Loading...
350 Garden Ln HVAC 2013 N C BEACH CITY OF ATLANTI 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00002113 Date 2/06/13 Property Address . . . . . . 350 GARDEN LN Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 6300 -------------- ------------------------------------------------------------- Application desc Replace 2 HVAC Systems ----------------------- ----------------------------------------------------- Owner Contractor ------------------------ ------------------------ SAITTA, KENNETH OWNER 3SO GARDEN LANE ATLANTIC BEACH FL 32233 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . REPLACE 2 HVAC SYSTEMS Permit Fee . . . . 135 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date 8/05/13 ----------------------- 2 . 03 Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE STATE MECH DBPR SURCHARGE 2 . 03 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 13S . 00 13S . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 other Fee Total 4 . 06 4 . 06 . 00 . 00 Grand Total 139 . 06 139 . 06 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. M-ECHANICAL PERMIT APPLICATioN CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach,FL 32233 Ph(904)247-5826 Fax(904)247-5845 JoB ADDREss: y)C, PERMrr# PROJECT VALUE$- LOU NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per.Unit Heat: Unit Quantity BTU's Per Unit Seer Rating— Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & BEATING SYSTEM IN QN 'r '31P It A 6 S-3 0 STA R1#�J�� 36, Air Conditioning: Unit Quantity Tons Per Unit REQ Heat Unit Quantity-:4— BTU's Per Unit je,�oo Seer Ratiniz /E Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty_ Automobile Lifts Gas Pipmg Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps Vented Wall Furnaces Refrigerator Condenser BTU's Water Heaters Solar Collection Systems Tanks(gallons) Wells OTHER: ?ermit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read his application and know the same to be true and correcL All provisions of laws and ordinances governing this work will be complied with whether specified )r not The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. I C roperty Owners Name --�4 1 40, PhoneNumber 90Y--2Y1-- 8-7R4 vfechanical Company fa-VLOV6 f, 14,fL Office Phone ��(-31 grFax -Z-H 1-3-)9Y- .o.Address: 3 -S, City ..i)0,14 GeAck Statefi- Zip Acense Holder(Print): State Certification/Registr�on# iotarized Skmature of License HoLder Sworn anlisubscribed before me this day of f--f 201 Notary Public State of Florida gnature of Notary Public... T im L S 0 irnothy Lee Hughes my Comm.s'on EE 1 86278 Exor , /0 01 6 OF My Commission EE 186278 f-Y' , - Expires=04/03/2016 Job: + wrightsoft Project Summary Date: 2/5/13 Entire House By: Brandon Zaharie Donovan Heat & Air 315 6th ave south,Jacksonville Beach,FL 32250 Phone:241-3785 Ernaill brandon@donovanae.com I Del[gets lillfill]lil-litill 0 M� For: Saitta 350 Garden Lane,Atlantic Beach, FL 32233 Notes: Design Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 oF Outside db 95 'F Inside db 68 'F Inside db 75 oF Design TD 29 'F Design TD 20 '17 Daily range L Relative humidity 50 % Moisture difference 53 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 14414 Btuh Structure 14371 Btuh Ducts 4124 Btuh Ducts 5926 Btuh Central vent (13 cfm) 409 Btuh Central vent (13 cfm) 282 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 18948 Btuh Use manufacturer's data n Rate/swing multiplier 1.00 Infiltration Equipment sensible load 20579 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 1921 Btuh Ducts 1295 Btuh Heating Cooling Central vent (13 cfm) 465 Btuh Area(ft') 121 121 Equipment latent load 3680 Btuh Volume(ft') 10962 10962 24258 Btuh Air changes/hour 0.56 0.23 Equipment total load Equiv.AVF (cfm) 102 42 Req- total capacity at 0.70 SHR 2.4 ton Heating Equipment Summary Cooling Equipment Summary Make Tempstar Make Tempstar Trade Trade Model NXH530 Cond NXH530 ARI ref no. 3653116 Coil FVM4X30 ARI ref no. 3653116 15.8 SEER Efficiency 8.7 HSPF Eff iciency Heating input Sensible cooling 20906 Btuh Heating output 29717 Btuh @ 47oF Latent cooling 8960 Btuh Temperature rise 27 'F Total cooling 29866 Btuh Actual air flow 996 cfm Actual air flow 996 cfm Air flow factor 0.054 cfm/Btuh Air flow factor 0.049 cfm/Btuh Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat Load sensible heat ratio 0.85 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. Right-SuiteO Universal 7.1.01 RSU05996 2013-Feb-05 11:20 31 c u.er.\S.jes\Docurnents\Wnght soft HVAC\2.5 TON Calc=MJ8 Orientation=N Page I Job: roject Summary Date: 215/13 wrightsoft P By: Brandon Zaharie Entire House Donovan Heat & Air 315 6th ave south,Jacksonville Beach,FL 32250 Phone:241-3785 Email: brandon@donovanac.corn - Proiect Information For: Saittla 350 Garden Lane, Jacksonville, FL 32233 Notes: Desiqn Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 'F Outside db 95 'F Inside db 68 'F Inside db 75 oF Design TD 29 'F Design TD 20 'F Daily range L Relative humidity 50 % Moisture difference 53 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 13919 Btuh Structure 11729 Btuh Ducts 2799 Btuh Ducts 5690 Btuh Central vent (12 cfm) 370 Btuh Central vent (12 cfm) 255 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh ufacturer's data n Equipment load 17088 Btuh Use man Rate/swing multiplier 1.00 Infiltration Equipment sensible load 17674 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality 1 ( Average 1638 Btuh Fireplaces Average) Structure 973 Btuh Ducts Heatin coolin Central vent (12 cfm) 420 Btuh Area (ft') 1159 11'59 Equipment latent load 3031 Btuh Volume(ft') 10368 10368 Air changes/hour 0.57 0.23 Equipment total load 20706 Btuh Equiv.AVF (cfm) 98 40 Req. total capacity at 0.70 SHR 2.1 ton Heating Equipment Summary Cooling Equipment Summary Make Tempstar Make Tempstar Trade Trade Cond NXH524 Model NXH524 Coil FVM4X24 ARI ref no. 3653095 ARI ref no. 3653095 15.8 SEER Eff iciency 8.5 HSPF Efficiency- Sensible cooling 15747 Btuh Heating input 6749 Btuh Heating output 22384 Btuh @ 47'F Latent cooling 22496 Btuh Temperature rise 27 'F Total cooling 750 cfm Actual air flow 750 cfm Actual air flow 0.043 cfm/Btuh Air flow factor 0.045 cfm/Btuh Air flow factor 0 in H20 0 in H20 Static pressure Static pressure Load sensible heat ratio 0.85 Space thermostat Printout certified by ACCA to meet all requirements of Manual J 8th Ed. 2013-Feb-05 11 22:46 -SuiteO Universal 7.1.01 RSU05996 Page I Right ACCK c:\users\Sates\Documents\Wrightsoft HVAC\2Ton.rup Calc=MJ8 orientation=N