570 0 19.7 477 25.2 608 W 32 0.570 0 19.7 625 63.0 1995 all 112 0.570 0 19.7 2202 45.7 5104 Doors 11 D0:Door,wd sc type n 32 0.390 0 13.5 425 11.4 360 Ceilings 16C-19al:Attic ceiling,asphalt shingles roof mat,r-19 ceil ins,1/2" 1000 0.049 19.0 1.70 1695 2.10 2097 gypsum board int fish Floors 22A-cph:Bg floor,heavy damp soil,on grade depth,carpet fir fish 140 1.358 0 47.0 6578 0 0 Wrl htSOfC 2013Jan-1506:21:40 9 Right-Suite* 12.1.05 Right,1®M°bile Page 1 C:1w9NDOWMTEMP*,sMVVaa54dd1-2b70-470e-a901-035Bbc32deb9.rup Calc=MJB Front Door faces: E IQ Right-J® Worksheet Job: Seeley Entire House Date: 1/15/2013 By: AL 1 Room name Entire House First Floor 2 Exposed wall 140.0 ft 140.0 ft 3 Room height 8.0 ft d 8.0 ft heaU000l 4 Room dimensions 1.0 x 1000.0 It 5 Room area 1000.0 ft' 1000.0 ft' T Construction U-value Or HTM Area ft` Load Area If Load Y ( ) ( ) number (Btuh/ftp-°F) I (Btuh/ftj I or perimeter (ft) (Btu h) or perimeter (ft) (Btuh) Heat Cool Gross NIPIS Heat Cool Gross NIP/S Heat Cool 61213-0sw 0.097 n 3.36 2.61 240 184 619 481 240 184 619 481 1D-c2ow 0.570 n 19.72 2091. 24 0 477 505 24 0 477 505 11DO 0.390 n 13.49 11.43 32 32 425 360 32 32 425 360 Vy 12B-0sw 0.097 a 3.36 2.61 320 288 968 752 320 288 968 752 11 L—C 1D-clow 0.570 a 19.72 63.01 32 0 625 1995 32 0 625 1995 V►I 12B-Osw 0.097 s 3.36 2.61 240 216 724 563 240 216 724 563 I—G 1 D-c2ow 0.570 s 1972. 25.16 24 0 477 608 24 0 477 608 Vj/ 12B-0sw 0.097 w 3.36 2.61 320 288 968 752 320 288 968 752 G 1D-clow 0.570 w 1972 63.01 32 0 625 1995 32 0 625 1995 C 16C-19al 0.049 - 1.70 2.10 1000 1000 1695 2097 1000 1000 1695 2097 F 22A-cph 1.358 - 46.99 0.00 1000 140 6578 0 1000 140 6578 0 61 c)AED excursion 0 0 Envelope loss/gain 1 14179 10110 1 1 14179 10110 12 a) Infiltration 2280 549 2280 549 b) Room ventilation 0 0 0 0 13 Internal gains. Occupants 230 3 690 3 690 Appliances/other 1200 1200 Subtotal(lines 6 to 13) 16459 12549 16459 12549 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 16459 12549 16459 12549 15 Dud loads 21% 31% 3444 3949 21% 31% 3444 3949 Aotaequomdlom) I I I 199041 16701 I I I 19901 I 16701 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrigEiTsrrFY Right-Suited!)Universal 201212.1.05 Right JO Mobile 2013-Jan-1506:Page01 C.\WINDOWS\TEMP\wstmp\faa54dd1-2b70-470e-a901-0358bc32deb9.rup CaIc=MJ8 FrontDoorfaces: E 9 AED Assessment Job: Seeley Date: 1/15/2013 Entire House By: Ekr,:q A:asLty 5irit•na AL Project Information For: Craig Seeley, Tropic Heating&Air Conditioning, Inc. 2166 Fairway Villas L.,Atlantic Beach, FL 32233 Phone: 904-241-1788 Fax: 904-241-2172 Email:Tropicac@msn.com Design Conditions Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature(°F) 70 75 Elevation: 43 ft Design TD(°F) 35 16 Latitude: 30°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(grAb) 8.4 52.8 Dry bul b(°F) 35 91 Infiltration: Daily range(°F) - 17 ( M ) Wetbulb(°F) - 77 Wind speed(mph) 15.0 7.5 Test for Adequate ExposureDiversity Hourly Glazing Load 7,00 6,00 5,00 4,00C 3,00G 2,00G 1 '00Q- 8 9 10 11 12 13 14 15 16 17 18 19 20 Hour of Day Houty Average PEDlirrit Maximum hourly glazing load exceeds average by 19.6%. House has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh .^� wrightsoft Right-Suite®Universa1201212.1.05 Right J®Mobile 2013-Jan-1506:21:40 I Page 1 iCC�'IC3WINDOWSITEMRwstmplfaa54dd1-2b70-470e-a901-0358bc32debgrup Calc=MJ8 FrontDoorfaces. E