Loading...
Permit HVAC 2233 Barefoot Trac 2013 sf,f 1f J� CITY OF ATLANTIC BEACH j 800 SEMINOLE ROAD +) a ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 �Jf3 r Application Number . . . . . 13-00002229 Date 2/27/13 Property Address . . . . . . 2233 BAREFOOT TRAC Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 3600 ---------------------------------------------------------------------------- Application desc REPLACE 1 CU 1 AHU ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ SCROGINS WILLIAM C & VALERIE A DONOVAN HEATING & AIR 2233 BAREFOOT TRAC 315 SIXTH AVENUE SOUTH ATLANTIC BEACH FL 322334565 JACKSONVILLE BEACH FL 32250 (904) 241-3785 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . 1 CU 1 AHU Permit Fee . . . . 95 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 8/26/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 95 . 00 95 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 99 . 00 99 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL.PERmff APPLICATION Cffy OF ATLANTIC BEACH 800 seminole lid Atlantic Beach,FL 32233 Ph(904)247-5926 Fax(904)247»5845 JOB ADDRESS: 60=1d -22A� PERMU# PROJECTVALLUES NEW AIR CONDITIOM NG&HEATING SYSTEM INSTALLATION Air Conditioning: UMt QuantitY Tans Per.Usk Hest: Unit Quantity BTU's Per Unit� Seer Ratin g Duct Systems: Total CFM ,REQUI EED REPLACEMENT AIR CONDI'T'IONING &HEATING SYSTEM INSTALLATION Air CouditionbW Unit Quau* . ___ Tons Per Unit 2' Q Heat Unit Quantity,__.L� BTU's Per Unit rlm Seer Duct Systems: Tonal CFM __ "QURED FARE PREVENTION Fire Sprinkler System Quatrtity (Requires,3 sed of plows) Fire Stand pip� Quantity (Requires3 sets of plans) Undergroun!�.Fire Main Value (Regal rw 3 sets of plans) Fire Hose Cabinets Quantity (Re9uim 3 sets of plans) Commercial Hoods Quantity (Requilrts 3 sets of plans) Fire' SuppraesSion Sysfe�4 Quantity (Requires 3'}sets of plans) FIRE PLACES AUS L EOUS: Prefatincabed Fireplace Qty Automobile Lifts Gas Piping oudeb Boilers BTU's Elevators/Escalators ALL OTIMR GAS PIMG Heat Lxchenger Quantity of outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heateirs Solar Collection Systems Tanks(gauclus) Wells OTHER: Permit becomes void Twork does not commence within a sic month period or work is sm%mded or abandoned for six months I hereby certify that I have read fits application mad know the sameto be true and cmVOM All pmvWoos of laws mod ordinances govemiogthis work wit!be coxeplied with w1wMer spcdSod n not, The permit does not give m 0lority to violate the provisions of any other state or local low regulation con=csou or the per*rmmtec of constmcflon. 'rWerty Chest=Naive &I OPhone Number 9(lV l o?yp lyo l &cbanical Compmw I L-Njc�n a- f►rL Office Phone Stt(-3-)KEFwr,_ I~31`5 :o.Address= i S, City c) Kcb. Stft fL,—Zxp Acense Holder(Print): , l VA var, Stam Cerlifica*w)Registration#_ G44v3`1-)61 �arr�rd S'�gnar�ur+e o,f'X.�,�e�se.�Qr Sworn and subsl`bed berme me thiso�� day of re 4 20 f; Notary Public State at Florld2 STg'113tm 4f NfJta1'fr PUl?l1C h. Timothy 1-0e Hughes My Cammi®�IOR EE 188279 �esn,� (:xpiros��J2t)16 Job: Date26.2013 ; r-abruBN Project Summary 13y- Aaron Traeker �41 �nrrightso Entire Hous Donovan Heat& Air Hench Ff.322'.�Phcnn:Qtl�41.3755 lex:9047A1-3745 pma4:aas'°n�dnnmranAc.Rwww.Dtlno•+t►nAC.R°t'tt 315 Bln pye$, Igcksonvill8 • For' Bill Scroggins race, Atlantic Beach, FL 32233 2232 Barefoot Notes; ulleathor' Jacksonville Mayport Naval, FL, US Summer Design Conditions winter Design conditions 6 Outside db ° 39 of 75 F outside db 70 p Inside db OF 2L Inside db 31 OF Design n 50 Design TD Deily range 53 gr/lb humidity Moisture difference Sensible Cooling Equipment Load Sizing Heating Summary 15282 Btuh 11282 Btuh Structure 4753 Btuh Structure 3353 Btuh Ducts 0 Btuh Central vent(0 ctm) p Btuh Ducts0 Btuh Blower Central vent (p cfm) 0 Btuh n Humidification 0 Btuh Use manufacturer's data 1.00 piping 14636 Btuh R �$wing mu4tipHer 20015 Btuh Equipment load Equipment sensible load infiltrationul Equipment Load Sizing Simplified Latent Cooling q p 2253 Btuh Method quality Average Structure 1014 Btuh Construction q Ducts 0 Btuh Fireplaces Central vent(0 cfm) 3267 Btuh HeatingCO llil Equipment latent load Area(ft 1916 11916 23282 Btuh Volume?ft ) 11 .45 0.23 Equipment total load 2.,4 tort Air changeslhour 0.45 46 Req. total capacity at 0.70 SHR Equiv.AVF(cfm) 89 � ui meat Summary Cooling Equipment Summary Heating Q P Make Carrier Make Carrier Trade BASE 13 PURON*�0 Trade BASE 13 PURON H :230A,W) P Cond 25WB Madel 25HRC330(A,1M"*30 Coll FB4CNF03� AHRI ref nc3699497 AHRI ref no3699497 11.0 EBR, 13 SEER Efficient+ Sensible cooling 7.7 HSPF Efficiency 21000 Btuh � 9000 Btuh Heating input 30000 Btuh @ 47°F r stent cooling Heating output Temperature rise 27 OF Total cooling 300013 Btuh Actual air flow 1000 cfm Actual air flow 1000 cfm Air flow factor 0,068 cfm/Btuh Air flow factor 0.050 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermvst2lt Load sensible heat.ratio 0.16 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrfghtSoft" Right-RullrM UAIVI eai 5.0,24 RSU05995 2013•1-eb-28 16:38.23 .d A C:1Unor10wnm%DocumenttlWrtghtnnit HVAC19oguR 2,a ton.rup Cgs'IRJe Ffl7�l DOOI�ACBS; W fop 1