Loading...
439 Irex Rd mech 2013 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 ills) Application Number . . . . . 13-0000229S Date 3/11/13 Property Address . . . . . . 439 IREX RD Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ WELLS FARGO BANK NA HUXHAM HEATING & AIR P 0 BOX 2248 2101 FLORIDA BLVD. MAIL CODE Z30S7-010 NEPTUNE BEACH FL 32266 JACKSONVILLE FL 32203 (904) 246-6721 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 95 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 9/07/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 9S . 00 95 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 99 . 00 99 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax (904) 247-5845 JOBADDRESS: tj'2,� PERmrr# PROJECTVALUE $ — ARI# REQUIRED NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quant�ty Tons Per Unit AS- Heat: Unit Quantity BTU's Per Unit N9912 Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity I BTU'sPerUnit 3o,ocb Seer Ratin Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty_ Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's 9 Water Heaters Solar Collection Systems Tanks(gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that 1 have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. 'Me permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name Phone Number Office Phone9lko--09( Fax— Mechanical Company Co. Address: 9,�Ok city State r4 zip3�246 License Holder(Print): _7�pr� (S--�A State Certification/Registration Notarized Signature ofLicense Ho 2 0 NdM Wubsc bed befo in S f OMMIC, MM I 0,S)I DD 957760 "Ic EX S:: ru ...... Bonde Publi t4?t Job: 31013 Project Summary Date: Mar 10,2013 RODRIGUZI.- Entire House By: ERIN RODRIGUEZ enerqv wnsulting Proiect Information For: WEBB 439 IREX ROAD,ATLANTIC BEACH, FL 32233 Notes: HUXHAM -CHANGE OUT Design Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 'F Outside db 92 'F Inside db 68 'F Inside db 76 'F Design TD 29 'F Design TD 16 'F Daily ran e L Relative?lumidity 50 % Moisture difference 56 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 18768 Btuh Structure 15954 Btuh Ducts 3963 Btuh Ducts 5661 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 22731 Btuh Use manufacturer's data n Rate/swing multiplier 0.97 Infiltration Equipment sensible load 20966 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1269 Btuh Ducts 1409 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft2) 1087 1087 Equipment latent load 2678 Btuh Volume (ft') 8693 8693 Air changes/hour 0.45 0.23 Equipment total load 23645 Btuh Equiv.AVF (cfm) 65 33 Req. total capacity at 0.70 SHR 2.5 ton Heating Equipment Summary Cooling Equipment Summary Make Trane Make Trane Trade XR13 WEATHERTRON Trade XR13 WEATHERTRON Model 4TWR303OC1 Cond 4TWR303OC1 AHRI ref no.5270753 Coil GAM5AOB3OM21 AHRI ref no.5270753 Efficiency 8.5 HSPF Eff iciency 12.0 EER, 13 SEER Heating input Sensible cooling 21000 Btuh Heating output 28000 Btuh @ 47'F Latent cooling 9000 Btuh Temperature rise 25 'F Total cooling 30000 Btuh Actual air flow 1000 cfm Actual air flow 1000 cfm Air flow factor 0.044 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat Load sensible heat ratio 0.89 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 2013-Mar-11 08A7 42 A- + wrightSOft Right-Suite,8 Universal 2012 12.0.07 RSU01508 Pagel sers*rin\[)ocunients\WrightsoftHVAC\Template\HUXRAM-WEBB rup Calc=MJ8 Front Door f-aoes: moommo���- A LAIM I" will CERTIFIEDT. Lw w w.a h r i d i r e c t o r y.a r g Certificate of Product Ratings AHRI Certified Reference Number: 5270753 Date: 3/11/2013 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 4TWR303OC1 Indoor Unit Model Number: GAM5AOB3OM21 Manufacturer: TRANE Trade/Brand name: XR13 WEATHERTRON Manufacturer responsible for the rating of this system combination is TRANE Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity(Btuh): 30000 EER Rating (Cooling): 12.00 SEER Rating (Cooling): 14.50 Heating Capacity(Btuh)@ 47 F: 28000 Region IV HSPF Rating (Heating): 8.50 Heating Capacity(Btuh)@ 17 F: 16100 Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory atwww.ahridirectory.org. TERMS AND CONDITIONS This Certilficate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION ri www.ahridirectorY.org, A' C nditioning,Heating, The information for the model cited on this certificate can be ve fied at click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on On ILI n"d Roefrigeration Institute which the cerfificate was issued,which is listed above,and the Certificate No.,which is listed below. @2012 Air-Conditioning,Heating,and Refrigeration Institute CERTIFICATE NO.: 130074908025288525