347 7th St 2013 HVAC CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00002379 Date 3/27/13 Property Address . . . . . . 347 7TH ST Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ ANDERSON DAVID L & JOYCE ONE HOUR AIR 347 7TH ST 1015 ATLANTIC BLVD #249 ATLANTIC BEACH FL 322335433 ATLANTIC BEACH FL 32233 (904) 222-8482 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 95 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 9/23/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 95 . 00 95 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 99 . 00 99 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. wrightsoft-, Project Summary Job: 122187 Date: 3127/2013 Entire House By: CRAIG EDDY ONE HOUR AIR 1198 MAYPOR I RD#1,,,1 LANTIC BEACH.FL 32233 Phone:904-241-3107 Fax:904-247-5526 License:CAC1814420 Project Information For: DAVEANDERSON 347 7TH ST,ATLANTIC BEACH, FL 32233 Phone: 246-0245 Notes: Design Information Weather: Jacksonville/Craig, FL, US Winter Design Conditions Summer Design Conditions Outside db 35 'F Outside db 91 'F Inside db 70 *F Inside db 75 *F Design TD 35 *F Design TD 16 oF Daily range M Relative humidity 50 % Moisture difference 53 gr1lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 25800 Btuh Structure 23070 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfrn) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 25800 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 23070 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2678 Btuh Ducts 0 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft� 1344 1344 Equipment latent load 2678 Btuh Volume(ft3) 10752 10752 Air changes/hour 0.45 0.23 Equipment total load 25748 Btuh Equiv.AVF (cfm) 81 41 Req.total capacity at 0.76 SHR 2.5 ton Heating Equipment Summary Cooling Equipment Summary Make GOODMAN Make GOODMAN Trade AMANA DISTINCTIONS Trade AMANA DISTINCTIONS Model GSZ1 30301 Cond GSZ130301 AHRI ref 4248571 Coil ASPF183016 AHRI ref 4248571 Efficiency 0 HSPF Efficiency 14SEER Heating input Sensible cooling 21612 Btuh Heating output 0 Btu h @ 47'F Latent cooling 6788 Btuh Temperature rise 0 'F Total cooling 28400 Btuh Actual air flow 1050 cfm Actual air flow 1050 cfm Air flow factor 0.041 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat Load sensible heat ratio 0.90 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-Mar-27 09:56:09 wrightSOft' Right-Suite4D universal 2012 12.1.06 Right J8 Mobile Page 1 Nwstmp\Odd�j7Olc-92f5-4b6d-bl9e-lf48ce58dbde.rup Calc=MJ8 FrontDoorfaces: S MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax (904) 247-5845 JOB ADDRESS: 4,-: ' PERMIT# PROJECTVALUE $ ARI# 4f—_�55-71 REQUIRED NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Z& Heat: Unit Quantity BTU's Per Unit SQ ocy­> Seer Rating Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty_ Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Phone Nu Property Owners Name ,5ber(jg4) - - (1�4 - (90q-) Mechanical Company r)��lin X-1 AZ Office Phone 2j41-5i-7Fax 04'7-155� Co. Address: )116 Aj,4�Mby_%`e, Cit tf State 1q" zip License Holder (Print): LoAe, 6:;�' St CertificationJRegistration# t4464014q16 Notarized Signature of License Holder f"PI" tills a of 20 RAHQ M' �r'10N r f Notary Publi Febta,I 1 014 111W."Fhru Notary p blic Uqderw�ters Ulm pow BOILS CERTIFIEDTM www.ahridirectory.org A Certificate of Product Ratings AHRI Certified Reference Number: 4248571 Date: 3/27/2013 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: GSZ130301A* Indoor Unit Model Number: ASPF183016E* Manufacturer: GOODMAN MANUFACTURING CO., LP. Trade/Brand name: GOODMAN, JANITROL, AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR CONDITIONING AND HEATING, ENERGI AIR Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP. Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity(Btuh): 28400 EER Rating (Cooling): 11.30 SEER Rating (Cooling): 14.00 Heating Capacity(Btuh) @ 47 F: 26400 Region IV HSPF Rating (Heating): 8.20 Heating Capacity(Btuh) @ 17 F: 16000 Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out ofthe use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION The information forthe model cited on this certificate can be verified atwww.ahridirectory.org, 04 "IMP, click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on rA Air-Conditioning,Heating, which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. AM On ILE and Refrigeration Institute (D2013 Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 130088797329323514