1912 Oak Circle HVAC 2013 CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 13-00002216 Date 2/22/13
Property Address . . . . . . 1912 OAK CIR
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
1 cu 1 ahu
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
COOK THOMAS J TROPIC HEATING & AIR
1912 OAK CIRCLE 750 MAYPORT RD
ATLANTIC BEACH FL 32233 ATLANTIC BEACH FL 32233
(904) 241-1788
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee . . . . 103 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 8/21/13
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 103 . 00 103 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 107 . 00 107 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, Fl, 32233
Ph (904) 247-5826 Fax(904) 247-5845
JOB ADDRESS: /9/ 7— —PERMIT#
PROJECTVALUE$ Y '-(9D "
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit —
Heat: Unit Quantity BTU's Per Unit Seer Rating REQUIRED
Duct Systems: Total CFM
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
ARI # Se.,-17YO6
Air Conditioning: Unit Quantity Tons Per Unit 3_5 REQUIRED
Heat: Unit Quantity f BTUs Per Unit X. _S- Seer Rating___!�_S-_0
Duct Systems: Total CFM REQUIRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty— Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
#Water Heaters Solar Collection Systems
Tanks(gallons)
Wells
OTHER:
Perinit becomes void if work does not cominence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
this application and know the same to be true and coffect All provisions of laws and ordinances governing this work will be complied with whether specified
or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
Property Owners Name 7.P- ,-, 4e/5 PhoneNumber SS(�- 9964
Mechanical Company 77-*.,q,_r Office Phone 2VI-170 Fax Z-,Y/ —Z-t7Z
_0 I t �, city A-- Stateffi. Zip32-z?? -
Co. Address: 75 A 11
License Holder(Print): State Certification/Registration#
Notarized,Signature of License older (C
Sworn and subscribed before me this <:�-c�- dayof rybru 20LZ-
Adudf,� KAREN E.PANTFOIEDER
NOTARY PUBLIC Signature of Notary
STATE OF FLORIDA
.CAMCOrriffi#EE064448
4W E,,Ores 3/4/2o15
This combination qualifies for a Federal Energy
04 "IMF Efficiency Tax Credit when placed in service
rin wmal CERTIFIEDT.
between Feb 17, 2009 and Dec 31, 2013.
L vvww.a h ri directory.o rg
I
Certificate of Product Ratings
AHRI Certified Reference Number: 3647406 Date: 2/22/2013
Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source
Outdoor Unit Model Number: 215BNA042****A
Indoor Unit Model Number: FX4DN(B,F)043
Manufacturer: BRYANT HEATING AND COOLING SYSTEMS
Trade/Brand name: LEGACY LINE PURON HP
Manufacturer responsible for the rating of this system combination is BRYANT HEATING AND COOLING
SYSTEMS
Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third
party testing:
Cooling Capacity (Btuh): 41500
EER Rating (Cooling): 12.50
SEER Rating (Cooling): 15.00
Heating Capacity(Btuh) @ 47 F: 42000*
Region IV HSPF Rating (Heating): 8.50*
Heating Capacity(Btuh) @ 17 F: 26400
Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate.
DISCLAIMER
AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for,
the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the
unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectoryorg.
TERMS AND CONDITIONS
This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.
The contents of this Certificate may not,in whole or in pan,be reproduced;copied;disseminated;entered Into a computer database;or otherwise utilized,In any
form or manner or by any means,except for the user's Individual,personal and confidential referenm
CERTIFICATE VERIFICATION
Theinformation forthemodel cited onthis certificate can beverified at www.ahridirectory.org, Air-Conditioning,Heating,
dickon"Verity Certificate"link and entertheAHRI Certified Reference Numberand the dateon
which the certificate was Issued,which Is listed above,and the Certificate No.,which Is listed below. no ILI and Refrigeration Institute
@2012 Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 130060206305668735
Project Summary Job: Cook
Date: 2/21/2013
Entire House By:
ft"
AL
Project Information
For: Tom Cook, Tropic Heating&AirConditioning,lnc.
1912 Oak Cr., Atlantic Beach, FL 32233
Phone: 904-241-1788 Fax: 904-241-2172
Email: Tropicac@msn.com
Notes:
Design Information
Weather: Jacksonville/Craig, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 35 'F Outside db 91 'F
Inside db 70 oF Inside db 75 'F
Design TD 35 'F Design TD 16 'F
Daily range M
Relative humidity 50 %
Moisture difference 53 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 26433 Btuh Structure 22739 Btuh
Ducts 6685 Btuh Ducts 6016 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 33118 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 28756 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 3150 Btuh
Ducts 1756 Btuh
Heating Cooling Central vent(0 cfm) 0 Btuh
Area(ft2) 2080 2080 Equipment latent load 4906 Btuh
Volume(ft3) 18720 18720
Air changes/hour 0.41 0.21 Equipment total load 33661 Btuh
Equiv.AVF(cfm) 128 66 Req. total capacity at 0.70 SHR 3.4 ton
Heating Equipment Summary Cooling Equipment Summary
Make n/a Make
Trade n/a Trade
Model n/a Cond
AHRI ref n/a Coil
AHRI ref
Efficiency n/a Efficiency 0 SEER
Heating input 0 MBtuh Sensible cooling 0 Btuh
Heating output 0 Btuh Latent cooling 0 Btuh
Temperature rise 0 'F Total cooling 0 Btuh
Actual air flow 1302 cfm Actual air flow 1302 cfm
Air flow factor 0.039 cfm/Btuh Air flow factor O�045 cfm/Btuh
Static pressure 0 in H20 Static pressure 0 in H20
Space thermostat Load sensible heat ratio 0.85
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2013-Feb-21 lT07:53
wriightSOft Right-Suitee Universal 2012 12.1.05 Right JO Mobile Pagel
C:\WINDOWS\TEMP\wstmp\f5faebOe-8793-4baf-a36d-94fc645cl6O9.rup Calc=MJ8 FrontDoorfaces: E
Job: Cook
19 ht J@ Mobile Report Date: 2/21/2013
Entire House By:
AL
Project Information
For: Tom Cook, Tropic Heating&AirConditioning,inc.
1912 Oak Cr.,Atlantic Beach, FL 32233
Phone: 904-241-1788 Fax: 904-241-2172
Email: Tropicac@msn.com
1 7- Design Conditions
Location: Indoor: Heating Cooling
Jacksonville/Craig, FL, US Indoor temperature('F) 70 75
Elevation: 43 ft Design TD('F) 35 16
Latitude: 30'N Relative humidity(%) 30 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 8.4 52.8
Dry bulb('F) 35 91 Infiltration:
Da i I y ra nge('F) - 17 ( M Method Simplified
Wet bulb(o F) - 77 Construction quality Average
Wind speed(mph) 15.0 7.5 Fireplaces 0
11*1111MM
Component Btu h/fl2 Btuh %of load
Walls 3.4 7648 23.1
Glazing 19.7 4125 12.5 \MIS Dits
Doors 13.5 433 1.3
Ceilings 1.7 2224 6.7
Floors 5.4 7142 21.6
A
Infiltration 1.9 4861 14.7 - "'/10 -- IrfitrzIlim
Ducts 6685 20.2 Gazirg
Piping 0 0 QhEr
Humidification 0 0 Gslirlgs AWS
Ventilation 0 0
Adjustments 0
Total 1 1 33118, 100.01
Home
Component Btu h/ft2 Btuh %of load
Walls 2.6 5946 20.7 1 rtand GEins
Glazing 39.1 8182 28.5 VWls,
Doors 11.4 367 1.3
Ceilings 2.1 2752 9.6
Floors 0 0 0
Infiltration 0.5 1173 4.1 Ducts
Ducts 6016 20.9
Ventilation 0 0
Internal gains 4320 15.0
Blower 0 Ga2irld
0
Adjustments 0 Infiltation
Total 1 1 28756, 100.01 Cther Ceilirgs
Latent fooling Load=4906 Btuh
Overall I U-\ra lue=0.121 Btuh/ft2-'F
Data entries checked.
2013-Feb-21 17:07:53
wrightSoft Right-Suitea Universal 2012 12.1.05 Right JO Mobile Page 1
ACC-k C:\WINDOWS\TEMP\wstmp\f5faebOc-8793-4baf-a36d-94fc645cl6O9.rup Calc=MJ8 Front Door faces: E
Right-J@ Worksheet Job: Cook
Entire House Date: 2121/2013
By:
AL
1 Room name Enbre House First Floor
2 Exposed wall 280.0 ft 152.0 ft
3 Room height 9.0 ft d 9.0 ft heat/cool
4 Room dimensions 1.0 x 1312.0 ft
5 Room area 2080.0 ft2 1312.0 ft2
Construction U-value, or HTM Area (ft2 Load Area (f t2) Load
ber (Btuh/ft2_ F) (BtUlVft2) or perimeter (ft (Btuh) or perimeter (Btuh)
Ty I 11-M Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 2B-Osw 0.097 n 3.36 2.61 756 661 2220 1726 396 326 1093 850
11 D-c2ov 0.570 n 19.72 20.91 63 0 1233 1307 38 0 756 802
I I DO 0.390 n 13.49 11.43 32 32 433 367 32 32 433 367
12B-Osw 0.097 e 3.36 2.61 504 462 1552 1206 288 261 874 680
11 t---G 1 D-c2ov 0.570 e 19.72 63.01 42 0 822 2625 28 0 542 1733
2B-Osw 0.097 s 3.36 2.61 756 694 2328 1810 396 358 1200 933
t--G 11 D-c2ov 0.570 s 19.72 25.16 63 0 1233 1572 38 0 756 964
12B-Osw 0.097 w 3.36 2.61 504 462 1549 1204 288 261 874 680
t--G I D-c2ov 0.570 w 19.72 63.01 43 0 838 2678 27 0 542 1733
C 16C-19al 0.049 1.70 2.10 1312 1312 2224 2752 544 544 922 1141
F 22A-cDh 1.358 46.99 0.00 1312 152 7142 0 1312 152 7142 0
1 61 c)AED excursion 1 01 1 1 1 01
Envelope loss/gain 1 215721 172461 1 1 151361 98811
12 a) Infiltration 4861 1173 2639 637
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 4 920 4 920
Appliances/other 3400 3400
Subtotal(lines 6 to 13) 26433 22739 17775 14838
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 26433 22739 17775 14838
15 Duct loads 25% 26% 6685 6016 25% 26% 4495 3926
Total room load 331181 287561 222691 187641
Air required(cfm) 1 1 13021 13021 8761 8501
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
-F++- wrightcft 2013-Feb-21 17:07:53
Right-SuiteO Universal 2012 12.1.05 Right JO Mobile Page 1
A&�C:\WINDOWS\TEMP\vstmp\t5faebOc-8793-4baf-a36d-94fc645cl6O9.rup Calc=MJ8 Front Door faces: E
i
Right-M) Worksheet Job: Cook
Entire House Date: 2121/2013
By:
AL
1 Room name Second Floor
2 Exposed wall 128.0 ft
3 Room height 9.0 It heat/cool
4 Room dimensions 1.0 x 768.0 ft
5 Room area 768.0 ft2
I I I I I I
Ty Construction U-value Or HTM Area (ft2) Load Area Load
number Btuh/ft2_'F) (St uWft 2 or perimeter (ft) (Btuh) or perimeter
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 VL12B-Osw 0.097 n 3.36 2.61 360 336 1127 876
--G I D-c2ov 0.570 n 19.72 20.91 24 0 477 505
I I DO 0.390 n 13.49 11.43 0 0 0 0
V" 1213-Osw 0.097 e 3.36 2.61 216 202 677 527
1 1 D-c2ov 0.570 e 19.72 63.01 14 0 279 893
'2B-Osw 0.097 s 3.36 2.61 360 336 1127 876
t--G I D-c2ov 0.570 s 19.72 25.16 24 0 477 608
1 2B-Osw 0.097 w 3.36 2.61 216 201 675 524
G 1 D-c2ov 0.570 w 19.72 63.01 15 0 296 945
C 16C-19al 0.049 1.70 2.10 768 768 1302 1611
F 22A-cr)h 1.358 46.99 0.00 0 0 0 0
61 c)AED excursion 1 01 1 1 1
Envelope loss/gain 64371 73651 1 1 1
12 a) Infiltration 2222 536
b) Room ventilation 0 0
13 Internal gains: Occupants @ 230 0 0
Appliances/other 0
Subtotal(lines 6 to 13) 8659 7902
Less external load 0 0
Less transfer 0 0
Redistribution 0 0
14 Subtotal 8659 7902
15 Duct loads 25% 26% 2190 2091
Tot I room load 108491 99921
Air arequired(cfm) 1 1 4271 4531
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
-..-k wrightsaft 2013-Feb-21 17:07:53
Right-SuiteOD Universal 2012 12.1.05 Right JO Mobile Page 2
Aftk C:\WINDOWS\TEMP\vvstmp\f5faebOc-8793-4baf-a36d-94fc645cl6O9.rup Cale=MJ8 Front Door faces: E
Component Constructions Job: Cook
Date: 2121/2013
Entire House By:
AL
Project Information
For: Tom Cook, Tropic Heating&AirConditioning,lnc.
1912 Oak Cr.,Atlantic Beach, FL 32233
Phone: 904-241-1788 Fax: 904-241-2172
Email:Tropicac@msn.com
Design Conditions
Location: Indoor: Heating Cooling
Jacksonville/Craig, FL, US Indoor temperature(*F) 70 75
Elevation: 43 ft Design TD(*F) 35 16
Latitude: 30'N Relative humidity(%) 30 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 8.4 52.8
Dry bul b('F) 35 91 Infiltration:
Dailyrange(*F) - 17 ( M Method Simplified
Wet bulb(*F) - 77 Construction quality Average
VVind speed(mph) 15.0 7.5 Fireplaces 0
Construction descriptions Or Area 1.1-value Insul R Htg HTM Loss Cig HTM Gain
ft2 BMA?-'F ft2-'F/Duh BtuhM Btuh BtuhV Btuh
Walls
12B-Osw:Frrn wall,vnl ext, r-1 1 cav ins, 1/7'gypsum board int n 661 0.097 11.0 3.36 2220 2.61 1726
fnsh,ZW"wood frm e 462 0.097 11.0 3.36 1552 2.61 1206
s 694 0.097 11.0 3.36 2328 2.61 1810
W 462 0.097 11.0 3.36 1549 2.61 1204
all 2279 0.097 11.0 3.36 7648 2.61 5946
Partitions
(none)
Windows
1 D-c2ov:2 glazing,c1r outr,air gas,vnl frm mat,clr innr,1/4"gap, n 63 0.570 0 19.7 1233 20.9 1307
1/8"thk e 42 0.570 0 19.7 822 63.0 2625
s 63 0.570 0 19.7 1233 25.2 1572
w 43 0.570 0 19.7 838 63.0 2678
all 209 0.570 0 19.7 4125 391 8182
Doors
11 DO:Door,vvd sc type n 32 0.390 0 13.5 433 11.4 367
Ceilings
16C-19al:Attic ceiling, asphaft shingles roof mat,r-19 ceil ins, 1/2' 1312 0.049 19.0 1.70 2224 2.10 2752
gypsum board int frish
Floors
22A-cph:Bg floor,heavy damp soil,on grade depth,carpet flr frish 152 1.358 0 4TO 7142 0 0
2013-Feb-21 17:07:53
wrightSOft Right-Suite@ Universal 2012 12.1.05 Right JS Mobile Page 1
C:\WINDOWS\TEMP\wstmp\f5faebOc-8793-4baf-a36d-94fc645cl6O9.rup Calc=MJ8 Front Door faces: E
Job: Cook
AED Assessment Date: 2/21/2013
Entire House By:
AL
Project Information
For: Tom Cook,Tropic Heating&AirConditioning,lnc.
1912 Oak Cr., Atlantic Beach, FL 32233
Phone: 904-241-1788 Fax: 904-241-2172
Email:Tropicac@msn.com
Design Conditions
Location: Indoor: Heating Cooling
Jacksonville/Craig, FL, US Indoor temperature(oF) 70 75
Elevation: 43 ft Design TD('F) 35 16
Latitude: 30'N Relative humidity(%) 30 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 8.4 52.8
Dry bulb('F) 35 91 Infiltration:
Dailyrange(oF) - 17 M
Wetbulb('F) - 77
Wind speed (mph) 15.0 7.5
Test for Adequate Exposure Diversity
11,000- Hourly Glazing Load
10,00&
9'00C_
8,OOE
7,OOE-
6,00(",
5,OOE-
4,OOE-
3,OOE-
2,00(-
1 ,OOE-
0
8 9 10 11 12 13 14 15 16 17 18 19 20
Hour of Day
Houdy Aerage AEDliMt
Maximum hourly glazing load exceeds average by 19.0%.
House has adequate exposure diversity (AED), based on AED limit of 30%.
AED excursion: 0 Btuh
2013-Feb-21 17:07:53
wrightSOft Right-suite@ universal 2012 12.1.05 Right J0 Mobile Page 1
C:\WINDOWS\TEMP\wstmp\f5faebOc-8793-4baf-a36d-94fc645cl6O9.rup Calc=MJ8 FrontDoorfaces: E