Permit HVAC 1728 W Park Ter 2013 St CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00002036 Date 1/23/13 Property Address . . . . . . 1728 W PARK TER Application type description RESIDENTIAL ALTERATION Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 35000 ---------------------------------------------------------------------------- Application desc kitchen /bath remodel no structure change ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ HAMIL, ROBERT R M HAMIL ENTERPRISES, INC 160 11TH ST DBA BOB HAMIL POOLS & SPAS ATLANTIC BEACH FL 32233 160 11TH ST ATLANTIC BEACH FL 32233 (904) 631-6268 --- Structure Information 000 000 KITCHEN/BATH REMODEL NO STRUCTURE Occupancy Type . . . . . . RESIDENTIAL ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc REPLACE 1 CU 1 AHU & DUCT Sub Contractor AIR EXCELLANCE INSTALLATION Permit Fee . . . . 127 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 7/22/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 127 . 00 127 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 131 . 00 131 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247-5826 Fax (904) 247-5845 JOB ADDRESS: PAR K �t2AN C-E 212 (J PERMIT# 13-,�X 36 36&LI -7, PROJECT VAL UE $ 0/,joc cl C ARI# REQUIRED NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM Ain n REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty_ Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells 0 T H E R: L/ 7&'-t Al Ac e ii e,0 ckckppar r- Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name �SAufJQF_P,,5 :Rre-mv PhoneNumber (03J -60,20, Mechanical Company ALM Egeellew4g_ T12 5,�&/&/`A eyjSJc_ Office PhoneCU3-ft 7 Fax Co. Address: 3913 Z?4�D city J�;�- Stater—C Zip3,P?,5-7 License Holder(Print): 1Q5&LA-LA State Certification/Registration Q'Ic-tj I 5_�a Notarized Signature of License Holder K A Sworn and subscribed before me this Z� dayof_-4nV^fy 20.1 0A STEPHEN T.PUTNAM Notary Public,State of Florida Signature of Notary Puhac���... Commission#DD998148 MY comm.expires JUlY 20,2014 Job: AEIIA/Saunders20113 + wrightsoft Right J@ Mobile Report Date: 1122/2013 Entire House By: Ronald Lee Air Excellence Installation & Service, Inc 3813 Bald Eagle Lane,Jacksonville.FL 32257 Phone.904-923-4967 Fax�904-268-0903 Email airexr-eliencejax@comcast.net Web httloWwwwairexcellencefla com Lic Project Information For: Jeremy Saunders 1728 Park Terrace Dr W,Atlantic Beach, FL 32233 Phone: 904-631-6268 Bob Design Conditions Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature ('F) 70 74 Elevation: 43 ft Design TD(oF) 35 17 Latitude: 30'N Relative humidity 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 8.4 55.0 Dry bul b('F) 35 91 Infiltration: Daily range ff) - 17 M Method Simplified Wet bulb(o F) - 77 Construction quality Average Wind speed (mph) 15.0 7-5 Fireplaces 0 Component Btu hfiF Btuh %of load Walls 3.4 5093 16.0 VIA Glazing 193 2810 8.8 Doors 13.5 433 1.4 Dils 9 Ceilings 1.7 3208 10-1 Floors 2.7 5106 16.0 Infiltration 2.4 4098 12.8 Ducts 11161 35.0 Cefirgs ah Piping 0 0 Humidification 0 0 Roas Ventilation 0 0 Adjustments 0 Total 31909, 100.0 Component Btu h/ft2 Btuh %of load— Walls 1.6 2429 7.3 V\/31 Intanal Gans Glazing 46.7 6658 20.0 Doors 11.8 379 1.1 Ceilings 2.6 4988 15.0 GaYR--- Floors 1.1 2037 61 Infiltration 0.6 1078 3.2 Ducts 12237 36.7 CthEr Ventilation 0 0 DLCts Internal gains 3550 10.6 Blower 0 0 ceiliry rogs Adjustments 0 Roas InfiltrAim Total 1 33355, 100.01 Latent Cooling Load 5411 Btuh Overall U-value=0.088 Btuh/ft2-0F Data entries checked. 2013-Jan-22 13 55 54 wrightsoft Right-SudeS Universal 2012 12 1.05 Righl JS Mobile Page 1 ACC-K C�WINDOWS\TEMP�wstmp\d2532496-r-3tc-4271-b78d-ccc4a5gb9881.rup Caic=MJ8 From Door faces. E Job: AVIA/Saunders2013 + wrightsoft Project Summary Date: 1122/2013 Entire House By: Ronald Lee Air Excellence Installation & Service, Inc 3813 Bald Eagle Lane,Jacksonville,FL 32257 Phone 904-923-4967 Fax.904-268-0903 Email.airexcellencejax@comcast.nel Web http//www.airexcelienrefla.com Lic_ Project Information For: Jeremy Saunders 1728 Park Terrace Dr W,Atlantic Beach, FL 32233 Phone: 904-631-6268 Bob Notes: Design Information Weather: Jackson ville/Craig, FL, US Winter Design Conditions Summer Design Conditions Outside db 35 'F Outside clb 91 'F Inside db 70 'F Inside db 74 'F Design TD 35 'F Design TD 17 'F Daily range M Relative humidity 50 % Moisture difference 55 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 20748 Btuh Structure 21118 Btuh Ducts 11161 Btuh Ducts 12237 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 31909 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 33355 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3118 Btuh Ducts 2293 Btuh Heating Cooling Central vent(0 cfirn) 0 Btuh Area(ft ) 1892 1892 Equipment latent load 5411 Btuh Molume(ft3) 17028 17028 Air changes/hour 0.38 O�20 Equipment total load 38766 Btuh Equiv. AVF(cfm) 108 57 Req.total capacity at 0.70 SHR 4.0 ton Heating Equipment Summary Cooling Equipment Summary Make Goodman Make Goodman Trade Goodman Trade Goodman Model ARUF48D14A Cond GSZ130481A AHRI ref 5358275 Coil AHRI ref 5358275 Efficiency 8 HSPF Efficiency 13 SEER Heating input 44000 MBtuh Sensible cooling 24500 Btuh Heating output 44000 Btuh @ 47'F Latent cooling 10500 Btuh Temperature rise 28 'F Total cooling 35000 Btuh Actual air flow 1435 cfm Actual air flow 1435 cfm Air flow factor 0.046 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat Load sensible heat ratio 0.86 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-Jan-22 13 55 54 wrightSOft Right-Suite(&universal 2012 12 1 05 Right AD Mobile Page 1 C�WINDOWS\TEMP�wstmpW2532496-c3fc-4271-b78d-ccc4a59b9881 rup Calc=MA Front Door faces. E r%1 MEN CERTIFIEDT www.atiridirectory.org Certificate of Product Ratings AHRI Certified Reference Number: 5358275 Date: 1/22/2013 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: GSZ130481A* Indoor Unit Model Number: ARUF48D14A* Manufacturer: GOODMAN MANUFACTURING CO., LP. Trade/Brand name: GOODMAN, JANITROL, AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR CONDITIONING AND HEATING, ENERGI AIR Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP. Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity(Btuh): 45000* EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Heating Capacity(Btuh) @ 47 F: 44000* Region IV HSPF Rating (Heating): 8.00* Heating Capacity(Btuh) @ 17 F: 27000 Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. ZISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauftworized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or citherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate ran be verified at www.ahridirectory.org, Air-Conditioning,Heating, click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on no ILI and Refrigeration Institute which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. LL_ 02012 Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO.: 130033628794932032 wrightsoft Right-M Worksheet Job: AE/IA/Saunders2013 Entire House Date: 1/22/2013 By: Ronald Lee Air Excellence Installation & Service, Inc 3813 Bald Eagle Lane.Jacksonville.FL 32257 Phone.904-923-4967 Fax:904-268-0903 Email.airexcellencejax@comrasl net Web http://www airexcellencefla com Lt., 1 Room name Entire House First Floor 2 Exposed wall 188.0 ft 188.0 ft 3 Room height 90 ft d 9'0 ft heat/cool 4 Room dimensions 1'0 x 1892.0 ft 5 Room area 1892.0 ft' 1892.0 ft' ion U-value Or HTM Area (ft') Load Area (ft') Load (Btuh/ftl-*F) (Btuh/ft') or perimeter (ft) I Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat I Cool 6 128-Obw 0.097 n 3.36 1-60 324 293 984 469 324 293 984 469 1 D-c2ow 0.570 n 19.72 21'48 31 0 608 662 31 0 608 662 128-Obw 0,097 e 3.36 1.60 522 475 1595 761 522 475 1595 761 t—G ID-c2ow O�570 e 1932 6158 47 0 920 2967 47 0 920 2967 1 12B-Obw 0.097 : 3.36 I.W 324 295 990 472 324 295 990 472 1 D-c2aw 0.570 9.72 25.73 29 0 575 750 29 0 575 750 1:::D1 2B-Obw 0.097 w 136 1.60 522 454 1524 727 522 454 1524 727 G 1 D-c2ow 0.570 w 19.72 63.58 36 0 707 2278 36 0 707 2278 11 DO 0.390 w 13.49 11.82 32 32 433 379 32 32 433 379 C 16B-19ad 0.049 1.70 2.64 1892 1892 3208 4988 1892 1892 3208 4988 F 20P-11t 0.078 2,70 1.08 1892 1892 5106 2037 1892 1892 5106 2037 6 C)AED excursion oj i i i Envelope lossigain 16650 16490 16C,501 12 8) Infiltration 4098 1078 4098 1078 b) Room ventilation 0 0 0 0 13 Internal gains Occupants @ 230 5 1150 5 1150 Appliancesiother 2400 2400 Subtotal(lines 6 to 13) 20748 21118 20748. 21118 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 20748 21118 20748 21118 15 Duct loads 54% 58% 111611 12237 54"% 58% 11161 12237, FTotal room load 31909 33355 311909 33355 Ak required(cfm) 1 4351 14351 435 14351 Calculations approved by ACCA to meet all reauirements of Manual J 8th Ed. +fh- wriightsc)ift 2013-Jan-22 13 55 54 Right-Suite(g)Universal 2012 12 1.05 Right J9)Mobile Page I AC—'K C,\WINDOWS\TEMP\wstmp�d2532496-c3fc-4271-b78d-ccc4a59b9881 rup Calc=MJ8 Front Door fares: E Job: AE/IA/Saunders20113 wrightsoft Component Constructions Date: 1122/2013 Entire House By: Ronald Lee Air Excellence Installation & Service, Inc 3813 Bald Eagle Lane,Jacksonville,FL 32257 Phone.904-923-4967 Fax.904-268-0903 Email.airexcellencejax@comcast.net Web ht1p./twwwairexcellencefla com Lic Project Information For.- Jeremy Saunders 1728 Park Terrace Dr W,Atlantic Beach, FIL 32233 Phone: 904-631-6268 Bob Design Conditions Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature(oF) 70 74 Elevation: 43 ft Design TD('F) 35 17 Latitude: 30oN Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 8.4 55.0 Dry bulb('F) 35 91 Infiltration: Daily range('F) - 17 M Method Simplified Wet bulb('F) - 77 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Cig HTM Gain it' BtLitiffil-T ftl-'FfBtuh Btuhtft' Btuh BU)M' Btuh Walls 12B-Obw�Frm wall,brk 4"ext,r-1 1 cav ins, 1/2"gypsum board int n 293 0.097 11�0 3.36 984 1M 469 fnsh,2"x4"wood frm e 475 0.097 11.0 3.36 1595 1.60 761 s 295 0.097 11.0 3.36 990 1.60 472 w 454 0.097 111�0 3.36 1524 1.60 727 all 1517 0097 11'0 3,36 5093 1 60 2429 Partitions (none) Windows 1 D-c2ow:2 glazing,clr outr,air gas,wd frm mat,cir innr, 1/4"gap, n 31 0.570 0 19.7 608 21.5 662 1/8"thk e 47 0,570 0 19.7 920 63.6 2967 s 29 0.570 0 19.7 575 25.7 750 w 36 0.570 0 193 707 63.6 2278 all 143 0.570 0 19.7 2810 46.7 6658 Doors 11 DO:Door,wd sc type w 32 0.390 0 13.5 433 11.8 379 Ceilings 168-19a&Attic ceiling,asphalt shingles roof mat,r-19 cell ins, 1/2" 1892 0.049 19�0 1.70 3208 2.64 4988 gypsum board int frish Floors 20P-1 ft Fir floor,wd fir, 1"thkns,tile flr fnsh,r-1 I ext ins,amb ovr 1892 0.078 11.0 2.70 5106 1.08 2037 2013-Jan-22 13 55:54 wrightSOft R,g ht-Su it e(&U n tv er sal 20 12 12 1�05 R ight J(&Nio bile Page I C:kWNDOWS�TEMPkwstmpW2532496-c3fc-4271-b78d-ccc4a59b9881.rup Calc=MJ8 FrontDoorfaces E Job: AEIIA/Saunders;20113 wrightsoft AED Assessment Date: 1122J2013 Entire House By: Ronald Lee Air Excellence Installation & Service, Inc 3813 Bald Eagle Lane,Jacksonville,FL 32257 Phone 904-923-4967 Fax 904-268-0903 Email:airexcellencejax@r-omcast net Web httpWwwwairexcellencefla com Lic 7 Project Information For: Jeremy Saunders 1728 Park Terrace Dr W,Atlantic Beach, FL 32233 Phone: 904-631-6268 Bob Design Conditions L Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature('F) 70 74 Elevation: 43 ft Design TD(oF) 35 17 Latitude: 30'N Relative humidity 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 8.4 55.0 Dry bulb('F) 35 91 Infiltration: Daily range ff) - 17 M V\Let bulb('F) - 77 Wind speed (mph) 15.0 7.5 Test for Adequate Exposure Diversity Hourly Glazing Load 9,OOE- 8100E_ 7,00(- 6,OOE- 5,OOE 4,OOE- 3,OOE- 2,OOE- 1 ,OOE- 0. 8 9 10 11 12 13 14 15 16 17 18 19 20 Hour of Day X HoWy Aer.V PED lirrit Maximum hourly glazing load exceeds average by 15.0%. House has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh 2013-Jan-22 13 55 54 wrightsoft Right-Suite(&Universal 2012 12 1 05 Right J8 Mobile Page 1 C.\VnNDOWS\TEMP�wstmp�d2532496-c3fc-4271-b78d-cce4a59b9881 rup Calc=MJ8 Front Door faces E N First Floor f it st I foo IF-] ------------- Job#: AEIIA/Saunders2013 Air Excellence Installation & Service,.. Scale: 1 : 97 Performed by Ronald Lee for: Page I Jeremy Saunders 3813 Bald Eagle Lane Right-SuiteS Universal 2012 1728 Park Terrace Dr W Jacksonville, FL 32257 12.1.05 Right JG Mobile Atlantic Beach, FL 32233 Phone: 904-923-4967 Fax: 904-268-0903 2013-Jan-22 13:55�55 Phone:904-631-6268 Bob http://www.airexcellencefla.com airexcellencejax@... -c3fcA271-b78d-ccc4a59b9881.rup