Loading...
Permit ResAlt 5507 Rigel Ct 2013 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD Jg As ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application - pp cation Number 13 00001993. Date 1/16/13 Property Address . . . . 5507 RIGEL CT Tenant nbr, name FLEET LANDING Application type description RESIDENTIAL ALTERATION Property Zoning . . . . . TO BE UPDATED Application valuation . . 4300 ----- ----------------------------------------------- Application desc SHWR conversion sunROOM STUCCO W/SHEETROCK ---------------------------- ----------------------------------------------- Owner Contractor ----------------------- ------------------------ NAVAL CONTINUING CARE NAVAL CONTINUING CARE RETIREMENT FOUNDATION, INC ONE FLEET LANDING BLVD. 1 FLEET LANDING BLVD ATLANTIC BEACH FL 32233 ATLANTIC BEACH FL1322334599 (904) 246-9900 --- Structure Information Opo 000 SHOWER CONVERSION SUNROOM REPAIRS Occupancy Type . . . RESIDENTIAL ---------------------------------------------------------------------------- Permit . . . . . . RESIDENTIAL ALT/OTHER Additional desc Permit Fee . . . . 75 . 00 Plan Check Fee 37 . 50 Issue Date . . . . Valuation . . . . 4300 Expiration Date , 7/15/13 ----------------------------I------------------------------------------------ Special Notes and Comments 2010 FLORIDA BUILDING CODE, 2008 NATIONAI' ELECTRIC CODE *REPORT ANY UNFORSEEN STRUCTURAL DAMAGE TO THE BUILDING DEPARTMENT IMMEDIATELY. ----------------------------'------------------------------------------------ Other Fees . . . . . . . . STATE DCA SURCHARGE 2 . 00 STATE DBPR SURCHARGE 2 . 00 ---------------------------- ------------------------------------------------ Fee summary Charged Paid Credited Due ----------------- ---- ----- ---------- ---------- ---------- Permit Fee Total 75 . 00 75 . 00 . 00 . 00 Plan Check Total 137 . 50 37 . 50 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total X16 . 50 116 . 50 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE NYITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. BUILDING PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Road, Atlantic Beach, FL 32233 Office (004) 247-5826 Fax (904) 247-5845 Job Address: 550`1 (:Z:�C-,1'Z-` �T Permit Number: �g _ Legal Description P rcel# Floor a o q.Ft. Sq.Ft Valuation of Work$, � SOD _Proposed Work heated/cooled non-heated/cooled Class of Work(circle one): New Addition Alteration Repair Move Demolition pool/spa window/door Use of existing/proposed structures) (circle one):. Commercial Rcsidcntia If an existing structure,is a fire sprinkler system installed? (Circle one): es o N/A Florida Product Approval# For multiple products use product approval o('m Describe in detail the type of work to be perfor ed: Aj�r_ lDvJ�_t + 4 eco k Property Owner Information: Name: NCCRF i Address: One Fleet Landing Blvd. City Atlantic Beach State FL Zip 32233 Phone 904-246-9900 x E-Mail or Fax# (Optional) Contractor Information: r ILL Company Name: NCCRF Qualifying Agent: Joshua D. Address: One Fleet Landing Blvd. City Jacksonville State FL Zip 32233 Office Phone 904-246-9900 Job Site/Contact - - State Certification/Registration# CGC1521135 Architect Name&Phone# Engineer's Name &Phone# Cri T OF ATtV4,nC 17 DI�'1 EAC Fee Simple Title Holder Name and Address Bonding Company Name and Address Mortgage Lender Name and Address 77 Application is hereby made to obtain a permit to do the wor ail" ms has commenced prior to the issuance of a permit and that all work will be performed to meetthe standards of all laws regulating 0onstruction in this jurisdiction. 77us permit becomes null and void tf work is not commenced within six(6)months, or if c onstruction or work is suspended or abandoned for a period of six16)months at any time after work is commenced I understand that separate permits must be secured for Electrical Work Phonbing, Signs, We&, Pools, t'urnaces,Boilers,Healers, Tankr and Air Conditioners,etr- WARNING TO OWNER: OUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESUL IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU I TEND TO OBTAIN FINANCING CONSULT WITH YOUR LENDER OR AN ATTO EY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. I hereby certify that I have read and examined this a)plication and know the scone to be true and correct. All provisions of laws and ordinances governing this type o work will be complied with whether specs ted herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of arty other federal,state,or l al law regulating construction or the performance of construction. Signature of Owner L Signature of Contractor_ "� Print Name Joshua Hatfield Print Name Joshua Hatfield SwoVDay and subscritua�befor me Swo o and subscrib before e thisof200 this Day of c 20�3 ELIZABETH TESKE ELIZA NOta ub1C =r; Notary Public-S ate of Florida • fab ' ry Public-Stat Florida . My Comm.Expires Apr 5,2013 " • 'e MY!Comm.Expires Apr 5,201 «�`� ised 01.26.10 'sr " Commission#►DD 867829 E a; Commission#DD 867829 ct �� q,0;;1�,• Bonded Through Nati nal Notary Assn., Bonded Through National Notary Assn. NOTICE OF COMMENCEMENT D O O E MVLIANCE °^ I O Permit No. / 3 - /991 -7 0 Tax Folio No. i J THE UNDERSIGNED hereby gives notice that improvements w1 m 713.13 of the Florida Statutes,the following informat on is provided in this NOTICE OF CONEWENCEMENT. ® s 1.Description of property(legal description): a)Street(job)Address: 550 -,E L ATIC FfEC' L 2'Z3 3 2.G eral description of improvements: 4Vj E9 PNA46144; (MaJ Tb C. Q JA SMAJ r►'1 ifPZAe l� 0 rrg S O L 3.Owner Information a)Name and address: hi C � b)Name and address of fee simple titlehold (if other than owner) c)Interest in property 4.Contractor Information Q a)Name and address: AICC F F b)Telephone No.: q0 - 24(o op Fr 5.Surety Information Doc#2013011810,OR 6K 16216 Page 671, ^ ad address: Number Pages: 1 v )Name anRecorded 01 1 1 4r2013 at 02:41 PM. b)Amount of Bond: Ronnie Fussell CLERK CIRCUIT COURT DUVAL c)Telephone No.: F, COUNTY 61ender RECORDING$10.00 a)Name and address: Phone NO. 7.Identity of person within the State of Florida desi ated by owner upon whom noticesor other documents may be served: a)Name and address: b)Telephone No.: Fax No.(Opt.) 8.In addition to himself,owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes: a)Name and address: b)Telephone No.: Fax No. (Opt.) 9.Expiration date of Notice of Commencement(thee piration date is one year from the date of recording unless a different date is specified): WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713,PART I,SECTION 71113, FLORIDA STATUTES,AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE I ECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN F NANCING,CONSULT YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING VOI R NOTICE OF COMMENCEMENT. STATE OF FLORIDA COUNTY OF PINELLAS 10. Signature of Owner or Owner'sZrr-1 zed Officer/Director/Partner/Manager �S014A �c, b Print Name The foregoing instrument was acknowledged before rite this day of 20 ,by as (type of authority,e.g.officer,trustee, , attorney in fact)for (name of party on behalf of whom instrument was executed). , ,� _ 1 Personally Known OR Produced Identification Notary Signature _`' Type of Identification Produced Name(print)Z,- .0 c OR Verificati a a es.Under penalties of perjury,I declare that I have read the foregoing and that the facts te�i• ,41 true to � 1 e and belief. =o` n Notary�ubTic- �� g s ;• My Comm.Expires Apr 5,2013 / Foxn+smoc �. off, Commission#OD 867829 -J CCjL�c %.cFF: �` Bonded Through National Notary Assn. Signature of Natural Person Sign g(in line k 10.)Above "'Woo City of Atlantic Beach APPLICATION NUMBER Building Department SW Seminde Road (i o be assigned by the Bu7dfng Departrnent) Atlantic Beach.Florida 32233+5445 Phone(904)247-M - Fax tW4)247-5845 o,• E-mail: builclfng-dep4�coab.us Date routed City web-site: tt WWwww.coao.us APPLICATION Ri�EVIEW AND TRACKING FORM ,Y Property Address: ,� C De rtrnent rneview uired Yes No , A e L7uilding Applicant: V / Planning&Zoning „ _� �^, Tree Administrator Project: HiQ ( _ Public Works Public Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Of Permit Verified Date Florida Dept.of Envirornrental Prot on Florida Dept of Transportation St:Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division ofAlwhdic Beverages and Toba= Other: APPLICATION STATUS Reviewing Department First Review: roved. (Cirde one. ❑Denied. Comments: BUILDING PLANNING&ZONING Reviewed by:_ ti Date: l—%S TREEADMIN. Second Review. QA�pnaved as revised. ❑Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed Date. FIRE SERVICES Third Review: EIA prrn+ed as revised. ElDenied. Comments: Reviewed by: Date: RevisA 07127110 C" 1 CITY OF ATLANTIC BEACH j 800 SEMINOLE ROAD ;? = ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00002438 Date 4/05/13 Property Address . . . . . . 5507 RIGEL CT Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 CU 1 AHU ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ NAVAL CONTINUING CARE AIR PRO MECHANICAL OF N FL LLC RETIREMENT FOUNDATION, INC 1008 COUNTY RD 217 1 FLEET LANDING BLVD JACKSONVILLE FL 32234 ATLANTIC BEACH FL 322334599 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 107 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 10/02/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 107 . 00 107 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 111 . 00 111 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax (904) 247-5845 .TOB ADDRESS: 5:U'_A GC-L PERMIT# PROJECT VAL UE $ SO ARI#_ 3(oos 2-(P� REQUIRED NEW AIR CONDITIONING & HEATING S MINSTALLATION / Air Conditioning: Unit uantit Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM TEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit l Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name rl&-,7- G- Phone Number Mechanical Company f'-ti /�!?v {�'IE;�-� r%c�/ C C Office Phone,2k9-9f y'�/ Fax Co. Address: 100K C,/?- 2!-7 City State FL Zip 3�23-�l License Holder(Print): ^-) t cKmY4L/ State Certification/Registration# cthe/2y9��� Notarized Signature of License Holder y day f 20 13 "T" 41W WAY r, AMI3Q� D 9 GxPic _ aQi�NT o ry Public Bonded Thn:Notary Public Underwriters Residential System Sizing Calculation Summary FLEETWOOD LANDING Project Title: Code Only 5507 RIGEL COURT SANTA DOMINGO WITH SUN Professional Version ATLANTIC BCH, FL Climate: North 4/5/2013 Location for weather data: Jacksonville - Defaults: Latitude(30) Altitude(26 ft.) Temp Range(M) Humidity data: Interior RH 50% Outdoor wet bulb 77F Humidity difference 53 r. Winter design temperature 32 F Summer design temperature 93 F Winter setpoint 70 F Summer setpoint 75 F Winter temperature difference 38 F Summer temperature difference 18 F Total heating load calculation 47877 Btuh Total cooling load calculation 39540 Btuh Submitted heating capacity % of calc Btuh Submitted cooling capacity % of calc Btuh Total (Electric Heat Pump) 94.0 45000 Sensible (SHR = 0.81) 116.7 36450 Heat Pump + Auxiliary(O.OkW) 94.0 45000 Latent 103.1 8550 Total Electric Heat Pum 113.8 45000 WINTER CALCULATIONS Winter Heating Load for 2347 sqft) Verdiletion(2%) Load component Load Ducts(l1%) Window total 438 sqft 14473 Btuh Wndows(30%) Wall total 2020 sqft 7282 Btuh Door total 39 sqft 519 Btuh ntilc,s%) _ Ceiling total 2427 sqft 2989 Btuh Floor total 202 sqft 9058 Btuh Infiltration 170 cfm 7107 Btuh Doors(,%) Duct loss 5405 Btuh Ceilings(6%) Subtotal 46833 Btuh 9%) Ventilation 25 cfm Floors(1044 Btuh We11s(15%) TOTAL HEAT LOSS 47877 Btuh SUMMER CALCULATIONS Summer Cooling Load for 2347 sqft) Load component Load Window total 438 sqft 11710 Btuh Wall total 2020 sqft 5021 Btuh Door total 39 sqft 396 Btuh Ceiling total 2427 sqft 2596 Btuh �e 5 ons Ird.Gan(10%) Floor total 0 Btuh Wnd,K3,) Infiltration 121 cfm 2402 Btuh Internal gain 3840 Btuh Duct gain 4786 Btuh Sens. Ventilation 25 cfm 495 Btuh ouascls%) Total sensible gain 31244 Btuh Latent gain(ducts) 1423 Btuh CNIIn9s(7%) Latent gain(infiltration) 4372 Btuh Latent gain(ventilation) 900 Btuh In}il.(17%) Latent gain(internal/occupants/other) 1600 Btuh °o°r'"%) Total latent gain 8295 Btuh TOTAL HEAT GAIN 39540 Btuh EnergyGauge®Syste lZi g a. Version 8 PREPARED BY: = =ti For Florida residences only DATE: EnergyGauge® FLRCPB v4.5.2 System Sizing Calculations - Summer Residential Load - Whole House Component Details FLEETWOOD LANDING Project Title: Code Only 5507 RIGEL COURT SANTA DOMINGO WITH SUN Professional Version ATLANTIC BCH, FL Climate: North Reference City: Jacksonville (Defaults) Summer Temperature Difference: 18.0 F 4/5/2013 --- Component Loads for Whole House Type* Overhang Window Area(sqft) HTM Load Window Pn/SHGC/U/InSh/ExSh/IS Omt Len H t Gross Shaded Unshaded Shaded Unshaded 1 2,Clear,0.87, None,N,H N 1.4ft 1ft. 60.0 0.0 60.0 27 27 1605 Btuh 2 2,Clear,0.87, None,N,H W 1.4ft 1ft. 75.0 75.0 0.0 27 72 2006 Btuh 3 2,Clear,0.87, None,N,H W 1.4ft 1ft. 17.8 17.8 0.0 27 72 476 Btuh 4 2,Clear,0.87, None,N,H S 1.4ft 1ft. 180.0 180.0 0.0 27 32 4815 Btuh 5 2,Clear,0.87, None,N,H E 1.4ft 1ft. 105.0 105.0 0.0 27 72 2809 Btuh Window Total 438 (sqft) 11710 Btuh Walls Type R-Value/U-Value Area(sqft) HTM Load 1 Frame-Wood-Ext 11.0/0.09 1820.0 2.6 4679 Btuh 2 Frame-Wood-Adj 11.0/0.09 200.0 1.7 342 Btuh Wall Total 2020(sqft) 5021 Btuh Doors Type Area (sqft) HTM Load 1 Insulated-Exterior 21.0 10.1 213 Btuh 2 Insulated-Adjacent 18.0 10.1 183 Btuh Door Total 39 (sqft) 396 Btuh Ceilings Type/Color/Surface R-Value Area(sqft) HTM Load 1 Vented Attic/DarkTile 30.0 2347.0 1.1 2467 Btuh 2 Vented Attic/DarkTile 19.0 80.0 1.6 129 Btuh Ceiling Total 2427 (sqft) 2596 Btuh Floors Type R-Value Size HTM Load 1 Slab On Grade 0.0 202(ft(p)) 0.0 0 Btuh Floor Total 202.0 (sqft) 0 Btuh Envelope Subtotal: 19722 Btuh Infiltration Type ACH Volume(cuft)wall area(sqft) CFM= Load SensibleNatural 0.16 25817 2020 170.2 2402 Btuh Internal Occupants Btuh/occupant Appliance Load gain 8 X 230 + 2000 3840 Btuh Sensible Envelope Load: 25964 Btuh Duct load (DGM of 0.184) 4786 Btuh Sensible Load All Zones 30750 Btuh EnergyGauge® FLRCPB v4.5.2 Page 1 Manual J Summer Calculations Residential Load - Component Details (continued) FLEETWOOD LANDING Project Title: Code Only 5507 RIGEL COURT SANTA DOMINGO WITH SUN Professional Version ATLANTIC BCH, FL Climate: North 4/5/2013 WHOLE HOUSE TOTALS Sensible Envelope Load All Zones 25964 Btuh Sensible Duct Load 4786 Btuh Total Sensible Zone Loads 30750 Btuh Sensible ventilation 495 Btuh Blower 0 Btuh Whole House Total sensible gain 31244 Btuh Totals for Cooling Latent infiltration gain (for 53 gr. humidity difference) 4372 Btuh Latent ventilation gain 900 Btuh Latent duct gain 1423 Btuh Latent occupant gain (8 people @ 200 Btuh per person) 1600 Btuh Latent other gain 0 Btuh Latent total gain 8295 Btuh TOTAL GAIN 39540 Btuh EQUIPMENT 1. Central Unit # 45000 Btuh `Key: Window types(Pn-Number of panes of glass) (SHGC-Shading coefficient of glass as SHGC numerical value or as clear or tint) (U-Window U-Factor or'DEF'for default) "'1� (InSh-Interior shading device: none(N), Blinds(B), Draperies(D)or Roller Shades(R)) (ExSh-Exterior shading device: none(N)or numerical value) (BS-Insect screen: none(N), Full(F)or Half(H)) � (Ornt-compass orientation) Version 8 For Florida residences only EnergyGauge(D FLRCPB v4.5.2 Page 2 LAID Ann ROILS CERTIFIEDTM Certificate of Product Ratings AHRI Certified Reference Number: 3605264 Date: 4/5/2013 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 13PJL48 Indoor Unit Model Number: RHSL-HM4821+RCSL-H*4821 Manufacturer: RHEEM MANUFACTURING COMPANY Trade/Brand name: RHEEM 13PJL SERIES Manufacturer responsible for the rating of this system combination is RHEEM MANUFACTURING COMPANY Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (Btuh): 46500 EER Rating (Cooling): 10.50 SEER Rating (Cooling): 13.00 Heating Capacity(Btuh) @ 47 F: 46000 Region IV HSPF Rating (Heating): 8.50 Heating Capacity(Btuh) @ 17 F: 30600 Ratings followed by an asterisk(')indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized atteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at wvvw.ah rid irectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION The information forthe model cited on this certificate can be verified at www.ahridirectory.org, Air-Conditioning,Heating, click on'Verify Certificate"link and enter the AHRI Certified Reference Number and the date on �. ■�,' and Refrigeration Institute which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. @2013 Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 130096659342287727