Loading...
1912 Oak Circle HVAC 2013 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00002216 Date 2/22/13 Property Address . . . . . . 1912 OAK CIR Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ COOK THOMAS J TROPIC HEATING & AIR 1912 OAK CIRCLE 750 MAYPORT RD ATLANTIC BEACH FL 32233 ATLANTIC BEACH FL 32233 (904) 241-1788 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 103 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 8/21/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 103 . 00 103 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 107 . 00 107 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, Fl, 32233 Ph (904) 247-5826 Fax(904) 247-5845 JOB ADDRESS: /9/ 7— —PERMIT# PROJECTVALUE$ Y '-(9D " NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit — Heat: Unit Quantity BTU's Per Unit Seer Rating REQUIRED Duct Systems: Total CFM REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION ARI # Se.,-17YO6 Air Conditioning: Unit Quantity Tons Per Unit 3_5 REQUIRED Heat: Unit Quantity f BTUs Per Unit X. _S- Seer Rating___!�_S-_0 Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty— Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Tanks(gallons) Wells OTHER: Perinit becomes void if work does not cominence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and coffect All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name 7.P- ,-, 4e/5 PhoneNumber SS(�- 9964 Mechanical Company 77-*.,q,_r Office Phone 2VI-170 Fax Z-,Y/ —Z-t7Z _0 I t �, city A-- Stateffi. Zip32-z?? - Co. Address: 75 A 11 License Holder(Print): State Certification/Registration# Notarized,Signature of License older (C Sworn and subscribed before me this <:�-c�- dayof rybru 20LZ- Adudf,� KAREN E.PANTFOIEDER NOTARY PUBLIC Signature of Notary STATE OF FLORIDA .CAMCOrriffi#EE064448 4W E,,Ores 3/4/2o15 This combination qualifies for a Federal Energy 04 "IMF Efficiency Tax Credit when placed in service rin wmal CERTIFIEDT. between Feb 17, 2009 and Dec 31, 2013. L vvww.a h ri directory.o rg I Certificate of Product Ratings AHRI Certified Reference Number: 3647406 Date: 2/22/2013 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 215BNA042****A Indoor Unit Model Number: FX4DN(B,F)043 Manufacturer: BRYANT HEATING AND COOLING SYSTEMS Trade/Brand name: LEGACY LINE PURON HP Manufacturer responsible for the rating of this system combination is BRYANT HEATING AND COOLING SYSTEMS Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (Btuh): 41500 EER Rating (Cooling): 12.50 SEER Rating (Cooling): 15.00 Heating Capacity(Btuh) @ 47 F: 42000* Region IV HSPF Rating (Heating): 8.50* Heating Capacity(Btuh) @ 17 F: 26400 Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectoryorg. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in pan,be reproduced;copied;disseminated;entered Into a computer database;or otherwise utilized,In any form or manner or by any means,except for the user's Individual,personal and confidential referenm CERTIFICATE VERIFICATION Theinformation forthemodel cited onthis certificate can beverified at www.ahridirectory.org, Air-Conditioning,Heating, dickon"Verity Certificate"link and entertheAHRI Certified Reference Numberand the dateon which the certificate was Issued,which Is listed above,and the Certificate No.,which Is listed below. no ILI and Refrigeration Institute @2012 Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 130060206305668735 Project Summary Job: Cook Date: 2/21/2013 Entire House By: ft" AL Project Information For: Tom Cook, Tropic Heating&AirConditioning,lnc. 1912 Oak Cr., Atlantic Beach, FL 32233 Phone: 904-241-1788 Fax: 904-241-2172 Email: Tropicac@msn.com Notes: Design Information Weather: Jacksonville/Craig, FL, US Winter Design Conditions Summer Design Conditions Outside db 35 'F Outside db 91 'F Inside db 70 oF Inside db 75 'F Design TD 35 'F Design TD 16 'F Daily range M Relative humidity 50 % Moisture difference 53 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 26433 Btuh Structure 22739 Btuh Ducts 6685 Btuh Ducts 6016 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 33118 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 28756 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3150 Btuh Ducts 1756 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft2) 2080 2080 Equipment latent load 4906 Btuh Volume(ft3) 18720 18720 Air changes/hour 0.41 0.21 Equipment total load 33661 Btuh Equiv.AVF(cfm) 128 66 Req. total capacity at 0.70 SHR 3.4 ton Heating Equipment Summary Cooling Equipment Summary Make n/a Make Trade n/a Trade Model n/a Cond AHRI ref n/a Coil AHRI ref Efficiency n/a Efficiency 0 SEER Heating input 0 MBtuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 'F Total cooling 0 Btuh Actual air flow 1302 cfm Actual air flow 1302 cfm Air flow factor 0.039 cfm/Btuh Air flow factor O�045 cfm/Btuh Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat Load sensible heat ratio 0.85 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-Feb-21 lT07:53 wriightSOft Right-Suitee Universal 2012 12.1.05 Right JO Mobile Pagel C:\WINDOWS\TEMP\wstmp\f5faebOe-8793-4baf-a36d-94fc645cl6O9.rup Calc=MJ8 FrontDoorfaces: E Job: Cook 19 ht J@ Mobile Report Date: 2/21/2013 Entire House By: AL Project Information For: Tom Cook, Tropic Heating&AirConditioning,inc. 1912 Oak Cr.,Atlantic Beach, FL 32233 Phone: 904-241-1788 Fax: 904-241-2172 Email: Tropicac@msn.com 1 7- Design Conditions Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature('F) 70 75 Elevation: 43 ft Design TD('F) 35 16 Latitude: 30'N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 8.4 52.8 Dry bulb('F) 35 91 Infiltration: Da i I y ra nge('F) - 17 ( M Method Simplified Wet bulb(o F) - 77 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 11*1111MM Component Btu h/fl2 Btuh %of load Walls 3.4 7648 23.1 Glazing 19.7 4125 12.5 \MIS Dits Doors 13.5 433 1.3 Ceilings 1.7 2224 6.7 Floors 5.4 7142 21.6 A Infiltration 1.9 4861 14.7 - "'/10 -- IrfitrzIlim Ducts 6685 20.2 Gazirg Piping 0 0 QhEr Humidification 0 0 Gslirlgs AWS Ventilation 0 0 Adjustments 0 Total 1 1 33118, 100.01 Home Component Btu h/ft2 Btuh %of load Walls 2.6 5946 20.7 1 rtand GEins Glazing 39.1 8182 28.5 VWls, Doors 11.4 367 1.3 Ceilings 2.1 2752 9.6 Floors 0 0 0 Infiltration 0.5 1173 4.1 Ducts Ducts 6016 20.9 Ventilation 0 0 Internal gains 4320 15.0 Blower 0 Ga2irld 0 Adjustments 0 Infiltation Total 1 1 28756, 100.01 Cther Ceilirgs Latent fooling Load=4906 Btuh Overall I U-\ra lue=0.121 Btuh/ft2-'F Data entries checked. 2013-Feb-21 17:07:53 wrightSoft Right-Suitea Universal 2012 12.1.05 Right JO Mobile Page 1 ACC-k C:\WINDOWS\TEMP\wstmp\f5faebOc-8793-4baf-a36d-94fc645cl6O9.rup Calc=MJ8 Front Door faces: E Right-J@ Worksheet Job: Cook Entire House Date: 2121/2013 By: AL 1 Room name Enbre House First Floor 2 Exposed wall 280.0 ft 152.0 ft 3 Room height 9.0 ft d 9.0 ft heat/cool 4 Room dimensions 1.0 x 1312.0 ft 5 Room area 2080.0 ft2 1312.0 ft2 Construction U-value, or HTM Area (ft2 Load Area (f t2) Load ber (Btuh/ft2_ F) (BtUlVft2) or perimeter (ft (Btuh) or perimeter (Btuh) Ty I 11-M Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 2B-Osw 0.097 n 3.36 2.61 756 661 2220 1726 396 326 1093 850 11 D-c2ov 0.570 n 19.72 20.91 63 0 1233 1307 38 0 756 802 I I DO 0.390 n 13.49 11.43 32 32 433 367 32 32 433 367 12B-Osw 0.097 e 3.36 2.61 504 462 1552 1206 288 261 874 680 11 t---G 1 D-c2ov 0.570 e 19.72 63.01 42 0 822 2625 28 0 542 1733 2B-Osw 0.097 s 3.36 2.61 756 694 2328 1810 396 358 1200 933 t--G 11 D-c2ov 0.570 s 19.72 25.16 63 0 1233 1572 38 0 756 964 12B-Osw 0.097 w 3.36 2.61 504 462 1549 1204 288 261 874 680 t--G I D-c2ov 0.570 w 19.72 63.01 43 0 838 2678 27 0 542 1733 C 16C-19al 0.049 1.70 2.10 1312 1312 2224 2752 544 544 922 1141 F 22A-cDh 1.358 46.99 0.00 1312 152 7142 0 1312 152 7142 0 1 61 c)AED excursion 1 01 1 1 1 01 Envelope loss/gain 1 215721 172461 1 1 151361 98811 12 a) Infiltration 4861 1173 2639 637 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 4 920 4 920 Appliances/other 3400 3400 Subtotal(lines 6 to 13) 26433 22739 17775 14838 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 26433 22739 17775 14838 15 Duct loads 25% 26% 6685 6016 25% 26% 4495 3926 Total room load 331181 287561 222691 187641 Air required(cfm) 1 1 13021 13021 8761 8501 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -F++- wrightcft 2013-Feb-21 17:07:53 Right-SuiteO Universal 2012 12.1.05 Right JO Mobile Page 1 A&�C:\WINDOWS\TEMP\vstmp\t5faebOc-8793-4baf-a36d-94fc645cl6O9.rup Calc=MJ8 Front Door faces: E i Right-M) Worksheet Job: Cook Entire House Date: 2121/2013 By: AL 1 Room name Second Floor 2 Exposed wall 128.0 ft 3 Room height 9.0 It heat/cool 4 Room dimensions 1.0 x 768.0 ft 5 Room area 768.0 ft2 I I I I I I Ty Construction U-value Or HTM Area (ft2) Load Area Load number Btuh/ft2_'F) (St uWft 2 or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 VL12B-Osw 0.097 n 3.36 2.61 360 336 1127 876 --G I D-c2ov 0.570 n 19.72 20.91 24 0 477 505 I I DO 0.390 n 13.49 11.43 0 0 0 0 V" 1213-Osw 0.097 e 3.36 2.61 216 202 677 527 1 1 D-c2ov 0.570 e 19.72 63.01 14 0 279 893 '2B-Osw 0.097 s 3.36 2.61 360 336 1127 876 t--G I D-c2ov 0.570 s 19.72 25.16 24 0 477 608 1 2B-Osw 0.097 w 3.36 2.61 216 201 675 524 G 1 D-c2ov 0.570 w 19.72 63.01 15 0 296 945 C 16C-19al 0.049 1.70 2.10 768 768 1302 1611 F 22A-cr)h 1.358 46.99 0.00 0 0 0 0 61 c)AED excursion 1 01 1 1 1 Envelope loss/gain 64371 73651 1 1 1 12 a) Infiltration 2222 536 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal(lines 6 to 13) 8659 7902 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 8659 7902 15 Duct loads 25% 26% 2190 2091 Tot I room load 108491 99921 Air arequired(cfm) 1 1 4271 4531 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -..-k wrightsaft 2013-Feb-21 17:07:53 Right-SuiteOD Universal 2012 12.1.05 Right JO Mobile Page 2 Aftk C:\WINDOWS\TEMP\vvstmp\f5faebOc-8793-4baf-a36d-94fc645cl6O9.rup Cale=MJ8 Front Door faces: E Component Constructions Job: Cook Date: 2121/2013 Entire House By: AL Project Information For: Tom Cook, Tropic Heating&AirConditioning,lnc. 1912 Oak Cr.,Atlantic Beach, FL 32233 Phone: 904-241-1788 Fax: 904-241-2172 Email:Tropicac@msn.com Design Conditions Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature(*F) 70 75 Elevation: 43 ft Design TD(*F) 35 16 Latitude: 30'N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 8.4 52.8 Dry bul b('F) 35 91 Infiltration: Dailyrange(*F) - 17 ( M Method Simplified Wet bulb(*F) - 77 Construction quality Average VVind speed(mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area 1.1-value Insul R Htg HTM Loss Cig HTM Gain ft2 BMA?-'F ft2-'F/Duh BtuhM Btuh BtuhV Btuh Walls 12B-Osw:Frrn wall,vnl ext, r-1 1 cav ins, 1/7'gypsum board int n 661 0.097 11.0 3.36 2220 2.61 1726 fnsh,ZW"wood frm e 462 0.097 11.0 3.36 1552 2.61 1206 s 694 0.097 11.0 3.36 2328 2.61 1810 W 462 0.097 11.0 3.36 1549 2.61 1204 all 2279 0.097 11.0 3.36 7648 2.61 5946 Partitions (none) Windows 1 D-c2ov:2 glazing,c1r outr,air gas,vnl frm mat,clr innr,1/4"gap, n 63 0.570 0 19.7 1233 20.9 1307 1/8"thk e 42 0.570 0 19.7 822 63.0 2625 s 63 0.570 0 19.7 1233 25.2 1572 w 43 0.570 0 19.7 838 63.0 2678 all 209 0.570 0 19.7 4125 391 8182 Doors 11 DO:Door,vvd sc type n 32 0.390 0 13.5 433 11.4 367 Ceilings 16C-19al:Attic ceiling, asphaft shingles roof mat,r-19 ceil ins, 1/2' 1312 0.049 19.0 1.70 2224 2.10 2752 gypsum board int frish Floors 22A-cph:Bg floor,heavy damp soil,on grade depth,carpet flr frish 152 1.358 0 4TO 7142 0 0 2013-Feb-21 17:07:53 wrightSOft Right-Suite@ Universal 2012 12.1.05 Right JS Mobile Page 1 C:\WINDOWS\TEMP\wstmp\f5faebOc-8793-4baf-a36d-94fc645cl6O9.rup Calc=MJ8 Front Door faces: E Job: Cook AED Assessment Date: 2/21/2013 Entire House By: AL Project Information For: Tom Cook,Tropic Heating&AirConditioning,lnc. 1912 Oak Cr., Atlantic Beach, FL 32233 Phone: 904-241-1788 Fax: 904-241-2172 Email:Tropicac@msn.com Design Conditions Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature(oF) 70 75 Elevation: 43 ft Design TD('F) 35 16 Latitude: 30'N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 8.4 52.8 Dry bulb('F) 35 91 Infiltration: Dailyrange(oF) - 17 M Wetbulb('F) - 77 Wind speed (mph) 15.0 7.5 Test for Adequate Exposure Diversity 11,000- Hourly Glazing Load 10,00& 9'00C_ 8,OOE 7,OOE- 6,00(", 5,OOE- 4,OOE- 3,OOE- 2,00(- 1 ,OOE- 0 8 9 10 11 12 13 14 15 16 17 18 19 20 Hour of Day Houdy Aerage AEDliMt Maximum hourly glazing load exceeds average by 19.0%. House has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh 2013-Feb-21 17:07:53 wrightSOft Right-suite@ universal 2012 12.1.05 Right J0 Mobile Page 1 C:\WINDOWS\TEMP\wstmp\f5faebOc-8793-4baf-a36d-94fc645cl6O9.rup Calc=MJ8 FrontDoorfaces: E