Permit HVAC 1886 Seminole Rd 2013 CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
oil
Application Number . . . . . 13-00002213 Date 2/22/13
Property Address . . . . . . 1886 SEMINOLE RD
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
1 cu 1 ahu
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
WATSON REALTY CORPORATION WATSON HEATING AND AIR
7821 DEERCREEK CLUB DR 4456 SUNBEAM RD
JACKSONVILLE FL 32256 JACKSONVILLE FL 32257
(904) 899-6830
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee . . . . 103 . 00 Plan Check Fee . 00
Issue Date . . . . valuation . . . . 0
Expiration Date . . 8/21/13
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 103 . 00 103 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 107 . 00 107 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALI, CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph(904) 247-5826 Fax (904) 247-5845
JOB ADDRESS: sern A)o e o PERMIT
PROJECT VALUE $ 41 &(Z)O C>-j ARI# -5(0 6 9
REQUIRED
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity W Tons Per Unit 5=
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit 3 .5, 1 0 CD
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
#Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER: C4-L006C 00-F 0J/ "e,9-tCZJF- F40 <� FIZ06� TS7-0-1 f1F-P-fJf/?,G/ Cap&
WckAJ (- C603 Fuonf SwiT-C4 DucT- QEeT(RCz)-j)C),)
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified
or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
Property Owners Name W�WrScf-J REO��, COP-0, PhoneNumber 596--'�-000
Mechanical Company- WLJISO,�J <1� 401112- Office Phone 8919 6�O Fax A" (o 8 2,7
Co. Address: 44f(o SJOSEbryi k S 7C-- W 0 City JZCk-3 p rij( I f(--e State ft- zip 3 2-z s-7
License Holder (Print): P8 j c M �,-06/u-a State Certification/Registration Co C (8/ (0 28(�L
Notarized ig gatme o License I-Iolder
G
SHIRLEYL. e e this d 20
myc RAI W,57706,r
OMMISSION D
,EXPIRES:February M,2014
't, nded Thru Notary Public higaiA e u
of Notary P I
CERTIFIEDT"
www.ahrid i rectory.or g
Certificate of Product Ratings
AHRI Certified Reference Number: 5065909 Date: 2/22/2013
Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source
Outdoor Unit Model Number: 4TWB3042B1
Indoor Unit Model Number: GAT2AOB42S31+TDR
Manufacturer: AMERICAN STANDARD, INC.
Trade/Brand name: AMERICAN STANDARD 13
Manufacturer responsible for the rating of this system rombination is AMERICAN STANDARD, INC.
Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third
party testing:
Cooling Capacity (Btuh): 41000
EER Rating (Cooling): 11.00
SEER Rating (Cooling): 13.00
Heating Capacity(Btuh) @ 47 F 40500
Region IV HSPF Rating (Heating): 8.20
Heating Capacity(Btuh) @ 17 F: 26600
Ratings followed by an asterisk(*)indicate a voluntary rerate ot previously published data,unless accompanied War a WAS,which tndicales air involuntary rerate.
DISCLAIMER
AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for,
the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance ofthe product(s),orthe
unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory atwww.ahridirectory.org.
TERMS AND CONDITIONS
This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.
The contents of this Certificate may not,in whole or in part be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any
form or manner or by any means,except for the user's individual,personal and confidential reference.
CERTIFICATE VERIFICATION
The information forthe model cited on this certificate can be verified atwww.ahridirectory.org, "Cap, Air-Conditioning,Heating,
clickon"Verify Certificate"linkand entertheAHRI Certified Reference Number and the date on
which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. Ono an SI and Refrigeration Institute
@2012 Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO.: 130060134990105460
C
Residential System Sizing Calculation
Summary
Pi=1/ALTj' GCP-P Proiect Title:
�;eminole Rd ),?P
,(.Seminole
Duval, FL 32233-
Location for weather data: Jacksonville, FL - Defaults: Latitude(30.5) Altitude(30 ft.) Temp Range(M)
Humidity data: Interior RH (50%) Outdoor wet bulb (7 F) Humidity difference(53qr.)
Winter design temperature(MJ8 99%) 32 F Summer design temperature(MJ8 99%) 93 F
Winter setpoint 70 F Summer setpoint 75 F
Winter temperature difference 38 F Summer temperature difference 18 F
Total heating load calculation 38674 Btuh Total cooling load calculation 35819 Btuh
Submitted heating capacity %of calc Btuh Submitted cooling capacity %of caic Btuh
Total (Electric Heat Pump) 100.8 39000 Sensible (SHR =0.75) 109.7 29625
Heat Pump +Auxiliary(O.OkW) 100.8 39000 Latent 112.0 9875
1 Total (Electric Heat Pump) 110.3 39500
WINTER CALCULATIONS
Winter Heatinq Load(for 1835 sqft) Ventilti—(3%) Wndows(6%)
Load component Load Ducts(l I%)
Window total 144 sqft 2462 Btuh
Wall total 1724 sqft 6215 Btuh
hfil.(1 3%)
Door total 20 sqft 350 Btuh
Ceiling total 850 sqft 1029 Btuh ""A
Floor total See detail report 18163 Btuh Doors�l%)
Infiltration 125 cfm 5214 Btuh
Duct loss 4197 Btuh
Subtotal 37630 Btuh
Ventilation 25 cfm 1044 Btuh
TOTAL HEAT LOSS 38674 Btuh- Floors(47%)
SUMMER CALCULATIONS
Summer Cooling Load (for 1835 sqft)
Load component Load
Window total 144 sqft �1621 Btuh
Wall total 1724 sqft 4432 Btuh
Door total 20 sqft 267 Btuh
Ceiling total 850 sqft 1164 Btuh Verdflation(41%) VIA�d—(7%)
Floor total 4250 Btuh Lateryt lnternal(9%) %)
Infiltration 101 cfm 1998 Btuh ft(l 2%)
Internal gain 7380 Btuh
Duct gain 4396 Btuh %)
Sens. Ventilation 25 cfm 495 Btuh
Blower Load 0 Btuh
Floors�12%)
Total sensible gain 27003 Btuh
Latent gain(ducts) 1079 Btuh
%)
Latent gain(infiltration) 3637 Btuh
D—t.(l 5%)
Latent gain(ventilation) 900 Btuh
Latent gain(internal/occupants/other) 3200 Btuh
Total latent gain 8816 Btuh
TOTAL HEAT GAIN 35819 Btuh
EnergyGauge@ Systern Sizing
8th Edition PREPARED BY:
DATE: 2 2 1 -1
EnergyGauge@ USRFZB v2.8
System Sizing Calculations - Winter
Residential Load - Whole House Component Details
Project Title:
1886 Seminole
Building Type: User
Reference City:Jacksonville, FL (Defaults) Winter Temperature Difference: 38.0 F (MJ8 99%)
Component Loads for Whole House
Window _ Panes/Type Frame U Orientation Area(sqft) X HTM= Load
1 2, NFRC 0.66 Metal 0.45 S 72.0 17.1 1231 Btuh
2 2, NFRC 0.50 Metal 0.45 N 72.0 17.1 1231 Btuh
Window Total 144.0(sqft) 2462 Btuh
Walls Type Ornt. Ueff. R-Value Area X HTM= Load
(Cav/Sh)
I Frame - Wood Ext (0.095) 11.0/0.0 248 3.60 894 Btuh
2 Frame - Wood Ext (0.095) 11.0/0.0 704 3.60 2538 Btuh
3 Frame - Wood Ext (0.095) 11.0/0.0 68 3.60 245 Btuh
4 Frame - Wood Ext (0.095) 11.0/0.0 704 3.60 2538 Btuh
Wall Total 1 724(sqft) 6215 Btuh
Doors Type Storm Ueff. Area X HTM= Load
1 Wood - Exterior, n (0.460) 20 17.5 350 Btuh
Door Total 20(sqft) 350Btuh
Ceilings Type/Color/Surface Ueff. R-Value Area X HTM= Load
I Vented Attic/L/Shing (0.032) 30.0/0.0 850 1.2 1029 Btuh
Ceiling Total 850(sqft) 1029Btuh
Floors Type Ueff. R-Value Size X HTM= Load
1 Slab On Grade (1.180) 0.0 128.0 ft(perim.) 44.8 5740 Btuh
2 Raised -Open (0.385) 0.0 850.0 sqft 14.6 12424 Btuh
Floor Total 1700 sqft 18163 Btuh
Envelope Subtotal: 28219 Btuh
Infiltration Type ACH Volume(cuft) Wall Ratio CFM=
Natural(Adjusted for ventilation) 0.50 14680 1.00 124.9 5214 Btuh
Duct load Average sealed, R6.0, Supply(Att), Return(Att) (D LM of 0.126) 4197 Btuh
All Zones Sensible Subtotal All Zones 37630 Btuh
�HOLE HOUSE TOTALS
Subtotal Sensible Heat Loss 37630 Btuh
Totals for Heating Ventilation Sensible Heat Loss 1044 Btuh
Total Heat Loss 38674 Btuh
EnergyGauge@/USRFZB v2.8 Page 1
Manual J Winter Calculations
Residential Load - Component Details (continued)
Proiect Title:
3eminole
Building Type: User
EQUIPMENT
1. Electric Heat Pump # 39000 Btuh
Key:Window types-NFRC(Requires U-Factor and Shading coefficient(SHGC)of glass as numerical values)
or-Glass as'Clear'or'Tint'(Uses U-Factor and SHGC defaults)
U-(Window U-Factor)
HTM-(ManualJ Heat Transfer Multiplier)
Version 8
EnergyGauge@ USRFZB v2.8 Page 2
0
1 �I X i,
W h o,I e, F 1,,au s e
Project Title:
m8cSeminole
R f rence City:Jacksonville, FL Temperature Difference: 18.OF(MJ8 99%) Humidity difference: 53gr.
Component Loads for Whole House
Type* Overhang Window Area(sqft) HTM Load
Window Pane's SHGC U InSh IS Ornt Len Hgt Gross ShadedUnshadeq Shaded Unshaded
1 2 NFRC 0.66,0.45 No H S 1.5ft 1 Oft 72.0 72.0 0.0 20 25 1419 Btuh
2 2 NFFIC 0.50,0.45 No H N 1.5ft 1 Oft 72.0 0.0 72.0 17 17 1202 Btuh
Window 144 (sqft) 2621 Btuh
_Wa-l I s Type U-Value R-Value Area(sqft) HTM I Load
Cav/Sheath
1 Frame-Wood-Ext 0.09 11.0/0.0 248.0 2.6 638 Btuh
2 Frame-Wood-Ext 0.09 11.0/0.0 704.0 2.6 1810 Btuh
3 Frame-Wood-Ext 0.09 11.0/0.0 68.0 2.6 175 Btuh
4 Frame-Wood-Ext 0.09 11.0/0.0 704.0 2.6 1810 Btuh
Wall Total 1724(sqft) _____4432 Btuh
-b-0 o-rs-- Type Area(sqft) HTM Load
1 Wood-Exterior 20.0 13.3 267 Btuh
Door Total 20(sqft) 267 Btuh
Ceilings Type/Color/Surface U-Value R-Value Area(sqft) HTM Load
1 Vented Attic/Light/Shingle 0.032 30.0/0.0 850.0 1.37 1164 Btuh
�Ceiling Total 850(sqft) 1164 Btuh
Floors Type RN-alue Size HTM Load
Slab On Grade 0.0 850(ft-perimeter) 0.0 0 Btuh
Raised-Open 0.0 850(sqft) 5.0 4250 Btuh
Floor Total 1700.0 (sqft)_ 4250 Btuh
Envelope Subtotal: 12734 Btuh
I�In iltration Type ACH Volume(cuft) Wall Ratio CFM= Load
-I SensibleNatural 0.40 14680 1724 124.9 1998 Btuh
internal Occupants Btuh/&mup_a_nt Appliance Load
-_gain 4 X 230 + 6000 6920 Btuh
Sensible Envelope Load: 21652 Btuh
Di ict load Average sealed,Supply(R6.0-Attic),Return(R6.0-Attic) (DGM of 0.199) 4396 Btuh
Sensible Load All Zones 26048 Btuh
EnergyGauge@ USRFZB v2.8 RI(Ju 1
Manual J Summer Calculations
Residential Load - Component Details (continued)
Project Title: Climate:FL—JACKSONVILLE—INTL—ARPT
je;�(Seminole
WHOLE HOUSE TOTALS
Sensible Envelope Load All Zones 22112 Btuh
Sensible Duct Load 4396 Btuh
Total Sensible Zone Loads 26508 13tuh
Sensible ventilation 495 Btuh
Blower 0 Btuh
Whole House Total sensible gain 27003 Btuh
Totals for Cooling Latent infiltration gain (for 53 gr. humidity difference) 3637 Btuh
Latent ventilation gain 900 Btuh
Latent duct gain 1079 Btuh
Latent occupant gain (6 people @ 200 Btuh per person) 1200 Btuh
Latent other gain 2000 Btuh
Latent total gain 8816 Btuh
TOTAL GAIN 35819 Btuh
EQUIPMENT
1. Central Unit # 39500 Btuh
*Key: Window types(Panes-Number and type of panes of glass)
(SHGC-Shading coefficient of glass as SHGC numerical value)
(U-Window U-Factor)
(InSh-Interior shading device:none(No),Blinds(B),Draperies(D)or Roller Shades(R))
- For Blinds:Assume medium color,halt closed
For Draperies:Assume medium weave,half closed
2,
For Roller shades:Assume translucent,half closed
(IS-Insect screen:none(N),Full(F)or Half(1/2))
(Ornt-compass orientation)
Version 8
EnergyGauge@ USRFZB v2.8 Page 2
Trane Product Data
lCondenser I Ton. lindoor Unit I SEER I HSPF ITotal CaplSensible Cap.
:TWB3018Al 1.5 2TEC3Fl8Al 13 7.7 16300 12100
2,TWB3024Al 2 2TEC3F24Al 13 7.7 22500 16900
2TWB3030AI 2.5 2TEC3F3OAl 13 7.7 27400 20000
2TWB3036Al 3 2TEC3F36Al 13 7.7 33400 24400
27TWB3042Al 1 3.5 2TEC3F42Al 13 7.7 39500 28800
2TWB3048Al 1 4 12TEC3F48Al 1 13 1 7.7 45500 32800
2TWB306OAl 1 5 12TEC3F60AI 1 13 1 7.7 1 55500 1 39500
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH,FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 13-00003589 Date 10/28/13
Property Address . . . . . . 1886 SEMINOLE RD
Application type description ELECTRIC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation 0 -----------------------
-----------------------------------------------------
Application desc
ELEC FOR AC ------
-- -------------------------------------------------------------------
Owner Contractor--------------
----------
WATSON ELECTRIC
WATSON REALTY CORPORATION 4456 SUNBEAM RD STE 200
7821 DEERCREEK CLUB DR JACKSONVILLE FL 32257
JACKSONVILLE FL 322S6 (904) 899-6836
-- ------- -----------------------------------------------------------------
Permit . . . . . . ELECTRICAL PERMIT
Additional desc . - Plan Check Fee . 00
Permit Fee . . . . 60 . 00 Valuation . . . . 0
Issue Date . . . .
Expiration Date . - 4/26/14 --------------------------------
----- ---- - - - - - - - - - ----- --
Other-Fees STATE ELEC DCA SURCHARGE 2 . 00
STATE ELEC DBPR SURCHARGE 2 . 00
- ---------------- -------------------------------------------------- ------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 60 . 00 60 . 00 . 00 . 00
Plan Check Total . 00 * 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 64 . 00 64 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
ELECTRICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd, Atlantic Beach, FL 32233
Ph(904) 247-5826 Fax(904) 247-5845
PERMIT#
JOB ADDRESS:
ITS VOLTS —/ PHASE
JEA INFORMATION REQUIRED ON ALL PERM _AMPS
VALUE OF WORK S
NEW SERVICE 0 Overhead F_� Underground ED Underground up Pole
EResidential(Main) Service 0 151-200amps amps # of Meters
E10-100 amps [110 1-I 50amps
El Commercial(Main) Service El 151-200amps amps -1 CT Service_amps
EO-100 amps E 101-150amps
Conductor Type Size
El Multi-Family(Main) Service 0 151-200amps amps of Unit Meters
.�10-100 amps '_JI01-150amps
7jTemporary Pole El________:amps
SERVICE UPGRADE E—amps El CT Service amps
NEW FEEDER(ADDITIONS,ACCESSORY STRUCTURES,ETC.) EICT Service amps
D100amps E1150amps E1200amps []—amps
ADDITIONS,REMODELS,REPAIRS,BUILD-OUTS,ACCESSORY STRUCTURES,ETC.
Outlets/Switches: 0-30amps 3 1-1 00amps —101-200amps
— 0-30amps —3 1-I 00amps _101-200amps
Appliances: —
A/C Circuits: —0-60amps _61-100amps
Heat Circuits: — # circuits @__�kw
Number of Lighting Outlets, Including Fixtures: _
OTHER ELECTRICAL PROJECTS []Transformers KVA [iMotors—hp
,�SwimmingPool ESign El Smoke Detectors__Qty
FIRE ALARM SYSTEM (Requires 3 sets of plans) VALUE OF WORK S__�
Qty_volts/amps
REPAIRS/MISCELLANEOUS 0 Safety Inspection EPanel Change 0 OH to UG
E,Replace Bumt/Damaged Meter Can
r4her: 34c, /Ott-__
ithin a six month perio or work is suspend d or aban oned for six months. I hereby certify that I have
Permit becomes void if work does not commence
read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether
specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of
construction. Phone Number Y-!M
Property Owners Name
Electrical Company office Phone 9uqf)J2- &1�—FaX96Y
C C,;t" /11�, State Zip
ity _�L-'
Co. Address:
License Holder(Print): Ri A-4-tA State Certification/Registration
RPAPPON du I Ider
WA '* 20
ON VTAMYL e this a of
Sworn and bef
subscribed OrV
My COMMISSION#EE874577
EXPIRES FebrusrY Signature of Notary
(40T) iS3