2002 Colina Ct 2013 HVAC CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 r !tit Application Number . . . . . 13-00002323 Date 3/20/13 Property Address . . . . . . 2002 COLINA CT Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ Meyer, Mark WAYCHOFFS AIR CONDITIONING 1326 Atlantic Avenue 6929 PHILLIPS PARKWAY DR S FERNANDINA BEACH FL 32034 JACKSONVILLE FL 32256 (904) 838-9052 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 107 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 9/16/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 107 . 00 107 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 111 . 00 111 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, Fl, 32233 Ph(904)247-5826 Fax (904) 247-5845 JOB ADDRESS: 0,/U —PERMIT PROJECTVALUE $. yVV ZO—P NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION ARI#_y 6Lj1&,0� Air Conditioning: Unit Quantity Tons Per Unit REQUIRED Heat: Unit Quantity BTU's Per Unit Seer Ratil�g'--Ap— Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty_ Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators �LL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's 4 Water Heaters Solar Collection Systems Tanks (gallons) Wells )THEIR: 6"&1 llnyta-& fiZA-1 I AUAIP _S�d IFEM w1a CC -Z�XZ =it becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read is application and know the same to be true and correct All provisions of laws and ordinances governing this work will be complied with whether specified not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. .-operty Owners Name Phone Number 40 0 z 1//- 6,?y V, .echanical Company Office Phone&6755�5FaxE&LY�5_d ). Address: Alllltl�os Arktuav Z&- S city Y- State �� Zip 322d 7L, .cense Holder(Print): P-;l7,hl2 r d 4)a — State Certifi ati egistration# 6yC11?1399 Varized Signature ofLicense Ho r JENNFER LYNN and subscribed be e in t s av Of 20_a EE15r -0i My COMMMION 0 EE15"M tu rol re of Notary Publi EXPffS0wwW01.2N& (4n Job: + wrightsoft Right J@ Mobile Report Date: 3111/2013 Entire House By- AL Project Information For: Mark Meyer 2002 Colina Ct., Atlantic Beach,, FL 32233 Phone: 904-241-6294 Desiqn Conditions Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature(oF) 70 75 Elevation: 43 ft Design TD('F) 35 16 Latitude: 30'N Relative humidity 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 8.4 52.8 Dry bu I b('F) 35 91 Infiltration: Da i ly range('F) - 17 M Method Simplified V\Iet bulb('F) - 77 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Heating Component Btu h/ft' Btuh % of load Walls 3.4 5289 15.8 VAIS DjJs Glazing 19.7 5571 16.6 Doors 13.5 425 1.3 Ceilings 1.7 3179 9.5 k-itk-dbcn Floors 5.3 9867 29.5 Owing Infiltration 2.1 4061 12.1 Ducts 5074 15.2 Uff-�3- Piping 0 0 Humidification 0 0 Odfirgms R= Ventilation 0 0 Adjustments 0 Total 33467, 100.0 Component Btu h/ft' Btu h % of load Walls 1-5 2370 8.7 \A/Als Intal Gains Glazing 42.0 11870 43.5 Doors 11.4 360 1.3 Ceilings 2.1 3932 14.4 D-ds Floors 0 0 0 Infiltration 0.5 1007 3.7 Ducts 5881 21.5 Ventilation 0 0 Gwrg Infiltraticrt Internal gains 1890 6.9 Blower 0 0 Iceilings Adjustments 0 CthEr Total 27310 100.0 Latent Cooling Load 3414 Btuh Overall U-\oa lue=0.125 BtLih/ft-'F Data entries checked. 2013-Mar-1 1 09:20:52 .:t.= + wrightSOft Right-S.itee Universal 2012 12.1.05 Right JO Mobile Page 1 Jlllc(�K C:\WNDOWS\TEMP\wstmp\6aO22386-0110-4b27-Bc24-el82dlab3890.rup Calc=MJ8 Front Doorfaces: N Project Summary Job: + wrightsoft Date: 311112013 Entire House By: AL Project Information For: Mark Meyer 2002 Colina Ct., Atlantic Beach,, FL 32233 Phone: 904-241-6294 Notes: Design Information Weather: Jacksonville/Craig, FL, US Winter Design Conditions Summer Design Conditions Outside db 35 'F Outside db 91 oF Inside db 70 'F Inside db 75 oF Design TID 35 'F Design TID 16 'F Daily range M Relative humidity 50 % Moisture difference 53 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 28393 Btuh Structure 21429 Btuh Ducts 5074 Btu h Ducts 5881 Btuh Central vent(0 cfm) 0 Btu h Central vent(0 cfm) 0 Btuh Humidification 0 Btu h Blower 0 Btuh Piping 0 Btu h Equipment load 33467 Btu h Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 27310 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2617 Btuh Ducts 797 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft2) 1875 1875 Equipment latent load 3414 Btuh Volume (ft) 16875 16875 Air changes/hour 0.38 0.20 Equipment total load 30724 Btuh Equiv.AVF (cfm) 107 56 Req. total capacity at 0.70 SHR 3.3 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref Efficiency 0 AFUE Efficiency 0 SEER Heating input 0 MBtuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 'F Total cooling 0 Btu h Actual air flow 1192 cfm Actual air flow 1192 cfm Air flow factor 0.036 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat Load sensible heat ratio 0.89 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-Mar-11 09:20:52 vvrightSOft Right-SuiteOD universal 2012 12.1.05 Right JO Mobile Page I ACCk C\VANDOWS\TEMP\wstmp\6aO22386-0110-4b27-8c24-el82diab3890.rup Calc=MJ8 Front Door faces: N + wrightsoft Right-JO Worksheet Job: Entire House Date: 311112013 By: AL 1 Room name Entire House First Floor 2 Exposed wall 2100 ft 210.0 ft 3 Room height 9.0 ft 9.0 ft heat/cool 4 Room dimensions 1.0 x 1875�O ft 5 Room area 1875.0 ft2 1875.0 ft2 Ty Construction Uuvalue. HTM Area (W) Load Area (f,!t�) Lo d number (13t h/H2 F) or (13t uh/f t�) or perimeter (ft) I I ( (ft) (Eita (Btuh or penme er uh Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat 6 V" 112B-Ob 0.097 n 136 1.50 495 421 1412 633 495 421 1412 633 D-c2ow 0570 n 19.72 20.91 74 0 1463 1551 74 0 1463 1551 VL2B-Ob 0.097 e 3.36 1.50 450 351 178 528 450 351 178 528 —G 11D-c2ow 0570 e 1972 63.01 68 0 11331 4253 68 0 11331 4253 11 11DO 0.390 e 1149 11.43 32 32 425 360 32 32 425 360 1 213-Obw 0.097 s 3.36 1.50 495 421 1412 633 495 421 1412 633 t--" I D-c2ow 0570 s 1972 2516 74 0 1 463 1866 74 0 1 463 1866 1213-0bw 0097 w 336 1.50 450 383 1287 576 450 383 1287 576 1 D-c2ow 0.570 w 19.72 63.01 67 0 1315 4200 67 0 1315 4200 C 16C-19al 0049 1.70 2.10 1875 1875 3179 3932 1875 1875 3179 3932 F 22A-coh 1.358 46.99 0.00 1875 210 9867 0 1875 210 9867 0 1 61 c)AED excursion 1 01 1 1 1 Envelope loss/gain 1 243321 185321 1 243321 1 12 a) Infiltration 4061 1007 4061 1007 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 3 690 3 690 Appliances/other 1200 1200 Subtotal(lines 6 to 13) 28393 21429 28393 21429 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 28393 21429 28393 21429 15 Duct loads —18%—T275074 5881 18% 27% 5074 5881 1 Total room load 334671 273101 1 1 33467 1 273101 Air required(cfm) 1192 1192 1192 1192 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-Mar-1 1 09 20:52 Right-Suite(D Universal 2012 12.1.05 Right JO Mobile Page 1 C:\WNDOWS\TEMP\wstmp\6aO22386-0110-4b27-8c24-el82dlab3890.rup Calc=MJ8 FrontDoorfaces: N Component Constructions Job: + wrightsoft Date: 3/11/2013 Entire House By: AL Project Information For: Mark Meyer 2002 Colina Ct.,Atlantic Beach,, FL 32233 Phone: 904-241-6294 Design Conditions Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature (T) 70 75 Elevation: 43 ft Design TD (T) 35 16 Latitude: 30 oN Relative humidity 30 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 8.4 52.8 Dry bulb(T) 35 91 Infiltration: Da i ly range(T) - 17 M Method Simplified Wet bulb(oF) - 77 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area Ll-value Insul R Htg HTIVI Loss Cig HTM Gain ft2 Bth/ft2-'F fF-'F/Btuh Btuh/ft2 Btuh Btuh/W Btuh Walls 1213-Obw�Frrn wall,brk 4"ext,r-1 I cav ins, 112"gypsum board int n 421 0.097 11.0 3.36 1412 1.50 633 fnsh,2"x4"wood frm e 351 0.097 11.0 3.36 1178 1.50 528 s 421 0.097 11.0 3.36 1412 1.50 633 w 383 0.097 11.0 3.36 1287 1.50 576 all 1576 0.097 11.0 3.36 5289 1.50 2370 Partitions (none) Windows 1 D-c2ow:2 glazing,clr outr,air gas,wd frm mat,clr innr, 1/4"gap, n 74 0.570 0 19.7 1463 20.9 1551 1/8"thk e 68 0.570 0 19.7 1331 63.0 4253 s 74 0.570 0 19.7 1463 25.2 1866 w 67 0.570 0 19.7 1315 63.0 4200 all 282 0.570 0 19-7 5571 42.0 11870 Doors 11 DO:Door,wd sc type e 32 0.390 0 13.5 425 11.4 360 Ceilings 16C-19al:Attic ceiling,asphalt shingles roof mat,r-19 ceil ins,1/2" 1875 0.049 19.0 1.70 3179 2.10 3932 gypsum board int fnsh Floors 22A-cph:Bg floor,heavy damp soil,on grade depth,carpet flr fnsh 210 1-358 0 47.0 9867 0 0 2013-Mar-1 1 09:20:53 ,:tn + w rightSOft Right-SuiteO Universal 2012 12.1.05 Right JS Wbile Page 1 A--Ck C\VnNDOWS\TEMP\wstmp\6aO22386-011OAb27-gc24-el82dlab3890+rup Calc=MJ8 FrontDoorfaces: N AED Assessment Job: + wrightsoft Date: 3/11/2013 Entire House By: AL Project Information For: Mark Meyer 2002 Colina Ct.,Atlantic Beach,, FIL 32233 Phone: 904-241--6294 Design Conditions Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature(T) 70 75 Elevation: 43 ft Design TD(T) 35 16 Latitude: 30'N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 8.4 52.8 Dry bul b(T) 35 91 Infiltration: Da i ly range(T) - 17 M VVet bulb('F) - 77 Wind speed(mph) 15.0 7.5 Test for Adequate Exposure Diversity Hourly Glazing Load 16,OOE- 14,OOC- 12,OOC- 10,00(l- 8,OOC��� 6,OOC- 4,OOC- 2,OOC- 0 + i t 8 9 10 11 12 13 14 15 16 17 18 19 20 Hour of Day Hxfly Aerage AEDlinit Maximum hourly glazing load exceeds average by 19.0%. House has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh 2013-Mar-1 1 09:20:53 wrightSOft Right-Suite@ universal 2012 12.1.05 Right JO Wbile Page 1 X--Cb, C\VANDOWS\TEmp\wstmp�6aO22386-01 1G-4b27-8c24-e182d1ab3890.rup Calc=MJ8 Front Door faces: N k N First Floor First Floo F--j Job#: Scale: 1 : 92 Performed for: Pagb 1 Mark Meyer Right-Suite(@Universal 2012 2002 Colina Ct. AL 12-1.05 Right JOMoble Atlantic Beach-FL 32233 2013-Mar-11 09:20:53 Phone:904-241-6294 ...-0110-4b27-8c24-el82dlab3890.rup Way off' s Air Conditioning "Leading the Way in Home Comfort� L- 6929 Phillips Parkway Drive South, Jacksonville, FL 32256 (904) 880-5525 Voice - (904) 880-5527 Fax To: From: AaAw Company.� U &6, &&, &i Cell: Fax: Pages: .k&"4,� &,ey) Phone: Date: AX-113 Re: CC: 0 Urgent q�For Review 0 Please Comment 11 Please Reply 11 Please Recycle 0 Comments: ,Xw A/ im) &Utl-- //- t:&2� a4i L/ f Amd 7 4 Z-1 .4 Thank you!