Loading...
Permit HVAC 1735 Beach Ave 2013 x.= '1 CITY OF ATLANTIC BEACH j 800 SEMINOLE ROAD !) B w ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00002024 Date 1/18/13 Property Address . . . . . . 1735 BEACH AVE Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ LANE EDWARD W III AIR TO AIR 1735 BEACH AVE 11578 DAVIS CREEK CT ATLANTIC BEACH FL 32233 JACKSONVILLE FL 32256 (904) 262-4279 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 87 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 7/17/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 87 . 00 87 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 91 . 00 91 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax(904) 247-5845 JOB ADDRESS: /'1.�_� 13-6,1&A E,-;, Ue 17 C)e PERMIT# PROJECT VALUE $ J ARI# 36 q q 3 REQUIRED NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity 1 Tons Per Unit I Heat: Unit Quantity I BTU's Per Unit 12.nvy Seer Ratings 3 U Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name Lar�e-- Phone N berg&4 l-- -3 ci o Lf4 y Mechanical Company; , r -V-\ Office Phone�lr�-L('9�]c(Fax; -a 17 Co. Address: i 15 �av, 5 J e u r �- �_) State LZips License Holder(Print): - 0-- '!� ,, C� to Certificatio egistration# C-AG-Iql 110("C' Notarized Signature of License Holder RM S rnand subscr bed before me this 1 c�ay of �� 20 )3 STONER SION#DD976309 — rr1May 22.2013 Signature of Notary Publicry Discount Assoc.Co. Job: 876 + - wrightsoft® Project Summary Date: 01/18/13 Entire House By: JH Air to Air Inc. 11578 Davis Creek Ct,Jacksonville,FL 32256 Phone:904 262-4279 Fax:904 262-4279 Email:airtoair4@bellsouth.net Web:airtoairinc.com Project Information For: LANE RESIDENCE 1735 BEACH AVE,ATLANTIC BEACH, FL 32233 Notes: - • • • Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 OF Outside db 92 OF Inside db 70 OF Inside db 75 OF Design TD 31 OF Design TD 17 OF Daily range L Relative humidity 50 % Moisture difference 58 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 12556 Btuh Structure 11224 Btuh Ducts 641 Btuh Ducts 698 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 13198 Btuh Use manufacturer's data n Rate/swing multiplier 0.97 Infiltration Equipment sensible load 11565 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 842 Btuh Ducts 165 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft') 262 262 Equipment latent load 1007 Btuh Volume(ft') 2096 2096 Air changes/hour 0.61 0.32 Equipment total load 12572 Btuh Equiv.AVF (cfm) 21 11 Req. total capacity at 0.70 SHR 1.4 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade BASE 13 PURON HP Trade BASE 13 PURON HP Model 25HBC318(A,W)""30 Cond 25HBC318(A,W)-'30 AHRI ref no.3699493 Coil FB4CNF018 AHRI ref no.3699493 Efficiency 8 HSPF Efficiency 11.0 EER, 13 SEER Heating input Sensible cooling 12180 Btuh Heating output 17400 Btuh @ 47°F Latent cooling 5220 Btuh Temperature rise 27 OF Total cooling 17400 Btuh Actual air flow 580 cfm Actual air flow 580 cfm Air flow factor 0.044 cfm/Btuh Air flow factor 0.049 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.92 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-Jan-18 11:51:59 + wrightsoft' Right-Suite®Universal 2012 12.0.07 RSU10246 page 1 .4c"`C i. P:\DOUG\Manual J-Chg Out(Masters)\876(2 Ton 15).rup Calc=MJ8 Front Door faces: E Buildin Analysis Job: 876 +�- wrightsoft`° gDate: 01/18/13 Entire House By: JH Air to Air Inc. 11578 Davis Creek Ct,Jacksonville,FL 32256 Phone:904 262-4279 Fax:904 262-4279 Email:airtoair4@bellsouth.net Web:airtoairinc.com • ect Information For: LANE RESIDENCE 1735 BEACH AVE,ATLANTIC BEACH, FL 32233 Design C• • • Location: Indoor: Heating Cooling Jacksonville Mayypport Naval, FL, US Indoor temperature(°F) 70 75 Elevation: 16 ft Design TD (°F) 31 17 Latitude: 30°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 4.6 58.2 Dry bulb(°F) 39 92 Infiltration: Dally range°F) - 15 ( L ) Method Simplified Wet bulb(° ) - 78 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 • Component Btuh/ft2 Btuh % of load Walls 2.7 2953 22.4 Glazing 10.2 1074 8.1 Doors 18.6 446 3.4 Ceilings 1.0 260 2.0 Floors 27.1 7097 53.8 Infiltration 0.6 726 5.5 Ducts 641 4.9 Piping 0 0 D Humidification 0 0 � . Ventilation 0 0 Adjustments 0 Total 13198 100.0 Component Btuh/ft2 Btuh %of load Walls 2.4 2566 21.5 Glazing 15.1 1589 13.3 Wale Doors 18.5 444 3.7 Ceilings 1.7 456 3.8 Floors 0 0 0 Infiltration 0.2 209 1.8 Internal Gains Ducts 698 5.9 Ventilation 0 0 Glazing Internal gains 5960 50.0 Blower 0 0 Adjustments 0 °o Total 11922 100.0 Ceilings Ofher Ducts Latent Cooling Load= 1007 Btuh Overall U-value=0.220 Btuh/ft2-°F WARNING:window to floor area ratio=40.1%-more than 25%. 2013-Jan-18 11:51:59 A, +I+ wrightsoft' Right-Suite®Universal 2012 12.0.07 RSU10246 Page 1 ACM PAMUMManual J-Chg out(Masters)\876(2 Ton 15).rup Calc=MJ8 Front Door faces: E AED Assessment Job: 876 wrightsoft® Date: 01118/13 Entire House By: JH Air to Air Inc. 11578 Davis Creek Ct,Jacksonville,FL 32256 Phone:904 262-4279 Fax:904 262-4279 Email:airtoair4@bellsouth.net Web:airtoairinc.com Project Information For: LANE RESIDENCE 1735 BEACH AVE,ATLANTIC BEACH, FL 32233 Design Conditions Location: Indoor: Heating Cooling Jacksonville Mayport Naval, FL, US Indoor temperature(°F) 70 75 Elevation: 16 ft Design TD (°F) 31 17 Latitude: WON Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 4.6 58.2 Dry bulb(°F) 39 92 Infiltration: Daily range(°F) - 15 ( L ) Wet bulb(°F) - 78 Wind speed (mph) 15.0 7.5 Test for Adequate • • Hourly Glazing Load 2,000-- 1,800-- 1,600--/o ,0001,8001,600 1,400- 1,200-- CD ,4001,200CD 1,000-- 800-- 600-- 400-- 200-- 0 ,0080600400200 8 9 10 11 12 13 14 15 16 17 18 19 20 Hour of Day /Hourly /Average /AED limit Maximum hourly glazing load exceeds average by 35.6%. House does not have adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 75 Btuh (PFG - 1.3*AFG) 2013-Jan-18 11:51:59 wrightsoft® Right-Suite®Universal 2012 12.0.07 RSU10246 Page 1 ACCK P:\DOUG\Manual J-Chg Out(Masters)\876(2 Ton 15).rup Calc=MJ8 Front Door faces: E + wrightsoft, Right-J® Worksheet Job: 876 Entire House Date: 01/18/13 By: JH Air to Air Inc. 11578 Davis Creek Ct,Jacksonville,FL 32256 Phone:904 262-4279 Fax:904 262-4279 Email:airtoair4@bellsouth.net Web:airtoairinc.com 1 Room name Entire House WHOLE HOUSE 2 Exposed wall 440.0 ft 440.0 ft 3 Room height 8.0 ft 8.0 ft heat/cool 4 Room dimensions 262.0 x 1.0 ft 5 Room area 262.0 ft' 262.0 ft2 Ty Construction U-value Or HTM Area (ftp Load Area (ftp) Load number (Btuh/ft'-°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 12C-Osw 0.091 w 2.82 2.35 1136 1007 2841 2369 1136 1007 2841 2369 3A-2om 0.330 ne 10.23 13.28 30 0 307 399 30 0 307 399 3A-2om 0.330 se 10.23 11.28 45 23 460 507 45 12 460 507 3A-2om 0.330 sw 0.00 0.00 0 15 0 0 0 8 0 0 11 3A-2om 0.330 w 10.23 20.26 30 2 307 608 30 1 307 608 3A-2om 0.330 nw 0.00 0.00 0 0 0 0 0 0 0 0 11JO 0.600 w 18.60 18.51 24 24 446 444 24 24 446 444 W 166-19ad 0.049 w 1.52 2.66 74 74 112 197 74 74 112 197 T 12C-Osw 0.091 - 0.00 0.00 0 0 0 0 0 0 0 0 T-D 11 DO 0.390 n 0.00 0.00 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 0.99 1.74 262 262 260 456 262 262 260 456 F 20P-13c 0.068 0.00 0.00 0 0 0 0 0 0 0 0 F 22A-tpm 1.180 36.58 0.00 262 194 7097 0 262 194 7097 0 6 c)AED excursion 75 75 Envelope loss/gain 11830 5055 11830 5055 12 a) Infiltration 726 209 726 209 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 2 460 Appliances/other 5500 5500 Subtotal(lines 6 to 13) 12556 11224 12556 11224 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 12556 11224 12556 11224 15 Duct loads 5% 6%1 641 698 5% 6% 641 698 Total room load 13198 11922 13198 11922 Air required(cfm) 580 580 580 580 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-Jan-18 11:51:59 '1+1- wrightSOftm Right-Suite®Universal 2012 12.0.07 RSU10246 Page 1 AC�t. P:\DOUG\Manual J-Chg Out(Masters)\876(2 Ton 15).rup Calc=MJ8 Front Door faces: E Kilo wal CERTIFIEDT. s Certificate of Product Ratings AHRI Certified Reference Number: 3699493 Date: 1/18/2013 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 25HBC318(A,W)**30 Indoor Unit Model Number: FB4CNF018 Manufacturer: CARRIER AIR CONDITIONING Trade/Brand name: BASE 13 PURON HP Manufacturer responsible for the rating of this system combination is CARRIER AIR CONDITIONING Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity(Btuh): 17400 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Heating Capacity(Btuh)@ 47 F: 17400 Region IV HSPF Rating (Heating): 8.00 Heating Capacity(Btuh) @ 17 F: 10500 Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the products)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION ��, The information for the model cited on this certificate can be verified at www.ahridirectory.org, Air-Conditioning,Heating, click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on � On I►/ and Refrigeration Institute which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. ©2012 Air-Conditioning,Heating,and Refrigeration Institute CERTIFICATE NO.: 130030051421661878