Loading...
Permit HVAC 708 Cavalla Rd 2013 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00002063 Date 1/29/13 Property Address . . . . . . 708 CAVALLA RD Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ KREHEL JOHN TR TROPIC HEATING & AIR 551 LAKE RD 750 MAYPORT RD PONTE VEDRA BEACH FL 32082230 ATLANTIC BEACH FL 32233 (904) 241-1788 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 91 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 7/28/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 91 . 00 91 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 95 . 00 95 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax(904) 247-5845 JOB ADDRESS: PERMIT PROJECT VALUE $ -2- P0<2 NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity jj�'- Tons Per Unit 42?- Heat: Unit Quantity BTU's Per Unit *@0ty Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION ARI# 3YOY5"1 Air Conditioning: Unit Quantity Tons Per Unit —7- REQUIRED Heat: Unit Quantity BTU's Per Unit Seer Rating / Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty_ Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Reffigerator Condenser BTU's #Water Heaters Solar Collection Systems Tanks(gallons) Wells OTHER: Pernitt becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correcL All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to Violate the p: visions of any other state or local law regulation construction or the performance of consftuction. �v Property Owners Name Phone Number Mechanical Company- Office Phone,-2 4 1-�-WFax-O 4f 1--01(71. Co. Address: 0 City �- I't StateR ZiD'124'11 License Holder(Print): State C'ertification/Registration#Ce)c0s;Z 4,1) Notarized Signature ofLicense Holder KAREN E.PANTFOEDER Sworn n-lqbq-ribpd before me this dav of C-t a !�j 20 (VNOTARY PUBLIC Signature of Notary Public724�,�L STATE OF FLORIDA Comm#EE064448 Explres 3/4/2015 it "IMP, NEAl C E RT I F I E Dr. www.ahridirector Certificate of Product Ratino.%, AHRI Certified Reference Number: 3804517 Date: 1/28/2013 Product: Split System: Air-Cooled Condensing Unit, Coil with Blower Outdoor Unit Model Number: 11 3AN(A,W)024-D Indoor Unit Model Number: FB4CNF024 Manufacturer: BRYANT HEATING AND COOLING SYSTEMS Trade/Brand name: LEGACY RNC 13 PURON AC Manufacturer responsible for the rating of this system combination is BRYANT HEATING AND COOLING SYSTEMS Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity(Btuh)-. 22800 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.50 Ratings followed by an asterisk J*)indicate a voluntary rerate of previously published data.unless accompaniedwth a WAS;which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the ptoduct(s)listed on this Certificate and makes no representations.wartanties or guarantees as to,and assumes no responsibifityfor, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance ofthe product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at ahridirectory.org, TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRL This Certificate shall only be used for individual,personal and confidential reference purposes. The contents ofthis Certificate may not,in whole or in part,lye reproduced;copied;disseminated;entered into a computer database:or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verifiedat Air-Conditioning,Heating, click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on ANOW ON ILI and Refrigerafion Institute which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. @2012 Air-Conditioning,Heating, and Refrigeration Institute CERTIFICATE NO.: 130038819324857030 Job: Krehel Project Summary Date: 1/28/2013 Entire House By: AL Project Information For: John Krehel,Tropic Heating&Air Conditioning, Inc. 708 Cavalla Rd..,Atlantic Beach, FL 32233 Phone: 904-241-1788 Fax:904-241-2172 Email:Tropicac@msn.com Notes: Design Information NOW Weather: Jacksonville/Craig,FL, US Winter Design Conditions Summer Design Conditions Outside db 35 'F Outside db 91 oF Inside db 70 'F Inside db 75 'F Design TD 35 'F Design TD 16 *F Daily range M Relative humidity 50 % Moisture difference 53 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 15951 Bfuh Structure 13435 B�u`­ Ducts 2619 Btuh Ducts 2377 BtN Central vent(0 dm) 0 Btuh Central vent(0 dm) 0 Btuh Hurnidification 0 Btuh Blower 0 Btuh Pi:)ina 0 Btuh Equipment load 18570 Btuh Use manufacturer's data V Rate/swing multiplier i.00 Infiltration Equipment sensible load 15 812) Btuh 1 --A S,i, ion lul-ViN Anvef age Fireplaces 0 Structure 1 i�97 Btuh Ducts 645 Stuh Heatina Cooling Central vent(0 eft.n.) fl R1 Rih Arpa M'l 10,86 1 08B Enuipment latpnt InRo 8 7 CA A I V4 Air t�hangp EnUip-mPnt total Inarl F:�4; �s/hour 045 21 Equiv A_VF(cfm) 65 33 R6%'total capacity nt n_70-SHR I�9 � !i 40 T ade Trade rVa I r AH,Rt ref ni:4 Hpptino minut 0 MRttih Sensibl e confinn Tt,v!1pew ahn E!I is-st, vul-Im 19 C1 Rtuh )N r flow factor 0.039 cmilb-tuh Air fivN factor 0.04 5 an—tul E�_ + wrightsoft, N job: Kre-hel Bw Er Y tif re H e-u se Project Information i­,none: vu4-241-Vd8 Fax:9U4-Z41-2172 Email:Tropicac@msn.com iL Design Conditions n d n r,r Heating COO!'= nevduun 43 ft LASIVI ILI I, r-) JO Latitude: 30"N Relative humidity 30 _50- UUM100r, Heating Cooling INAMTwre d&,'Ter��ce(ar/lb! 6-4 1-1 M tn- n.n- -7 Wet bulb('F) 77 Construclion quality Average %Mnd speedimph', Fircolaces Heating F 3-1 A-C a.S azi -14 I n g 'Ia7 -56 17.01 VAS Doors L) 1_61 60- edwigs I f-A 3 8.6 4699 1 2r" 1 infiltration 1 16 , "14-01 1 1341 DUM 2619' 1441 �Iir-Pg -,I -- Humidficabon 0. V n 1 61 am3s e,flation I A loag i -A -1 1 "int; A A ZiZ 4 A A4 Doors f-0 1 22 4 4,1 1-51 Room I Infiltration i 041 5971 3 1 - 61-S internal --ams 7 UA01; Latel-lt U Ooflna"Gad 22141 Btuh 41--. wrightsaft, 2ni'A-j-.7rL,i�r Aq=,A Job: Krehel Component Constructions Date: 1128/2013 Entire House By: UK"A C-11"syft- AL Project Information For: John Krehel,Tropic Heating&Air Conditioning, Inc. 708 Cavalla Rd-Atlantic Beach, FL 32233 Phone: 904-241-1788 Fax:904-241-2172 Email�Tropicac@msn.com Design Conditions Location: Indoor: Heating Coolinr Jacksonville/Craig,FL,US Indoor temperature('F) 70 75 Elevation: 43 ft Design TD(oF) 35 16 Latitude: 30*N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 8.4 52.8 Dry bul b('F) 35 91 Infiltration: Daily range('F) - 17 M Method Simplified Wetbulb('F) - 77 Construction quality Average Wind speed(mph) 15.0 T5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Mg HTM Loss Clg HTM Gain ff BW/IF-'F fl2_*F/Bkjh Bkjhtr Btjh Bbliff Btuh Walls 12B-0sw.Frrn wall,vnl ext,r-1 I cav ins,1/2'gypsurn board int n 199 0.097 11.0 3.36 668 2.61 519 fnsh,2x4*wood frm e 489 0.097 11,0 3.36 1641 2.61 1276 S 231 0.097 11.0 3.36 775 2.61 603 1 489 0.097 11.0 3.36 1641 2.61 1276 an 1408 OM7 11.0 336 4725 2.61 3674 Partitions (none) Windows 1 D-c2ow:2 glazing,cir otdr,air gas,wd frm mat,dr innr,114"gap, n 25 0.570 0 19.7 493 17.1 427 1/8"thk;50%binds 45*,light a 55 0.570 0 19.7 1085 50.6 2783 s 25 0.570 0 19.7 493 20.9 522 W 55 0.570 0 19.7 1085 50�6 2783 all 160 0.570 0 19.7 3156 40.7 6514 Doors 11 EO:Door,wd sc type,wd strm n 32 0.260 0 9.00 289 7.62 244 Ceilings 16C-30al:Attic ceiling,asphalt shingles roof mat,r-30 ceil ins,1/2" 544 0.032 30.0 1.11 602 1.37 745 gypsum board int fnsh Floors 22A-cph:Bg floor,heavy damp soil,on grade depth,carpet fir fnsh 100 1.358 0 47.0 4699 0 0 WrighftOft' Rght-S.t.0 Umersal 2012 12.1.05 Right AD WNW 2013-Jan-28 12:45:58 Page I ACCK C:%WNDOWSkTEMPWistnVX56ebOI07-ad75-41334M25-8748cg7cD472.rup Cale=MJ8 Fmnt Dow faoes: N Right-J@ Worksheet Job: Krehel am Entire House Date: 1/28/2013 By: AL 1 Roo na Entire Hou First Floor 2 Exposed watt 200.0 It 1000 ft 3 Room height 8,0 ft d 8.0 It heat/cool 4 Room dimensii ns 1088 0 ft2 544,0 W160 x 34,0 ft 5 Room area I I I I I I Ty Construction U-value,, Or I ( HTM Area (ft) I Load Area Load number (Btuh/ftl- F) Btuh/ft) or penmfett2e)r (Btu h) or perimfett'e)r (ft) (Btu h) I i Heat I Cool Gross I NIPIS Heat Cool G r-S NIP/S Heat Cool 6 128-0sw 0,097 n 336 261 256 199 668 519 128 83 280 2118 10-C2 0.570 n 19,72 17.07 25 0 493 427 13 0 247 2 3 IIED 0260 n 9.00 7.62 32 32 289 244 32 32 289 244 2B-0sw 0.097 e 336 261 5" 489 1641 1276 272 245 821 638 11 VLI ,D-c2ow 0570 e 19.72 5060 55 0 1085 2783 28 0 542 1391 2B-0svv 0097 5 3,36 2,61 256 231 775 603 128 116 388 301 1 11 D-c2ow 0570 s 1972 20M 25 0 493 522 13 0 247 261 12B-Gsw 0097 w 336 261 544 489 1641 1276 272 245 821 638 t--G 1 D-c2ow 0570 w 1972 5060 55 0 1085 2783 28 0 542 1391 C 16C-3Gal 0032 I'll 1�37 544 544 602 745 0 0 0 0 F 22A-cph 1,358 46.99 0.00 544 100 4699 0 544 100 4699 0 61 c)AED excur on 01 Envelope loss/gain 1 134701 111781 1 1 8874 1 12 a) Infiltration 2481 597 1240 299 b) Room ventilation 0 0 0 0 13 Internal gains. Occupants @ 230 2 460 2 460 Applianceslother 1200 1200 Subtotal(lines 6 to 13) 15951 13435 10114 7255 Less external 11 ad 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 15951 13435 10114 7255 15 Duct loads 16% 18% 2619 2377 16% 18% 1661 1284 Total room bad 1115701 1511121 1 1 117751 8539 1 Air required(cfm) 719 719 4561 3881 Calculations approved by ACCA to meet all requirements of Manual J.8th Ed. 414- VVrii4gfttnC3-f`t. 2013-Jan-28 12:45:58 Rig ht-Su rted!)U niv ersal 2012 12 1 05 Right J11)Mobile Page 1 C.%\AANDOWS\TEMPk�tmp\56eb9M7-ad75-Al33-8a25-6748cg7cG472 rup Catc,=MJ8 Front Ooor faces N Right-J@ Worksheet Job: Krehel Date: 1128/2013 Entire House By: AL 1 Ro m name Second Floor 2 Exposed wall 100,0 It 3 Room height 8.0 ft heat/cool 4 Room d,mens ns 16,0 x 34,0 ft 5 Room area 544,0 ft' I I I I I I Ty I Construction U-value,) Or HTM Area If t2 I Load) Ar a Load number (Btuh/ftl- F) (13tuh/ftl or perimeter (Btuh or perimeter Heat Cool Gross N/P/S Heat C:--:,:j 6 V[ 12B-Osw 0097 n 3,36 2.61 128 116 388 301 I D-c2ow 0,570 n 1972 1707 13 0 247 213 IIED 0�260 n 900 762 0 0 0 0 VL—G1213-0sw 0,097 e 3,36 2.81 272 245 821 638 1 D-c2ow 0.570 e 19.72 SOM 28 0 542 1391 12B-osvv 0.097 s 3.36 2.61 128 116 388 3011 t--G 1 D-c2ow 0,570 s 19.72 20,88 13 0 247 26 I 2B-0sw 0097 w 3�36 2,81 272 245 821 638 1 D-c2ow 0570 w 1972 5060 28 0 542 1391 C 16C-30al 0.032 1 11 1,37 544 544 602 745 F 22A-cph 1.358 4699 000 0 0 0 0 1 61 c)AED excur ion 01 Envelope lossJgain 4597 58811 12 a) Infiltration 1240 299 b) Room ventilation 0 0 13 Internal gains. Occupants @ 230 0 0 Appliancestother 0 Subtotal(lines 6 to 13) 5837 6180 Less external I d 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 5837 6180 15 Duct loads 16% 18% 958 1093 Total room load 13791-1 7271- Air required(cfm) 1 1 263 3311 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-Jan-28 12 45 58 4+1- vvrid4ht-sc�ft. Right-SuiteOD Universal2012 12 1�05 Right JIDMobile Page 2 C�WNDOWS\TEMP�vvstmpX56eb9tO7-ad75-4133-8a25-6748c97cO472 rup Calc=MJ8 Front Door faces. N Job: Krehel AED Assessment Date: 1/28/2013 Entire House ay: AL Project Information For: John Krehel,Tropic Heating&Air Conditioning,Inc. 708 Cavalla Rd—Atlantic Beach, FL 32233 Phone: 904-241-1788 Fax: 904-241-2172 Email:Tropicac@msn.com Design Conditions Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature ff) 70 75 Elevation: 43 ft Design TD(*F) 35 16 Latitude: 30*N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(grAb) 8.4 52.8 Dry bul b(*F) 35 91 Infiltration: Daily range(oF) - 17 M Wetbulb(-F) - 77 \Mnd speed(mph) 15.0 7.5 Test for Adequate Exposure Diversity Hourly Glazing Load 9,OOE- 8,OOE- 7,OOE- 6,OOC 5,OOC- 4,OOC- 3,OOC 2,OOC- 1,00c- 0 8 9 10 11 12 13 14 15 16 17 18 19 20 Hour of Day Houiy Amage AEDliffit Maximum hourly glazing load exceeds average by 23.5%. House has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh wrightsoft 2013-Jan-28 12:45:58 Right-Sude@ Universal 2012 12.1.05 Right AD Mobile Page 1 )C,C� C:IWINDC)WSkTEMPW.MVZ6.bGM7-ad75-4133-8a25-6748cg7cD472.rup Caic=lVU8 Front Door faces: N