Loading...
Permit HVAC 1668 N Linkside Ct 2013 CITY OF ATLANTIC BEACH s 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 �Ji3 i Application Number . . . . . 13-00002145 Date 2/12/13 Property Address . . . . . . 1668 N LINKSIDE CT Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 3900 -------------------------------------------------- -------------------------- Application desc REPLACE 1 CU 1 AHU ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ BONELLI, PETER TROPIC HEATING & AIR 1668 LINKSIDE CT N 750 MAYPORT RD ATLANTIC BEACH FL 32233 ATLANTIC BEACH FL 32233 (904) 241-1788 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . REPLACE 1 CU 1 AHU Permit Fee . . . . 95 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 8/11/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 95 . 00 95 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 99 . 00 99 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax(904)G 247-5845 / � � PERMIT# f-3 ' q JOB ADDRESS: rCa4,9 �•K/mss• �Ce G� L.v� PROJECT VALUE $ �✓7 �d� NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct S Y Stems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION .ARI Air(;o itioning: Unit Quantity P tons Per Unit Z S REQ Heat: Knit Quantity /I BTU's Per Unit ✓_.. Seer Rating 15 ZS Duct S stems: Total CFM REQUfh�t FIRE PREVENTION Fire Sp --inkier, System Quantity (Requires 3 sets of plans) rife Ji id—pig.e �,CUa liilli3 ----- t.l1a,[.4uiaw .. `s'i4.w {.il }.sicau.sJ r.;rider-�, auric! vire Main value t Requires 3 sets of plans) Fire H7c se.Cab]nets Ouar,ti v (Requires 3 sets of Plans", ( ^.rrtrn rr i r i ;t it =Et. x° t#lfiri= -- n _ __ !S<_ +;,,. f "'/i�3`ifii 3 Seia Q3i viai)�iE 1 ife Su tofeSsiL'.1 Ciii� l�issifel4Ry l 4f FIRE PL, MISE FI, .NF,01!S: D-4.11, ..+n.l t2'��,+1 n 11+:r �11.:.nm.�hita T i F}a nr i V! VCs4�+.1 1 !i V YCiVV V 4 ESLD t'14 1li.`v��jai[aGi� _�@ tai3iii.iS xi i i Elevators/E-scalat.ors AI .T. OT Fit GAS PIPING t-ii st Exchanger i, iitliui r vi ifistai•%�. -_---.___..___ `� ! po vent Wall Furilac-e-s Reffigerator Condenser BTU,S V1 situ f e3tGi3 soiar Coiitecuon Systems Ta--"%:i(Vuiivii s i sI.. iY3'z�i iJ I OTHER: i'CiTitlt iJCWttt' i'�Jtii ti ViT4Ti iit'F.S IEc]k 3T.Z'.a.-=w §Idilit iZ.� c7lt t3 SrOIk.!S "tt' .tt "iI�h ik'ft1Li .2:i€six Tt1€5F f�L�..L Its£:-.}` �`-..�[.; have CC3LF il- .,n 1,� n. r ._ r. •' _-- i'*i�wr,'is_clns ni luck--,and nrzltnynce�±�ct)-C Viii tU rlli.'R�[t�'}S li�}17���mo}iec}tai.-n Whether _,•:-Li.p}ica - and i noN-,-the same... e ..� ....a _�.. g — or not. The t doles not 9111G authority to violate the Provisions of any other state or it l law It; lta im cultsiructiott fit the poak)giiittii5 e at cor1-11-t-0-1. - __ G z 5-7 _ - ---- ri;l! i'S1�+tG tl,,,,. KAREN E.PANTFOEDER iJ NOTARY PUBLIC ,.._,-- - n. _;;i: %7 .£J....iu:V'01 INVL:tY 1 ,....ill.: -- -- STATE OF FLORIDA - Comm#EE064448 Expires 3/4/2015 This combination qualifies for a Federal Energy Efficiency Tax Credit when placed in service between Feb 17, 2009 and Dec 31, 2013. www.ahridii Certificate of Product Ratings AHRI Certified Reference Number: 3647402 Date: 2/12/2013 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 215BNA030****A Indoor Unit Model Number: FX4DN(B,F)031 Manufacturer: BRYANT HEATING AND COOLING SYSTEMS Trade/Brand name: LEGACY LINE PURON HP Manufacturer responsible for the rating of this system combination is BRYANT HEATING AND COOLING SYSTEMS Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (Btuh): 28800 EER Rating (Cooling): 12.50 SEER Rating (Cooling): 15.25 Heating Capacity(Btuh)@ 47 F: 28200* Region IV HSPF Rating (Heating): 8.50* Heating Capacity(Btuh) @ 17 F: 17000 Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectoryorg. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION The Information forthe model cited on this certificate can be verified at www.ahridirectoryorg, "IMPw Air-Conditioning,Heating, dick on"Verity Certificate"link and enter the AHRI Certified Reference Number and the date on �. On -' and Refrigeration Institute which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. ©2012 Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 130051549459994924 Project Summa Job: Bonelli Pro Summary Date: 2112!2013 Entire House By: Aq • For: Peter Bonelli,Tropic Heating&AirConditioning,lnc. 1668 Linkside Ct. N.,Atlantic Beach,FL 32233 Phone: 904-241-1788 Fax: 904-241-2172 Email:Tropicac@msn.com Notes: Weather: Jacksonville/Craig, FL, US Winter Design Conditions Summer Design Conditions Outside db 35 °F Outside db 91 °F Inside db 70 °F Inside db 75 °F Design TD 35 °F Design TD 16 °F Daily range M Relative humidity 50 % Moisture difference 53 grub Heating Summary Sensible Cooling Equipment Load Sizing Structure 22020 Btuh Structure 16425 Btu Ducts 4506 Btu Ducts 4965 Btu Central vent(0 cfm) 0 Btu Central vent(0 cfm) 0 Btu Humidification 0 Btu Blower 0 Btu Piping 0 Btu Equipment load 26526 Btu Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 21390 Btu Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2095 Btu Ducts 1315 Btu Heating Cooling Central vent(0 cfm) 0 Btu Are a(ft?) 1575 1575 Equipment latent load 3410 Btu Volume(ft') 14175 14175 Air changesfhour 0.38 0.20 Equipment total load 24800 Btu Equiv.AVF (cfm) 90 47 Req.total capacity at 0.70 SHR 2.5 ton Heating Equipment Summary Cooling Equipment Summary M ake nla M ake Trade nia Trade Model nla Cond AHRI ref nla Coil AHRI ref Efficiency n1a Efficiency 0 SEER Heating input 0 MBtuh Sensible cooling 0 Btu Heating output 0 Btu Latent cooling 0 Btu Temperature rise 0 °F Total cooling 0 Btu Actual airflow 912 cfm Actual airflow 912 cfm Air flow factor 0.034 cfn-VBtuh Air flowfactor 0.043 cfn-VBtuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.86 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. K1W t t (ltSl] t2013-Feb-12 05::00 Right-sude@uriversal201212.1.05 Right JO Mobile Pagel C:IMNDOVVSITEMPI�atmpl3$1e38f9-13cb-0134872e 8fc9612G5338.rup Calc=MJ8 Frord Door faces: w Right JCS M o bile Report Job: Bonelli g R Date: 2/122013 } Entire Horse AL Project Information For: Peter Bonelli,Tropic Heating&AirConditioning,lnc. 1668 Linkside Ct.N.,Atlantic Beach,FL 32233 Phone: 904-241-1788 Fax: 904-241-2172 Email: Tropicac@msn.com Design Conditions Loco on: Indoor. Heating Cooling Jacksonville/Craig, FL, US Indoor temperature (°F) 70 75 Elevation: 43 ft Design TD f°F) 35 16 Latitude: 30°N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 8.4 52.8 Dry bul b(°F) 35 91 Infiltration: Dailyrange(°F) - 17 f M ) Method Simplified Wet bulb (°F) - 77 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 Component Btu h/ft2 Btu % of load Walls 3.4 4517 17.0 Glazing 19.7 3008 11.3 USI 1 Doors 13.5 425 1.6 Ceilings 1.7 2670 10.1 a� Floors 5.1 7988 30.1 -� IrfiRrian Infiltration 2.2 3412 12.9 Ducts 4506 17.0 aha Piping 0 0 Ceilings .�' § Humidification 0 0 Floors Ventilation 0 0 Adjustments 0 Total 26526 100.0 Cooling Component Btuhfif Btu % of load Walls 2.6 3512 16.4 Vii rte Glans Glazing 44.2 6744 31 .5 Doors 11.4 360 1.7 Ceilings 2.1 3303 15.4 Des Floors 0 0 0 Infiltration 0.6 846 4.0 Ducts 4965 23.2 t Ventilation 0 0 , Internal gains 1660 7.8 aadng i' Irfiltratim Blower 0 0 Adjustments 0 Ceilings Total 21390 100.0 Qher Latent Cooling Load =3410 Btuh Overall U-value=0.115 Btuh/ft2°F Data entries checked. w t„ h1 gof k2013-Feb-12 05:22:00 Right-Suite®Uriversal 2012 121.05 Right J@ Mobile Pagel -` " C:IMNDOwS%TEMPtvdmp%38le3819-13cbs1134872e-8fc9bl2o5338.rup Calc=MJ8 FrordDoorfaoes: w Right-J@ Worksheet Job: Bonelli Entire House Bate: 21122013 By. AL 1 Room name Entire House First Floor 2 Exposed wall 170A It 1700 ft llcool 3 Room height 9.0 ft d 9.0 ft hea 4 Room dimensions =1.0 x 1575.0 ft ft 5 Room area 1575.0 ft' 1575.0 ft Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Eltuhtft'-'F) (Btuhfft� or perimeter (ft) (Htuh) or perimeter (ft) (Btuh) Heat Cool Gross NRS Heat Cool Gross NNS Heat Cool 6 V[::t 128-Osw 0.097 n 3.36 2.61 360 293 982 764 360 293 982 764 1 D-c20 w 0.570 n 19.72 20.91 36 0 707 749 36 0 707 749 11 DO 0.390 n 13.49 11.43 32 32 425 360 32 32 425 360 Vtf 128-0sw 0.097 a 3.36 2.61 405 364 1222 950 405 364 1222 950 11 _,G 1 D-c2ow 0.570 a 19.72 63.01 41 0 805 2573 41 0 805 2573 4Q! 128-Osw 0.097 s 3.36 2.61 360 324 1088 846 360 324 1088 846 �--G 1 D-c2ow 0.570 s 19.72 25.16 36 0 707 901 36 0 707 901 12B-0sw 0.097 w 3.36 2.61 405 365 1225 952 405 365 1225 952 1 D-c2ow 0.570 w 19.72 63.01 40 0 789 2520 40 0 789 2520 C 16C-1991 0.049 1.70 2.10 1575 1575 2670 3303 1575 1575 2670 3303 F 22A.mh 1.358 46.99 0.00 1575 170 7988 0 1575 170 7988 0 6 c)AED e)cursion 1 0 1 0 Envelope loss(gain 18608 1 13919 1 1 18608 13919 12 a) Infiltration 3412 846 3412 846 b) Room ventilation 0 0 0 0 13 Internal gains Occupants @ 230 2 460 2 460 ApplianoesJather 1200 1200 Subtotal(Ii nes 6 to 13) 22027 16425 22020 16425 Less external Ioad 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 22020 16425 22020 16425 15 Duct loads 20% 30% 4506 4965 20% 30% 4506 4965 Total room load 26526 21390 26526 21390 Air required(cfm) 1 1 912 9121 1 1 9121 912 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-Feb4 2 05:22:00 wor►gtls+k+;'atY Right-Sufte@Uriversal201212.1.05 Right J@ Mobile Pagel Y,>ID. C:VNNDOVv51TEMP%vdmp1381e381943cb-4134-872e8fc9b12c5338.rup Calc=MJ8 Front Door faces:W Component Constructions Job: Bonelli P Date: 2/122013 Y Entire House By: �,ry:•s��ui�t a �;�Mt Project • • For: Peter Bonelli,Tropic Heating&AirConditioning,lnc. 1668 Linkside Ct. N.,Atlantic Beach,FL 32233 Phone: 904-241-1788 Fax: 904-241-2172 Email: Tropicac@msn.com Design Conditions�""V Loca on• Indoor. Heating Cooling Jacksonville/Craig, FL, US Indoor temperature ('F) 70 75 Elevation: 43 ft Design TD(°F) 35 16 Latitude: 30°N Relative humidity(°/o) 30 50 Outdoor: Heating Cooling Moisture difference (grilb) 8.4 52.8 Dry bul b(°F) 35 91 Infiltration: Dailyrange(°F) - 17 ( M ) Method Simplified VVet bulb(°F) - 77 Construction quality Average VUlnd speed(mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain t" Bthjr-"F C-"FRowh Bnhtr Ruh Whir Ruh Walls 12B-Osw:Frm wall,vnl ext,r-11 cav ins,112"gypsum board int n 293 0.097 11.0 3.36 982 2.61 764 fnsh,2"x4"wood frm e 364 0.097 11.0 3.36 1222 2.61 950 s 324 0.097 11.0 3.36 1088 2.61 846 w 365 0.097 11.0 3.36 1225 2.61 952 all 1346 0.097 11.0 3.36 4517 2.61 3512 Partitions (none) Windows 1 D-clow:2 glazing,clr outr,air gas,wd frm mat,clr innr, 114" gap, n 36 0.570 0 19.7 707 20.9 749 118"thk a 41 0.570 0 19.7 805 63.0 2573 s 36 0.570 0 19.7 707 25.2 901 w 40 0.570 0 19.7 789 63.0 2520 all 153 0.570 0 19.7 3008 44.2 6744 Doors 11 DO:Door,wd sc type n 32 0.390 0 13.5 425 11.4 360 Ceilings 16C-19al:Attic ceiling,asphalt shingles roof mat,r-19 ceil ins,1I2" 1575 0.049 19.0 1.70 2670 2.10 3303 gypsum board int fnsh Floors 22A-cph:Bg floor,heavy damp soil,on grade depth,carpet flr fnsh 170 1.358 0 47.0 7988 0 0 2013-Feb-12 05:22:01 _ - vu YiiyhtSt3ft Right-suite®U niversal 2012 12.1.05 Right J®Mobile Pagel °T C:WNDOWS%TEMPtvydmpl38le381943cb-4134-872e-8fc9bl2c5338.rup Calc=MJ8 Front Door faces:W AED Assessment Job: Bonelli Date: 2/12/2013 Entire House By: ai. For: Peter Bonelli,Tropic Heating&AirConditioning,lnc. 1668 Linkside Ct.N.,Atlantic Beach, FL 32233 Phone: 904-241-1788 Fax: 904-241-2172 Email:Tropicac@msn.com Design • • Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature (°F) 70 75 Elevation: 43 ft Design TD(°F) 35 16 Latitude: 30°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 8.4 52.8 Dry bul b(°F) 35 91 Infiltration: Dailyrange(°F) - 17 ( M ) Vet bulb('F) - 77 Wind speed(mph) 15.0 7.5 Hourly Glazing Load 9'OOC-- 8,Oo 7,00 _ 6,Oo 4,00 3,00 2,00 1,00 0 8 9 10 11 12 13 14 15 16 17 18 19 20 Hour of Day Homy Aerage PED lin it Maximum hourly glazing load exceeds average by 19.1%. House has adequate exposure diversity(AED), based on AED limit of 30%. AED excursion: 0 Btuh w rt h tSOft2013-Feb-12 05:22:01 Right-Suite®1-1rrversa1201212.1.05 Right J@ Mobile Pagel ._;• C:WNDOWS%TEMPwdmp1381 e38T3-13cb4l34S72e-8fcgb12c5338.rup Calc=MJ8 Frorh Door faces:W