79 Shell St (vault) JOB ADDRESS PROPERTYOWNER ayoi--703v PERMIT NUMBER q34-Y- 7 V 83 DATE I D INSPECTIONS: FOOTING -9 SLAB iv-30 - 5 k TIE BEAM LINTEL NAILING/SHEATHING FRAMING/COVER UP INSULATION /2 - a Zt FINAL BUILDING _ 9 CERTIFICATE OF OCCUPANCY S 4 9 ELECTRICAL PERMIT# /-7LIO 9 T P / 7 Y o Y INSPECTIONS ROUGH / ;)— 16-5 S FINAL MECHANICAL PERMIT# 474-14 INSPECTIONS ROUGH /.)--/64 S FINAL 9 PL UMBING PERMIT# / 7 INSPECTIONS ROUGH/UNDER SLAB /0 - Z? - 9Y TOPOUT WATER/SEWER FINAL k -7 �- s= Zo s✓z 3 -A"-3X7 r i, CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD f =r ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5826 INSPECTION EMAIL REQUEST: Building-dept(d)coab.us Application Number . . . . . 07-00001069 Date 7/26/07 Property Address . . . . . . 79 SHELL ST Application type description MECHANICAL ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc INSTALL 1 CU & 1 AHU ----------------------------------------------------------------------------- Owner Contractor - ------------------------ ----------------------- BOLE THIGPEN HEATING & COOLING INC. 2801 DAWN ROAD ATLANTIC BEACH FL 32233 JACKSONVILLE FL 32207 (904) 448-1962 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL PERMIT Additional desc . . Permit Fee . . . . 71 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 1/22/08 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 71 . 00 71 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 71 . 00 71 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. 77- CITY OF ATLANTIC BEACH r' MECHANICAL PERMIT APPLICATION Date: Property Address: Owner: Telephone #:31 a`C�00�� Contractor: S h .L Telephone#: 9 to CA �' Contractor Address: 0u3 o 1 �o-vo � Fax#• � �I 11� O In consideration of permit given for doing the work as described in the above statement,we hereby agree to perform said work in accordance with the attached plans and specifications which are a part hereof and in accordance with the City of Atlantic Beach ordinances and standards of good practice listed therein. Type of Heating Fuel: If other construction is being done on this building or site,list the building permit number: Electric ❑ Gas: LP Natural _Central Utility ❑ Oil ❑ Other—Specify MECHANICAL EQUIPMENT TO BE INSTALLED NATURE OF WORK � Heat _Space _Recessed Central _Floor Residential ,;ZAir Conditioning: RoomCentral ❑ Duct System: Material Thickness ❑ Commercial Maximum capacity cfin ❑ Refrigeration ❑ New Building ❑ Cooling Tower:Capacity Pm Ll Fire Sprinklers:Number of Heads ❑ Existing Building ❑ Elevator: _— Manlift Escalator (Number) ❑ Replacement of Existing System ❑ Gasoline Pumps (Number) ❑ Tanks (Number) ❑ New Installation 13 LPG Containers (Number) (No system previously installed) i ❑ Unfired Pressure Vessel ❑ Extension or Add-on to Existing System ❑ Boilers ❑ Gas Piping ❑ Other-Specify ❑ Other—Specify LIST ALL EQUIPMENT AIR CONDITIONING,REFRIGERATION EQUIPMENT&CONDENSOR'S Approving Number Units Description Model# Manufacturer Ton's Agency ? o �Tw�2 30 —Tri aLA L HEATING—FURNACES,BOILERS,FIREPLACES&AIR HANDLER'S Approving Number Units Description Model# Manufacturer BTU's Agency LA TANKS Nominal Capacity Type Liquid Serial Approving How Many &Dimensions Contained Manufacturer No. Aitency 800 Seminole Road•Atlantic Beach,Florida 32233-5445 Phone: (904)247-5800• Fax: (904)247-5845 • http://www.ci.atiantic-beach.fLus OF ATLANT CITY00 EMINOLEICH ROAD S ATLANTIC BEACH,FLORIDA 32233-5445 rS� TELEPHONE:(904)247-5800 �) FAX: (904)247-5805 SUNCOM: 852-5800 http://ci.atlantic-beach.fl.us April 6, 2005 Mr. Douglas S Doane 79 Shell Rd Atlantic Beach, FL 32233-5834 Subject: Atlantic Beach City Code,Chapter 6,Buildings and Building Regulations. Dear Mr. Doane, Duval County tax records identify you as the owner of the following property in the City of Atlantic Beach, Florida: Re: 79 Shell Rd A/k/a: 15-82 09-2S-29E Ocean Grove Not S/D PT Lot 7, Lot 8 Block 7 RE# 169583-0000 The purpose of this is Correspondence is to serve as an Official Notification of Violation. You have been identified as being in violation of the Florida Building Code, Sections 104.1 and 105.6, and under Atlantic Beach City Code: Chapter 6, Sec 6-16 Adoption of Florida Building Code. 1. Construction of an apartment within a single family dwelling 2. Failing to provide design plans and specifications. 3. Failing to have the required inspections. On April 4, 2005, the City of Atlantic Beach was notified that you had your property listed for sale in a single family zoned district listed as having a full apartment with kitchen. Research revealed that this apartment as shown was never permitted, nor inspected. As a non-permitted alteration to your home, you will be required to bring the apartment into code. All past and future alterations, modifications or changes to the apartment will have to be approved, permitted and inspected by the Building Department. As Code Enforcement Officer for the City of Atlantic Beach, I am granting you 1 week from receipt of this notification to arrange a meeting with the Building Official to discuss what is required to bring your property into compliance with current zoning and building regulations. Furthermore I would remind you of your responsibilities as a homeowner to abide by the regulations of the city, county and state, and that the existing building and zoning violations can result in measures that may require the disconnection of utilities, condemnation of your property and can include fines of up to $500.00 per day, per violation from the Code Enforcement Board. Should you have any questions or concerns involving this matter, you can contact Code Enforcement at(904) 247-5855, the Building Official, Mr. Don Ford at(904) 247-5826, and the Zoning Official Ms. Sonya Doerr at (904) 247-5826. ALEXANDER J. SHERRER Code Enforcement Officer cc: Public Safety Director Building Dept COPY Zoning Dept Ms. Malia Finger-Bingeman Realty Sales, Inc C�ertiftrate of (wccu ttitc (situ of ,�1tl�ilttlt �,�EttCI� — �lori�o Department of +,wilding nspcctinu This Certificate issued pursuant to the requirements of Section 103.8 of the Southern Standard Building Code certifying that at the time of issuance this structure was in compliance with the i various ordinances regulating building construction or use. For the following. Single Family Residence Bldg.Permit No. 17334 Ue Classification g s Group w.frame Type ConstructionSf Fire District Atlantic Beach Owner of Building Douglas Doane Address 9 Shell Street Buil ' g Address _ Localitr�} tt i r Reach, FT 3 1 By: DON C FORD Building Official' Date: _ POST IN A CONSPICUOUS PLACE Building Department 904-_247-580_5_ p. l T4 ir'l1\3CK-)5 A-zS C17Y OF AT—ANTIC BEACH CONSTRUCTION PERMI � S€ �2 Cumf DATE +1/111 Ad=C pre IE,S�l L E . JOB ADDRESS 7 0/ PERMRTEE PERMr= ADDRESS REOUESTING PERMISSION FROM THE CITY OF ATLANTIC SP-Ac 3 N ' y?-3130 LOCATIONS: (REFERENCE TO CROSS-STREET) -- I APPUCANT DECLARES THAT PRIOR TO FILING THIS A 1 EXl57ING UTILITIES, BOTH AERIAL AND UNDERGROUN SKETCHES. A LETTER OF NOTIFICATION WAS MAILED TO THE FOL JACK50NVII F ELECTRIC AUTHORITY YES ( J NO ( ) DATE: BELL SOUTH TELEPHONE COMPANY YES ( ) NO ( ) DATE: FERRELL GAS Y— ( ) NO ( ) OAT£: MEDIA ONE CABLE TV YES f ) NO ( ) DATE: 2. WHENEVER NECESSARY FOR THE CONSTRUCTION, REPAIR, IMPROVEMENT, MAINTENANCE, SAFE AND EFFICIENT OPERATION, ALTERATION OR RELOCATION OF ALL. OR ANY PORTION OF SAID STREET OR EASEMENT AS DETERMINED By THE DIRECTOR OF PUBLIC WORKS, ANY OR ALL OF SAID POLES, WIRES, PIPES, CABLES OR OTHER FACIUTIES AND APPURTENANCES AUTHORIZED HEREUNDER, SHALL BE IMMEDIATELY REMOVED FROM SAID 57REET OR EASEMENT OR RESET OR RELOCATED HEREON AS REOUIRED BY THE DIRECTOR OF PUBUC WORKS, AND AT THE EXPENSE OF THE PERMITTEE UHLE55 REIMBURSEMENT IS AUTHORIZED, 3. ALL WORK SHALL MEET CITY OF ATLANTIC BEACH OR FLORIDA DEPARTMENT OF TRANSPIRATION STANDARDS AND BE PERFORMED UNDER THE SUPERVISION //OF OM IJ/J I�/yrc� (CON(T �RAC [./TOR'S PROJECT SUPERINTENDENT) LOCATED AT 60 3 r / - ( 5, J, ' TELEPHONE NO..2 Y 9- I:; 1 Z 4. ALL MATERIALS AND EOUIPMENT SHALL BE SUBJECT TO INSPECTION BY THE DIRECTOR OF PUSUC WORKS OR H15 DESIGNEE. 5. Au CITY PROPERTY SHALL BE RESTORED TO ITS ORIGINAL CONDITION AS FAR A5 PRACTICAL, IN KEEPING WITH CITY SPECIFICATIONS AND THE MANNER SATISFACTORY TO THE CITY. 6. A SKETCH OR PLANS COVERING DETAILS OF THIS INSTALLATION SHALL BE MADE A PART OF THIS PERMIT. 7. THIS PERMITTEE SHALL COMMENCE ACTUAL CONSTRUCTION IN GOOD FAITH WITHIN 7 DAYS FROM THE DAY OF SAID PERMIT APPROVAL AND SHALL BE COMPUTED WITHIN /P DAYS. IF THE BEGINNING DATE IS MORE THAN 60 DAYS FROM DATE OF PERMIT APPROVAL, THEN PERMITTEE MUST REVIEW THE PERMIT WITH THE DIRECTOR OF PUBLIC WORKS TO MAK£ SURE NO CHANGES HAVE OCCURRED IN THE AREA THAT WOULD AFFECT THE PERMITTED CONSTRUCTION, 8. IT IS UNDERSTOOD AND AGREED THAT THE RIGHTS AND PRIVILEGES HEREIN SET OUT ARE GRANTED ONLY TO THE EXTENT OF THE CITY'S RIGHT, TITLE AND INTEREST IN THE LAND TO BE ENTERED UPON AND USED BY THE HOLDER, AND THE HOLDER WILD, AT ALL TIMES, ASSUME ALL R15K OF AND INDEMNIFY, DEFEND, AND SAVE HARMLESS THE CITY OF ATLANTIC BEACH FROM AND AGAINST ANY AND ALL LOSS, DAMAGE, AND COST OF EXPENSES ARISING IN ANY MANNER OF THE EXERCISE OR ATTEMPTED EXERCISES BY THE HOLDER OF THE AFORESAID RIGHTS AND PRIVILEGES, 9. THE DIRECTOR OF PUBLIC WORKS SHALL BE NOTIFIED TWENTY-FOUR (24) HOURS PRIOR TO STARTING WORK AND AGAIN IMMEDIATELY UPON COMPLETION. V F -oR.wA GeWiYrY aF L�lyAC � o:., �ac,Nt SUBMITTED BY. (PLACE CORPORATE SEAL IF APPUCA81 SWORN TO AND SUBSCRIBED BE RE ME THIS 134�DAY O i ZO(7L MAUREEN TONG Notary CommissionPsE 02 State Ot Rondo NOTARY PU IC My Commission iort 6(pires Mar 31,20 r GJ Commission it CC72D781 ,�I 01f Sea)Cr CGeU✓+ OvfS Building Department 904-247-5805 p.2 MAP SHOWING BDUNDARY SURVEY OF. LOT 8, BLOCK 7, OCEAN GROVE, UNIT NO.I,AS RECORDED IN PLAT BOOK 15, PAGE 82 OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY,FLORIDA.. N I LOT� BLOCK7 I LOT 2, 6t0CK 7 �yyL[' I C'onc. Pdfiti a w.ed Easrmrn/.iY��Ij; !LAW I Found/'/ranP pc '19.x' i.e' ��}^i.::,•:.�cs' I� ;,, .�� y • tyt G'n'o�Fexr g° zo•BQ4 IV 9� • l� • 13Q ILV o •/�K q24 Qrj o S nt o :C O oP n • IL y ^ .\p bP• �n \ O V I.ci ^\ 6� •' • ��(Z Ic Bc VCIN C H'` • t'1. v Z V \ J �- t- 2, RC j. �? :�; _ .. CRL4 �-9i-8o�r 50,00' f L Fcund/"/ion Pipe m 4- �+ I(N•/QJ 'SPEC L ST.VAc r 40'1,?/6Hr OF-IVAY , Nyeran/ /,,,tilt[ vi.PT.Po.4�1 NOTES : C o Legend NO BUILDING RESTRICTION LINE BY PLAT BUT THERE MAY BE BRL Deno/cc Bu!/dir�,fl-s�rity/dn L/ne RESTRICTION LINES OR EASEMENTS THAT AFFECT THIS PROPERTY BY ZONING OR RECORDED IN THE PUBLIC RECORDS K Dcnote5 OaK Trre OF THIS COUNTY THAT ARE NOT SHOWN ON THIS SURVEY. P Ornofoy Palm Tire G) THIS PROPERTY LIES IN FLOOD ZONE"X"'BY FLOOD MAPS REVI5ED 4/17/1989,COMMUNITY PANEL NO.120075 0001 D. 3) BUILDING RESTRICTION LINES SHOWN HEREON ARE BY ZONING PER CLIENT REQUEST. RECh'MXFD 9-25-99 TO SNOW79FZFS G'GA/D L4RGJDURDDEN r/? CERTIFIED TO: ATTORNEYS'TITLE INSURANCE FUND,INC.: DONAH00,DONAH00 B BALL,P.A. � nn I (�p ppLSAN �?Jl4JJUllV !f ©R, LB 6645 PROFESSIONAL LAND SURVEYOR NO.1674 FLORIDA H. BRUCE DURDEN• SIR 1103 SOUTH THIRD STREET DATE: APR(L I , 1998 JACKSONVILLE BEACH, FLORIDA 32250 SCALE: 1--20' (904) 249-7261 FAX (904) 241-1252 THIS MAP OF SURVEY IS NOT VALID UNLESS IT IS SIGNED AND HAS THE ORIGINAL RAISED SEAL OF A FLORIDA LICENSED SURVEYOR. DUIY ur I Office of Builling Off' al• 733 REQUEST FOR IN ECTION 7'V76 Date Permit No. Time A.M. Received PM Job Ad r s Lo ity Owner's Name Contractor UI CONCRETEELECTRICAL PL ING ECHANICAI ing ❑ Footing ❑ Rough Wiring ❑ Rough ❑ Air Cond. & ❑ Re Roofing ❑ Slab F Temp Pole ❑ Top Out ❑ Heating Insulation ❑ Lintel ❑ Final ❑ Sewer ❑ Fire Place C Pre Fab READY FOR INSPECTION M. Mon. Tues. Wed. Thurs. Friday P. A.M. Inspection Made Inspector ` / Certificate of Occupa, y Date `` ❑ J & L HOMES, INC. RESIDENTIAL CONTRACTOR (Lic . # CR CO29277) 445-26 State Road 13 ?AFCAFI Suite 347Jacksonville, Fl 32259 904-699-9725 VACD MAR 1999 MARCH 8, 1999 city Of 814 atlantic ADDENDUM TO PERMIT # 1733 ng and zoBngh 79 SHELL STREET - DOANE RESIDENCE After the Doane residence was permitted, the slab installed, and the framing nearly completed, Mr. Douglas Doane (Owner) received a cash gift from a family member to be used to install a pool and to rough in certain plumbing, electrical, and partition walls in the storage area (603 square feet) above the garage . The space above the garage had already been permitted for air conditioning. The pool was permitted separately. A floor plan of the additional work performed on the area above the garage is included herewith. The additional work includes : Plumbing: supply and drain lines were stubbed out for a future bath (tub, toilet, & lavatory) , supply and drain lines were stubbed out for a future sink and washer, and a supply line was stubbed out for a refrigerator ice maker. Electrical : receptacles and switches were installed in each partitioned room, including GFI circuitry for the future bath and kitchenette, lighting was blanked off according to code . Circuits were installed for a stove, dishwasher, and refrigerator. Partitioning: framing for interior partitioning was completed and is identified on the included drawing as the darkened partitions . Drywall was hung on these interior partitions but has not been finished. All additional work completed on this area was completed according to Code . Mr. Doane wishes to report the above described improvements installed in the storage area to the City of Atlantic Beach Building Department, and he wishes to pay any additional permitti and impact fees deemed `to be due at this time . /� h`- OWNER: ,/ � 1..• CONTRACTOR: ' License # CR CO2 277 C) 00 0 - 4--) Ql m N M Olcu IL m u'7 O rn 3 O LO O p N n 2 M m' Y v II v --) Do 0 d N m S Cx: U K F• Ol I� S Z W W Z E > 3 O O m U o (n � O O 2 N LL O O rn F } L� L� LL LL L� N W X (n N In )n (n m: d d d d d w M M O 3v O O O O O Cl)II � N Q 3 w 0 I� O O N z w Ln rn X n W J M N U C7 a z (ll 3 � o a z_ W p J J J J J U- N 0 C) LO J J O O J U v � F- M U- Q m z II o 3 F- m m F- in N Z c7 0� O S W U W WOD C\j Z Z 3 rn !d X: H O m CD Q �: v War- co F•- pco J O W o N O O N w .Ln M z a m Cl II N W Z J V) X a 3 D C7 O V) -:I- 3 S W V C7 X a a cn F- 3 N N N rJ D V H = O U Z W }- r-1 Z W �- � W 3 N 0 ~ O 00 N a - O 4- d _ x r Ln 3 > y m M U O N m O z N Q - OJ C J O 3 ¢ N C o 0 O S_- U) o (n o � Q CD v Z a ¢ u � S J U V, z x � Z W a O O ¢ N LL) w X Z r LO ry Jw c v ¢ x O M d Ln ; a mm ¢ Q 0 3 CD ��� N .0 Li w Z Z e V V) d O N X N N NM 41 m w Z F 3 W g" ¢O >N N V) O M F- ��� d Z �a D_ W v v v D_ w Ln F ) $w x x x O E X J N N N N M + Q d J =V z 3 o o (n o o Q m; C D_' m Z O O C W) O V W W F- W2 LOV V 3 w w0 O J 41 C y J J Z d O p p ¢ w � m � o co o k Ql m N D \ 00 L M alN U- Ln O m n m co \ 3 O \ Ln v> II d z J 0 0 N N M N 2' U C J r r 2 Z � W W Z � > O LL 3 Cr O m N W Q d' U W af o d' C:) c 2 L/) W w H W C7 E � cm m W Q Ln N In N N h W O O d �CD h O J O O O O O M O F- ,--� W O n O O n .--i N CD f W O Q W QO r O U C7 W d Lo -1 O � Q Z M 0 J J J J J Li v> O O C2, ti J J CD0 J U -Ln O < O LL. H d' Q < V • Ln W J U U U U O O M m 00 N 0 N II � II ~ ~ ao [D ~ m N z .. o z r. J Z H ¢ F- = p O o c W WLLJ - 3 m U 0 N Q D O J = W � W W Z W M: H W O v ^ �•�� �]K� i Q 3 O 00 A o H V O O Ln S�` J W ¢ 0 N N F Z Hd z ¢ J 00 I 6'L7 :Gj N Q F- C) Wm n 2) O W V' O J 7- 111 < (n II = w Z J W a 3 O W O Ln o F- V) Jo V O 3 f F- w J = O V J W W 1.0 d r1 Z Q 0 W N - � 3 • X M O Q L � d U - � LO m N Ln co x X X Ln O D 3 3 O - H O Ln �r Z J Ol � N 0 3 Ln QN O O o s< l M - H I L ¢ 111 L 3 O 0 y ti a - � J � Ln 01 - W � N r LOco w Ol 3 311ui zmz6 cli V) N IT 3<ti a mEo mmm caw m c�\ Ln r N Z r-i Ol uj C 2 Q 2 "" G N N ~ Cl- cm y Z ¢ W U N — CO N O X O �k'k 4k M N N z 3 > LU g� QO NNN � 0 3 Z a.a o L100 Qw J N N N d r.CU 7 D O fN O -� C C Ll' d' m V ~ b0 y O O W O m W m 2 2 3 W � U V J CWJ d 7d 0~d aF Q 4 O 0 Z N p o k CP Cn N to \ co Ln M m N U- w r- Ln O rn 3 Ln nvNM 00 i II c J 00 O m C U V C� H x Z > W W Z F m V LL 3 O O O W Q U W cr LU C7 S C m W Q W W W W W O N N Ln Ln Ln N LL J _ d d d CL d O z ¢ O O O O O O rn f O O W O n O O n N Z O F- M .--i K F W O w O ^ d H N ti V C7 ea W d O Q Z W �n O O ti J J J J J W O J H d' Q o m 0LO 0 J ti W U U U U O S d N II o F- F- co m F- O Ln zCD ui z H x o 0 W Z J •--• N M / LL n W W Z O Q 3C� C, F- V O 00 cc IL v L.L O - C M N � T R!z" J W N N O z o Ln A�•" \ o N F- o W C7a W < o II mm: n w Z J d m J Z n. 3 CD O r O x Lw V 0 1 p d LN H V O N E o w >< d << J O J M >< O V Z L- = Z •-+ W 3LOa- W 3 ��W Ln O n _ - � III III N o LO94, r- >< ><X >< i U VLOLC) DODOpNO>< O >< M L 0 CD E � E II - o ro M <� 131 N o 0 a U W Z Z O d S F- � N N Cl) Z M N j w Q •p�M O N N N 3 z P O V I'll V X X X _T J N N N �U 7 O O N Q8 0 0 � m Cl) 00 o y� Ol m N W � 0 M Ql N W Ln O Cl. N w LO 3 N O Lo I z J co 0 N m N m O Of ti W W2,- m U W I— 3 Cr O C W ¢ m V W Of O m D m 2 (n W N p F H N w III cn cn cn v) v� 7 _ Cl- a- 0- Ca- a w - O O O O M O N p W O I� O O n -4 N Z w x M + d � � N w w 3 � In ¢ U C7 -a Z 0 ¢ Z w O J J J J J W �--� v� O O .+ J J O --J U 0 0 F m a oa m m cn z II o m co F- O N IC � ~ J W O d Z c7 = O 13 m _ S Wu W r- 2 m �- wmz � 7 •�yC-�� a f ¢ W p O H O m O m h W c7 ¢ O In ' N C) V a �f r m N O -C=) fn O a o II ti 2 J r-I a 3 D U O In i = W3o V :m i o d N E- 3 O (n accJ D O VWZLLJ = a �--I W 3 N (n � O III III � � a x S- o 3 V C -m - i CD-- > ' -> N _ O d O N D J JC3C ¢ 3 � I O O H ` p N - o Q 1 rp J U U x Z W O <a w x ¢ F =v N N o v ¢ o O i 0 O� ¢ N O N G W Z Z V 11 N d N N M III 3 ;' ♦- oy.R W tux 4�z Zttz J tp QJ 7� z ¢ a a a V) ,� r > W $r, V (N N V) V V V WJ r x x x F � �- 3 t-1 •sw J x r y N (Ij N Z N ¢ d J NV ooV) 0 3 Q = C m O C G O O w x 2 3 U O 41 H y� V V W O J C J d H W Z 0. 0 o w ~Q H m � r, w C) LL I- M m [L N N 3 Lo NC)C) W d n C13N m 'It < N Q CO CY] z x Z � W W Z � mt N W < CL' U Cr Of O p = V) Li o N O [] QN O O a' L.L. L- W Li LL. m Q J W V) N N V) V) CL CL d c J 0 Z O M O z Q 3 r V W O r- O O r- '-+ N O Mui d r Q o O Z S M U C!7 W O O N c V) N .. 3 O Q Z -d O Z J J J J J LL. �--• U- C7 W K C _r O O Z O O J J O O J • O Q x w �y = Q _< V K t[) 2 J U U U U O Cl m n' d' O I-- m m F- O V) N Z II W m O Z > Z w Q J O < = (D Lu W W W w W �._. S V Y > U Z z Z3 � Q r o m V) �•:UP �� w z z x o w O Q Q O r C] 1a � wco \ coa wo r00 . 0 N Q I -i ,•`�y.� - J O n' V) J f + N O r N OH w xV d w W H < -U' d W m V) o C] II > Z J N O N OZ •-• x W U W F W u N z W m 3 Cl- V) f- V m V .. - O p W W E -< �--i in ti N J C] J J W w O z o O -- O Z 6 W N L ~ w 3 ml O r N L 00 I�ILOLn 3 M > U �oNmo_=o v.m M N <o1� � z V o=ho W 0 W 2 O m - N H U- M Z O -:c _ w Z V) + LO O w JUO N O 3 s� No p L „oNNNONW�<< p W Q n U N �o O w O In a w Z <n<- 2 Q d' O 'n zvc Yuzin Z 2' F- J m i O O V) to J CL zoo o W C] O Q off rp C] J w N x O O m W J O W Q m V) J J Z N Q W W N •wcuou - O C Z Q 3 Z .--� C- X O O C7 W C i N z =oGaom=--— oC O z^� �� N W N ¢ co Vf ti3 smzn Nuc me �o _ n w nwaw a) LO � m � C7m II Q ti (:J N O L CT dp N Q W C7 w Z Z Q O d LLJ d l-- t7 W J N N f7 Z Q F- CJ N t0 d L'i �k.�k�k .0 � O 3 O r > L.LJ Za d d W LO /O .< V) C7 C' .Z-i n CL N N N O W Z Q W X w 3c, Ch mr-. W Q S r H L O 2 1' F MCL x x x o C7 V7 )- 3 CL N x N Z W N >- .� ¢C7 C N i--. U W m U i .. Q G .7 O O V) C] Z K O s z m N N O O W U' Z F- J W 2 2 3 3 O Q d' Q Z O O J V U O m O ^ U- a- W a W d H W W O Q. H N O O N 1-- K V) J co � H m y ^ .--1 00 0 Ln m (D p \ IL Lr) n M N n. n N N00 N 00 \ \ CO z 01 ^ W 1^ O v m N [� II d z Q m O n m � x Z W W Z CD O O V) W Q C U W ' _ Q' p p 2 V) LL LL LL LL LL L� O V) V) N V) V7 a O O O O0 M O .n M z ^ "..� w 0 n O O N z f O V U G7 W p Q Z n O J J J J J LL. w V J J p p J U ^ O O D O U- F- d' Q O O Q aw O U V U U O O d m N p m m 1— O V) v z II II - z LD U� S W UH / 2m VD N W Z 3 w ^ Q Y O J • ^� ^ �•iV v�0$' o FQ3 � o o LLJ cc d°° a) H XLu*.Ir-. ' ` W Q O M N �/ N N •�^ � 6'•J_Q. •LJ n V d Z Q LL /L. C 0 0 C N •"' Q •� ly- O N1 Z J W X � 3 OW to O O C, V,W I Ocm O H r O V Z J W X < oz Q O N M W3 _- � X 3 L 4� 6 <_o�di� -_ d L � ao� <W� _- d A v+ _.. i-oiii ia:z6c�nm N LO a0 L N x x N LO 3 3 O _ N c<io: CP o�oo� _oW Q N a x o M 1; 111 =<W� 3 N ko O < O 3 C foo oo� ox .o L o III L o a co X U J l C) N Q M - W O, j - N NI D Ln =a m W = N � Q N C C vv y O d W C1 (m ~ m W Wyk J 3 N > W �m a N 3 O N N in H H W O w V V V W x x x f d � N N N } J •my Z Q N ' 7 O W N O ~ �C•G Ln o O w 2 U V W d J O O w H m � 41 W O o � rn LO n M N d N N °D 3 d � d n O M N m GO O W W Z C) O O m I V) Q' O O S V) W c w c7 W ti W W W f C o N N V) V) N � o a a a a a _ v w J M� O O O O O O O ..� in O J p W O O O r+ N C O z O d CD N o Q z J J J J J W U ec d OD J J 0 D J I- Q .CD O O W U U U U O O d m m F- O In m m II V) i .... Z Z J Q (3 LLJ _ Z 3 m aoo ¢ 4'V w :A ~ o � O �.LL Q ��/�, f v 3 O X ti Cl) II N J w \ 3 CO. _ o O Z O N N H LO W C U. W < o o II f 1 Z J m J Z r O O 3 0 0 O ��� I 3 d (N F- F OX - J OJ C:> MLO F- - - z z w F- 3 .--� ` W< o z w - �c = zom- O CL d U �ioo .nm =3 �o�+�u poi V) C - III III "' _ _ - Lf) >< >< LO 3 3 O y�N000 oW: CO - N < >< LO 3 d O V W e M - OD II z-.?.'o--E 3 zuo" - n : M N O v w Z Z O 9 N N C`) X •p w �k�� M N > I••V ��'+ 3 o Z a a. a Ln 3 r..l •gw O Vl N V1 O X X X SU N N N coo O O w J C � V V '� d 1- O O < H m . rn ao w o \ w I- M u CL N N w 3 N LO \ \ Ol Ol W N n O LD N c0 ch z Q O O II y m CC U (� n S Z w w z f L) w 3 O O N w ¢ ccv w 0� v1 w 0 U-III o w w w w V) V1 fn V) N LO 0 M O O O O O O M , z - � X w 0 ^ O O r .•-� N _f O N M r+ z � 3 CL Z J J J J J w L: O J J i J U O O w Q U O a- m (n N Z II O C) J � H W C / '• Z S W V Ow ��G •• � LL �,cjP < 3 O co a) Q c :J w W < ndl- N h, Y O < N 1 d aL' 5 O V d oa 1 •--1 � C N O M z U o V) xwv c7 O N : 3 d Vl F- 3 Q. <<'-'•' - c OV Z W oz w N w 3 N y o 7 p = - O III III a _ � X C L �'U - .ct3 =J o 3 �-uozo��o L C of oCY ioxo�< > y s o O a1 o<- N a0 - W 7 W 3 < 0 6 2 O m O Z O 6O < H o N O Z V1 �oo'e aoo oo_ J Z V7•O J J O O q N J W - � W< 0 U I L V' :o N 03 ' Z O W W O Z V7 y "um oma~ O S «' O F- W d U -� x e-i 4� - v O O < w a) ? - - Z f J U ooLL J W W d X J N w • ti V D m W J 0 N - Z - W < N m < W Wz- w O C7 W O N J W N W < W G Q � E 2 C7 D O a) Ln O G7 N � L Ol O N q W C7 Q U N .-�. yo xv� � II y4. Lu w Z Z v d J O 3 a1 F- .ti.• K \ W J O .J-i III 3 N N (") 2 (O w >� m ^ .- > W �T • Z d d a V) y C7 d' Z Z G1., < V1 V1 N H W W J 3 w cl W < 2 CL O V V V W 2 2' H C x x X F c:J N F-• XV J V) Y N W B ¢ r Q •p5p m ic . • .7 O O N O O Q C' Q C K H• G ism � N W"' O O w 1- •-• Z F- J W O +-� I--• C rZ S x 3 U O Q 1' < Z O J U V W m O K Z CL d J w d W a CL w W O d FV) CD O F- a' V) J O M do N LO O M Li n M N a LO \ \ a) c N O) ^ W Ln n O.N v m N CD m N I{ N Q co m N r N C:f = Z CID W W Z m U- k- 3 O O c { N O O 2 Ln � N E Z O lL L1. l.L L.L li. n w Q III o V) V) V) V) Ln X: O a a a N W J CD a a O O O O O . O i Z O '- p LO W O O 117 O l.f) r w O X X r-1 Lf) CD cli 1O III 3 x ELo o 3III U L� Z O x LO O Q Z V O O d x LO o r N 3 J -J O O -J U m U U O F- a J _ N - J III ,r, �' � � m m Ln Q p 3 co X CD Q a Lr) c z w O LO Q III >< N Ln LO .' = x -N. ' z o Q 3 3 III Q:(P „Q'�VV;[y ui o p III '< °' g ~ N N J X 3 N d ,Q- LO III N3 Ln Z III III LO w w w 3 y N Z I- LO Ln III co I- f N X X 2 W N LO n J N 3 L 3 N0 LL, w d o w w z x 3 O. ~ r CS r- LO III ° � _ a III 3 = W LO X 3 1113: :3 N a zo.ay. - �c _.a'c�� N Lf) O - - 3 x C .i a`eo� - In O N 0 C7 IIIN III " �_� •_���_'- ~ xi N :no<Foi��:oi=o X y LOU" ] O III3 III III 3 C:) W d Ln LO X X x z3 LnLn LnN N I31 III III 3 N .... o. cn r. cn r w W I^ O J 2 X szro<rs-vi=�av�oWx�n- N a' • to t\ w Ln 3 "oNW <Fo --i N N N a J X II C) -Cc °Co uaWcicF<W<im .� a> � w O V 0 LD LD aX H m o-•r Q F >< 117 W w w LL_ S V X .-+ 3 oo�c`�ox �o • J J J F O � III `u m- io< O 3I- N Noce o.n p 0 0 N M o ." Lj III W W w r X J 1^a O O O O cc m � - �' 3 N t^ III L.f) N UJ CD m J Ln X <<iiaso-<io<<v�ov� 07 O a� Z X w N ,o J L17 3 Ll') LO r II N O Lo O J 3 N c u `l' x 0 III III 3 C to N = U-) CL ^ w p Z V m m m J �- a ¢ x N M W w W w N N f-- X LO U W '4k J J J U O = 3 W ; w .z zaaao wa x3 — a A Q aaa N Z y� O N N N O V O O CJ L17 3 Q -IT 10 H N N 00 N ✓) a' ti m r•-' Z '--I N O _T x x x p W J O ocv ¢� � 3 ''�� 3 '' J �V J Ln > °a ppN J = E E r '? w = m J O O O Ln O p O O O O W J L a, V CL H W W H ~ O O V) V- H cc H m . co C:) 41 N N 3 Ln L) .--� z N ' M ^ W Ln N II• O C Q 00 O n m N N � u L3 00 r x Z J W W Z f O m V W < 3 Cr O � w Z I N CfW • Q H � O z " w l •• O III W L� W W W c N u O O Q to N N N N z in Q C) p a a d CL a s M O O 0 O V1 W Q W O Q Cl- O F-• >< '--� — O O 11'1 O Ln f--i N -f Z O O LO .•� Lfl Z U ^ � O ,� III X N wi o o X 3 III 3 o Q z _ O z • O �Q O °a rn Q 2 V X 3 C) ' J _J D O J V J N III Cl) O ,� a 1-- Q > J O — cy. M = O 3 O O F-- V- co Cc W 0_ 0 0 Z X X J LO LLJ V) V) to 0 W 3 III nl = O J ^ N �c v - o X 3 V O O N J III IN- Q O O W CO V) o Ln Q %U LU 0OOOxd o X z o T 2: CD o III � ¢ g., Q��/ o= N O 3 O lD 3 Ln N Y,~a�t ` ~ Cl N III o O V W V) Z H Q a w N III ><X z Z V) nx0J f <t 3 O III M - F -L7 J z z V) C Z X O L w O Lfl X Ln 3 O O O N �-• H o 3 Cj� H O a F- N 1 12 N z..00 o n Q 3 III3 O o w II C, v o 0 o _ S O N O w X Ln ~ } L- J O N O M X V) '^ III 3 3 O m < ouo� - � M - III C 3 ILn d' ll L LIl Lfl _ N U joNco .-r 3 X Ln L N C - o,�-eox z� III 3 0) oa= r = ~ N > •N s o��<aW LLo U') III C) N III >< l0 mss _ C) X 3 N Ci Ln CV ^ 3 X N CD Ln o Lu m w L'-' O X v x M LO N" - L O 3 LC'1 a oOo< LO 0 C� Ln s Ln 111 Cl) > x JZ LO ^ O 30 X 3 == =FOV- .----�,..s N _ Ln ^ Ln o w N X C � N N CD Q 3 III v S- c C C m C] ^ y r V) v Q) .. W d X w O O J M J LO N M J a r-� III III 3 L ; w m r aW � Of = u •r Q o a a m z >< _ Z a, z O V) In In w f d• 3 2 `•--1 w O W Q N N N O V W X X x x x m Ln pp N d CL J C C V 3 Q e zr .� ooN wo N 3 0 Ox CD m > W W...= p a a F m f 1- O T- --, N N uu, - C�NO1 m N n I v a 00 m N �. U 'D i � = Z m O C6U LL. F 3 O O o Q i- N � CC H O M Z a m cll v =p Q III O N N N N N o z Ul) Q O C. C. Ci CL CL N -M-� _j J l0 r..1 O O N w J _ O O O O O O o_ a a o rQ- x III w p O Ln p Ln N Z! o o Ln x N vw ~ c7 0 3 M III v L7 o O z O Q O X rn Q 2 R M = it's J J M J V LL. a J III Cl) v v v v p a- S CC 3 0 O > J 1111 I- I--- CO CO V- O N Ocn 2 w a O O Z >< " III Nco m cn O � d 3 ti i cn L/) o w 3 r^ ---- . ? O J N i��`. Y V Cl N X 11 z v O O Q oOw P U- m N O III 4;U � �,0 ; c� C� m x a oLU Z ~ LO co o cf -- o O x III N �N- N 0 3 0 10O 11') V- \ 3 Ln Z ti J Ln 00 /r m wzao v> c o w w Ln zF N Ln o Q Q w X x z a F w W M a .. cn2oJ f Ln III 3 � c7 0 J 5 Z N �-' �' w Z Ln a O to n' O L) m o V) III x N x 3 N x o o w N N C] O O J LO } F- J O N m X III 3 X M III CL Ln 3 Ln N r d oa<o X L u T LO o r o N o 3 III 3 tox .nm � �ss: N � — X > Ln X N N 3 O p $ _ III X O d oio o��F< o x N III >< LO �i,oe'e so" mac' 3 Ln X N - Cl- :3 w C LU O_ X X a W< vououm�� =m O M III Sr, Ln o� mm'Wo'u ZC"iIII III �a� o< - N s ?_ Wo u 2 IU 3 1-4- cli -2z! ism a F- x 117 WmW= 3 3 N > N 3 III = eo v o 3 III Ln O x 3 rn --ouo"o-- -060- N : N X 3 Obi +� smz6aefo m<�n �aav� Ln H W N IV N CD Q 3 UI I^I 3 L r C C m 1= " N N O) W CL >< 4� w p p J M J >> �III d• OO N "to 3 M g cn Q -x r, t X05 =*t:: of - Xln _ n W $� Z W N = CC Q a a a J m z Ln Ln3 .r Z o•' O N N N w f •--� cY = O W N N N C] V W 3 co N �. x x x m J O C V C LU n O N W O N H Q C C CC CC m 7 Z O O Gsl m 7 O O w W dx 2 2 3 H f J .rJ N CL n• a H X V 2 r-1 O O Q w z r H m i aC H 4; C-) c r- (h N N N rn 3 d z M 01 W Cj p Q m m Q m T V W I- 3 O O N W Q of U W Q' D D 2 (n LL N N V) (n N N N LL LL 11 N V) m C t CD d d d d CL J a N O O O O O O O x x O z a w r- p O O m O .-+ N LO 2 f O V W � O OLj C 2 Z U U U U O ZD C J H O F- F- m m F- O N 3 O Z F a z 3 C7 a w O z _- C, a w 0 x co ;p O W J W �' N E Q H % v� z C z w W z w w F- � 0] N Q _ p N � v' M: J C W N W w VI J cn 0- C)O M 41 � of - Cl N 'N i- W jLL zi zo N <oa w<_ �N000 N N Q iUoeio= �n V vo II d mo= C+ U 0 1f1 N 'I� o w Noor OC\j s I (V • C :T a LP - � W > i Ol O Q C) G N m N ZZ III N ,� � �P z N N M N _ rp OJ > W X a a 3 Z a N V1 N O' NCD ^ r H O X X X 3 N U w o: zm I 41 OOw ry o x x a o f 5 V V Z d 4 O O � m N { d OD M o ll n Ol O n M N d n N N rn 3 w Lo w to Cv O c m N m I� ti Q w om v N U -D = Z z r � W W Z � u w I- 3 Cr O N w Q C)r-' c-) w CY-' cy: p p 2 N W D S LL U-O W W W Q to N In N Ln N O d a d d d c J a O O O O O 00 O = < W .r o z o x � O V � U C.7 O p Q Z CL o O v H J J p p J V r N W H K Q x U U U U O d < J F co co H p to - � 3 Z N V) Q 'UP O .'• o a w ; o O s o t- .r.. ip J N00 y•rb �� ��\ J �O Q V, o r- w � w w f m z z H p O N ~ o 3 i J NCL N N C0 V X10 3 O O V' zoo Ln II c6^W io�so O d' XN d O _ _ N U iouo- _ iWi•=- p _�"� X 3 x w W oLL =sm - d Ln � � N 3 =a:6vetom ,nu`czc� d N > L O CD QCL s � a gg w Z z III N 4' N N f'7 �. �O N •py w z#Z=* .00. Qd d d _M X O N N N 10 N C� N N N ?C 3 X X X LO O N J c v v II r On 7 z m 3 —"� v LA'm O0J ow -j cx a, x x 3 O ♦ � V V Z 2 �' a � a 0 0 � m �O 0. W ^ a-,O -- z f� M 0- N N CO 3 n y N 01 W l0 M n O � m N m II o Q 00 O z � III ° w rw- 3 " Cr CD W Q = U W C-1 = O O 2 N U- >< >< III E z o Ln v w w w w w w 4 x N N N V) N N CL CL a. Cl. m : J CL 3 3 3 3 O O O O O O O _z p o III O O Ln O Ln ,� N W O = ll� N r/ Ln z H O x 2 Ln 3 CY II d U c.7 V O O III J J J -i Q V H J _J 0 O J U V) N x O w ~ 2/ Q U U U U O M o m V) _ Z z a III III O Q Z >< • x x '-' z 2 Ln z O J a O Q rn 3 III fX SVP ,O'W. -' Cf o II '°�'-' �Q1 3 x �` CD o -`` iD J M N N ¢ 3 III N b9.-- Ln Z z p w 3 w w w N X L m xn 5 Z F — N rn O N N — m V = 3 O] H IJ >< +> - Ln Ln III L r J C - w d < - - x d �n o Ln _- N V) 3 N " Ln III > O U " o�'"'zooioo,nm 3 o��u O Ln ' CYC\j CP eosoo- _ 3 O ^d III "' o x LO. xza�o's- 3 •..oma- - - N III III No�W"�„W - N O x N L C'7 Ln 111 N - t v rn III V) - p O v X o >< 3 m _ 3 < O - p N N >< z o u y o-- �t L u x m"u... III w C « N Ln n � o] d ><Ln 3 L G w Z z F- III 3 N Ln Of cn z W � an. a x Z 'aQ• ao L/1) In to 3 X N O N N N x x x J -IT -r e° o CDL" 3 Q d w m f---`�—'{ W y� F- 0 o w �y C 4 T S 2 3 J al U V d 0 O O H m N y� 01 CO W n Ol � O \7" � W I- M N d CO N N 3 n C) LLJ LO n O c0 N m f ¢ c0 O N III O II _ m - Z w w z � (n 3 Cr O w ¢ � v w G X R cm 2 In W _ N � X V; In c7 N x z 3 F z o cl� 3 Li U- Li W m w < �- x N fn N N N p 1- Q. Q_ Q. Q, Q_ a •-• > W O O O O O CO O 'l J O 2 J S �• � z a a' to X wC, p o w C,.) O O u O Ln N N w p a' W a J — 3 -4 LO Z Cc H O o O < x a C e O V W d S Nt Z O VF- X = U a Q 2 V d X O ¢ �-. K U O O w _ _3 N J J J J J W Q v - III 3 J o o J v F- of ¢ Ln W U U U U O O Q- < m J O O X O V) J W w Nt Q D 3 O U O 3 Lr) Zr Z F- < O < Z w O N to cc) z F- w o V) m z - �C�R:- w O C O J _ Q Q 2 Q V X 6LJ Q .1P d C O i O CD O V1 x O w O W n V to J O ° N X ��� N M J WV) N d. N IPJ d O � Q F- v v w w ✓> Fn z w w w F- �-•• z < N E m N S Q a X H a L V) a7 2 rn O p Ln) w 3 F- O r O 0 O_ 3 m W O. - x W N W N J N a a = w w O O W 1- N _ i=` - W in D H a F- a X O 3 C ra X C N It L- U �ov�o o�uoo�oo�nm C =i o-oo o-- O 0 z _ >< O az n< N -- 3 - ' in � •ioo s zu�o'x- � III N O O - cN�o iN<oi oo� N II n >< >e ¢ L Y Y ti X V F- a �O �O N C oa?c so< Wow li w w a H 3 c 3 d i J J W II N m o u rn z o< d' a s 0 X ti C v 0 w OD J 3 LL w o+ mu ~ a X W Lo N a O O w .•� zz�- uou� - Y Y O _ 06 w X 3 O d' N zmz6N-a ma w o O n L 41 N - ac ¢ ti II N Y Y r N d w z Z n v o o X III N a cc a �D M N +-� 7� N N M w w w 3 - 3 to N w 4k Z*�k J J r'^ Baa o a < a m a Ln o v o LO X 3 O m ^ X N N _ F•--1 GL_ N N N to w Ot Lr) 3 J X X X O W - a Q Q• �u Q m n C) 5 O f C� 7 0 0 N J O S E �D 3 COD 3, ~ Q 5 mwm Vo o a, N W' u'� OO W J i i CD �-•� F- N� x 2 3 a w w 3 C O J .� U V -• Z Q- W a O O aLL) U V W • F- m N � F•- m !n C) co OD 0) C a O W l n M N d N N m 3 Cn U') Ol ^ W Ln n O m N m I z Q co O H m _ x Z W W Z v W !- 3 p O N W < a U W LZ' D D S N U- 7: O Li W W LL W Q Ln N Ln Ln Ln N O d d d d J O O H J � N O O O O O O . z Q � � o rt W O O L1") O tI) ,--i N !t O tr r♦ Lo z O c0 o v U O c O O O -J O J U 2 U U U U O d G J H �-- I- tT) m O N - D 3 Z 3 i 2 NI i z J N II O \?:e�G tt•l�r, �i(,P LU i w00 (7y� J N 11,4 f Q J � O U JLP x N .-. a w w Ln 3 CC p 3 N z Z "I 3 D p to N M ^- O M F-• o 0 3 H f N NofIn << F- o x P O LO L] N Q O 3 3 un N - � N O U N oo-uoz v.m > oN_ o O C '�"� ='ux is mo mo=os« . x x oftLO LO _ O F- 3 3 uozW iom<o�o= _ N N - o <=< WI�- N x Ul K We zoo N _ < � • p - io<� L N O �o N W K V =p0 6 o N C� Z m z — Ln • c m n w ae C to � w Z Z F- K N N M 4J a w z > W 8� vim) In ✓CL V) N N N CL x x x d J CV J } 00 G C F- Q W.. tY C a0 0 0 00 N 00 00 0" O a O \ - LL li I Cl) N d N N rn 3 00 LO z ' � Ol r` W Lf'7 n O m N m N II d H Q 00 La z S Z M W W Z O In W Q O' U Cl d' ck� D C) 2 N LL Ln - N Y O W LL LL LL LL C Q N N N N N J N d d d CL d 'l = O O O O O 00 O o O LO O LO CSJ� r O N O z CD 2 J a F Q D Q Z x C:) O) w W J J J J J Li = w Z LL ~ C', a O = CL m F- m m C] N I] 3 Q O Z c7 N Q Z z w O O .Z- _ S w 2' J N Ln H /� 1��P� ~ to � ¢ N = ISI �.•LU C CI V) 00cc - r gir O W n ^ �~ Q J LP O �'LLJ Cr Q f�I J F- lY Q X - CO �•��L] p �J LO ww LO ^ N w w N 3 3 V) z z - Ln U- V) Ln LO � r F- 3 {- G7 J Ln i•..00 W o m F L. V w Ln o w = o W w W On O V w C w tr X X O - O /- N O_ N 0. L is - o X Nr =O d < - LOLO 3 Nt = r-+ a--L 3 C Cno c ~or LO >< c NLr) 3 O o< 3 > - - _ O ion >< = -- z 3 N x 3 W p r w O 00 O J 2 d III 3 =Wosr O LY y - • Ln tD W i - N u m o <J m m CL cli O ¢i W W x V X 3 C' L J J F- O OD .-I w wan ww F- v o =� - J � p ism i« �•+o<¢..�m-- CL O O co W J Nj O CO O O F- O J N W O O J Q U II = O ci W Z N N rn w W W N N 7�'3k zk W O D_ L CL D_ H -Z d CL CL H Q > Ln ¢ N N Ln O V O O Z p•', C) co N Ln 3 O N N N N w 0) '--• Z F1 Gw X X X cm W = Q T ¢ m C) f N r S `.o°j o p N J E E w F- ¢ c5 m v o o O o w • rn xx 3 ¢ w W J U Q ai a w w - ' O O CL U U 2 F'- H- co N F- m H ¢ 0 W co m O p W t^ M N d N N rn 3 '•� x M 41 ^ W LD n O m N m N II N ¢ m N d ct: O r S Z � W W Z 2: m I to W F- 3 Cr O W Q a V W m O O 2 N W c W W Li W W d N N N N N Cl- d a C- d N O O C O O O O O O z N W w V J O O Ln O Ln N z L z x N � •r � O „y � V c.7 � O Q Z °t 0 J O O J JLL U ¢ I- C Q U U U U O O d m m 1-- 0, -m (n 3 Z Ln o 0 o z a 00 w 7Pt - J : NJ L4 L : w a o I N H J LO co d` m M: LeJ Cel eU a III `r Cl) QJ p > n v _ w 3 3 3 CD Z ¢ Z O JO 0 0 >< O � Of V O M CD Q W Cl- m _ x cn 3 II y ECD N O D J d' N O p = w a x - 3 c7 O O 7 2 X: III0 z o c U z x x o u o N .J+ N W N X X - _ d I-- m W O d N aoowV) z W- I-- I- m 3 - MLO III III L =a - >< 3 a y L 'N i xaoa o d �u y >< III OL v =PKos LID LnLl r X 3 3 V) N C7 L Z 0 •• _ > o CD =. ........ LC) s��o J J 2 Ln X ' z x O L w I- O ¢ 3 3 oz Va ios - v w o III LO � N W O ~.. O >< C Z m K X n o v O3 H M >< O W N i w ~ 0 U O3 - _<oe- p -- d z w III ¢ N W J X a O m X O W N Cl- C:, J M vii Mi p o ¢ v 3 x u Nr 3 ti c 3 V N : y O - O N O w �' O N N v III Ln ~ N M .-r M F N N pp �kN �3 O J O m — > prmn R Lil C ]w z z F_ >< _ > < daa - ¢ n � ¢ x Z p^a O N N N 3 H N w N N X x x x 00 E 2Q 3 _T - N N N b a 0 H d O J �V J 3 d i Z N O O NF 0 O O t0 F Q C C z � m I W'© 0 o w v w I- d x f O. x = 3 3 C � U V x V p W N W CI J ¢ a + O O a H N �' 2 W x H 3 '-- m •• c7 ¢ O F- ¢ = o v 71 CD 3no v w 39 0� �{ �---- 9 , 6 Z 29 ' 8 " nna n nin G re Building Supplies of Jacksonville Incorporated TRUSS PLANT St.Augustine a 1 Job Number (s Customer U-�-4 L Job Descr. Job Location L01 A O Designer F3z)'-,> Date Q 2--Z-14 3 Revisions Pitch 5 ` Overhang 2�( Tails Cut Bearing Size 3 Z Seat Plates Yes / No Base Plate Ht . IE!)—(— Loading 4y 7 3%a O.C.Spacing Wind Speed [ NOTICE ! ! l - WE WILL NOT ACCEPT BACKCHARGES UNLESS PRIOR ARRANGEMENTS HAVE BEEN MADE CU Ln 1. DO NOT CUT OR ALTER TRUSSES. 2. VERIFY ALL SPANS AND AMOUNTS, AS TRUSSES WILL BE BUILT IN STRICT ACCORDANCE WITH THIS LAYOUT. 3. APPROVED BY: PRICE: (+Sa lesTax) DATE: JOB ADDRESS: THDS26 MSH422 V� BEACH AjLA oFF�cE Heavy Duty Face Atljus sa 's s; BU D,NG MHanger Cunt Style Hanger o � Fasteners He a Oa r' tle)150 nailsFastener=_ ,.hist: 112)100x1-1/2'na11s MJC ist: 141eager: 1 141 n 7�0 na.ls THD28 THDH28-2 Heavy Duty Face Meavy Duty Face Mount style Hanger Mount Style Hanger 29 ' 8 _ Fastene1h rs Fasteners Healer: (36) 166 nails Heaaer: 12e1i6a nails Jost Ifo) 166 nails Joist 1161100x1-1/2'na�ls ITOe nai]ea) "II'lu1011 s[1eu,2/I-t><DOT 1911 .7s,or .T. P. 10;1 .]s�or 6lteu 09;192) .daOeaH slceu Dg; 1961 :JaDeaH s.iaual6ej sJaualsej ul a F . 11 9 , 6 Z Ja6u.H .1475 1—H :gej A;10 11-H J26UeH al4l$ 7un1q aoej A]n0 An02H Z—BZHOHI BZOH1 617eu DN W :7s,or t[[.u,2;1-1101[12;1 at;or s[;eu DOS 1221 :Ja1906 18 s1�eu Dg; ;1 .Je,-H tJ:u:ltej sJau:7sej I Jafi ueH 2[x.75 7UnoH lllUlH aoe, A. AneaH geJ75 d[ge75n1D7 EEVHSH 9ESOH1 I :SS3UOOV e0r W 31V0 (xelsat eS+) 33I dd 1.6 O3AOUddV 'E I '1n0,1V-1 SIHl 1 HlIM 33NVOE033V 13IH1S I NI liIne 30 -1-lIM S3SSnui SV 'SINnOWV ONV SNVdS 71V 1,3I83A 'E 'S3SSndl u31nV HO in3 ION 00 'b 30VW N336 3AVH R.) SIN3W39NVHdV dOIdd SSI-INn S39HVH3N3Ve Id333V ION IlIM 3M ii 13IlON v✓ oo / PaadS purM �-j BUT 3edS'3'0 oZl�� L 6utpeon Z—]— ';H a;eid aseg o / saX sa;eld 4eaS I Z azis 6U Jeae ;n3 sI?eI Z 6ueUJanO Z uo;?d suo> stAad Q 2J ZZ & aje0 — Jau6TsaO a r v-.a7p J o� uol;c?oo-1 qon 5a� '�cubioq Josao qon i s? ,word 7 Jawolsn3 I c�) .;agwnN qof auczsn5nV']S 1NV-ld SSndl ❑ajeJ0dJ000? 8111AU05)I7er y0 'v V salT ddnS 6u> pl ;ng SUlUU2WW9 e ; 6 z -- T 2' i I i I LD Lo � I I TL FT 3 11 11 F 2 11 11 I BE M A OVE Tn o LL TT 10" J ItT T- LL m f 29 ' 8 " //// /nCITY OF Office of Building Official 2 REQUEST FOR INSPECTION ILI� " ) Date Pe mit No. Time M Received P Job Addre Locality ,p Owner's Name Contractor UILD NCRETE ELECTRICAL PLUMBING MECHANICAL Framing r Footing ❑ Rough Wiring ❑ Rough ❑ Air Cond. & ❑ Re Roofing ❑ Slab ❑ Temp Pole ❑ Top Out ❑ Heating Insulation _ Lintel ❑ Final ❑ Sewer Fire rFab Place El PreREADY FOR INSPECTION Mon. Tues. Wed. Thurs. Friday PM• — / A.M. Inspection ade P.M. Final Inspection Inspector Certificate of Occupancy ❑ Date 17334 PSR-3844 DEPARTMENT OF BUILDING CITY OF ATLANTIC BEACH --- PERMIT INFORMATION ----- LOCATION INFORMATION --emit Number: 17334 . 1ress , 79 SHELL STREET Permit Type:BUILDING ATLANTIC BEACH , FLORIDA-32233- lass LORIDA32233lass of Work:NEW LEGAL DESCRIPTION lonttr . Type:WOOD FRAME Slock :7 Lot *. 8 Twp: C. -roposed Use: SINGLE FAMILY Section: 0 Subd- Rng: 0 Dwelling~ : ngs - 0 subdivision:OCEAN GROVE UNIT NO, 1 Est , Value: 0 . 00 improv . Cost : 180 , 446. 00 Total Fees : 3 . 320 . 98 Amount Paid' 3, 320 . 98 rate P a i d i,loqj-19/-'19 9 8 'IE - 11�11ME PEP, PLAN"' HSF 2412 RADON 880/C . S . CHG 2 42 3 W APPLICATION FEES ---------- --- CW!qER INFORMATION ---- 7--7-- 1 ,099 . 50 Line: DOANE ERM 17 7 ATER IMPACT FEE 510 .00 EWER Ar: 1 �-Iq SEMINOLE ROAD 'WE 'EWER IMPACTvFEE hf"T,�,FEE 3? 250 01' I.NTIC SEA FLORIDA 249-7 0ATER P' ADON alk -1 ': 4 CONT R*ft ADON CAB 5% 0 . 2 _,� 1 NFQRMAT 1 C)N 325 .00 ine: j & L 'APITAL IMPROVE , - 0 .00 ,3r, R, SUITE EWER TAP 445-20 35 .00 ' " FLORIDR ROSE CONNECTION AtKSONVILW 'EC H IMPACT FEE 0 .0 0 �:ic CRCQ292777 Exp : 10'. 9 "'pe: .)NST . SURCHAR(-,E S NOTES: NOTICE - INSPECTIONS MUST BE REQUESTED AT LEAST 24 HOURS PRIOR TO INSPECTION BUILDING MATERIAL, RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE, AND MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER "FAILURE TO COMPLY WITH THE MECHANICS' LIEN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS." ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW. ki i<ccea - ­I Total paypent ATLANTIC BEACH BUILDING DEPARTMENT By: CITY OF ATLANTIC BEACH DEPARTMENT OF BUILDING 800 SEMINOLE ROAD-ATLANTIC BEACH,FL 32233-TEL: 2475826-FAX 247-5877 PERMIT INFORMATION LOCATION INFORMATION Permit Number: 21609 Address: 79 SHELL STREET Permit Type: BUILDING ATLANTIC BEACH, FLORIDA 32233 Class of Work: ADDITION Township: 0 Range: 0 Book: Proposed Use: SINGLE FAMILY Lot(s):8 Block: 7 Section:0 Square Feet: Subdivision: OCEAN GROVE UNIT NO. 1 Est. Value: Parcel Number: Improv. Cost: OWNER INFORMATION,.—.------------- Date NFORMATION ._._ ________Date Issued: 3/15/2010 Name: DOUGLAS S. DOANE Total Fees: 25.00 Address: 1679 SEMINOLE ROAD Amount Paid: 25.00 ATLANTIC BEACH, FLORIDA 32233 Date Paid: 3/15/2001 Phone: (904)249-7050 Work Desc: Addition Drive Way CONTRACTORS -APPLICATION FEES PROPERTY OWNER PERMIT 25.00 inspections Rqquired.. — SLAB NOTICE- INSPECTIONS MUST BE REQUESTED AT LEAST 24 HOURS PRIOR TO INSPECTION BUILDING MATERIAL, RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE,AND MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER "FAILURE TO COMPLY WITH THE CONSTRUCTION LIEN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS" ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW. Q 7 AT NTIC B CH BUILDING DEPT. Date: 3/15/81 el Receipt: 2i5 9818888321888 CITY OF ATLANTIC BEACH CONSTRUCTION PERMIT WITHIN CITY RIGHTS OF WAY AND EASEMENTS DATE '�� ( �� PERMIT NO. 7ISSUED BY THE CITY JOB ADDRESS �� ' VALUATION $ PERMITTEE PERMM-EE ADDRESS C) S S TELEPHONE NO. 642-3/30 REQUESTING PERMISSION FROM THE CITY OF ATLANTIC BEACH TO CONSTRUCT /.._/�1 VE Wl�'h LOCATIONS: (REFERENCE TO CROSS-STREET) I . APPLICANT DECLARES THAT PRIOR TO FILING THIS APPLICATION HE HAS ASCERTAINED THE LOCATION OF ALL • EXISTING UTILITIES, BOTH AERIAL AND UNDERGROUND AND THE ACCURATE LOCATIONS ARE SHOWN ON THE SKETCHES. A LETTER OF NOTIFICATION WAS MAILED TO THE FOLLOWING UTILITIES/MUNICIPALITIES: JACKSONVILLE ELECTRIC AUTHORITY YES ( ) NO ( ) DATE: BELL SOUTH TELEPHONE COMPANY YES ( ) NO ( ) DATE: FERRELL GAS YES ( ) NO ( ) DATE: MEDIA ONE CABLE TV YES ( ) NO ( ) DATE: 2. WHENEVER NECESSARY FOR THE CONSTRUCTION, REPAIR, IMPROVEMENT, MAINTENANCE, SAFE AND EFFICIENT OPERATION, ALTERATION OR RELOCATION OF ALL, OR ANY PORTION OF SAID STREET OR EASEMENT AS DETERMINED BY THE DIRECTOR OF PUBLIC WORKS, ANY OR ALL OF SAID POLES, WIRES, PIPES, CABLES OR OTHER FACILITIES AND APPURTENANCES AUTHORIZED HEREUNDER, SHALL BE IMMEDIATELY REMOVED FROM SAID STREET OR EASEMENT OR RESET OR RELOCATED HEREON AS REQUIRED BY THE DIRECTOR OF PUBLIC WORKS, AND AT THE EXPENSE OF THE PERMITTEE UNLESS REIMBURSEMENT IS AUTHORIZED. 3. ALL WORK SHALL MEET C17Y OF ATLANTIC BEACH OR FLORIDA DEPARTMENT OF TRANSPIRATION STANDARDS AND BE PERFORMED UNDER THE SUPERVISION OF 0 ri 3A ///a r'C7 (CONTRAC�T/OR'S PROJECT SUPERINTENDENT) LOCATED AT 6'5//- "/ - ( 5 , . FS. TELEPHONE NO. 2�I t- /� /2 4. ALL MATERIALS AND EQUIPMENT SHALL BE SUBJECT TO INSPECTION BY THE DIRECTOR OF PUBLIC WORKS OR HIS DESIGNEE. S. ALL CITY PROPERTY SHALL BE RESTORED TO ITS ORIGINAL CONDITION AS FAR AS PRACTICAL, IN KEEPING WITH CITY SPECIFICATIONS AND THE MANNER SATISFACTORY TO THE CITY. 6. A SKETCH OR PLANS COVERING DETAILS OF THIS INSTALLATION SHALL BE MADE A PART OF THIS PERMIT. 7. THIS PERMITTEE SHALL COMMENCE ACTUAL CONSTRUCTION IN GOOD FAITH WITHIN j DAYS FROM THE DAY OF SAID PERMIT APPROVAL AND SHALL BE COMPLETED WITHIN DAYS. IF THE BEGINNING DATE IS MORE THAN 60 DAYS FROM DATE OF PERMIT APPROVAL, THEN PERMITTEE MUST REVIEW THE PERMIT WITH THE DIRECTOR OF PUBLIC WORKS TO MAKE SURE NO CHANGES HAVE OCCURRED IN THE AREA THAT WOULD AFFECT THE PERMITTED CONSTRUCTION. 8, IT IS UNDERSTOOD AND AGREED THAT THE RIGHTS AND PRIVILEGES HEREIN SET OUT ARE GRANTED ONLY TO THE EXTENT OF THE CITY'S RIGHT, TITLE AND INTEREST IN THE LAND TO BE ENTERED UPON AND USED BY THE HOLDER, AND THE HOLDER WILL, AT ALL TIMES, ASSUME ALL RISK OF AND INDEMNIFY, DEFEND, AND SAVE HARMLESS THE CITY OF ATLANTIC BEACH FROM AND AGAINST ANY AND ALL LOSS, DAMAGE, AND COST OF EXPENSES ARISING IN ANY MANNER OF THE EXERCISE OR ATTEMPTED EXERCISES BY THE HOLDER OF THE AFORESAID RIGHTS AND PRIVILEGES. 9. THE DIRECTOR OF PUBLIC WORKS SHALL BE NOTIFIED TWENTY-FOUR (24) HOURS PRIOR TO STARTING WORK 5? �� AND AGAIN IMMEDIATELY UPON COMPLETION. -OR-UvAn FN--# Ij5C0-x'7'7- S7- 296-0- o COVAT I F LitYrat- '� k'p— SUBMITTED BY: / `�aANt (PLACE CORPORATE SEAL IF APPLJCABI SWORN TO AND SUBSCRIBED BE RE ME THIS DAY O -pi;) ZO0I MAUREEN ICING Notary PubUC-State of Rakso NOTARY PU IC My Commission Expires Mcr 31,2002 Commission#CC720781 MAP SH13WING BOUNDARY SURVEY 11F; LOT 8, BLOCK 7, OCEAN GROVE, UNIT NO. 1, AS RECORDED IN PLAT BOOK 15, PAGE 82 OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA.. Lor; &ocK7 I LOT 2, dLOCK 7 ecl?c. Pd110' Found Ilron,01* 293 " -)4e �7146 00 k I • + %L A C 01 3 0 GF_ 2111" 0 IC Ike Q) Pop. N\ Al -214 0 go qs' 0 011! ki 289 5O. 00, e lound 1'1rvnR1;pe "SNE L t 6 r19 157 40'/?/CHT Of'-WA V NOTES Z-q,-nd NO BUILDING RESTRICTION LINE BY PLAT, BUT THERE MAY BE 6RL Depo IcG Build;l)q Aslrtc-lldn One RESTRICTION LINES OR EASEMENTS THAT AFFECT THIS k DenoI05 Oak rfre PROPERTY BY ZONING OR RECORDED IN THE PUBLIC RECORDS 10 Denotes Palm rrm OF THIS COUNTY THAT ARE NOT SHOWN ON THIS SURVEY. THIS PROPERTY LIES IN FLOOD ZONE "X" BY FLOOD MAPS REVISED 4/17/1989, COMMUNITY PANEL NO. 120075 0001 D. BUILDING RESTRICTION LINES SHOWN HEREON ARE BY ZONING PER CLIENT REQUEST. I—AA111 Phone �+ r LICENSED (904)221-7231 GUT �OY INSURED w TREE SERVICE l' PRESERVATION •TRIMMING • REMOVAL SPECIALIZING IN HAZARDOUS JOBS 24 HOUR STORM SERVICE 402 North 18th Street • Jacksonville Beach, FL 32250 Date 5 Name _ Address . ell' City J q61 - :gib St. Zip AMOUNT DESCRIPTION DUE r . J._ '46Y - r Total Payment due is due upon completion of the job. Sub Total TAX TOTAL Cust.Signature DUE 2 Lkj /CITY--O//F /3 PGcA" Office of Building Official REQUEST FOR INSPECTION Permit No. Date Time P.M. Received / CC—/(p Locality Job Ydress A ^ Ow er's Contra ✓w Na pWMBING MECHANICAL CONC ELECTRICAL in b e BUILDI ❑ Rough � Heating Framing & ❑ Rough Wiring Framing Footg Temp Pole ❑ Top Out eating ❑ Re Roofing 101 Final Pre Fab Sla ❑ Sewer ❑ Fire Place Insulation El Lint READY FOR INSPECTION A.M. (2 Tues. Wed. Thurs. Friday on. A Inspection Made Final Inspection ❑ Inspector Certificate-f �n=O Date TO: P€Il F :43 1 5 MIN. RETURN RAU of commencement RHONE#- Of a To whom It may concern: `zr P., »✓oZ 13(t O The undersigned hereby lalorme You that Improvements will be tried* to cc rialn real property, and in t0 eaeoCOM with at.NT, 713.13 Of the Florida 84tuha, the ruin Inforntatlon ts elated in thy NOTICE 0 OF COIgc�NCEJd]CNT. C Description of PtoPertY -73--- + LVA_ No(Zr£ --uNcr_.��1p m ------------------------------------—-------------------------------------------------_—------------ �^ -------------------------------------------- General description of lmproveman4 -------------------'----------------------------------------------------- owAar --5-c-qlq- _A!_ MSA- 0-N!L----C�-'•�'- =�W&'t= ?------------------------------------ au Addr. Ownees U%W*st In alts Of the improvement Fee,BlmPle Title holder (if other than owner) ---------- da Name Addrep _ - _ _••------•--•---- ------------ Convector QP!CI�L _✓ NCC O '�adrKr --Q -�--- ---- �`---!Q✓E------ fan Otb Surety (i!any) V1 tT __ �L © Q►.?I rp��--------------- --- -- re Address 44K�_ Yl! ��� —�� — ----tea ---- Ant %L of bond S Z Name and.ddre�A'o(xf y pe n making a loan for the construction of the improvements. RR Name yr- 1�! ---- --- -- _1 Address -- ------------- - - -- _._----- -- - CS2 lime served• Of person within the State of Florida. other than himself, dccignated by owner upon whom notittc or other documents be N.mer_--------L-A-------------------'--,-----------------------•--------------------------------• Address _______________ _ _ _ Ls addition to himself, owner designates the following person to ncalve • copy of the Llenor's Notice as ✓' / [ 7 Ib), Tlorlda Statu a. (Fill in at Owner's option). •ants* YJA_�---W=---��. 2n`E_ Address - ]C�1�_ _ TM Ie e1ACL/Oa a[COwOea'e Ue[ONIY -------_- -�'-_-_'-r-_. ZIP is�ea 101 K►ow" F11ed t Retot'ded ------- ------ 01/23/2001 12:03:40 DN IIN FULLER LVA MTYIT CUT I .s TRUST FUIm 1 1.00 1 Slr� n to and su scribed baflnf me this e { 1.00 _ epi FEEpp�p -------- p I1� , _ day _ 7 -41 t E ej Notary public f(•ate,Cao ZV,,,6zc Lt G C54 — L433 ���- Sep-30-98 12 : 55P P .02 FLOODPLAIN DEVELOPMENT INFORMATION VdCK 7 ,, 6 c e ,v\ C"rj✓� Location:: ?? 1 Type of Development: ,v\r„ Q V K-I's C eMC 'e Flood Zone: X i Required Lowest Floor Elevation: If building is located within a flood hazard zone, a survey must be made AFTER THE SLAB HAS BEEN POURED, certifying that the LOWEST FLOOR ELEVATION is equal to or above the base flood elevation established for that zone. No final inspection will be made and no certificate of occupancy will be issued until the survey is on file with the Building Department. COMMENTS: Applicant Acknowledgment: I understand that the issuance of this permit is contingent upon the above information being correct and that the plans and supporting data have been or shall provided as required. I agree to comply with all applicable provisions of Ordinance N -7-11 and all other laws or ordinances affecting the proposed depm t. Date�� �l Applicant's Signat Department Use: Required Lowest Floor Elevation . As Built Lowest Floor Elevation Survey Filed with Building Departmenty Building`IY6partment Represe tative .00 KAP SHOWING BOUNDARY SURVEY OF LOT 8 BLOCK 2- AS SHOWN ON MAP OF AS RECORDED IN PLAT BOOK PAGES 8 2 OF THE PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA CERTIFIED FOR: no v c L.A /moo c— - AM e-/?- i C--AI/ /010 A Li� �zl P/ 7A L • / 0A/21 0 LL_ A T o /Z n/ti v5 7- [ � /S , Fv ID c . Z U_ 00 x u n. N o.A v z � 0 � n N J � • . � Z • ST Y. sLl A/14 7_ .0'5) N U z 3. d m N N k 0 (v N ECEIV MAR 5 1999 � m City of Atlantic Beach E LL T. Building and Zoning Lk THE PROPERTY SHOWN HEREON APPEARS TO LIE WITHIN FLOOD HAZARD ZONE X AS SCALED FROM FLOOD INSURANCE RATE MAP / FOR THE CI TY OF '' r-,4 y , FLORIDA, DA TED - -8 9 AND — 1 ...,..n rrw –•n v •un n� �Inr nnAICTITYI= A 1'-00TIC"/`AT1nAI /1C CAIJC- DATE : PRE-SERVICE DIVISION JACKSONVILLE ELECTRIC AUTHORITY 23:.3 WEST DUVAL STREET JACKSONVILLE, FLORIDA 32202 THE FOLLOWING FINAL INSPECTIONS ) HAVE BEEN MADE AND ARE SATISFACTORY : ---------------------------------- ------ ------------------------------------------------- ------ ' -------------------------------------------------- ------ ' ------------------------------------------------- ------ ------------------------------------------------- Enclosed are the blue copies of the permits. SINCERELY, BUILDING INSPECTION DIVISION cc : FILE CITY OF > �t�tcstic Se4d - 800 SEMINOLE ROAD ATLANTIC BEACH. FLORIDA 32233-5445 -- TELEPHONE(904) 247-5800 F.A.Y(904)247-5805 NOTICE TO: Water Department FROM: Building Department DATE: � Please be advised that the final building inspection has been completed on each of the following addresses and construction water is no longer needed: Permit Number Address 17 -3 LI),x Sincerely. Building Department a s 3 c m w C 3 � m o m CD m ^703 mo m ID 3 o n o o L CL cr CD a Q` 11 El o /v N \ c rCn�n (� c m o CD m Q= Z m m 171 �o F-, El C D N m g n� m � o \ CD 0y3 °c m TI W n --a s 0 w Z 20 ' a O U) n w 3 D °_ m r ° Cl) O o ❑❑❑ m `a Z CD 0 3 (n o m 1 a 0 T c f� � - �+ r z O ry N N r= n Z 0 W w m � Z m C) INI o_ c \( n T ❑❑❑ �V 0 W c fl I w 01 T - (p m -n v o = a D CD � A D �D r CITY OF ATLANTIC BEACH DEPARTMENT OF BUILDING i 800 SEMINOLE ROAD-ATLANTIC BEACH, FL 32233-TEL: 247-5826-FAX: 247-5877 PERMIT INFORMATION I _ LOCATION INFORMATION Permit Number: 17883 i Address: 79 SHELL STREET Permit Type: REMODELING ATLANTIC BEACH, FLORIDA 32233 Class of Work: ALTERATION Township: 0 Range: 0 Book: Proposed Use: SINGLE FAMILY Lot(s):8 Block: 7 Section: 0 Square Feet: Subdivision: OCEAN GROVE UNIT NO. 1 Parcel Number: Est. Value: � -- ---- -_ _ � Date Issued: 3/09/1999 ' '-OWNER INFORMATION_ _' Im rov. Cost: I -_ Name: DOUGLAS S. DOANE Total Fees: 1,865.00 Address: 1679 SEMINOLE ROAD Amount Paid: 1,865.00 ATLANTIC BEACH, FLORIDA 32233 Date Paid: 3/08/1999 Phone: (904)249-7050 Work Desc: ADDENDUM TO BUILDING PERMIT NO.17334 ADDING MOTHER IN LAW SUITE CONTRACTOR(S) APPLICATION FEES J & L HOMES, INC. WATER IMPACT FEE 290.00 SEWER IMPACT FEE 1,250.00 CAPITAL IMPROVE. 325.00 i I j Inspections Required _ -- i i NOTICE- INSPECTIONS MUST BE REQUESTED AT LEA-ST-24-HOURS-PRIOR TO INSPECTION BUILDING MATERIAL. RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE. AND MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER "FAILURE TO COMPLY WITH THE CONSTRUCTION LIEN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS" ISSUED ACCORDING TO APPROVED PLANS VVHICH ARE PhNI^C'I OF THIS PERMIT AND SUBJECT TO REVOCA T ION FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW. Operator: YENDY Date: 3/89/99 81 Receipt: 8839724 - L Total Payeent $1865.88 ATLANTIC BEACH ILDING PT. I CITY OF ��tla.ctic �eacl - �eie�uda 800 SEMINOLE ROAD ATLANTIC BEACH,FLORIDA 32233-5445 TELEPHONE(904) 247-5800 FAX(904)247-5805 Date �00Q, L64S ©SNE Dear Property Owner : The costs to connect your building to the City sewer and/or water system are as follows : Sewer Tap - Labor and Materials to tap into _ sewer main $ Q Water Tap - Labor and Materials to tap into water main $ Water Meter .- Cost of Meter $ - —" Cross Connection Inspection - Inspection by Public Works to ensure backflow O prevention $ Sewer Impact Fees - Funds future expansion of the sewer plant 00 Water Impact Fee - Funds future expansion o ,0 0 of the water plant $ capital Improvement - Funds for improvements , expansion or replacement to S= 0 0 water system $ TOTAL COSTS $ 0' S If you have any questions concerning these charges please call the building department at 247-5826 . Sincerely , ,g. o, C Don C . For Building Official DCF/pah a - �" s � 16 ✓� - 14, 1 S 2 �Q ti v ~ IV - :� C31 m i v9 � � X n J �I- S Z Q` .� c6 Y.. _ v 0 cb 0 CITY OF ATLANTIC BEACH Fixture Unit Worksheet for Water Impact Fee FIXTURE UNITS ARE ESTABLISHED AS THE MEASUREMENT OF WATER DEMAND FOR EACH WATER FIXTURE UNIT INSTALLED AND CONNECTED TO THE CITY WATER SYSTEM. THE WATER SUPPLY CHARGE IS HEREBY FIXED AT TWENTY DOLLARS PER FIXTURE UNIT CONNECTED TO THE CITY WATER SYSTEM. BATHROOM GROUP CONSISTING OF WATER CLOSET. LAVATORY 6 BATHSERVICE -SINK TRAP STAND TUB OR SHOWER STALL (6) WATER CLSET (8) WATER CLOSET, TANK OPERATED (4) ___i_VALVE OPERATED (8) BATHTUB/SHOWER (2) — URINAL WALL LIP (4) SHOWER GROUP PER HEAD (3) FLOOR DRAIN (1) SHOWER STALL DOMESTIC (2) LAUNDRY TRAY (2) i LAVATORY (1) COMBINATION SINK AND TRAY (3) _WASHING MACHINE (3) POT. SCULLERY SINK (4) DISHWASHER (2) WASH SINK EACH SET OF (_KITCHEN SINK (2) FAUCETS (2) DENTAL LAVATORY (1) KITCHEN SINK WITH WASTE DENTAL UNIT OR CUSPIDOR 1 GRINDER (3) ( ) ,_BIDET (�) URINAL STALL, WASHOUT (4) FLUSHING RIM SINK (8) COMBINATION SINK AND TRAY WITH FOOD DISPOS. (4) _,URINAL, PEDESTAL. SYPHON JET BLOWOUT (2) DRINKING FOUNTAIN (1/2) LAVATORY, BARBER/BEAUTY ' SHOP (2) ICE MAKER (1/2) SURGEONS SINK (3) LAVATORY, SURGEONS (2) JACUZZI (2) URINAL STALL. WASHOUT (4) TOTAL FIXTURE UNITS $20.00 EACH a 6 . 0 b JOB IPtFORHATZON ioo MAP SHO MNG BOUNDARY SURVEY OF LOT 8 BLOCK 7 AS SHOWN ON MAP OF AS RECORDED IN PLAT BOOK_ PAGES 8 2 OF THE PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA CER77FIE0 FOR: /�)ot,/QL4-5 /D o,4 4-- 4MC-izic-An/ Al AC,e- P/T4L 1*Don/,4ua0� 0 Al OII— C_L. 7- L,F- n/S . v /� G . Z SO- CXR" u K 1i7c N pQ v W 0 J z S'T'Y. X� r, Ul AIA W L U m Er cn I N N N 1 Q � m � LL S' T. THE PROPERTY SHOWN HEREON APPEARS TO LIE WITHIN FLOOD HAZARD ZONE X AS SCALED FROM FLOOD INSURANCE RATE MAP / FOR THE CITY OF N/3 E/�L / _ , FLORIDA, DA TED 4- 1 —8 9 AND r� nrrn..r Al A nnrrorrcv n►u v Aero nncc AlnT I-rWCTlTniTc d rFPT79rArnm nF SAA.IF J & L HOMES, INC. RESIDENTIAL CONTRACTOR (Lic . # CR CO29 445-26 State Road 13 Suite 347 Jacksonville, Fl 32259 904-699-9725 C/ly �4R e�;; of-It c�X99 40 MARCH 8, 1999 a/ij� X011 tt 9 TO PERMIT # 17334 d�aZoeeac ADDENDUM 11) h 79 SHELL STREET - DOANE RESIDENCE 17e After the Doane residence was permitted, the slab installed, and the framing nearly completed, Mr. Douglas Doane (Owner) received a cash gift from a family member to be used to install a pool and to rough in certain plumbing, electrical, and partition walls in the storage area (603 square feet) above the garage. The space above the garage had already been permitted for air conditioning. The pool was permitted separately. A floor plan of the additional work performed on the area above the garage is included herewith. The additional work includes : Plumbing: supply and drain lines were stubbed out for a future bath (tub, toilet, & lavatory) , supply and drain lines were stubbed out for a future sink and washer, and a supply line was stubbed out for a refrigerator ice maker. Electrical : receptacles and switches were installed in each partitioned room, including GFI circuitry for the future bath and kitchenette, lighting was blanked off according to code. Circuits were installed for a stove, dishwasher, and refrigerator. Partitioning: framing for interior partitioning was completed and is identified on the included drawing as the darkened partitions . Drywall was hung on these interior partitions but has not been finished. All additional work completed on this area was completed according to Code . Mr. Doane wishes to report the above described improvements installed in the storage area to the City of Atlantic Beach Building Department, and he wishes to pay any additional permi and impact fees deemed to be due at this time . /( / T"" CONTRACTOR:: OWNER: /, CONT License # CR 92 e L4 `- �.a'.�C- A c� X 'r `` � �s G S a- � a CiA CN �� G S S vr: r. mac--- AN VN as `� `•. -t'?' '', � ��,�' � 7p ci ' `^ co - i r-n <7 4' 9,.,o 'E C`1 © z��� °0 0 nm IL S LA o , CLS / e s r � � t a � 1 Pn O loo MAP SHO WING BOUNDARY SURVEY OF LOT 8 BLOCK AS SHOWN ON MAP OF AS RECORDED IN PLAT BOOKS PAGES 8 Z OF THE PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA CER77F/ED FOR: novCjL4.5 !>o C_a o 1'TQ L ; 1:)o,1,4uao D A/A ive L L AT- n/tj V5 7 L,E G . z 50 cx). u76 '/ f--5M'7 N oA v = Sz 0 z STY. X� ? � ogvIAIa 3 s N cr 5z Cr m 0 ^I , cr- um .r /IELL S' T. L� IZ THE PROPERTY SHOWN HEREON APPEARS TO LIE WITHIN FLOOD HAZARD ZONE X AS SCALED FROM FLOOD INSURANCE RATE MAP / FOR THE CITY OF r , FLORIDA, DATED 4 - -8 9 AND ----.-. _ --... �..... ..... .. ...,, --l— n., TIn err n r'cOnc/'e nnM nF' cd AJF CITY OF ATLANTIC BEACH DEPARTMENT OF BUILDING 800 Seminole Road -Atlantic Beach, FL 32233 - Tel: 247-5826 - Fax: 247-5877 ELECTRICAL PERMIT PERMIT INFORMATION LOCATIONINFORMATION Permit Number: 17839 Address: 79 SHELL STREET Permit Type: ELECTRICAL ATLANTIC BEACH, FLORIDA 32233 Class of Work: POOL Township: 0 Range: 0 Book: Proposed Use: SINGLE FAMILY Lot(s):8 Block: 7 Section: 0 Square Feet: Subdivision: OCEAN GROVE UNIT NO. 1 Est. Value: Parcel Number: "Improv. Cost: OWNER INFORMATION' Date Issued: 2/25/1999 Name: DOUGLAS S. DOANE Total Fees: 35.00 Address: 1679 SEMINOLE ROAD Amount Paid: ATLANTIC BEACH, FLORIDA 32233 Date Paid: 2/25/1999 Phone: (904)249-7050 Work Desc: WIRE FOR SWIMMING POOL CONTRACTORS APPLICATION FEES JAGUAR ELECTRIC, INC. PERMIT 35.00 Inspections Required ROUGH ELECTRIC FINAL ELECTRIC NOTICE - INSPECTIONS MUST BE REQUESTED AT LEAST 24 HOURS PRIOR TO INSPECTION BUILDING MATERIAL, RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE, AND MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER "FAILURE TO COMPLY WITH THE CONSTRUCTION LIEN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS" ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW. -�7k ATLANTIC BEACH BUILDI EPT. CITY OF ATLANTIC BEACH, FLORIDA APProvod by APPLICATION FOR ELECTRICAL. PERMIT TO THE CHIEF ELECTRICAL INSPECTOR: DATE:-_J_ IMPORTANT NOTICE: IN CONSIDERATION OF PERMIT GIVEN FOR DOING THE WORK AS DESCRIBED IN THE FOLLOWING, WE HEREBY AGREE TO PERFORM SAID WORK IN ACCORDANCE WITH THE ATTACHED PLANS AND SPECIFICATIONS, WHICH ARE A PART HEREOF, AND IN ACCORDANCE WITH THE ELECTRICAL REGULATIONS, CODES AND CITY OF ATLANTIC BEACH ORDINANCES. ELECTRICAL FIRM: gCrup►r CAAASTER ELECTRICIAN SIGNATURE JOURNEYMAN NAME__D©�- —ADDRESS:—/ y/ RFD__BOX BLDG.SIZE BETWEEN: RES. ( ) APT. ( 1 comm. ( 1 PUBLIC l 1 INDUS. ( ) NEW (V OLD ( 1 REW. ( I ADDITION ( ) TRAILER ( 1 TEMP. ( 1 SIGNS ( ) SQ. FT. SERVICE: NEW ( 1 INCREASE ( 1 REPAIR ( ) FEE CONDUCTOR SIZE AMPS COPPER l 1 ALUM. ( ) SWITCH OR BREAKER AMPS PH W VOLT RACEWAY EXIST.SERV.SIZE V AMPS PH W VOLT C-,061&- RACEWAY FEEDERS NO. SIZE NO. SIZE NO. SIZE LIGHTING OUTLETS CONCEALED OPEN TOTAL RECEPTACLES CONCEALED OPEN TOTAL 0.30 AMPS. 31-100 AMPS. SWITCHES INCANDESCENT FLUORESCENT&M.V. FIXED 0.100 AMPS. OVER APPLIANCES BELL TRANSF. AIR H.P. RATING H.P. RATING CONDITIONING COMP.MOTOR OTHER MOTORS AMPS CEIL HEAT: KW-HEAT 0.1OVER MOTORS H.P. I VOLTAGE PHS NO. 1 H.P. VOLTAGE PHS i x-30 1 A � � MISCELLANEOUS i7r' `m . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (�Ertificttt� of Mccupttuc (fitu of Atlantic 1=4 — Noriba De.partII ut of TAuilbing Jnspection This Certificate issued pursuant to the requirements of Section 103.8 of the Southern Standard Building Code certifying that at the time of issuance this structure was in compliance with the various ordinances regulating building construction or use For the following. Use Classification Single Family Residence Bldg. Permit No. 17334 Group w.frame Type Construction sf Fire District Atlantic Beach Owner of Building Douglas Doane Address 79 Shell Street Buil5iiqq Address LocalitA l an i B a h, By: DON C, FORD Building Official Date: 3 C7 POST IN A CONSPICUOUS PLACE BUILDING, PLANNING AND ZONING INSPECTION DEPARTMENT CITY OFATLANTIC BEACH, FLORIDA CER TIFIC4TE OF OCCUPANCY WORKSHEET Date Requested: Building Contractor: �� 4 Building Permit Number: / 733>1 Address : Legal Description: � �lo�fc 7, Improvements to the above described property have been completed in accordance with the terms of the permit and is certified to be ready for occupancy as n Lowest Floor Elevation: -S �a •a � required as built BEFORE ISSUING CERTIFICATE OF OCCUPANCY THE FOLLOWING MUST BE COMPLETE DEPARTMENT DATE /NOTIFIED DATE APPROVED Fire Public Works 2- Planning Planning q Building PRICE QUOTE APPLICATION FOR WATER AND/OR SEWER TAP APPLICANT NAME ��(,���(,� �S' l)OC i? MAILING ADDRESS PHONE NUMBER �/� -70 DATE /,D_ /V 9 SERVICE REQUESTED SERVICE LOCATION /v� bfiLtg �« l/ DATE SET TO PUBLIC WORKS - /V-9e ' DATE RETURNED TO BUILDING DEPARTMENT PUBLIC WORKS DEPARTMENT PRICE QUOTE RESPONSE WATER: SEWER: OTHER: PRICE QUOTE PREPARED BY: Signature - Title DATE NOTIFIED OWNER HP OfficeJet Fax Log Report Personal Printer/Fax/Copier Oct-14-98 09:34 AM Identification Result Pages Tyne Date Time Duration Diagnostic 5872 OK 01 Sent Oct-14 09:33A 00:00:26 002586030022 7.4.0 CITY OF ATLANTIC BEACH Fixture Unit Worksheet for Water Impacc Fee FIXTURE UNITS ARE ESTABLISHED AS THE MEASUREMENT OF WATER DEIMAND FOR EAC2 WATER FIXTURE UNIT INSTALLED AND CONNECTED TO THE CITY WATER SYSTEM. THE, WATER SUPPLY CHARGE IS HEREBY FIXED AT T,;ENTY DOLLARS PER FIXTURE UNIT CONNECTED TO THE CITY WATER SYSTEM. BATHROOM GROUP CONSISTING OF 0 SERVICE .SINK TRAP STAND WATER CLOSET. LAVATORY 6 BATH (8) TUB OR SHOWER STALL (6) / 2 2WATER CLOSET WATER CLOSET, TANK OPERATED (4) y VALVE OPERATED (8) d BATHTUB/SHOWER (2) URINAL WALL LIP (4) SHOVE.Q GROUP PER HEAD (3) FLOOR DRAIN (1) f SHOWE7t STALL DOMESTIC (2) _LAUNDRY TRAY (2) LAVATORY (1) _COMBINATION SINK AND TRAY (3) WASHING ?MACHINE (3) _POT. SCULLERY SINK (4) __L _D ISHWASHER (2) Z —WASH SINK EACH SET OF /� ICITCHE:i SINK (2) V FAUCETS (2) DENTAL LAVATORY (1) [I7C2m SINK WITH WASTE 3 DENTAL UNIT OR CUSPIDOR (1) GRINDER (3) BIDET (2) URINAL STALL, WASHOUT (4) _FLUSHING RIM SINK (8) COe2INATION SINK AND TRAY WITH i FOOD DISPOS. (4) URINAL, PEDESTAL, SYPHCH JET DRINKING FOUNTAIN (1/2) BLOWOUT (2) LAVATORY, BARBER/BEAUTY _ ICE MAKER (1/2) 1 SHOP (2) SURGEONS SINK (3) Q LAVATORY, SURGEONS (2) JACUZZI (2) 0 URINAL STALL, WASHOUT (4) TOTAL FIXTURE UNITS ` J $20.00 EACH $ 5-10- 00 .TOB INFORMATION MAP SHOWING SPECIFIC PURPOSE SURVEY OF: LOT 8, BLOCK 7, OCEAN GROVE, UNIT NO. 1, AS RECORDED IN PLAT BOOK 15, PAGE 82 OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA. LOT 1 , BLOCK 7 LOT 2, BLOCK 7 50.00' - - - -UTILITY-EA- - - - - - FOUND 1" IP 6' SEMENT BY PLATS r W- - - - - - NO ID - - `''- - - - - - ppe �0 901 0� �O 0 4• G 12"P 98-K 20' BRL Q ®8"K Oo E)9"K Of 0 Ly Q 012"CH RRY 08" LOT 7, BLOCK 7 m I ®7"K J 0i 5"K O ® 15"K Z = 1 0"K10"P O LJ C �5"K I G 10"K 8 m O O r o (DO7"K U-) viZ _j o Lr; 10"K 811P® 0 w 0 m pG 9"K 'n W 10"K G®8 K 11"K e ®6"K "K 8"K 9"K 8"K 8"K _0] ( 5"K 4"K F9 4"K ® G 9'.K 8"K 90>� 10"K 5"K ��p0 ® moo•. G12"K -G 7"K FOUND 1" IP 9„K® 50.00' 11"P NO ID SHELL STREET 40' RIGHT-OF-WAY (SHELL & DIRT ROAD) NOTES: LEGEND 1.) THE SPECIFIC PURPOSE OF THIS SURVEY IS TO SHOW TREES BRL DENOTES BUILDING RESTRICTION LINE ACCORDING TO CITY OF ATLANTIC BEACH SPECIFICATIONS. K DENOTES OAK TREE 2-) NO BUILDING RESTRICTION LINE BY PLAT, BUT THERE P DENOTES PALM TREE MAY BE RESTRICTION LINES OR EASEMENTS THAT - - 8 DENOTES TREES (SEE DESCRIPTION FOR SIZE & TYPE) AFFECT THIS PROPERTY BY ZONING OR RECORDED O DENOTES FOUND 1" IRON PIPE ' IN THE PUBLIC RECORDS OF THIS COUNTY THAT ARE ID DENOTES IDENTIFICATION NOT SHOWN ON THIS SURVEY. IP DENOTES IRON PIPE 3.) THIS PROPERTY LIES IN FLOOD ZONE "X” BY FLOOD MAPS REVISED 4/17/1989, COMMUNITY PANEL NUMBER 120075 000iD. 4.) BUILDING RESTRICTION LINES SHOWN HEREON ARE BY ZONING PER CLIENT REQUEST. MAP SHUWING BOUNDARY SURVEY ❑Es LOT 8, BLOCK 7, OCEAN GROVE, UNIT N0, I, AS RECORDED IN PLAT BOOK 15, PAGE 82 OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA.. Lor/ BLOCK 7 I LOT 2, BLOCK 7 woad Fence —— — — 1° Fence FOUnd/"/moon Pipc 6'Uti/i/y Easen>Pnf.4✓ _(n/o/4) a.5' A —— _ 4' m—L ED--k 8�� .. � �.a' B9'ae'oo"CWoao FP •ce 9O'i Z'ao' S.s' j/G'Waodfe�xr rT o _ _ i Ov, 5 1998 - ToL City of Atla c Beach Building an Zoning 0 O � � � � O o ltj C � i J! OAl c 1 L4j � �L 9o•i2'00" B9.4B'00' 0.3' 50- 00' �Found/"//On Pipe (No/O) SAIEL C S TREE T' GT OP ♦�•Fre f/yd/anf /.:/�E�� i� viRr.Poav� NOTES C NO BUILDING RESTRICTION LINE BY PLAT, BUT THERE MAY BE 0JU��G RESTRICTION LINES OR EASEMENTS THAT AFFECT THIS PROPERTY BY ZONING OR RECORDED IN THE PUBLIC RECORDS OF THIS COUNTY THAT ARE NOT SHOWN ON THIS SURVEY. THIS PROPERTY LIES IN FLOOD ZONE "X" BY FLOOD MAPS REVISED 4/17/1989, COMMUNITY PANEL NO. 120075 0001 D. CERTIFIED TO FORM 60OA-93 FLORIDA ENERGY EFFICIENCY CODL FOR BUILDING CONSTRUCTION Residential Whole Building Performance Method A Project Name: 2423 Builder: J & L Homes Permitting Office-4-rzA147-lC a5Ac Address: City, State: Atlantic Beach, FL Permit Number: /733 14 2 Jurisdiction Number: Owner: Doane �l Climate Zone: North F4. New construction or existing New _ 1 I. Cooling systems Single family a. Central Unit a:48 Btu" Single family or multi-family g Y - SI 1 Number of units,if multi-family 1 Is this a worst case? No - b. N/A I 5. Conditioned floor area(111) 2423 ft: - c. N/A 6. Glass area&type - a. Clear-single pane 0.0 ft= 31 b. Clear-double pane 9.0 ft2 _ 12. Heating systems 0.0 ft, - a. Central Heat Pump Unit Cap:48.0 kBtu/hr c. Tint/other SC-single pane HSPF:7.30 d.Tint/other SC-double pane 0.0 ft, - b. N/A 7. Floor types a. Slab-On-Grade Edge Insulation R=0.0, 162.0(p)ft - b. Raised Wood Adjacent R=19.0,667.Oft2 - c. N/A - c. N/A - 8. Wall types 13. Hot water systems R=13.0,2184.0 ft' a. Electric Resistance Cap:50.0 gallons _ a. Frame,Wood,Exterior - EF:0.90 b. Frame,Wood,Adjacent R=13.0,416.0 ft' - c. N/A - b. N/A d.N/A - e. N/A - 14. Hot water conservation credits - (HR-Heat recovery,solar 9. Ceiling types a. Under Attic R=30.0, 1617.0 ft' _ DHP-Dedicated heat pump) Under Attic R=19.0,77.0 ft' _ 15. Infiltration practice(1,2,or 3) b. c. Under N/A _ 16. HVAC credits - (CF-Ceiling fan, 10. Ducts a. Sup:Uncond. Ret:Cond. Sup.R=6.0, 1.0 ft - CV-Cross ventilation, b.N/A - HF-Whole house fan, RB-Attic radiant barrier, MZ-C-Multizone cooling, MZ-H-Multizone heating) Total as-built points: 36772.00 C Glass/Floor Area: 0.13 Total base points: 39266.00 EPI = 93.6 I hereby certify that the plans and specifications covered Review of the plans and t�F by this calculation are in compliance with the Florida specifications covered by this �� �C Energy Code. �R ENGINEERS, INC. calculation indicates compliance A with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: this building will be inspected for h � compliance with Section 553.908 1� I hereby certify that this buildi in complianc the o d i Statutes. COD Florida Energy Code. 1 OWNER/AG NT- BUILDING OFFICIAL: DATE: * y�q DATE: /(=D / FORM 60OA-93 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , Atlantic Beach, FL, PERMIT #: BASE AS-BUILT GLASS TYPES .15 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOr. Poin .15 2423.0 65.80 23915.0 Double, Clear S 2.0 6.7 81.0 66.20 0 3. 0 Double, Clear S 2.0 6.0 24.0 66.20 0.71 11 Double, Clear S 1.0 12.0 60.0 66.20 0.94 37' Double, Clear W 1.3 11.0 4.0 79.70 0.95 3u_ o Double, Clear W 1.3 7.0 4.0 79.70 0.91 291 1 Double, Clear W 1.3 2.0 4.0 79.70 0.65 206.2 Double, Clear W 1.3 4.0 16.0 79.70 0.82 1042.8 Double, Clear W 1.3 3.0 6.0 79.70 C 156.9 Double, Clear W 1.3 13.0 10.0 79.70 c Double, Clear N 1.0 12.0 40.0 38.30 C.56 466.e Double, Clear E 1.3 3.0 6.0 79.70 0.75 356.9 Double, Clear E 1.3 5.0 40.0 79.70 0.86 2748.8 Double, Clear E 5.0 6.0 24.0 79.70 0.57 '.09 •.2 As-Built Total: 319.0 1 WALL TYPES Area X BSPM = Points Type R-Value Area X Sr M = ,;oint5 Adajcent 416.0 0.7 291.2 Frame, Wood, Exterior 13.0 2184.0 1.50 3276.0 Exterior 2184.0 0.90 1965.6 Frame, Wood, Adjacent 13.0 416.0 0.60 249.6 Base Total: 2600.0 2256.8 As-Built Total: 2600.0 3525.6 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 18.5 2.40 44.4 Exterior Wood 38.8 6.10 236.4 Exterior 38.8 6.10 236.4 Adjacent Wood 18.5 2.40 4 :.4 Base Total: 57.3 280.8 As-Built Total: 57.3 280.8 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Under Attic 1549.0 0.60 929.4 Under Attic 30.0 1617.0 0.60 970.2 Under Attic 19.0 77.0 1.10 8 Base Total: 1549.0 929.4 As-Built Total: 1694.0 1 4.9 FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Poing Slab 162.0(p) -37.0 -5994.0 Slab-On-Grade Edge Insulation 0.0 162.0(p) -41.20 -, 74.4 Raised 667.0 -3.99 -2661.3 Raised Wood,Adjacent 19.0 667.0 0.41: 26'� Base Total: -8655.3 As-Built Total: •6407.6 FORM 60OA-93 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , Atlantic Beach, FL, PERMIT#: BASE AS-BUILT INFILTRATION Area X BSPM = Points Type Area X SPM = Points 2423.0 8.00 19384.0 Practice#2 2423.0 8.00 19384.0 Summer Base Points: 38110.7 Summer As-Built Points: 35284.7 Total Summer X System = Cooling Total X Cap X Duct X System X Credit Co, j Points Multiplier Points Component Ratio Multiplier Multiplier Multipi.er PcI;;;;, , 38110.7 0.37 14100.9 35284.7 1.00 1.07 0.28 1.00 10738.0 FORM 60OA-93 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , Atlantic Beach, FL, PERMIT #: BASE AS-BUILT GLASS TYPES .15 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF = Points .15 2423.0 -10.60 -3852.6 Double, Clear S 2.0 6.7 81.0 -28.40 0.84 -1932.3 Double, Clear S 2.0 6.0 24.0 -28.40 0.81 -549.8 Double, Clear S 1.0 12.0 60.0 -28.40 0.97 -165k i Double, Clear W 1.3 11.0 4.0 -9.20 0.85 -31.2 Double, Clear W 1.3 7.0 4.0 -9.20 0.75 -27.7 Double, Clear W 1.3 2.0 4.0 -9.20 0.01 -0.2 Double, Clear W 1.3 4.0 16.0 -9.20 0.51 -74.7 Double, Clear W 1.3 3.0 6.0 -9.20 0.32 -17.8 Double,Clear W 1.3 13.0 10.0 -9.20 0.87 -80.2 Double, Clear N 1.0 12.0 40.0 7.30 1.06 310.3 Double, Clear E 1.3 3.0 6.0 -9.20 0.32 _11 Double, Clear E 1.3 5.0 40.0 -9.20 0.63 -230.2 Double, Clear E 5.0 6.0 24.0 -9.20 -0.23 50.8 As-Built Total: 319.0 -4257.5 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adajcent 416.0 3.6 1497.6 Frame, Wood, Exterior 13.0 2184.0 3.40 7425.6 Exterior 2184.0 2.20 4804.8 Frame,Wood, Adjacent 13.0 416.0 3.30 1372.8 Base Total: 2600.0 6302.4 As-Built Total: 2600.0 8798.4 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 18.5 11.50 212.8 Exterior Wood 38.8 12.30 476.6 Exterior 38.8 12.30 476.6 Adjacent Wood 18.5 11.50 212.8 Base Total: 57.3 689.4 As-Built Total: 57.3 689.4 CEILING TYPESArea X BWPM = Points Type R-Value Area X WPM = Points Under Attic 1549.0 1.20 1858.8 Under Attic 30.0 1617.0 1.20 1940.4 Under Attic 19.0 77.0 2.00 154.0 Base Total: 1549.0 1858.8 As-Built Total: 1694.0 2094.4 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 162.0(p) 8.9 1441.8 Slab-On-Grade Edge Insulation 0.0 162.0(p) 18.80 3045.6 Raised 667.0 0.96 640.3 Raised Wood,Adjacent 19.0 667.0 2.20 1467.4 Base Total: 2082.1 As-Built Total: 4513.0 FORM 60OA-93 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , Atlantic Beach, FL, PERMIT#: BASE AS-BUILT INFILTRATION Area X BWPM = Points Type Area X WPM = Points 2423.0 7.40 17930.2 Practice#2 2423.0 7.40 17930.2 Winter Base Points: 25010.3 Winter As-Built Points: 29767.9 Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points 25010.3 0.55 13755.7 29767.9 1.00 1.07 0.47 1.00 14878.6 FORM 600A-93 WATER HEATING AND EPI SUMMARY Residential Whole Building Performance Method A - Details ADDRESS: , Atlantic Beach, FL, PERMIT#: BASE AS-BUILT WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 3 3803.00 11409.0 50.0 0.90 3 1.00 3718.49 1.00 11155.5 As-Built Total: 11155.5 EPI SUMMARY BASE AS-BUILT Cooling + Heating + Hot Water = Total Cooling + Heating + Hot Water = Total Points Points Points Points Points Points Points Points 14100.9 13755.7 11409.0 39265.6 10738.0 14878.6 11155.5 36772.1 EPI : 93.6] y��OF THE ST 9r�D�t+ WE ENERGY PERFORMANCE LEVEL DISPLAY CAnD For detailed information Doa ie of the EPI rating number or for any ITEM listed, Atlantic Beach FL ask your Builder for DCA Form 60OA-93 or Form 60OB-93 EPI= 93.6 0 10 20 30 40 50 60 70 60 90 100 excellent good acceptable The maximum allowable EPI is 100. The lower the EPI the more efficient the home. . . i Ir ITEM HOME VALUE Low Efficiency High Efficiency SINGL CLR DBL TINT WINDOWS................................................ Double Clear INSULATION............................................ R-10 R-30 Ceiling R-Value............................. 30.0 R-0 R-7 Wall R-Value.............................. 13.0 R-0 R-19 Floor R-Value.............................. 19.0 I AIR CONDITIONER................................... 10.0 SEER ti:.0 SEER...................................................... 12.00 9.7 EER 16.0 �I I HEATING SYSTEM................................... 6.8 HSPF 12.0 Electric HSPF........................................ 7.30 WATER HEATER..................................... 0.88 0.96 Electric EF...................................... 0.90 0.54 0.90 GasEF...................................... N/A 1.0 5.0 SolarEF...................................... N/A OTHER FEATURES................................. I I certify that these ener y saving feature re uired for the Florida Energy Code have en installed in this house. 7- �l�1 /3 B Ilder 7t� �- L '3 �-�— Signature. /Col—te: d- Address. � -� City/Zip: y Florida Energy Code for Building construction-1993 Florida Department of Community Affairs FL-EPL CARD 93 RIGHT-J LOAD AND EQUIPMENT SUMMARY File name: 2423 .BLD 10-1-98 For: J & L Homes 445-26 SR 13 Jacksonville FL 32259 (904 ) 287-0049/699-9725 By: Air Engineers, Inc. 10947 Beach Blvd. Jacksonville FL 32246 ( 904 ) 641-2333 Doane Residence Job # : Plan 2423 Sq. Ft. Wthr : Jacksonville AP FL Zone : Entire House WINTER DESIGN CONDITIONS SUMMER DESIGN CONDITIONS Outside db: 32 Deg F Outside db: 94 Deg F Inside db: 70 Deg F Inside db: 75 Deg F Design TD: 38 Deg F Design TD: 19 Deg F Daily Range M Rel . Hum. : 50 % Grains Water 49 gr HEATING SUMMARY SENSIBLE COOLING EQUIP LOAD SIZING Bldg. Heat Loss 38562 Btuh Structure 28393 Btuh Ventilation Air 100 CFM Ventilation 2090 Btuh Vent Air Loss 4180 Btuh Design Temp. Swing 3 . 0 Deg F Design Heat Load 42742 Btuh Use Mfg. Data n Rate/Swing Mult. 1 . 00 INFILTRATION Total Sens Equip Load 30483 Btuh Method Simplified LATENT COOLING EQUIP LOAD SIZING Construction Quality Average Fireplaces 0 Internal Gains 1840 Btuh Ventilation 3332 Btuh HEATING COOLING Infiltration 4854 Btuh Area ( sq. ft. ) 2423 2423 Tot Latent Equip Load 10026 Btuh Volume (cu- ft- ) 21807 21807 Air Changes/Hour 0 . 7 0 . 4 Total Equip Load 40509 Btuh Equivalent CFM 255 146 HEATING EQUIPMENT SUMMARY COOLING EQUIPMENT SUMMARY Make Lennox Make Lennox Model CB29M51 Model 12HPB48 Type Air Handler Type Heat Pump Efficiency / HSPF 7 . 3 COP/EER/SEER 12 . 0 Heating Input 0 Btuh Sensible Cooling 0 Btuh Heating Output 0 Btuh Latent Cooling 0 Btuh Heating Temp Rise 0 Deg F Total Cooling 0 Btuh Actual Heating Fan 1359 CFM Actual Cooling Fan 1359 CFM Htg Air Flow Factor 0 . 035 CFM/Btuh Clg Air Flow Factor 0 . 048 CFM/Btuh Space Thermostat Load Sens Heat Ratio 81 MANUAL J: 7th Ed. . RIGHT-J: V2 . 12 SN5144 Printout certified by ACCA to meet all requirements of Manual Form J RIGHT-J CALCULATION PROCEDURES A,B, C,D Job # : Plan 2423 Sq. Ft . File name: 2423 .BLD 10-1-98 Zone : Entire House Procedure A - Winter Infiltration HTM Calculation* ----------------------------------------------------------- 1 . Winter Infiltration CFM 0 . 7 AC/HR x 21807 Cu.Ft. x 0 . 0167 = 255 CFM 2 . Winter Infiltration Btuh 1 . 1 x 255 CFM x 38 Winter TD = 10656 Btuh 3 . Winter Infiltration HTM 10656 Btuh 376 Total Window = 28 . 3 HTM & Door Area ---------------- -------------------------------------------- Procedure B - Summer Infiltration HTM Calculation* ----------------------------------------------------- 1 . Summer Infiltration CFM 0 . 4 AC/HR x 21807 Cu.Ft. x 0 . 0167 = 146 CFM 2 . Summer Infiltration Btuh 1 . 1 x 146 CFM x 19 Summer TD = 3045 Btuh 3 . Summer Infiltration HTM 3045 Btuh 376 Total Window = 8 . 1 HTM & Door Area - --------------------------------------------------------------------- Procedure C - Latent Infiltration Gain ---------------------------------------------- ------------ - 0 . 68 x 49 gr.diff . x 146 CFM ----4854--Btuh ----------------------------------------------- Procedure D - Equipment Sizing Loads -------------------------------------------------- 1 . Sensible Sizing Load Sensible Ventilation Load 1 . 1 x 100 Vent .CFM x 19 Summer TD = 2090 Btuh Sensible Load for Structure (Line 19 ) + 28393 Btuh Sum of Ventilation and Structure Loads = 30483 Btuh Rating and Temperature Swing Multiplier x 1 . 00 RSM Equipment Sizing Load - Sensible + 30483 Btuh 2 . Latent Sizing Load Latent Ventilation Load 0 . 68 x 100 Vent.CFM x 49 gr.diff . = 3332 Btuh Internal Loads = 230 x 8 No. People + 1840 Btuh Infiltration Load From Procedure C + 4854 Btuh Equipment Sizing Load - Latent = 10026 Btuh --- *Construction Quality is : a No. of Fireplaces is : 0 MANUAL J: 7th Ed. RIGHT-J: V2 . 12 SN5144 Printout certified by ACCA to meet all requirements of Manual Form J 2423 .BLD Job# Plan 2423 Sq. Ft . Zone:Entire House 10-1-98 ----- MANUAL J: 7th Ed. ---- RIGHT-J: V2 . 12 --- SN5144 --- Page 1 ---- 1 Name of Room Entire House Whole House 2 Running Ft. Exposed Wall 162 . 0 Ft . 162 . 0 Ft. 3 Room Dimensions, Ft. 2423 . x 1 . 0 Ft. 4 Ceiings,Ft I Condit. Option 9 . 0 d 9 . 0 1heat/cool ------------------------------- Area---------- ETYPE XPOSIIRE--- 1 INO. 1HtgH � Clg I Lengthl HtgBtih Arga 1 gBtih Clg Len th Ht Clg ---------------------------------------------------- 5 Gross a 12C 3 . 4 2 . 0 2184 **** **** 2184 **** **** Exposed b 13C 1 . 4 1 . 3 416 **** **** 416 **** **** Walls and c 0 . 0 0 . 0 0 **** **** 0 **** **** Partitions d 0 . 0 0 . 0 0 **** **** 0 **** **** e 0 . 0 0 . 0 0 **** **** 0 **** **** f 0 . 0 0 . 0 0 **** **** 0 **** **** -------------------6 Windows a 3C 27 . 6 ** 319 8788 319 8788 & Glass b 3C 27 . 6 ** 0 0 **** 0 0 **** Doors Htg. c 7I 33 . 2 ** 0 0 **** 0 0 **** d 0 . 0 ** 0 0 **** 0 0 **** e 0 . 0 ** 0 0 **** 0 0 **** f 0 . 0 ** 0 0 **** 0 0 **** 7 Windows North 23 . 0 300 6891 300 6891 ----------------- **** **** & Glass NE&NW 0 . 0 0 **** 0 0 **** 0 Doors Clg. E&W 72 . 0 19 **** 1395 19 **** 1395 SE&SW 0 . 0 0 **** 0 0 **** 0 South 0 . 0 0 **** 0 0 **** 0 Horz 0 . 0 0 **** 0 0 **** 0 81 Othr doors 17 . 5 10 . 4 18 323 192 181 3231 192 1aj10D b10D117 . 5110 . 4 391 6781 403 39 678 403 9 Net a 12C 3 . 4 2 . 0 1826 6246 3714 1826 6246 3714 Exposed b 13C 1 . 4 1 . 3 398 537 501 398 537 501 Walls and c 0 . 0 0 . 0 0 0 0 0 0 0 Partitions d 0 . 0 0 . 0 0 0 0 0 0 0 e 0 . 0 0 . 0 0 0 0 0 0 0 f 0 . 0 0 . 0 0 0 0 0 0 0 --- -------------------- -------------------- 10 Ceilings a 16G 1 . 3 1 . 4 1617 2028 2295 1617 2028 2295 b 16D 2 . 0 2 . 3 77 155 175 77 155 175 c 18D 1 . 7 1 . 9 0 0 0 0 0 0 11 Floors jaj :22A30 . 8 0 . 0 162 4986 0 162 4986 0 b 19D 1 . 0 0 . 0 667 659 0 667 659 0 c 0 . 0 0 . 0 0 0 0 0 0 0 121 Infiltration a 128 . 31 8 . 1 3761 106561 3045 3761 106561 3045 ------------------------------- ------------------- **** **** 13 Subtot Btuh Loss=6+8 . . +11+12 35056 **** **** 14 Duct Btuh Loss 10% 3506 **** 10� 35056 3506 **** **** **** **** **** 15 Total Btuh Loss = 13+14 38562 38562 ------ ------------------ 16 Int . Gains : People @ 300 8 **** 2400 8 **** 2400 Appl . @ 1200 4 **** 4800 4 **** 4800 17 Subtot RSH Gain=7+8 . .+12+16 **** **** 25812 **** **** 25812 18 Duct Btuh Gain 10% **** 2581 10% **** 2581 19 Total RSH Gain=( 17+18) *PLF 1 . 00 **** 28393 1 . 00 **** 28393 20 CFM Air Required I **** 1359 1359 **** 1359 1359- --- Printout certified by ACCA to meet all requirements of Manual Form J - MANUAL J: 7th Ed. RIGHT-J: V2 . 12 SN5144 RIGHT-J WINDOW DATA Job # : Plan 2423 Sq. Ft. File name: 2423 .BLD 10-1-98 W S D W G L S S 0 N A S 0 0 W c W S N K I A L 0 T H V G N H V V H H N H D y R L A W R A H L G c R R G T A A W L Z E M D G Z L 0 X y T M R R Whole House a n s a c n n n y 2 90 1 . 0 1 . 0 0 . 0 1 . 0 38 . 0 165 . 165 . a n e a c n n n y 2 90 1 . 0 1 . 0 0 . 0 1 . 0 72 . 0 70 . 0 58 . 1 a n n a c n n n y 2 90 1 . 0 1 . 0 0 . 0 1 . 0 23 . 0 40 . 0 0 . 0 a n w a c n n n y 2 90 1 . 0 1 . 0 0 . 0 1 . 0 72 . 0 44 . 0 36 . 5 J and L HOMES - LOT 8, OCEAN GROVE, ATLANTIC BEACH - DOANE Wind Load Structural Calculations per 1606 SBC '97 Robert C. Pollard, Professional Engineer 128 Martin Road, St. Augustine, Florida 32086 Telephone: (904) 797-3709 Fax: (904) 794-1155 PE 25644 in FL, PE 21834 in GA Length O.H. in ft. 2.00 CRI KJ sq. ft. 4.00 Rake O.H. in ft. 1.50 q= .00256V2(H/33)" CRI uplift 242 Wind Speed 110 CR2 GE sq. ft. 3.00 Weight of Roof? 10 Velocity P = 27.3 CR2 uplift 182 Pitch 5 Factor 1 28.2 CR3 area Mean Roof Ht. 21.09 Factor 2 56.3 CR3 uplift 0 Area 3026 Factor 3 89.1 Truss @ ft. o.c. 2 Factor 4 178.3 Contractor J&L HOMES, INC. Address 445-26 STATE ROAD 13, ST. 347 City JACKSONVILLE Zip 32259 Phone# 287-0049 MP 699-9725 Model #/name Job Address City vs Building Dept. CITY OF ATLANTIC BEACH Legal Descrp. LOT 8, OCEAN GROVE &\ Residence for DOANE 0� J and L HOMES - LOT 8, OCEAN GROVE, ATLANTIC BEACH - DOANE LATERAL SHEAR LOADS I SUBJECT LOAD SHEAR Misc. Total Length Subj. Shear Shear Engineer's WALL WALL WALL 1.2=H. ie D1 Shear Subj. Wall Wall Wall Preliminary ID# Length MULTIPLIER 1.3=G. ie D2 Load Wall Opng. Length (plf) Calculations SWI 20.3 17.00 1.3 6123 29.7 18.7 11.0 557 2673 2 EW1 29.7 17.00 1.3 8936 50.0 7.7 42.3 211 -1311 1 SW2 29.7 17.00 1.3 8936 29.7 11.0 18.7 479 2049 1 EW2 29.7 17.00 1.3 8936 50.0 9.7 40.3 222 -1227 1 SW3 52.0 5.00 1.3 4606 29.7 8.0 21.7 213 -80 1 EW3 29.7 5.00 1.3 2628 52.0 10.0 42.0 63 -2619 1 SW4 52.0 5.00 1.3 4606 29.7 13.3 16.3 282 475 1 EW4 29.7 5.00 1.3 2628 52.0 9.0 43.0 61 -2631 1 ISW1 50.0 17.00 1.3 15059 29.7 4.0 25.7 587 2913 2 R LOADS I UPLIFT SHEA O SUBJECT Uplift (-) WALL (_) Walls Req. Uplift Anchor WALL (plf) UPLIFT SHEAR T&B(396plf) T&B(1172plf) ID# CAPACITY HCDP/HC520 TP#X/TP#X SWI 141 200 -59 EW 1 507 200 307 1.29 3.82 SW2 141 200 -59 EW2 507 200 307 1.29 3.82 SW3 141 200 -59 EW3 507 200 307 1.29 3.82 SW4 141 200 -59 EW4 507 200 307 1.29 3.82 ISW1 0 200 -200 J and L HOMES - LOT 8, OCEAN GROVE, ATLANTIC BEACH - DOANE CONNECTOR CHART See attached chart or catalog for nailing ADDITIONAL MEMBER LOAD MFG. LOCATIONS UANTITY-PART# A2-3 1014 1 Hughes I TP 2-RT1218 HEADERS LOAD MFG. LOCATIONS UANTITY-PART# ADDITIONAL H1 1128 Hughes A C See Chart H2 500 Hughes A C See Chart H3 750 Hughes A C See Chart H4 10681 Hughes AIC ISee Chart H5 15211 Hughes I A C See Chart GABLE FRAME LOAD MFG. LOCATION QUANTITY-PART# A1GF 20911 Hughes I TP 2-RT20 BALLOON FRAME W/2X4 A4GF 20911 Hughes I TP 2-RT20 Fiberglass-asphalt shingles on 15# Felt over min 7/16" OSB w clips 24" o.c. nailed 6"o.c. edge 12" ox field w 8d nails Pre-Engineered trusses (RS nails recommended) 0 24" o.c. hurricane strap @ each truss Bafflels Galy Drip edge / 1/2" Gyp. Drywall wall I Vented Soffit Insulation with Vapor Barrier per code Studs @ 16" o.c. - - Size, Grade & Sheathing per Engr. Chart. STRAPS ---► 3/4" Plywood subfloor glued and nailed RT48112 w. 18-10dnsilc HUGHES CONNECTORS - NAIL AND BOLT REQUIREMENTS WOOD CLIPS AND STRAPS Max. Uplift Max. Uplift Nails/Bolts I.D. s.y,p SPF Required HC 325 260 8 - 8d HCDP 515 412 8 - 8d HC520 515 412 17 - 8d HC10 1475 1180 18 - 10d RT818 582 466 6 - 10d RT1018 776 621 8 - 10d RT1418 970 776 10 - 10d RT1618 1164 931 12 - 10d RT16112 1164 931 12 - 10d RT18112 1358 1086 14 - 10d RT20112 1552 1242 16 - 10d RT22112 1746 1397 18 - 10d RT48112 1746 1397 18 - 10d HMSTA 12 605 484 10 - 10d HMSTA 15 726 581 12 - 10d HMSTA 18 847 678 14 - 10d HMSTA 21 968 774 16 - 10d HMSTA 24 1089 871 18 - 10d HMSTA 30 1342 1074 22 - 10d WVVUC 4256 3405 4 - 3/4" bolts 1465 1172 10 - 10d TP'X 2155 1724 10 - 16d MASONRY TO WOOD CONNECTORS TA12 935 748 5 - 10d TA14 1002 802 6 - 10d TA16 1002 802 6 - 10d TA18 1169 935 7 - 10d TA20 1503 1202 9 - 10d HTA16 1312 1050 8 - 10d HTA20 2000 1600 14 - 10d WAM 4135 3308 24 - 16d & 3/4" dia bolt WAL50 1800 1440 10 - 16d & 1/2" dia bolt HD2/5A 3536 2829 2 - 5/8" bolts & 5/8" x 9" A.B. WOOD COLUMN CONNECTORS PA4x4 1515 1212 6 - 16d PA4x6 1765 1412 8 - 16d PA6x6 2020 1616 8 - 16d C044 7250 5800 2 - 5/8" bolts C046 7250 5800 2 - 5/8" bolts C066 7250 5800 2 - 5/8" bolts ! u 111 O 1 U E W O C m C [1 ❑. C U Ifl 3 7 R !L !li 11 1- m S _• �H S i'_Yw o w 1!) > aY ` m vi m u v m v > m v 0 0 ¢ a 0 1- m f/1 CO J 0 ; ^ N a eR I -C� —l� � I OD O cv F'_ cv m uwj I 1A 0 a F— s w m N�- 1 05 _i FORM 100A-93 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Residential Whole Building Performance Method A Project Name: 2423 Builder: J & L Homes Address: Permitting Office: City, State: Atlantic Beach, FL Permit Number: Owner: Doane Jurisdiction Number: Climate Zone: North I. New construction or existing New - 11. Cooling systems Single family a. Central Unit t .p:48. Btu/'-- _ 2. Single family ormulti-family g Y - 3. Number of units,if multi-family 4. is this a worst case? No - b.N/A 5. Conditioned floor area(ft') 2423 ft' - 6. Glass area&type a N/A - a. Clear-single pane 0.0 ft' - 1 b. Clear-double pane 319.0 ft' - 12. Heating systems c. Tint/other SC-single pane 0.0 R -' a. Central Heat Pump Unit Cap:48.0 kl3tu/hr - HSPF:7.30 d. Tint/other SC-double pane 0.0 ft' - - 7. Floor types b. N/A a. Slab-On-Grade Edge Insulation R=0.0, 162.0(p)fl - - b. Raised Wood,Adjacent R=19.0,667.Ofl' - c. N/A c. N/A - 8. Wall types 13. Hot water systems a. Frame,Wood,Exterior R=13.0,2184.0 ft' - a. Electric Resistance Cap:50.0 gallons - b. Frame,Wood,Adjacent R=13.0,416.0 R' - EF:0.90 c. N/A - b.N/A d. N/A - e. N/A - 14. Hot water conservation credits - 9. Ceiling types (HR-Heat recovery,solar a. Under Attic ;R=30.0, 1617.0 R' - DHP-Dedicated heat pump) Under Attic R=19.0,77.0 ft' - 15. Infiltration practice(1,2,or 3) b. Un ' - c. - 16. HVAC credits - 10. Ducts (CF-Ceiling fan, a. Sup:Uncond. Ret:Cond. Sup.R=6.0, 1.0 ft - CV-Cross ventilation, b. N/A - HF-Whole house fan, RB-Attic radiant barrier, MZ-C-Multizone cooling, MZ-H-Multizone heating) Total as-built points: 36772.00 C Glass/Floor Area: 0.13 Total base points: 39266.00 EPI = 93.6 FEnergy ertify that the plans and specifications covered Review of the plan and ✓� culation are in compliance with the Florida specifications ccovered by this calculation indicates compliance �� Code. GINEERS, ING. AIR EN with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: SEP o 0 1998 this building will be inspected for , �L� ~ v the compliance with Section 553.908 f�c �y� I hereby certify that this buildi in compliance Florida Statutes. Florida Energy Code. OWNER/AG NT• BUILDING OFFICIAL: -- DATE: �°� y!q S� DATE: ,,� : 3 FORM 60OA-93 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , Atlantic Beach, FL, PERMIT #: BASE AS-BUILT GLASS TYPES .15 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF = Points .15 2423.0 65.80 23915.0 Double, Clear S 2.0 6.7 81.0 66.20 0.74 3968.0 Double, Clear S 2.0 6.0 24.0 66.20 0.71 112? u Double, Clear S 1.0 12.0 60.0 66.20 0.94 3723.8 Double, Clear W 1.3 11.0 4.0 79.70 0.95 302.1 Double, Clear W 1.3 7.0 4.0 79.70 0.91 291.1 Double, Clear W 1.3 2.0 4.0 79.70 0.65 206.2 Double, Clear W 1.3 4.0 16.0 79.70 0.82 1042.8 Double, Clear W 1.3 3.0 6.0 79.70 0.'/.- 356.9 Double, Clear W 1.3 13.0 10.0 79.70 0.96 76-4-9 Double, Clear N 1.0 12.0 40.0 38.30 0.96 1466.2 Double, Clear E 1.3 3.0 6.0 79.70 0.75 356.9 Double, Clear E 1.3 5.0 40.0 79.70 0.86 2748.8 Double, Clear E 5.0 6.0 24.0 79.70 0.57 1090.2 As-Built Total: 319.0 174 1t1t,) WALL TYPES Area X BSPM = Points Type R-Value Area X Sr M = Points Adajcent 416.0 0.7 291.2 Frame, Wood, Exterior 13.0 2184.0 1.50 3276.0 Exterior 2184.0 0.90 1965.6 Frame, Wood, Adjacent 13.0 416.0 0.60 249.6 Base Total: 2600.0 2256.8 As-Built Total: 2600.0 3525.6 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 18.5 2.40 44.4 Exterior Wood 38.8 6.10 236.4 Exterior 38.8 6.10 236.4 Adjacent Wood 18.5 2.40 44.4 Base Total: 57.3 280.8 As-Built Total: 57.3 280.8 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Under Attic 1549.0 0.60 929.4 Under Attic 30.0 1617.0 0.60 970.2 Under Attic 19.0 77.0 1.10 84-7 Base Total: 1549.0 929.4 As-Built Total: 1694.0 1054.9 FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = -Points Slab 162.0(p) -37.0 -5994.0 Slab-On-Grade Edge Insulation 0.0 162.0(p) -41.20 -6674.4 Raised 667.0 -3.99 -2661.3 Raised Wood, Adjacent 19.0 667.0 0.40 263.3 Base Total: -8655.3 As-Built Total: -6407.6 FORM 60OA-93 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , Atlantic Beach, FL, PERMIT #: BASE AS-BUILT INFILTRATION Area X BSPM = Points Type Area X SPM = Points 2423.0 8.00 19384.0 Practice#2 2423.0 8.00 19384.0 Summer Base Points: 38110.7 Summer As-Built Points: 35284.7 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cool",9 Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points M 38110.7 0.37 14100.9 35284.7 1.00 1.07 0.28 1.00 10738.0 FORM 60OA-93 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , Atlantic Beach, FL, PERMIT #: BASE AS-BUILT GLASS TYPES .15 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF = Points .15 2423.0 -10.60 -3852.6 Double, Clear S 2.0 6.7 81.0 -28.40 0.84 -1932.3 Double, Clear S 2.0 6.0 24.0 -28.40 0.81 -549.8 Double, Clear S 1.0 12.0 60.0 -28.40 0.97 -1656.7 Double, Clear W 1.3 11.0 4.0 -9.20 0.85 -31.2 Double, Clear W 1.3 7.0 4.0 -9.20 0.75 -27.7 Double, Clear W 1.3 2.0 4.0 -9.20 0.01 -0.2 Double, Clear W 1.3 4.0 16.0 -9.20 0.51 -74.7 Double, Clear W 1.3 3.0 6.0 -9.20 0.32 -17.8 Double, Clear W 1.3 13.0 10.0 -9.20 0.87 -80.2 Double, Clear N 1.0 12.0 40.0 7.30 1.06 310.3 Double, Clear E 1.3 3.0 6.0 -9.20 0.32 -17.8 Double, Clear E 1.3 5.0 40.0 -9.20 0.63 -230.2 Double, Clear E 5.0 6.0 24.0 -9.20 -0.23 50.8 As-Built Total: 319.0 -4257.5 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adajcent 416.0 3.6 1497.6 Frame, Wood, Exterior 13.0 2184.0 3.40 7425.6 Exterior 2184.0 2.20 4804.8 Frame, Wood, Adjacent 13.0 416.0 3.30 1372.8 Base Total: 2600.0 6302.4 As-Built Total: 2600.0 8798.4 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 18.5 11.50 212.8 Exterior Wood 38.8 12.30 476.6 Exterior 38.8 12.30 476.6 Adjacent Wood 18.5 11.50 212.8 Base Total: 57.3 689.4 As-Built Total: 57.3 689.4 CEILING TYPESArea X BWPM- = Points Type R-Value Area X WPM = Points Under Attic 1549.0 1,.20 1858.8 Under Attic 30.0 1617.0 1.20 1940.4 Under Attic 19.0 77.0 2.00 154.0 Base Total: 1549.0 1858.8 As-Built Total: 1694.0 2094.4 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 162.0(p) 8.9 1441.8 Slab-On-Grade Edge Insulation 0.0 162.0(p) 18.80 3045.6 Raised 667.0 0.96 640.3 Raised Wood, Adjacent 19.0 667.0 2.20 1467.4 Base Total: 2082.1 As-Built Total: 4513.0 FORM 60OA-93 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , Atlantic Beach, FL, PERMIT #: 3 BASE AS-BUILT INFILTRATION Area X BWPM = Points Type Area X WPM = Points 2423.0 7.40 17930.2 Practice#2 2423.0 7.40 17930.2 Winter Base Points: 25010.3 Winter As-Built Points: 29767.9 Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points 25010.3 0.55 13755.7. 29767.9 1.00 1.07 0.47 1.00 14878.6 FORM 60OA-93 WATER HEATING AND EPI SUMMARY Residential Whole Building Performance Method A - Details ADDRESS: , Atlantic Beach, FL, PERMIT #: BASE AS-BUILT WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 3 3803.00 11409.0 50.0 0.90 3 1.00 3718.49 1.00 11155.5 As-Built Total: 11155.5 EPI SUMMARY BASE AS-BUILT Cooling + Heating + Hot Water = Total Cooling + Heating + Hot Water = Total Points Points Points Points Points Points Points Points 14100.9 13755.7 11409.0 39265.6 10738.0 14878.6 11155.5 36772.1 EPI : 93 .6] 111E S74 ov fv rrrn. .•j r �cOp WE ENERGY PERFORMANCE LEVEL DISPLAY CARD For detailed information Doane of the EPI rating number Atlantic Beach FL or for any ITEM listed, ask your Builder for DCA Form 60OA-93 or Form 60OB-93 EPI= E3 0 10 20 30 40 50 60 70 80 90 100 excellent good acceptable The maximum allowable EPI is 100. The lower the EPI the more efficient the home. JOEl� ITEM HOME VALUE Low Efficiency High Efficiency SINGL CLR DBL TINT WINDOWS................................................ Double Clear I INSULATION............................................ R-10 R-30 Ceiling R-Value............................. 30.0 R-7 R-0 Wall R-Value.............................. 13.0 R-0 R-19 Floor R-Value.............................. 19.0 I I AIR CONDITIONER................................... 10.0 SEER 1i.0 SEER..................................................I.... 12.00 1 9.7 EER 16.0 HEATING SYSTEM................................... 6.8 HSPF 12.0 Electric HSPF........................................ 7.30 WATER HEATER..................................... 0.88 0.96 0.90 � Electric EF...................................... 0.54 0.90 Gas EF...................................... N/A 5.0 1.0 SolarEF...................................... N/A OTHER FEATURES................................. I certify that these e�rWy savviing�3at re�re uire7d for the Florida Energy Code have en installed in this house. q`t`S 6 �,der Address: �+�1° i �"G '3 �-y Signature: te: City/Zip: -,41A C 2-S q Florida Energy Code for Building construction-1993 Florida Department of Community Affairs FL-EPL CARD 93 RIGHT-J LOAD AND EQUIPMENT SUMMARY 10-1-98 File name: 2423 . BLD For: J & L Homes 445-26 SR 13 Jacksonville FL 32259 ( 904 ) 287-0049699-9725 By: Air Engineers, Inc . 10947 Beach Blvd. Jacksonville FL 32246 ( 904 ) 641-2333 Doane Residence Job # : Plan 2423 Sq. Ft . Wthr : Jacksonville AP FL Zone : Entire House WINTER DESIGN CONDITIONS SUMMER DESIGN CONDITIONS Outside db: 32 Deg F Outside db: 94 Deg F Inside db: 70 Deg F Inside db: 75 Deg F Design TD: 38 Deg F Design TD: 19M Deg F Daily Range Rel . Hum. . 50 % Grains Water 49 gr HEATING SUMMARY SENSIBLE COOLING EQUIP LOAD SIZING Bldg. Heat Loss 38562 Btuh Structure 28393 Btuh Ventilation Air 100 CFM Ventilation 2090 Btuh Vent Air Loss 4180 Btuh Design Temp. Swing 3 . 0 Deg F Design Heat Load 42742 Btuh Use Mfg. Data Rate/Swing Mult . 1 . 00 INFILTRATION Total Sens Equip Load 30483 Btuh Method Simplified LATENT COOLING EQUIP LOAD SIZING Construction Quality Average 1840 Btuh Fireplaces 0 Internal Gains 3332 Btuh Ventilation HEATING COOLING Infiltration 4854 Btuh Area ( sq. ft . ) 2423 2423 Tot Latent Equip Load 10026 Btuh Volume ( cu- ft . ) 2,1807 21807 Air Changes/Hour 0 . 7 0 . 4 Total Equip Load 40509 Btuh Equivalent CFM 255 146 HEATING EQUIPMENT SUMMARY COOLING EQUIPMENT SUMMARY Make Lennox Make Lennox Model CB29M51 Model 12HPB48 Type Air Handler Type Heat Pump COP/EER/SEER 12 . 0 Efficiency HSPF 7 . 3 0 Btuh Heating Input 0 Btuh Sensible Cooling 0 Btuh Heating Output 0 Btuh Latent Cooling 0 Btuh Heating Temp Rise 0 Deg F Total Cooling Actual Heating Fan 1359 CFM Actual Cooling Fan 1359 CFM Htg Air Flow Factor 0 . 035 CFM/Btuh Clg Air Flow Factor 0 . 048 CFM/Btuh Space Thermostat Load Sens Heat Ratio 81 MANUAL J: 7th Ed. RIGHT-J: V2 . 12 SN5144 Printout certified *by ACCA to meet all requirements of Manual Form J RIGHT-J CALCULATION PROCEDURES A,B,C,D Job # : Plan 2423 Sq. Ft. File name: 2423 .BLD 10-1-98 Zone: Entire House Procedure A - Winter Infiltration HTM Calculation* __-__--- __ -- ------------------------1--------------------------------------------------------_ _ 1 . Winter Infiltration CFM 0 . 7 AC/HR x 21807 Cu.Ft. x 0 . 0167 = 255 CFM 2 . Winter Infiltration. Btuh 1 . 1 x 255 CFM x 38 Winter TD = 10656 Btuh 3 . Winter Infiltration HTM 10656 Btuh / 376 Total Window = 28 . 3 HTM & Door Area Procedure B - Summer Infiltration-HTM-Calculation* -------------------- 1 . Summer Infiltration CFM 0 . 4 AC/HR x 21.807 Cu.Ft. x 0 . 0167 = 146 CFM 2 . Summer Infiltration Btuh _ 3045 Btuh 1 . 1 x 146 CFM: X 19 Summer TD - 3 . Summer Infiltration HTM g , l HTM 3045 Btuh / 376 Total Window = & Door Area Procedure C - Latent Infiltration Gain-------------------------------- 0 . 68 x 49 gr.diff . x 146 CFM 4854 Btuh ---------------------------- Procedure D - Equipment Sizing Loads---------------------------------- ----------------------------- 1 . Sensible Sizing Load Sensible Ventilation Load = 2090 Btuh 1 . 1 x 100 Vent.CFM x 19 Summer TD + 28393 Btuh Sensible Load for Structure (Line 19 ) = 30483 Btuh Sum of Ventilation and Structure Loads Rating and Temperature Swing Multiplier x 1 , 00 RSM 30483 RSM Equipment Sizing Load - Sensible Btuh 2 . Latent Sizing Load Latent Ventilation Load _ 0 . 68 x 100 Vent.CFM x 49 gr.diff . - 3332 Btuh Internal Loads = 230 x 8 No. People ++ 4 4840 Btuh 854 Btuh Infiltration Load From Procedure C _ 10026 Btuh Equipment Sizing Load - Latent - _---__- - ------------------------------------------ *Construction Quality is : a No. of Fireplaces is : 0 MANUAL J: 7th Ed. RIGHT-J: V2 . 12 SN5144 Printout certified by ACCA to meet all requirements of Manual Form J 2423 .BLD Job# Plan 2423 Sq. Ft . Zone :Entire House 10-1_98 MANUAL J: 7th Ed. ---- RIGHT-J: V2 . 12 --- SN5144 --- Page 1 - 1 Name of Room Entire House Whole House 2 Running Ft . Exposed Wall 162 . 0 Ft . 162 . 0 Ft . 3 Room Dimensions, Ft . 2423 . x 1 . 0 Ft . 4 Ceiings,Ft I Condit . Option 9 . 0 d 9 . 0 heat cool TYPE OF CST1 9 HTM Area Btuh Area Btuh E1 INO.RE Ht Clg Length) Htg Clg Length ) Htg Clg ---------- ------------------------------------- -----**** **** - **** **** 5 Gross a 12C 3 . 4 2 . 0 2184 2184 416 **** **** Exposed b 13C 1 . 4 1 . 3 416 **** **** **** **** 0 **** **** Walls and c 0 . 0 0 . 0 0 0 **** **** Partitions d 0 . 0 0 . 0 0 **** **** e 0 . 0. 0 . 0 0 **** **** 0 **** **** f 0 . 0 0 . 0 0 -- - ------------------------ --- -------------------- **** **** 6 Windows a 3C 27 . 6 ** 3190 87880 3190 87880 **** & Glass b 3C 27 . 6 ** Doors Htg. c 7I 33 . 2 **** p 0 **** d 0 . 0 ** 0 0 **** e 0 . 0 ** O 0 f 0 . 0 **** p 0 **** ------------------ ------------- ------------- ------- ---- **** 6891 300 **** 689 7 Windows North 23 . 0 300 0 0 0 & Glass NE&NW 0 . 0 0 **** **** 1395 19 **** 1395 Doors Clg. E&W 72 . 0 19 **** SE&SW 0 . 0 0 **** 0 0 0 South 0 . 0 0 **** 0 0 **** 0 Horz 0 . 0 0 **** 0 0 **** 0 8 Othr doors lOD 17 . 5 10 . 4 18 323 192 181 3231 192 1 jal b10D117 . 5110 . 4 391 6781 403 39 678 403 9 Net a 12C 3 . 4 2 . 0 1826 6246 3714 1826 6246 3714 Exposed b 13C 1 . 4 1 . 3 398 5370 5010 3980 5370 5010 Walls and c 0 . 0 0 . 0 0 0 0 0 0 0 Partitions d 0 . 0 0 . 0 0 0 0 0 e 0 . 0 0 . 0 0 0 0 0 0 0 f 0 . 0 0 . 0 0 0 10 Ceilings a 16G 1 . 3 1 . 4 1617 2028 2295 1617 2028 2295 b 16D 2 . 0 2 . 3 77 155 175 77 155 175 c 18D 1 . 7 1 . 9 0 0 0 -----0- -----0- -----0 11 Floors a 22A 30 . 8 0 . 0 162 4986 0 162 4986 0 b 19D 1 . 0 0 . 0 667 659 0 667 659 0 c 0 . 0 0 . 0 0 0 0 -----0- -----0- -----0 ------------------------------- -------------------- 121 Infiltration a 128 . 31 8 . 1 3761 106561 3045 --376 -10656 --3045 _ ------------- --- ---------------- **** **** 3---- **** 5056 13 Subtot Btuh Loss=6+8 . . +11+12 35056 **% 3506 **** 14 Duct Btuh Loss 10� 3506 **** 38562 **** **** 38562 **** 15 Total Btuh Loss = 13+14 --------------- ---- **** 2400 8 **** 2400 16 Int . Gains : People @ 300 8 **** 4800 4 **** 4800 A pl . @ 1200 ****4 **** 25812 **** **** 25812 17 Subtot RSH Gain=7+8 . . +12+16 10� **** 2581 10% **** 2581 18 Duct Btuh Gain **** **** 28393 19 Total RSH Gain=( 17+18 ) *PLF ***00 28393 ***00 1359 1359 20 CFM Air Required 1359 1359 --- Printout certified by ACCA to meet all requirements of Manual Form J -- MANUAL J: 7th Ed. RIGHT-J: V2 . 12 SN5144 RIGHT-J WINDOW DATA Job # : Plan 2423 Sq. Ft . File name: 2423 .BLD 10-1-98 W S D W G L S S O N A S O O W c W S N H N K I A L O T H V G N H V V H H A A DY R L Z E M D G Z L O X Y T M R R W Whole House a n s a c n n n y 2 90 1 . 0 1 . 0 0 . 0 1 . 0 38 . 0 165 . 165 . a n e a c n n n y 2 90 1 . 0 1 . 0 0 . 0 1 . 0 72 . 0 70 . 0 58 . 1 a n n a c n n n y 2 90 1 . 0 1 . 0 0 . 0 1 . 0 23 . 0 40 . 0 0 . 0 a n W a c n n n y 2 90 1 . 0 1 . 0 0 . 0 1 . 0 72 . 0 44 . 0 36 . 5 CITY OF j - Office of Building Official REQUEST FOR INSPECTI N /7 3 6 r, - 5� Permit o. d Date A.M. P.M. Time Received Locality Job Address Contract MECHANICAL owner'sPLUMBI ❑ ELCAL Air ting CONCRETE & ECTRI Name ❑ Rough Heating ❑ E h Wiring Top put BUILDING 0 Roug h, Fire Place Footing Temp Pole Sewer Pre Fab Framing ❑ Slab Final Re Roofing 0Lintel P.M. Insulation READY FINSPECTION OR Friday—� Thurs. Wed. Tues. A.M. Mon. Z 7� P.M. Final Inspection ❑ Inspection Made Certificate of Occupancy Inspector Date nn //II CITY OF Office of Building Official REQUEST FOR INSPECTION Permit No. Date Time P.M.' Received ✓� 14 r_ G �� Locality Job Address Owner's Contractor /V Name PLUMBING MECHANICAL CONCRETE ELECTRICAL Air Cond. & E BUILDING Rough Wiring ❑ Rough ❑ Heating Fire Place Temp Pole ❑ Top Out ❑ Framing Slab ❑ Sewer ❑ Re Roofing F] Final Pre Fab Insulation Lintel READY FOR INSPECTION Friday Wed. Thurs. Tues. Mon. 0 ,,-'30 n A.M. `r P.M. Inspection Made Final Inspection ❑ Certificate of Occupancy Inspector Date CITY OF &__������ C.,/� Q Official Office of Building -C-TION REQUEST FOR '7 3 ss�� Permit No. A.M. Date P.M. Time Received LocalitY/� Job Add s MECHANICAL C�J Y v" Contractor SING C Owner's ELECTRICAL PLUM ❑ Air Cond. & TE Rough ❑ Heating ❑ ING CONCRE r Rough Wiring 0 Top out ❑ Fire Place BUi Footing - Temp pole 0 Sewer pre Fab Framing � Slab Final A.M. Re Roofing Lintel INSPECTION Insulation READY FOR Friday Thurs. Wed. Tues. � A.M. Mon. P.M. Final Inspection inspection Made Certificate of Occupancy I ; Inspector Date CITY OF B Office of Building Official REQUEST FOR INSPECTION Permit N/ Date / M. Time / Received oc rty Job Add O Owner's Contractor PLUMBING MECHANICAL Name ELECTRICAL CONCRETE Rough ❑ Air Cond. & BUILDING ❑ Rough Wiring ❑ ❑ Heating 11 ❑ Footing Temp Pole ❑ Top Out ❑ Fire Place Re Roofing Final Framing Slab ❑ Sewer Pre Fab Insulation ❑ Zel / R ADY FOR INSPECTION Wed. — Friday P.M. / Thus. rs. Mon. A.M. P.M. a Final Inspection Inspection ❑ Certificate of Occupancy Inspector Date 's TRANSMI'T'TAL DOCUMENT FOR JEA DATE: The following permits have passed "rough" inspection: Permit No. Address ��-�-�- Z 72 c S Y-3 Please update your records accordingly. Than yo , BUILDING CLERK CITY OF ATLANTIC BEACH /vcb CITY OF lgie=A_6l • ' /O / `7369 ti Office of Building Officia m 1 -74174. REQUEST FOR INSP ION 7c/10 Permit No.� E Date Timet l L Received LL J Locality Job Address / Owner's200c, �(i}N� ontractgot or ^ � + D � eCHANIC CONCRETE ELECTRICA PLUMBING UILDIN Rough ❑ Air Cond. & F.ming T Footing ❑ Rough Wiring g �* Heating �❑ Slab ❑ Temp Pole ❑ Top Out Re Roofing n Final ❑ Sewer El Fire Place Insulation F-1LintelPre Fab READY FOR INSPECTION A.M. Tues. ed. Thurs. Friday P.M. Mon. W InspectionMade Final Inspection ❑ Inspector Certificate of Occupancy ❑ Date 7F sA�& 51r,� MAP SHOWING SPECIFIC PURPOSE SURVEY OF: LOT 8, BLOCK 7, OCEAN GROVE, UNIT NO. 1, AS RECORDED IN PLAT BOOK 15, PAGE 82 OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA. rr� ;;r . "�AJI trees to remain must be barricaded A b Dv i E l V �1 � I I-R. l• REQUIRED s minimum of 5 ft. from the trunk of each FOR ANY TREES REMOVED, tree. Barricades rn:.,[ L2 insta!led BEFORE site clearing and remain in place during ALL phases of construcbon.," LOT 1, BLOCK 7 LOT 2, BLOCK 7 5_0.0_0' _ _ _ FOUND 1" IP 6' UTILITY EASEMENT 8Y PLAT "r W NO ID _ _ _ _ _ _ _ _ W_ _ _ [ ] C 15"P 00 12"P Q _ 20' BRL a t, %8"K m 0 ltit�° .K Q a r :�t�°may ® 2"CH RRY ,� LOT 7, BLOCK 7 Ul- 7..K W o 0 - 5"K �PG �(11»K 0 V) O I-�'fd"K� i 1 O..K � (D r o K I/d°r Z W oO 1 wO 8.:P O "K � m - ® ;r1 5d �Fi LjX8K 0 1 ,K 11 K ® 1 0 J G ® �8"K 6"K I o Tree Removal Approved as Noted 8"K, K By �� $,.K® —8..KI Date ,, I g 4"K g�f � w 8"K ro 10"K 5"K e 0' ®12"K K 0 Qd 'X �FOUND 1" IP ' 11"P •" NO ID 9"K® 5O. 724 $,HE L L STREET r A/ p�iL r 40' RIGHT-OF-WAY (SHELL & DIRT ROAD) NOTES:0- ' LEGEND 1.) THE SPECIFIC PURPOSE OF THIS SURVEY IS TO SHO TREES BRL DENOTES BUILDING RESTRICTION UNE ACCORDING TO CITY OF ATLANTIC BEACH SPECIFICATIONS. K DENOTES OAK TREE 2.) NO BUILDING RESTRICTION UNE BY PLAT, BUT THERE P DENOTES PALM TREE MAY BE RESTRICTION LINES OR EASEMENTS-THAT -- ® DENOTES TREES (SEE DESCRIPTION FOR SIZE do TYPE) AFFECT THIS PROPERTY BY ZONING OR RECORDED Q DENOTES FOUND 1" IRON PIPE IN THE PUBLIC RECORDS OF THIS COUNTY THAT ARE ID DENOTES IDENTIFICATION NOT SHOWN ON THIS SURVEY. IP DENOTES IRON PIPE 3.) THIS PROPERTY LIES IN FLOOD ZONE "X" BY FLOOD MAPS REVISED 4/17/1989, COMMUNITY PANEL NUMBER 120075 0001D. 4.) BUILDING RESTRICTION LINES SHOWN HEREON ARE BY ZONING PER CLIENT REQUEST. CITY OF ATLANTIC BEACH TREE REMOVAL APPLICATION All applications must be received by 5 P.M. on the MONDAY prior to the scheduled meeting in order to be placed on the agenda for consideration INCOMPLETE _APPLICATIONS WILL NOT BE PROCESSED. APPLICANT NAME ADDRESS TELEPHONE 2. ADDRESS OR LEGAL DESCRIPTION OF PROPOSED TREE REMOVAL 3. DESCRIBE PURPOSE OF TREE REMOVAL: Aj 6Z' 4. SPECIFY TREES PROPOSED FOR REMOVAL AS FOLLOWS: NUMBER SPECIES DIAMETER (DBH) CONDITION 7 a k ti (NCS _ -_ 5. TOTAL NUMBER OF TREES TO BE REMOVED: 1 �� 6. TOTAL NUMBER OF INCHES OF TREES TO BE REMOVED: 7. SPECIFY PROPOSED REPLACEMENT TREES AS FOLLOWS: NUMBER SPECIES DIAMETER (DBH) RECEIVED `' 3 Inn, r c!WC c -v ✓ Q1`"' 14 1996 ity of Atlantic Beach Building and Zonin$ 8. ATTACH SITE PLAN INDICATING THE FOLLOWING.- a) OLLOWING:a) Site topography, including proposed grade changes b) Existing and proposed buildings and other improvements with dimensions and required setbacks c) Tree protection zones as applicable d) Location, DBH and species of all trees with a DBH of six inches or greater e) Location, DBH and species of all trees with DBH of less than six inches proposed to be used for mitigation f) Specify trees of unique or special character g) Each tree proposed for removal clearly marked with a "X" h) All existing and new trees proposed to be used for mitigation clearly marked with brackets "[ ]" 1) Location of utilities, easements and material storage areas 9. ALL TREES PROPOSED FOR REMOVAL MUST BE CLEARLY MARKED ON SITE BY RED SURVEYORS RIBBON. 10. ALL EXISTING TREES PROPOSED TO BE USED FOR MITIGATION MUST BE CLEARLY MARKED ON SITE BY BLU SURVEYORS RIBBON. 11 . INCOMPLETE APPLICATIONS WILL NOT BE PROCESSED. I HEREBY AGREE TO COMPLY WITH ALL PROVISIONS OF CHAPTER 23, ARTICLE II, TREE PROTECTION, AND ALL OTHER APPLICABLE CODES AND ORDINANCES OF THE CITY OF ATLANTIC BEACH: X� / z APPLICANT GNATURE DATE A—6—1— OWNS SIGNATURE /�' / DATE —� �,✓;' / �� /���"t,s!/ ' C/ �G, Lam= /moi ���iis.,, �iL/or. APPROVED : TREE CONSER ION BOARD CHAIRMAN DATE TREE PROTECTION PROPERTY LINE PRIVATE PROTECTED TREE020.00' DBJHF��LOR MORE --- ----- -- - -- ------ I i 7.50' I PRIVATE I I PROTECTED I I TREE I 0I to PRIVATE PROTECTED TREEI� PRIOPERTY I � 10 0 1 D B H OF 20- OR MORE °J of I I o PROPERTY 1I (D BH OF 10- OR MORE IN LINE oI COMMERCIAL & INDUSTRIAL PRIVATE = w I � PROPERTY) PROTECTED m o i > > l TREE owl I � I 7.50' PRIVATE PROTECTED TREE D 8 H OF 6" OR MORE 20.00' PROPERTY v LINE PROPERTY LINE SIDEWALK SIDEWALK PUBLIC PROTECTED TREE D 8 H OF 6" OR MORE (PUBLIC STREET) (PUBLIC STREET) A. PRIVATE PROTECTED TREE 1. ANY TREE WITH A D B H OF: SIX (6) INCHES OR MORE LOCATED ON ANY LOT WITHIN TWENTY (20) FEET OF A STREET RIGHT-OF-WAY OR REAR PROPERTY LINE. SIX (6) INCHES OR MORE WITHIN SEVEN AND A HALF (7.5) FEET OF ANY OTHER PRIVATE PROPERTY LINE AND TWENTY (20) INCHES WITHIN ANY OTHER PORTION OF THE LOT. (EXCEPT 10 FOR COMMER- CIAL & INDUSTRIAL PROPERTY) 2. ANY CHAMPION TREE SO DESIGNATED BY THE FLORIDA DIVISION OF FORESTRY, QpARTMENT OF AGRICULTURE. B. PUBLIC PROTECTED .TREE SAME AS PRIVATE PROTECTED TREE PLUS ANY TREE SIX (6) INCHES OR LARGER WITHIN CITY RIGHT-OF-WAY. C. EXCEPTIONAL SPECIMEN TREE ANY TREE ON PRIVATE OR PUBLIC LAND DESIGNATED BY THE CITY COUNCIL AS A SPECIMEN TREE. TREERRO BUILDING AND ZONING INSPECTION DIVISION CITY OF ATLANTIC BEACH ` ATLANTIC BRACH, FLORIDA 322331 APPLICATION FOR MECHANICAL PERMIT CALL-IN NUMBER IMPORTANT — Applicant to complete all items in sections I, II, III, and IV. tACJ1T{ON Street Address: ` ` ,� x n OF Isfer►ectins Streets: Between L. As WILDING sut,-diritl.e II. IDENTIFICATION — To be completed by all applicants . tr, consideration of parmif given for doing the work as described in the above statement we hereby agree to pslrform said work in accordance with the aHacMd plans and specifications which are a part hereof and in accordance with the City of Jacksonville ordinances and sfondards of good practice listed therein. aster Name of weckeaical Mastrealara i,..bec►M (Priaf) (i Nath st M4,/er+y O.aar .� S:psatirre 01 Owaa► Signefure of er Art4�.rieed Alieat Architect or Engineer 111. G&OIRAL INFORMATION T d 16"fiall W: B' l� IS OTHER CONSTRUCTION 991 NO DONE ON THIS BUILDING OR SITE? ❑ Gw—❑ LP ❑ Natursl ❑ toatrel WARY IF YES, GIVE NUMBER or CONSTRUCTION ❑ 01 PERMIT ❑ Ofh.+ — Sr«+h V. WBOKM AL WIF11twT TO K *WALLO NATURE Of WORK (Pp to 110I= Kat of cempoftetc!ats ea seof N,p tial residential or O Commercial Heat 0 sr. ❑ Receaaed .21C."W L1 poo► New Bulldlnp ❑ ROOM � O Existing Building -� �✓ Sy.1we: IAafasial Tk+td,na__, O Riplacement of existing system � � ugh ��--� •c l ns New Installation(No system previously Installed). O Extenslon or add-on to existing system ❑ O Other — Specify-- — - Co.lwp Maeer. GreHy ❑ Am grinklees: Newr►er of L—A. r ❑ E wtw ❑ I *"Ft ❑ Eaedator Mit VACS 004 OFFM UM ONLY ❑ Gmeg-8 Iwr*00e - - IS I IRseaive�l ❑ Ta.hRemAs ❑ LPG toei,.rL,. 1»WA«I (3 U*fvW po"I m"Wer hnrlil /1'pev.d by Data ❑ We" ❑ O+br — sr.uh ►«Rat he L.16T ALL EQUIPMENT Alit CONDI•IMONLNG AND REFRIGERATION EQURMENT 1Anabetr Ualta DowrtpRleat Ko"Numb" t =Uftcwm IVEATING • PURNACES. !OILERS. FIREPLACE Afpgovft )ttaabw v*AA Deecrtptim Me"Ntmabor I[a>sl batism PSR-3844 17462 A DEPARTMENT OF BUILDING CITY OF ATLANTIC BEACH PEP-MIT INFORMATION ------- LOCATION INFORMATION ---- ,--�rmit Number: 17462 Tress : 79 SHELL STREET Permit Type: SWIMMING POOL ATLANTIC BEACH . FLORIDA 3223' .1 LEGAL DESCRIPTION -- ---_-..._of Work:NEW ,. * 8 Twp : 0 ;'11onstr . Type *WOOD FRAME Block : 7 Lot : Proposed Use: SINGLE FAMILY Section: 0 Subd* Rng* Dwellings : 0 Subdivision: OCEAN GROVE UNIT NO. 1 Est . Value: 0 .00 inprov . Cost : 9, 155 . 52 Total Fees : 30 .00 Amount Paid: 30 .00 Date Pa­A- 11/19 ",998 POOL PER PLANS INFORMATION APPLICATION FEES DOA NE ERM 111' 00 Adr : 1679 SEMINOLE RCIAD ATLANTIS"- BE_T,-,;'_7,1i LOR I DA 32"2.3" -one ( 9041,2*"' 050 , CONTRACTOP INFORMATION ame: SWIMMING POOL iijC I AL I STS INr' Jdr: 9449 CRAVEhi-,,ROAD JACKSONVILLE, FL 3225 .,ic: CP01012185 Exp : vpe; NOTES: NOTICE - INSPECTIONS MUST BE REQUESTED AT LEAST 24 HOURS PRIOR TO INSPECTION BUILDING MATERIAL, RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE, AND MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER "FAILURE TO COMPLY WITH THE MECHANICS' LIEN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS." ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW. ATLANTIC BEACH BUILDING DEPARTMENT By: RECEIVE® CITY OF ATLANTIC BEACIi NOY 1 8 1998 APPLICATION FOR POOL PERMIT City of Atlantic Beach 5,. 1 C� Building and Zoning job Addresst-t S�C� Lc t n g Dlock # Subdivision QCEAN &U\I6 0-,;ner 'POUGLA19 s tVOA.Nt:5 Address 761 S4E LL MF-L-T , ATLANtic- 3Ekc. l . FL, - Contractor LContractor MA0.y- F-• VAut Hr1 /Sw iMMiNG- RoC_ W6-C AL S-'S+ INe- ,Aches s U41 l e RAVErJ PP. . JA X.. PC— 3 22-5 7 TELEPHONE(Joq) 7,3 1 ^0011 License I]urber ePC_ [ 2 l85 Valuation S 1691000 .0o Gallons 1 , P55,52- SITE 55,y2SITE PLAN front Se a- a a rD r� rear Sicnature O;:,ricr Date Signature Contractor Date —,?g ti b IL N a r RECEI'VE'Di Nov I A 1998 City of ,Atlantic Beach Z � Building and Zoning OO O cn I 0 I D m I I j I _ I I X' I — I I I I I - ., j S •� � I � I z od ,Z, 70 CA - - n M (1 � N MAR SHD W I'NG BDUVDAR Y SURVEY Da E �2 LOT 8, BLOCK 7, OCEAN GROVE, UNIT NO. 1, AS RECORDED IN PLAT BOOK 15, P ; OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA.. LOI'; BLOCK 7 LOT 2, .d000A' 7 P- ine _ i[ne •r. � X33 3E' � 41 46 C fi 0 ►, AZ 14 LAj '4 era I'oo;.i ..s' 50. 00 SH EC L 5'Tib. E T �o'Ric3NT OFWa y NOTES 1 �6�G�G�\G� NO BUILDING RESTRICTION LINE BY PLAT, BUT THERE MAY BE RESTRICTION LINES OR EASEMENTS THAT AFFECT THIS 4� PROPERTY BY ZONING OR RECORDED IN THE PUBLIC RECORDS OF THIS COUNTY THAT ARE NOT SHOWN ON THIS SURVEY. THIS PROPERTY LIES IN FLOOD ZONF "X" BY FLOOD MAPS REVISED 4/17/1989, COMMUNITY PANEL N0, 120075 0001 D, CERTIFIED TO : Nov-18-98 02:41P 904 P.01 p c 1' iGw rrrr �.wa i( Ip f 1S •A.CO Pont. a* .{ "10 rf FFF �����' 111 p r..t�/Cf,r-V-- atirr of 10j"IvI I I r r I I t r I A t r.arwRa r.oon.aar•. QIu (nllpttt it tttavf Conran: 1 he undersigned hereby informs all concerned that improvements will be made to certain real property, and In accardsnce with section 713.13 of lite Fiorlda Statutes, lite following Information is stated in this NOTICE OF COMMENCEMENT, Descriplion of properly......1.o T._rR�-...r.... a't'a.�1�_.7_r._. ocf-ps..W. ........o?.IL .46-1...V..N.1?'......NA......t.)......, Ac. eco. ��..__Ln}........PEAT..._..f3.o.o..K._..1.57_.....P.14v>~.....5.....Z.......o... ....TA.C......... Gv.n.a.� ?1 ... ...P r3u..c.....Raa.Rs........Q ........D.u.v,�..+�.... General description of ......_ ..........................._.............._............. Owner ._..i.r.O.U.&-(-kC...... ......... Q.l..i. .6+........................................................................................................_.........,. Add,era .-Alp 7.9. Ir ._AT1gnJ12C.Bb.9�t1. R. r 3 22;3 Owner's interest in site of the improvement ................................._..........._-........,........._...... ,...... Fee Simple Tide holder(if colter than owner) Name......'SAM.C...................................................._...................................................__.................................................................. Address ...'S.Mt...........----......../..........................................................................................................__..............................�......�_.V..t_............. Conlrador}.I�AQ.{—6-......Y.f�I.AG.I Addr•s.....-1_4.�.....1......1,r ..F.. ..... p..t,... e��..�o.^�.v.!:. 4%r...Y-..�..,...... .Z.. ... �............... Surely (if any)....... . .......--........................»_._........._...-_._....__....-..».........._.»...,...._.._......_._._._._..._.._....»._._..._- -......... Address-................N../A -.................................................................................................-Arnasll of bond II JQ1A.......,... Name of person within the State of Florida desiynaled 6y owner upon whore notice or olher tot can anls may 6e served. Address �.�G.��..........��.l�l� . . .._...�.Eye; .........r . . .�... .. ........4-r1 _ n.c.. �.a .L.�� In addition to himself,owner designates the following person to receive a copy of lite(.tenor's Notice as provided in Section 713.13(1) lF}, Florida Statutes. (Fill In at Owner's opllon(, Name . -............................»... -._.................._..._....._._..»_.......»........_.»...._._...».._.......».__...._._....»._.... Address .......................»......._. .......................................... THIS a►aet Pon rs[aowosw'e vea esrt.v Owner Sworn to end subscribed before Ind this.............._.............. ... IVOE«.w,Wa:n .....`..7...........dayoIr ..,....A�,o. !/. .._..............._..._...19..QS' AR sy CIM"CO.7n4/2092 nuc No.CC 762547 It, Holsry iu611c cD `9 3 n r � cD m v ------------Receipt#--11263------------- Q O Z_� HENRY W. COOK U CLERK CIRCUIT COURT = 330 E. BAY ST RM 103 m or JACKSONVILLE, FL 32202 D 0 DUVAL COUNTY �' 0 �'a 904-630-2043 o O -------------- ------------------------ > Doc# 98281742 No. Pages: 1 02:16:08 P.M. cn RECORDING FEES $ 5.00 TRUST FUND FEES i 1.00 z Total 3 6.00 n Cash Tendered i 0.00 Check Ant. Tendered i 6.00 Change Due f 0.00 Balance 3 0.00 Total number of documents: 1 Total number of fees 2 (� Check #5154 ---------------------------------------- Paid By SWIMMING POOL SPCLTS on 11-18-98 at 02:16:07 P.M. with SANDRA E HENDERSON icn n o 0 C7 0 C: 7 C m ° oas (D 42— F) Cy)Cy) v Z cn 0 -' 0 X00 < � 0 0 �. c0 o v O0 o Q cn 0 N cn CITY OF �' �4l�lic l3e�cls-&;&I r� Office of Building Official REQUEST FOR INSPECTION -7 VO J _ _ Permit No. / Date Time M_ Received Locality Job Address � A�� Owner's Contractor NameLUMBING MECHANICAL BUILDING CONCRETE ELECTRIC ❑ Rough Wiring ❑ Rough Air Cond. & Framing ❑ Footing �o Out p- Heating ❑ Temp Pole p ❑ Fire Place In Roofing ❑ Slab er ewnsulation El Lintel Final Lintel Pre Fab READY FOR INSPECTION M. J ues. Wed. Thurs. Friday Mon. C' A.M. P.M. Inspection Made � �. Final Inspection ❑ Inspector Certificate of Occupancy ❑ Date DATE PRE-SERVICE DIVISION JACKSONVILLE ELECTRIC AUTHORITY 3:3 WEST DUVAL STREET JACKSONVILLE, FLORIDA 3«0 THE FOLLOWING FINAL INSPECTIONCS> HAVE BEEN MADE AND ARE SATISFACTORY : `7Y_0y --7-Y ----- -- ----- ----- ------------------ ------- ---------- -- ---- / l_7 s�� — _- - ---------- ------------------------------------------ ------ ------------------------------------------ ------- ------ ----------------------------------- -------------- Enclosed are the blue copies of the permits. SINCERELY, _ 1 BUSI NG ISPECTION DI ISION cc : FILE CITY OF ATLANTIC BEACH APPLICATION FOR PLUMBING PERMIT JOB LOCATION: 7 9 S h e// -f OWNER OF PROPERTY: g4 Al TELEPHONE NO. PLUMBING CONTRACTOR /1l,4�e CONTRACTOR' S ADDRESS : Z f� STATE LICENSE NUMBER: TELEPHONE: HOW MANY OF THE FOLLOWING FIXTURES INSTALLED SINKS SHOWERS LAVATORY WATER HEATERS Z BATH TUBS ` DISHWASHERS URINALS DISPOSALS 3 CLOSETS WASHING MACHINE FLOOR DRAINS SHOWER PANS SEWER WATER REPIPE OTHER TOTAL FIXTURES: x $3 .50 + $15 . 00 MINIMUM PERMIT FEE - $25.00 SIGNATURE OF OWNER: SIGNATURE OF CONTRACTOR: , --------------------------- INSTALLATION OF PLUMBING AND FIXTURES MUST BE IN ACCORDANCE WITH THE MOST RECENT EDITION OF THE SOUTHERN STANDARD PLUMBING CODE. CALL A DAY AHEAD TO SCHEDULE INSPECTIONS - (904) 247-5826 SEWER CONNECTIONS MUST BE CALLED INTO PUBLIC WORKS FOR INSPECTION PRIOR TO COVERING UP - (904) 247-5834 CITY OF ATLANTIC BEACH, FLORIDA 7 o7 Approved by APPLICATION FOR ELECTRICAL. PERMIT TO THE CHIEF ELECTRICAL INSPECTOR: DATE: ' v oop.mbefL J Z19- IMPORTANT NOTICE: IN CONSIDERATION OF PERMIT GIVEN FOR DOING THE WORK AS DESCRIBED IN THE FOLLOWING, WE HEREBY AGREE TO PERFORM SAID WORK IN ACCORDANCE WITH THE ATTACHED PLANS AND SPECIFICATIONS, WHICH ARE A PART HEREOF, AND IN ACCORDANCE WITH TYE ELECTRICAL REGULANS, CODES AND CITY OF ATLANTIC BEACH ORDINANCES. 3� EC-00017.13 Munson and Bryan Electric Co. '14 23 ELECTRICAL FIRM: MASTER ELE!tTRICIA SIGNATURE JOURNEYMAN NAME J� ►- Ho pigs, ClEi-) nn cc �- ADDRESS:_�"Iy�l� l I I�e�-t RFD r BOX I � nEIC �VBLDG.SIZE v RES. ( ) APT. ( ) COMM. ( 1 P IC ( ) INDUS. ( ) NEW ( T- OLD ( ) REW. 1 1 ADDITION ( ) TRAILER ( 1) TEMP. ( 1 SIGNS ( ) SQ. FT. SERVICE: N W ( 1 INCREASE ( 1 REPAIR ( 1 FEE CONDUCTOR SIZE 4 0, a00 AMPS COPPER ALUM, SWITCH OR BREAKER o�00 AMPS PH W VOLT Y EXIST.SERV.SIZE AMPS PH W VOLT RACEWAY FEEDERS NO. SIZE IND. SIZE NO. SIZE LIGHTING OUTLETS CONCEALED OPEN TOTAL RECEPTACLES CONCEALED OPEN TOTAL 0.30 AMPS. 31.100 AMPS. SWITCHES INCANDESCENT FLUORESCENT &M. V. FIXED 0.100 AMP6. OVER APPLIANCES i I I BELL TRANSF. AIR H.P. RATING H.P. RATING CONDITIONING COMP. MOTOR OTHER MOTORS AMPS CEIL HEAT: KW-HEAT 0.1 OVER MOTORS H.P. VOLTAGE PHS NO. 1 H.P. VOLTAGE PHS MISCELLANEOUS TRANSFORMERS: UNDER 600 V. OVER 600 V. / 7YDY CITY OF ATLANTIC BEACH, FLORIDA Approved by APPLICATION FOR ELECTRICAL. PERMIT TO THE CHIEF ELECTRICAL INSPECTOR: DATE: Kwem Jei- X19 8 IMPORTANT NOTICE: IN CONSIDERATION OF PERMIT GIVEN FOR DOING THE WORK AS DESCRIBED IN THE FOLLOWING, WE HEREBY AGREE TO PERFORM SAID WORK IN ACCORDANCE WITH THE ATTACHED PLANS AND SPECIFICATIONS, WHICH ARE A PART HEREOF, AND IN-ACCORDANCE WITH TOE ELECTRICAL REGULA NS, CODES AND CITY OF ATLANTIC BEACH ORDINANCES. 3� EC-0001713 Munson and Bryan Electric Co. ELECTRICAL FIRM: c r MA ER ELE ICIAI�SIGNATURE JOURNEYMAN NAME �� L H ome DI `LnCADDRESS: -1q Shei I �P_e.+- RFD BOX BLDG.SIZE < L_N_AL - �0" 4�t � � T_P(1 / BETWEEN: �erninole W r'1�I �1�-IJI(t RES. ( 7 APT. ( ) COMM. ( 1 PUBLIC ( 1 INDUS. ( 1 NEW (� OLD ( 1 REW. ( 1 ADDITION ( ) TRAILER ( ) TEMP, (`"1 SIGNS 1 ) SQ, FT. SERVICE: NEW (W INCREASE ( ) REPAIR ( 1 FEE CONDUCTOR SIZE AMPS COPPER ALUM. _ SWITCH OR BREAKER M I PH 3 W O/gL LT 'RACEWAY EXIST,SERV. SIZE AMPS PH W VOLT RACEWAY FEEDERS NO. SIZE IND. SIZE NO. SIZE LIGHTING OUTLETS I CONCEALED I OPEN I TOTAL RECEPTACLES CONCEALED I OPEN I TOTAL 0•JO AMB. 31.100 AMPS. SWITCHES INCANDESCENT FLUORESCENT&M.V. FIXED 1 0.100 AMPS. OVCR APPLIANCES i I I BELL TRANSF. AIR H.P. RATING H.P. RATING CONDITIONING COMP. MOTOR OTHER MOTORS AMPS CEIL HEAT: KW-HEAT 0.1 OVER MOTORS H.P. VOLTAGE PHS NO, 1 H.P. VOLTAGE PHS MISCELLANEOUS Oct-14-98 09:33A P-Ol in-RICE QUOTE OTE APPLICATION FOR WATER ANDIOR SEWER TAP APPLICANT NAME MAILING ADDRESS PHONE NUMBER �:.�`� ��� 70 S7) DATE_1 SERVICE REQUESTED �/ t SERVICE LOCATION &t I UC 7j 'Qt� J/7LS,c� / DATE SET TO PUBLIC WORKS A) -- DATE RETURNED TO BUILDING DEPARTMENT PUBWC WORKS DEPARTMENT PRICE QUOTE RESPONSE WATER: SA 4 3 `ly'' SEWER: 611'q_��T e x sOTHER- PRICE QUOTE PREPARED BY: qj ;ait�u:re - Title DATE NOTIFIED OWNER i0-d ZL85-LVZ-b06 XLLENZ:)W iC.A-ARH ` SZ =01 86-ZZ-gz)O 13 -3 CITY OF ATLANTIC BEACH PERMIT CALCULATION SHEET Address Date /-nn f o Heated Square Footage - S /0 Garage/Shed �2 (a $ per sq f (� $ 0 per sq ft = Carport/POrcr; =_(a $ 0 per sq ft = a LPC1h .a O sq 'Ft Patio _____—per - - � S_ � t/ C, TOTAL VALUATION : �/O O-0 o �� 416 (rJ / 1St s 000 Tot �Va `f t1 on S $v�. per thousand Remaining value or portion thereof D TOTAL BUILDING FEE + ij Filing Fee (Q) Fireplaces @ $15 . 00 S �Lo 5 $ � BUILDING PERMIT FEE 5 WATER IMPACT FEE $ S_ SEWER IMPACT FEE .....� WATER METER/TAP TT S d� CAPITRL IMPROVEMENT S SEWER TAF RADON (HRS) . 0050 r SECTION H PAVING $ HYDRAULIC SHARES $ CROSS CONNECTION 4 yZ SURCHARGE 0056 $ C)ThEF: GRAND TOTAL DUE :.f • Piumbing ADDITIONAL PE OR FEES : Mechanical-_- ; SwimminaPooi Electric/New Electric/Temp— Floor Floor E evation Septic Tank Survey Other CALCULATIONS and/ or NOTES: 10-05-1998 14:20 904 791 9503 DONAHOO,DONAHOO,BALL P.02 Bk i 9079 pg i 2436 — e437 Doc# 98233704 Prepared by and after Filed 6 Recorded recording return to: 09/24/96 1109125 A.M. HENRY W. COOK Haywood M,Ball,Esquire CLERK CIRCUIT COURT M Donahoo,Donahoo&Ball, P.A. DUVAL COUNTY9 FL ,r 2925 Barnett Center REC. t6 10.50 N 50 N.Laura Street Jacksonville,FL 32202 a NOTICE OF COMMENCEMENT n STATE OF FLORIDA O COUNTY OF DUVAL p g Buildin Permit A� Tax Parcel Identification No.: 169583-0000 The undersigned hereby give notice that improvements will be made to certain real property, and in accordance with section 713, Florida Statutes, the following information is provided in this notice of commencement. 1. Description of real property to be improved: Lot 8, Block 7, OCEAN GROVE UNIT NO.: 1, according to the trap or plat thereof as recorded in Plat Book 15, Page 82,Public Records of Duval County, Florida. at Seminole Road, Atlantic Beach, FL 32233 2. General description of improvements: Construction of a single family residence. 3. Owner Information: (a) Douglas S. Doane, 1679 Seminole Road, Unit 2, Atlantic Beach, FL 32233 \ (b) Owner's interest in the site of the improvements: Fee Simple y 4. Contractor: J & L Homes,Inc. 445-26 State Road 13, Suite 347 Jacksonville, FL 32259 ATTN: Larry W. Jordan 5. Surety on any payment bond: None 10-05-1998 14:21 904 791 9563 DONAHOO.DONAHOO,BALL P.03 Book 9479 PV 2437 6. Name of any lender making a loan for the construction of the improvements: American Mortgage Capital, Inc. 6190 NW 11 th Street Ft, Lauderdale, FL 33313 7. Persons within the State of Florida designated by owner upon whom notices may be served as provided by Section 713.13(l) (a) 7, Florida Statutes: N/A 8. In addition to himself,owner designates the following person to receive a copy of the lienor's notice as provided in Section 713.13 (1) (b), Florida Statute (Name, Bank and Address): Haywood M. Ball Donahoo, Ball, McMenamy &Johnson, P.A. 50 N. Laura Street, Suite 2925 Jacksonville, FL 32202 9. Expiration date of notice of commencement is one (1) year from the date of recording. — A-04— "�/ DOUGLA . DOANE I* SWORN TO AND SUBSCRIBED before me this Say in September, 1998,by DOUGLAS S. DOANE, who is [ x ] personally known to me or [ ] have produced as identification. [check one] Notary Public g—AY p M.BALL State of jlloY�&OtbaWe 13AL,L JOSM y Comm.#CCW078 expires Nam(Atam#'2t. 2001 Commission No. tea"Iflu �'' My Commission Expires: C;\OFFICE\WPW IN\W PDOCS\RE\DOANE\COMMENCE.NOT