Loading...
Permit HVAC 1911 Beach Ave 2013 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD a ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 r sill Application Number . . . . . 13-00002220 Date 2/25/13 Property Address . . . . . . 1911 BEACH AVE Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 3000 ---------------------------------------------------------------------------- Application desc replace 1 cu 1 ahu ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ PETWAY THOMAS F IV TROPIC HEATING & AIR 1911 BEACH AVE 750 MAYPORT RD ATLANTIC BEACH FL 322335936 ATLANTIC BEACH FL 32233 (904) 241-1788 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . REPLACE 1 CU 1 AHU Permit Fee . . . . 111 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 3000 Expiration Date . . 8/24/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 111 . 00 111 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 115 . 00 115 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247-5826 Fax(904) 247-5845 r JOB ADDRESS: `7 1 l ie . PERMIT# / 3 x30 PROJECT VALUE $ 3,000 NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION ARI# 3 to 99 SSS Air Conditioning: Unit Quantity I Tons Per Unit 1 •S REQUIRED Heat: Unit Quantity I BTU's Per Unit 1 , S Seer Rating X3.0 Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Tanks(gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name T 1)0-+w Phone Number 32-7 - Mechanical Company-P; �-iPi C Office Phone�`F1-I� F a 7 Co. Address: 757 (YN City State '-. Zip3.zk License Holder(Print): 0, ecki-,s State Certification/Registration# a`f3 Notarized Signature of License Holder KAREN E.PANTFOEDER Sworn and subscribed before me this o?S day of 1:�-b1'Ua 2013 NOTARY PUBLIC Signature of Notary Public N�1—� e f&jmzki�� STATE OF FLORIDA Comm#EE064448 Expires 3/4/2015 r ru sual r , Certificate of Product Ratings AHRI Certified Reference Number: 3699555 Date: 2/25/2013 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 213BN(A,W)018****A Indoor Unit Model Number: FB4CNF018 Manufacturer: BRYANT HEATING AND COOLING SYSTEMS Trade/Brand name: LEGACY LINE PURON HP Manufacturer responsible for the rating of this system combination is BRYANT HEATING AND COOLING SYSTEMS Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (Btuh): 17400 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Heating Capacity(Btuh) @ 47 F: 17400 Region IV HSPF Rating (Heating): 8.00 Heating Capacity(Btuh) @ 17 F: 10500 'Ratings followed by an asterisk(')indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary cerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),orthe unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectoryorg. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or In part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION it "n' The information forthe model cited on this certificate can be verified at www.ahrid irectory.org, Air-Conditioning,Heating, dick on"Verity Certificate"link and enter the AHRI Certified Reference Number and the date on IOU ,' and Refrigeration Institute which the certificate was issued,which Is listed above,and the Certificate Na,which is listed below. ©2012 Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 130062809205978313 Pro ect Summary Job: 2Date: 2/225/205/20 � � '7 13 Entire House By: low aa111re AL Project • • For: Ty Petway, Tropic Heating&AirConditioning,lnc. 1911 Beach Ave.,Atlantic Beach, FL 32233 Phone: 904-241-1788 Fax: 904-241-2172 Email: Tropicac@msn.com Notes: Design Information Weather: Jacksonville/Craig, FL, US Winter Design Conditions Summer Design Conditions Outside db 35 °F Outside db 91 °F Inside db 70 °F Inside db 75 °F Design TD 35 °F Design TD 16 °F Daily range M Relative humidity 50 % Moisture difference 53 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 10747 Btuh Structure 10510 Btuh Ducts 1711 Btuh Ducts 1896 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 12458 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 12406 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1674 Btuh Ducts 487 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft2) 650 650 Equipment latent load 2161 Btuh Volume(fts) 5200 5200 Air changes/hour 0.79 0.41 Equipment total load 14568 Btuh Equiv. AVF(cfm) 68 36 Req. total capacity at 0.70 SHR 1.5 ton Heating Equipment Summary Cooling Equipment Summary Make n/a Make Trade n/a Trade Model n/a Cond AHRI ref n/a Coil AHRI ref Efficiency n/a Efficiency 0 SEER Heating input 0 MBtuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 541 cfm Actual air flow 541 cfm Air flow factor 0.043 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.85 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013Feb-2507:47:40wri ht50ft Right-Suke®Universa12012 12.1.05 Right JMobile Page 1 AGC0. C:\WIND0WS\TEMP\watmp\17fDc2d7-8f7d-4609-9473-fe2fa37d086a.rup Calc=MJ8 Front Door faces: E Ri htJ@Mobile Report Job: 2 � g � Date: 2/25/2025/20 13 Entire House By: rMrw ria�r�tna•• AL Project • • For: Ty Petway, Tropic Heating&AirConditioning,lnc. 1911 Beach Ave.,Atlantic Beach, FL 32233 Phone: 904-241-1788 Fax: 904-241-2172 Email: Tropicac@msn.com Design Conditions Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature(°F) 70 75 Elevation: 43 ft Design TD(°F) 35 16 Latitude: 30°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 8.4 52.8 Dry bulb(°F) 35 91 Infiltration: DaiIyrange(°F) - 17 ( M ) Method Simplified VVL-tbulb(°F) - 77 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 Component Btuh1W Btuh %of load Walls 3.4 2627 21.1 D,&s Glazing 19.7 1298 10.4 v0s Doors 13.5 425 3.4 Ceilings 1.7 1102 8.8 Floors 4.1 2693 21.6 ---llfiltrm Infiltration 3.0 2602 20.9 C3aarg Ducts 1711 13.7 Piping 0 0 Gras Humidification 0 0 CelugsR Ventilation 0 0 CJS Adjustments 0 Total 1 1 12458 100.0 Component Btu h/ft2 Btuh %of load Walls 2.6 2042 16.5 Inte-d C33ns Glazing 48.3 3180 25.6 V1dls, Doors 11.4 360 2.9 Ceilings 2.1 1363 11.0 Floors 2.0 1269 10.2 D-ds Infiltration 0.7 636 5.1 Ducts 1896 15.3 Ventilation 0 0 Gama Internal gains 1660 13.4 Infiltration Blower 0 0 Boors Adjustments 0 DDOrse Total 1 1 12406 100.01 Ceilings Latent Cooling Load=2161 Btuh Overall U-value=0.182 Btuh/ftz-°F Data entries checked. _ WPI htsoft 2013-Feb-25074740 +- 9 Rig Universal2012 12.1.05 Right J®Mobile Pagel C:\WINDOWS\TEMP\wstmp\17fOc2d7-8t7d-4609-9473-fe2fa37dO86a.rup Calc=MJ8 Front Door faces: E Right-M Worksheet Job: Petway am, Entire House Date: 2/25/2013 wu tla�wMr•• By: AL 1 Room name Entire House Second Floor 2 Exposed wall 110.0 It 110.0 It 3 Room height 8.0 It d 8.0 ft heat/cool 4 Room dimensions 1.0 x 650.0 It 5 Room area 650.0 ft' 650.0 ft' T Construction U-value Or HTM Area ft' Load Area (ft') Load number (Btuh/ft2-°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6y/ 12B-Osw 0.097 n 3.36 2.61 160 116 389 303 160 116 389 303 1 D-c2ow 0.570 n 19.72 20.91 13 0 247 261 13 0 247 261 11 DO 0.390 n 13.49 11.43 32 32 425 360 32 32 425 360 yl 12B-Osw 0.097 a 3.36 2.61 280 259 870 676 280 259 870 676 1 1 t--c 1 D-c2ow 0.570 a 19.72 63.01 21 0 411 1313 21 0 411 1313 12B-Osw 0.097 s 3.36 2.61 160 148 498 387 160 148 498 387 1 D-c2ow 0.570 s 19.72 25.16 12 0 230 293 12 0 230 293 12B-Osw 0.097 w 3.36 2.61 280 259 870 676 280 259 870 676 1 D-c2ow 0.570 w 19.72 63.01 21 0 411 1313 21 0 411 1313 C 16C-19al 0.049 1.70 2.10 650 650 1102 1363 650 650 1102 1363 F 19A-Obsto 0.368 4.14 1.95 650 650 2693 1269 650 650 2693 1269 6 c)AED excursion 01 10 Envelope loss/gain 1 8145 8214 1 1 8145 8214 12 a) Infiltration 2602 636 2602 636 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 2 460 Appliances/other 1200 1200 Subtotal(lines 6 to 13) 10747 10510 10747 10510 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 10747 10510 10747 10510 15 Duct loads 16% 18% 1711 18 89 96 16% 18% 1711 16 1 1 Total rrUomdl adn) I 1 1 125581 1241 5061 1 1 125581 125061 Air 41 41 41 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft 2013-Feb-2507:47:40 Right-Suite®Universal 2012 12.1.05 Right J®Mobile Pae 1 - C N, C:\WINDOWS\TEMP\wstmp\17fOc2d7-8f7d-4609-9473-fe2fa37d086a.rup Calc=MJ8 Front Door faces: E g Component Constructions Job: Petway Date: 2/25/2013 Entire House By: AL For: Ty Petway,Tropic Heating&AirConditioning,lnc. 1911 Beach Ave.,Atlantic Beach, FL 32233 Phone: 904-241-1788 Fax: 904-241-2172 Email:Tropicac@msn.com Design Conditions Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature(°F) 70 75 Elevation: 43 ft Design TD(°F) 35 16 Latitude: 30°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 8.4 52.8 Dry bulb(°F) 35 91 Infiltration: Dailyrange(°F) - 17 ( M ) Method Simplified VAktbulb(°F) - 77 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft' BtuhA?-'F f'-'F/Bhfi BluhM Btuh BWhftr Btuh Walls 1213-0sw.Frm wall,vnl ext,r-11 cav ins, 1/2"gypsum board int n 116 0.097 11.0 3.36 389 2.61 303 fnsh,2"x4"wood frm a 259 0.097 11.0 3.36 870 2.61 676 s 148 0.097 11.0 3.36 498 2.61 387 W 259 0.097 11.0 3.36 870 2.61 676 all 783 0.097 11.0 3.36 2627 2.61 2042 Partitions (none) Windows 1 D-clow.2 glazing,clr outr,air gas,wd frm mat,dr innr, 114"gap, n 13 0.570 0 19.7 247 20.9 261 1/8"thk a 21 0.570 0 19.7 411 63.0 1313 s 12 0.570 0 19.7 230 25.2 293 w 21 0.570 0 19.7 411 63.0 1313 all 66 0.570 0 19.7 1298 48.3 3180 Doors 11 D0:Door,wd sc type n 32 0.390 0 13.5 425 11.4 360 Ceilings 16C-19al:Attic ceiling,asphalt shingles roof mat,r-19 ceil ins, 117 650 0.049 19.0 1.70 1102 2.10 1363 gypsum board int fnsh Floors 19A-Obstp:Fir floor,wd fir,1"thkns,tile flr fnsh,tight bsmt ovr 650 0.368 0 4.14 2693 1.95 1269 2013 Feb-25 07:47:40 WrightSotl't' Right-Suite®Universal 2012 12.1.05 Right J®Mobile Page 1 ACCK C:\WINDOWS\TEMP\w4tmp\17fDc2d7.8f7d-4809-9473-fe2fa37d086a.rup Calc=MJ8 Front Door faces: E AED Assessment Job: Petway I Date: 2/25/2013 Entire House By: wlt•c«w 10 I'M AL Project Information For: Ty Petway, Tropic Heating&AirConditioning,lnc. 1911 Beach Ave.,Atlantic Beach, FL 32233 Phone: 904-241-1788 Fax: 904-241-2172 Email: Tropicac@msn.com Design Conditions Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature(°F) 70 75 Elevation: 43 ft Design TD(°F) 35 16 Latitude: 30°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 8.4 52.8 Dry bulb(°F) 35 91 Infiltration: Dailyrange(°F) - 17 ( M ) Wet bulb('F) - 77 Wind speed (mph) 15.0 7.5 Test for • ' • Exposure Diversity HourlyGlazing Load 4,00 - 3,50 3,00 2,50 2,00 1 ,50 1 ,00 50 0 8 9 10 11 12 13 14 15 16 17 18 19 20 Hour of Day / Hwdy A,erage 4EDIirnit Maximum hourly glazing load exceeds average by 20.6%. House has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh i + WPI htsoft 2013-Feb-2507:47:40 9 Right-Suite®Universal 2012 12.1.05 Right J®Mobile Page 1 AXA C:\WINDOWS\TEMP\wstmp\17fOc2d7-8f7d-4609-9473-fe2fa37dO86a.rup Calc=MJ8 Front Door faces: E