Permit HVAC 792 Aquatic Dr 2013 CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
j �. ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 13-00002180 Date 2/20/13
Property Address . . . . . . 792 AQUATIC DR
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
1 cu 1 ahu
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
MCCORMICK, CHERYL ONE HOUR AIR
792 AQUATIC DRIVE 1015 ATLANTIC BLVD #249
ATLANTIC BEACH FL 32233 ATLANTIC BEACH FL 32233
(904) 222-8482
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee . . . . 91 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 8/19/13
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 91 . 00 91 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 95 . 00 95 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph (904) 247-5826 Fax (904) 247-5845 /l
JOB ADDRESS: 1 C PERMIT# 21
PROJECT VALUE $ �! ARI# 38 2 -70
REQUIRED
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit QuantityTons Per Unit �Z
Heat: Unit Quantity BTU's Per Unit 2 L41 _ Seer Rating
Duct Systems: Total CFM REQUIRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
# Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER:
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified
or not. The permit does not give authority to violate the provisixr�
y other state or local law regulation construction or the performance of construction.
Property Owners Name C al CO'c_M I C I Phone Number ?,Y7- 0372
Mechanical Company ffice Phone�L) - 0� Fax2 2 SS Z6
Co. Address: MCit "- �ca State Zip
c'322 5
License Holder(Print): ( - Q C ifi tion/Registration htl [[, yZ�
Notarized Signature of License Holder
i�
SHIRLEY LL14,
efore me this Z L day
MV COMMISSION
`I 'r EXPIRES:Febru4 gnature of Notary PublicBonded Thru Notary Pters
wrightsoft Project Summar Job: 121789
Summary Date: 2/20/2013
Entire House By: CRAIG EDDY
ONE HOUR AIR
1198 MAYPORT RD#1,ATLANTIC BEACH,FL 32233 Phone:904-241-3107 Fax 904-247-5526 License:CAC1814420
Project • •
For: CHERYL MCCORMICK
792 AQUATIC DR, ATLANTIC BEACH, FL 32233
Phone: 904-247-0373
Notes:
Design Information
Weather: Jacksonville/Craig, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 35 °F Outside db 91 °F
Inside db 70 °F Inside db 75 °F
Design TD 35 °F Design TD 16 °F
Daily range M
Relative humidity 50 %
Moisture difference 53 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 18538 Btuh Structure 17413 Btuh
Ducts 0 Btuh Ducts 0 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 18538 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 17413 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 2309 Btuh
Ducts 0 Btuh
Heating Cooling Central vent(0 cfm) 0 Btuh
Area(ft2) 1008 1008 Equipment latent load 2309 Btuh
Volume(ft3) 8064 8064
Air changes/hour 0.45 0.23 Equipment total load 19721 Btuh
Equiv.AVF (cfm) 60 31 Req.total capacity at 0.74 SHR 2.0 ton
Heating Equipment Summary Cooling Equipment Summary
Make GOODMAN Make GOODMAN
Trade AMANA DISTINCTIONS Trade AMANA DISTINCTIONS
Model GSZ130241 Cond GSZ130241
AHRI ref 3842470 Coil AWUF2405
AHRI ref 3842470
Efficiency 0 HSPF Efficiency 13 SEER
Heating input Sensible cooling 16895 Btuh
Heating output 0 Btuh @ 47°F Latent cooling 5905 Btuh
Temperature rise 0 °F Total cooling 22800 Btuh
Actual air flow 0 cfm Actual air flow 793 cfm
Air flow factor 0 cfm/Btuh Air flow factor 0.046 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.88
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
w�I hYSOft 2013-Feb-2009:03:06
g Right-SuiteOO Universal 2012 12.1.05 Right J®Mobile Page 1
C:\WINDOWS\TEMP\wstmp\3a6a8025-ba28-433e-8e3a-9bOeOd612af7.rup Calc=MJ8 Front Door faces: N