Permit HVAC 708 Cavalla Rd 2013 CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH,FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 13-00002063 Date 1/29/13
Property Address . . . . . . 708 CAVALLA RD
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
1 cu 1 ahu
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
KREHEL JOHN TR TROPIC HEATING & AIR
551 LAKE RD 750 MAYPORT RD
PONTE VEDRA BEACH FL 32082230 ATLANTIC BEACH FL 32233
(904) 241-1788
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee . . . . 91 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 7/28/13
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 91 . 00 91 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 95 . 00 95 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph(904) 247-5826 Fax(904) 247-5845
JOB ADDRESS: PERMIT
PROJECT VALUE $ -2- P0<2
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity jj�'- Tons Per Unit 42?-
Heat: Unit Quantity BTU's Per Unit *@0ty Seer Rating
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
ARI# 3YOY5"1
Air Conditioning: Unit Quantity Tons Per Unit —7- REQUIRED
Heat: Unit Quantity BTU's Per Unit Seer Rating /
Duct Systems: Total CFM REQUIRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty_ Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Reffigerator Condenser BTU's
#Water Heaters Solar Collection Systems
Tanks(gallons)
Wells
OTHER:
Pernitt becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
this application and know the same to be true and correcL All provisions of laws and ordinances governing this work will be complied with whether specified
or not. The permit does not give authority to Violate the p: visions of any other state or local law regulation construction or the performance of consftuction.
�v
Property Owners Name Phone Number
Mechanical Company- Office Phone,-2 4 1-�-WFax-O 4f 1--01(71.
Co. Address: 0 City �- I't StateR ZiD'124'11
License Holder(Print): State C'ertification/Registration#Ce)c0s;Z 4,1)
Notarized Signature ofLicense Holder
KAREN E.PANTFOEDER Sworn n-lqbq-ribpd before me this dav of C-t a !�j 20
(VNOTARY PUBLIC Signature of Notary Public724�,�L
STATE OF FLORIDA
Comm#EE064448
Explres 3/4/2015
it "IMP,
NEAl C E RT I F I E Dr.
www.ahridirector
Certificate of Product Ratino.%,
AHRI Certified Reference Number: 3804517 Date: 1/28/2013
Product: Split System: Air-Cooled Condensing Unit, Coil with Blower
Outdoor Unit Model Number: 11 3AN(A,W)024-D
Indoor Unit Model Number: FB4CNF024
Manufacturer: BRYANT HEATING AND COOLING SYSTEMS
Trade/Brand name: LEGACY RNC 13 PURON AC
Manufacturer responsible for the rating of this system combination is BRYANT HEATING AND COOLING
SYSTEMS
Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third
party testing:
Cooling Capacity(Btuh)-. 22800
EER Rating (Cooling): 11.00
SEER Rating (Cooling): 13.50
Ratings followed by an asterisk J*)indicate a voluntary rerate of previously published data.unless accompaniedwth a WAS;which indicates an involuntary rerate.
DISCLAIMER
AHRI does not endorse the ptoduct(s)listed on this Certificate and makes no representations.wartanties or guarantees as to,and assumes no responsibifityfor,
the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance ofthe product(s),or the
unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at ahridirectory.org,
TERMS AND CONDITIONS
This Certificate and its contents are proprietary products of AHRL This Certificate shall only be used for individual,personal and confidential reference purposes.
The contents ofthis Certificate may not,in whole or in part,lye reproduced;copied;disseminated;entered into a computer database:or otherwise utilized,in any
form or manner or by any means,except for the user's individual,personal and confidential reference.
CERTIFICATE VERIFICATION
The information for the model cited on this certificate can be verifiedat Air-Conditioning,Heating,
click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on ANOW ON ILI and Refrigerafion Institute
which the certificate was issued,which is listed above,and the Certificate No.,which is listed below.
@2012 Air-Conditioning,Heating, and Refrigeration Institute CERTIFICATE NO.: 130038819324857030
Job: Krehel
Project Summary Date: 1/28/2013
Entire House By:
AL
Project Information
For: John Krehel,Tropic Heating&Air Conditioning, Inc.
708 Cavalla Rd..,Atlantic Beach, FL 32233
Phone: 904-241-1788 Fax:904-241-2172
Email:Tropicac@msn.com
Notes:
Design Information
NOW
Weather: Jacksonville/Craig,FL, US
Winter Design Conditions Summer Design Conditions
Outside db 35 'F Outside db 91 oF
Inside db 70 'F Inside db 75 'F
Design TD 35 'F Design TD 16 *F
Daily range M
Relative humidity 50 %
Moisture difference 53 grAb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 15951 Bfuh Structure 13435 B�u`
Ducts 2619 Btuh Ducts 2377 BtN
Central vent(0 dm) 0 Btuh Central vent(0 dm) 0 Btuh
Hurnidification 0 Btuh Blower 0 Btuh
Pi:)ina 0 Btuh
Equipment load 18570 Btuh Use manufacturer's data V
Rate/swing multiplier i.00
Infiltration Equipment sensible load 15 812) Btuh
1 --A
S,i, ion lul-ViN Anvef age
Fireplaces 0 Structure 1 i�97 Btuh
Ducts 645 Stuh
Heatina Cooling Central vent(0 eft.n.) fl R1
Rih
Arpa M'l 10,86 1 08B Enuipment latpnt InRo
8 7 CA A
I V4
Air t�hangp EnUip-mPnt total Inarl F:�4;
�s/hour 045 21
Equiv A_VF(cfm) 65 33 R6%'total capacity nt n_70-SHR I�9 � !i
40
T ade
Trade rVa I r
AH,Rt ref
ni:4
Hpptino minut 0 MRttih Sensibl
e confinn
Tt,v!1pew ahn E!I is-st, vul-Im 19 C1 Rtuh
)N r flow factor
0.039 cmilb-tuh Air fivN factor 0.04 5 an—tul
E�_
+ wrightsoft,
N
job: Kre-hel
Bw
Er Y tif re H e-u se
Project Information
i,none: vu4-241-Vd8 Fax:9U4-Z41-2172
Email:Tropicac@msn.com
iL Design Conditions
n d n r,r Heating COO!'=
nevduun 43 ft LASIVI ILI I, r-) JO
Latitude: 30"N Relative humidity 30 _50-
UUM100r, Heating Cooling INAMTwre d&,'Ter��ce(ar/lb! 6-4 1-1 M
tn- n.n-
-7
Wet bulb('F) 77 Construclion quality Average
%Mnd speedimph', Fircolaces
Heating
F 3-1 A-C
a.S
azi -14
I n g 'Ia7 -56 17.01 VAS
Doors L) 1_61
60-
edwigs I f-A 3
8.6 4699 1 2r"
1 infiltration 1 16 , "14-01 1
1341
DUM 2619' 1441
�Iir-Pg -,I --
Humidficabon
0.
V n 1 61 am3s
e,flation
I A
loag i
-A -1 1
"int; A A ZiZ 4 A A4
Doors f-0 1 22 4
4,1 1-51
Room
I Infiltration i 041 5971 3 1
- 61-S
internal --ams
7 UA01;
Latel-lt U Ooflna"Gad 22141 Btuh
41--.
wrightsaft, 2ni'A-j-.7rL,i�r Aq=,A
Job: Krehel
Component Constructions Date: 1128/2013
Entire House By:
UK"A C-11"syft-
AL
Project Information
For: John Krehel,Tropic Heating&Air Conditioning, Inc.
708 Cavalla Rd-Atlantic Beach, FL 32233
Phone: 904-241-1788 Fax:904-241-2172
Email�Tropicac@msn.com
Design Conditions
Location: Indoor: Heating Coolinr
Jacksonville/Craig,FL,US Indoor temperature('F) 70 75
Elevation: 43 ft Design TD(oF) 35 16
Latitude: 30*N Relative humidity(%) 30 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 8.4 52.8
Dry bul b('F) 35 91 Infiltration:
Daily range('F) - 17 M Method Simplified
Wetbulb('F) - 77 Construction quality Average
Wind speed(mph) 15.0 T5 Fireplaces 0
Construction descriptions Or Area U-value Insul R Mg HTM Loss Clg HTM Gain
ff BW/IF-'F fl2_*F/Bkjh Bkjhtr Btjh Bbliff Btuh
Walls
12B-0sw.Frrn wall,vnl ext,r-1 I cav ins,1/2'gypsurn board int n 199 0.097 11.0 3.36 668 2.61 519
fnsh,2x4*wood frm e 489 0.097 11,0 3.36 1641 2.61 1276
S 231 0.097 11.0 3.36 775 2.61 603
1 489 0.097 11.0 3.36 1641 2.61 1276
an 1408 OM7 11.0 336 4725 2.61 3674
Partitions
(none)
Windows
1 D-c2ow:2 glazing,cir otdr,air gas,wd frm mat,dr innr,114"gap, n 25 0.570 0 19.7 493 17.1 427
1/8"thk;50%binds 45*,light a 55 0.570 0 19.7 1085 50.6 2783
s 25 0.570 0 19.7 493 20.9 522
W 55 0.570 0 19.7 1085 50�6 2783
all 160 0.570 0 19.7 3156 40.7 6514
Doors
11 EO:Door,wd sc type,wd strm n 32 0.260 0 9.00 289 7.62 244
Ceilings
16C-30al:Attic ceiling,asphalt shingles roof mat,r-30 ceil ins,1/2" 544 0.032 30.0 1.11 602 1.37 745
gypsum board int fnsh
Floors
22A-cph:Bg floor,heavy damp soil,on grade depth,carpet fir fnsh 100 1.358 0 47.0 4699 0 0
WrighftOft' Rght-S.t.0 Umersal 2012 12.1.05 Right AD WNW 2013-Jan-28 12:45:58
Page I
ACCK C:%WNDOWSkTEMPWistnVX56ebOI07-ad75-41334M25-8748cg7cD472.rup Cale=MJ8 Fmnt Dow faoes: N
Right-J@ Worksheet Job: Krehel
am Entire House Date: 1/28/2013
By:
AL
1 Roo na Entire Hou First Floor
2 Exposed watt 200.0 It 1000 ft
3 Room height 8,0 ft d 8.0 It heat/cool
4 Room dimensii ns 1088 0 ft2 544,0 W160 x 34,0 ft
5 Room area
I I I I I I
Ty Construction U-value,, Or I ( HTM Area (ft) I Load Area Load
number (Btuh/ftl- F) Btuh/ft) or penmfett2e)r (Btu h) or perimfett'e)r (ft) (Btu h)
I i Heat I Cool Gross I NIPIS Heat Cool G r-S NIP/S Heat Cool
6 128-0sw 0,097 n 336 261 256 199 668 519 128 83 280 2118
10-C2 0.570 n 19,72 17.07 25 0 493 427 13 0 247 2 3
IIED 0260 n 9.00 7.62 32 32 289 244 32 32 289 244
2B-0sw 0.097 e 336 261 5" 489 1641 1276 272 245 821 638
11 VLI ,D-c2ow 0570 e 19.72 5060 55 0 1085 2783 28 0 542 1391
2B-0svv 0097 5 3,36 2,61 256 231 775 603 128 116 388 301
1 11 D-c2ow 0570 s 1972 20M 25 0 493 522 13 0 247 261
12B-Gsw 0097 w 336 261 544 489 1641 1276 272 245 821 638
t--G 1 D-c2ow 0570 w 1972 5060 55 0 1085 2783 28 0 542 1391
C 16C-3Gal 0032 I'll 1�37 544 544 602 745 0 0 0 0
F 22A-cph 1,358 46.99 0.00 544 100 4699 0 544 100 4699 0
61 c)AED excur on 01
Envelope loss/gain 1 134701 111781 1 1 8874 1
12 a) Infiltration 2481 597 1240 299
b) Room ventilation 0 0 0 0
13 Internal gains. Occupants @ 230 2 460 2 460
Applianceslother 1200 1200
Subtotal(lines 6 to 13) 15951 13435 10114 7255
Less external 11 ad 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 15951 13435 10114 7255
15 Duct loads 16% 18% 2619 2377 16% 18% 1661 1284
Total room bad 1115701 1511121 1 1 117751 8539 1
Air required(cfm) 719 719 4561 3881
Calculations approved by ACCA to meet all requirements of Manual J.8th Ed.
414- VVrii4gfttnC3-f`t. 2013-Jan-28 12:45:58
Rig ht-Su rted!)U niv ersal 2012 12 1 05 Right J11)Mobile Page 1
C.%\AANDOWS\TEMPk�tmp\56eb9M7-ad75-Al33-8a25-6748cg7cG472 rup Catc,=MJ8 Front Ooor faces N
Right-J@ Worksheet Job: Krehel
Date: 1128/2013
Entire House By:
AL
1 Ro m name Second Floor
2 Exposed wall 100,0 It
3 Room height 8.0 ft heat/cool
4 Room d,mens ns 16,0 x 34,0 ft
5 Room area 544,0 ft'
I I I I I I
Ty I Construction U-value,) Or HTM Area If t2 I Load) Ar a Load
number (Btuh/ftl- F) (13tuh/ftl or perimeter (Btuh or perimeter
Heat Cool Gross N/P/S Heat C:--:,:j
6 V[ 12B-Osw 0097 n 3,36 2.61 128 116 388 301
I D-c2ow 0,570 n 1972 1707 13 0 247 213
IIED 0�260 n 900 762 0 0 0 0
VL—G1213-0sw 0,097 e 3,36 2.81 272 245 821 638
1 D-c2ow 0.570 e 19.72 SOM 28 0 542 1391
12B-osvv 0.097 s 3.36 2.61 128 116 388 3011
t--G 1 D-c2ow 0,570 s 19.72 20,88 13 0 247 26
I 2B-0sw 0097 w 3�36 2,81 272 245 821 638
1 D-c2ow 0570 w 1972 5060 28 0 542 1391
C 16C-30al 0.032 1 11 1,37 544 544 602 745
F 22A-cph 1.358 4699 000 0 0 0 0
1 61 c)AED excur ion 01
Envelope lossJgain 4597 58811
12 a) Infiltration 1240 299
b) Room ventilation 0 0
13 Internal gains. Occupants @ 230 0 0
Appliancestother 0
Subtotal(lines 6 to 13) 5837 6180
Less external I d 0 0
Less transfer 0 0
Redistribution 0 0
14 Subtotal 5837 6180
15 Duct loads 16% 18% 958 1093
Total room load 13791-1 7271-
Air required(cfm) 1 1 263 3311
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2013-Jan-28 12 45 58
4+1- vvrid4ht-sc�ft. Right-SuiteOD Universal2012 12 1�05 Right JIDMobile Page 2
C�WNDOWS\TEMP�vvstmpX56eb9tO7-ad75-4133-8a25-6748c97cO472 rup Calc=MJ8 Front Door faces. N
Job: Krehel
AED Assessment Date: 1/28/2013
Entire House ay:
AL
Project Information
For: John Krehel,Tropic Heating&Air Conditioning,Inc.
708 Cavalla Rd—Atlantic Beach, FL 32233
Phone: 904-241-1788 Fax: 904-241-2172
Email:Tropicac@msn.com
Design Conditions
Location: Indoor: Heating Cooling
Jacksonville/Craig, FL, US Indoor temperature ff) 70 75
Elevation: 43 ft Design TD(*F) 35 16
Latitude: 30*N Relative humidity(%) 30 50
Outdoor: Heating Cooling Moisture difference(grAb) 8.4 52.8
Dry bul b(*F) 35 91 Infiltration:
Daily range(oF) - 17 M
Wetbulb(-F) - 77
\Mnd speed(mph) 15.0 7.5
Test for Adequate Exposure Diversity
Hourly Glazing Load
9,OOE-
8,OOE-
7,OOE-
6,OOC
5,OOC-
4,OOC-
3,OOC
2,OOC-
1,00c-
0
8 9 10 11 12 13 14 15 16 17 18 19 20
Hour of Day
Houiy Amage AEDliffit
Maximum hourly glazing load exceeds average by 23.5%.
House has adequate exposure diversity (AED), based on AED limit of 30%.
AED excursion: 0 Btuh
wrightsoft 2013-Jan-28 12:45:58
Right-Sude@ Universal 2012 12.1.05 Right AD Mobile Page 1
)C,C� C:IWINDC)WSkTEMPW.MVZ6.bGM7-ad75-4133-8a25-6748cg7cD472.rup Caic=lVU8 Front Door faces: N