Loading...
93 Kimberly Ct HVAC 2013 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00002148 Date 2/12/13 Property Address . . . . . . 93 KIMBERLY CT Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ DOMIMICK ESMOND LESTER III i & W HEATING AND AIR 1431 RIVERPLACE BLVD #2310 11232 ST.JOHNS IND PKWY STE 4 JACKSONVILLE FL 32207 JACKSONVILLE FL 32246 (904) 764-0040 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 91 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 8/11/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 91 . 00 91 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 95 . 00 95 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, Fl, 32233 Ph (904) 247-5826 Fax (904) 247-5845 JOBADDRESS: PERMIT PROJECT VALUE NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity_ Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating REQUIRED Duct Systems: Total CFM REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit ARI #REQUI Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps Condenser BTU's Vented Wall Furnaces Refrigerator Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: doned for six months.I hereby certify that I have read Permit becomes void if work does not commence within a six month period or work is suspended or aban this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance ofconstr"ction. Property Owners Name ! - -�n� �� Phone NumberU3 A---11N W 6a��T-a X-1 U q jq( c,�'j Mechanical Company ma 0, K Office Phone.-,�— StateC-L---Zij6-2ZkM Co. Address: License Holder(Print # State Certification/Registration Older Notarized Signat ­ff % & 4 — day of tr-e 44 20 6 Sworn and su scribed before me this �"p jgnature of Notary Public e—&n� #EE 176M8 :c3Z ol:;A ST SALES,SERVICE&INSTALLATION SINCE 1966 11232 ST.JOHNS INDUSTRIAL PARKWAY NsuiTE 4.JACKSONVILLE FL 32246 I&W AIAM 904-764-0040 Www.]ANDWHEATINGANDAIR.COM j &W Heating and Air authorizes Brandon Rea to pull a Mechanical Permit with the City of Atlantic Beach for address 93 Kimberly Court Atlantic Beach 32233. Brent Marler-Owner License # CAC1815399 STATE OF FLORIDA COUNTY OF E'�O V a t The foregoing instrument was acknowledged before me this 1-3)tA day of J5ehr&tA%'V 20 13 by 9F-rj)4 fti-ler President of I &W Heating And Air. Signature of Notar SON CZ -v Printed Name Personally Known entification eed Id Type of Identification Produced MET*] Location: Street Address 88 Dewees Ave,, Atlantic Beach, FL 32233 L i atitude, Longitude 30,3375", -8136860 House Square Footage: 1829 sq. ft. Name: Dick Sackette kone: 904-382-1080 Email: Information 15� R .75 ---------- .................... Number of residents 2 .............----....... Ceiling height 9 Wall U-value I R-vallue 0.09111 ------------- Floor U-value I R-value 0.215 .......... (eiling U-value R-value 0.053119 Window U-value 0.5 VYindow SHGF 0.85 ................ ........................... ................................ Moisture grains 53 buctloss % 10 .......... ---------- ------------- Duct gain % 10 --�ooling infiltraction (ACH) 0.6 ............ ---------- Heating infiltration (ACH) 0.8 inter ventilation 0 *mmer ventilation 0 ............................. ............ Oesign Conditions outdoor Heating Cooling 32 93 Dry bulb ( F) Daily range M kelative humidity 50% ....................... Moisture difference 53 ........... indoor Heating Cooling Indoor temperature ( F) 70 75 ............ Design temperature difference(OF) 38 18 � + .............____ I �Hea-tina Loads Ama Btuh % of load Wall 3267 10.2 Floor 8755 27.2 Ceiling 3684 11.4 Windows 5016 15.6 Infiltration 8532 26.5 ............. System Efficiency Loss 2925 9.1 32180 Loads Heating 311,180 BTU!hr r System Efficiency Loss Floor Wall Ceiling Windows Infiltraitioni iCooli _ng Loads Area Btuh % of load Wall 15 4(81 Ceiling 1745 4.2 Windows 23043 55�7 Sensible Infiltration 3031 7.3 Latent Infiltration 5517 13.3 system Efficiency Gain 3488 8.4 internal 2052 5 Sensible People Load 460 1.1 ............. Latent People Load 460 total: 41345 .......... 5ensible load 35361 Latent load 5977 !�H R 0,86 ---------- ------- Capacity at .75 SHR 3.93 Tons Cooling Loads 11-345 BruJif Sensible People Load Latent People Load wall Ceiling Internal Sensible Intiltration i Systern Efficienci Windows Latent Infiltration Fix We r-A W.4 AED Graph 40000 30000 20000 3 10000 C,p 7;)n 0 Ipm 21)m 31)m 4pm Sam 9am I 0a m 11am 12pm ....................... Hourly Loads Average [Equipment selection SyStern equipj,iient selection will be made us;ng tbe f(�)Jjowiny cletived values. Summer Outdoor 93"F mer Wet Bulb 770F ............. 750F *mmer Indoor .................... Summer Design Grains 50% .............. ................... Winter Outdoor 320F Winter Indoor 70OF ................. Sensible Cooling 35,367 Btuh Lotent Cooling 5,977 Btuh Required Cooling Airflow 1,608 CFM Sensible Heating 32,180 Btuh ............. Required Heating Airflow 418 CFM ............ .............. .............._­.__._­___­­­_­­.......... .......... All calculations are based upon approved livac industry standards and procedures,and comply with all local, state and federal code requirements.All computed results are Estimates,Product provided by Energy Design syitems and Idea Tree CERTIFIED,.-, www.ahridirectory.org -A' Certificate of Product Ratings AHRI Certified Reference Number: 3605264 Date: 11/26/2012 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 13PJL48 Indoor Unit Model Number: RHSL-HM4821+RCSL-H*4821 Manufacturer: RHEEM MANUFACTURING COMPANY TradelBrand name: RHEEM 13PJL SERIES Manufacturer responsible for the rating of this system combination is RHEEM MANUFACTURING COMPANY Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity(Btuh): 46500 EER Rating(Cooling): 10.50 SEER Rating(Cooling): 13.00 Heating Capacity(Btuh) @ 47 F: 46000 Region IV HSPF Rating(Heating): 8.50 Heating Capacity(Btuh) @ 17 F: 30600 Ratings followed by an asterisk i*)indicate a voluntary lerale of pfe�jotj�iy ;�Iblisl)ed dala.unless accompanted with a VIA&which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the produc0s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Cortificiate.AHRI expressly disclaims all liability for damages of any kind arising out of the Use or performiance of the product(s),or the unauthorLzed alWabon of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This certificate and its Contentill are proprietary products of AHRI.This CerUfleate shall only be used for individual,personal and confidential reference Purposes. The Cor"nu of this Certificate rnay not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utifted,in any form or manner or by any means.except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION 11111 Air-Conditioning,Heating, The information for the model cited on this Certificate can be verified at www.ahridirectory.org, As "Ic click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on 0%1 On iLl and Refrigeration Institute which the cartificalta was issued,which is listed above,and the Cortilficate No.,which is listed below. 0c2012 Air-Conditioning,Heating,and Refrigeration Institute CERTIFICATE NO.: 129984313142509101_