Loading...
1890 Beach Ave 2013 HVAC CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 jilt Application Number . . . . . 13-00002366 Date 3/26/13 Property Address . . . . . . 1890 BEACH AVE Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ SUMNER WILLIAM D & DEBORAH F DONOVAN HEATING & AIR 1890 BEACH AVE 315 SIXTH AVENUE SOUTH ATLANTIC BEACH FL 322335939 JACKSONVILLE BEACH FL 32250 (904) 241-3785 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 99 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 9/22/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 99 . 00 99 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 103 . 00 103 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE NVITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. This combination qualifies for a Federal Energy Efficiency Tax Credit when placed in service No ILI CERTIFIEDT. between Feb 17, 2009 and Dec 31, 2013. www.ahridirectory.org 'A Ceftificate of Product Ratings AHRI Certified Reference Number: 3676268 Date: 3/26/2013 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 25HCC536A**30 Indoor Unit Model Number: FX4DN(B,F)037 Manufacturer: CARRIER AIR CONDITIONING Trade/Brand name: PERFORMANCE 15 PURON HP Manufacturer responsible for the rating of this system combination is CARRIER AIR CONDITIONING Rated as follows in accordance with AHRI Standard 2101240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity(Btuh): 34800 EER Rating (Cooling): 12.50 SEER Rating (Cooling): 15.00 Heating Capacity(Btuh)@ 47 F: 34400* Region IV HSPF Rating (Heating): 8.50* Heating Capacity(Btuh)@ 17 F: 22000 Ratings followed by an asterisk(')indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized afterabon of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org, Air-Conditioning,Heating, click on"Verity Certificate"link and enter the AHRI Certified Reference Number and the date on A00U and Refrigeration Institute which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. @2013 Air-Conditioning,Heating,and Refrigeration Institute CERTIFICATE NO.: 130087860200642556 MECHANICAL PERMIT APPLICATION CITY OFATLANTIc BEACH 800 Seminole Rd Atlantic Beach,FL 32233 Ph(904)247-5826 Fax(904)247-5845 JOB ADDREss: —j eqo t7nr A Avc PERMIT# PROJECTVALUE$ NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons per.Unit Heat: Unit Q!!��ItitY BTU's Per Unit Duct Systems: Total CFM Seer RE, D REPLACEMENT AIR CoNiDMONING & HEATING SySTEM IN Tj N AR Air Conditioning: Unit Quantity I 3&Z z0v �. �z J�70 Heat: Tons Per Unit 3 Unit Quantity BTU's Per Unit--- Duct Systems: Total CFM I�P-0-0 Seer Rating 1',.- REQUDZED FIRE PREVENTION Fire Sprinkler System Quantity Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of pLims) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty_ Automobile Lifts Gas Piping Outlets Boilers BTU's ALL OTHER GAS PIPING Elevators/Escalators Quantity of Outlets Heat Exchanger 4 Vented Wall Furnaces Pumps #Water Heaters Refrigerator Condenser BTU's Solar Collection Systems Tanks(gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or w rk is suspended or abandoned for six months.I hereby certify that I have read Ms application and know the same to be true and correcL All provisions of iawsoand ordinances governing this work will be complied with whether specified )r not. lie permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction- ?rOPerty Owners Name I )r e- G(-1 th r)V-y/, PhoneNumber ?-Z � - 9-3g-j qechanical Company -(:�Ov6/i tl7tf t---+- Office Phone V-1(-3)KS-Fax Z�j 1-3-79S- . o-Address: LI��' /,ve- -S, — City 0 e -GA04 c k -State C Zip Acense Holder(Print): oar,*VC-n State Certification/Registration# Votarized Signature of License Holder Sworn and subscribed before me this day of old W 20 1Z_ Signature of Notary Public 40 0.4�, Notary PutAic State of F Ma R Tknothy Lee Hughes My Cornmasion EE 186278 %Td; Expires 04103/2016 EREJ Job: + wrightsoft, Project Summary Date: March 11,2013 Entire House By: Aaron Thacker Donovan Heat& Air 315 6th Ave S,Jacksonville Beach, FL 32250 Phone:904-241-3785 Fax 904-241-3745 Email:aaron@donovanac.com Web:www.DonovanAC.com Project Information For: Debbi Sumner 1890 Beach Ave, AtlanticBeach, FL 32233 Notes: Design Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 OF Outside db 95 OF Inside db 70 OF Inside db 75 OF Design TD 31 OF Design TD 20 OF D a,,y range L Relative humidity 50 % Moisture difference 53 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing StrUCtUre 26705 Btuh Structure 20836 Btuh Ducts 4986 Btuh Ducts 4854 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 31690 Btuh Use manufacturer's data n Rate/swing multiplier 1.00 Infiltration Equipment sensible load 25690 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1154 Btuh Ducts 2085 Btuh Heatin coolin Central vent (0 cfm) 0 Btuh Area (ft') 1040 1040 Equipment latent load 3239 Btuh Volume(ft') 8320 8320 Air changes/hour 0.45 0.23 Equipment total load 28929 Btuh Equiv.AVF (cfm) 62 32 Req. total capacity at 0.70 SHR 3.1 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade COMFORT 15 PURON HP Trade COMFORT 15 PURON HP Model 25HCB536A30 Cond 25HCB536A30 AHRI ref no3676268 Coil FX4DN(B,F)037 AHRI ref no3676268 Efficiency 8.5 HSPF Efficiency 17,0 EER, 15 SEER Heating input Sensible cooling 24920 Btuh Heating output 34400 Btuh @ 47'F Latent cooling 10680 Btuh Temperature rise 26 OF Total cooling 35600 Btuh Actual air flow 1187 cfm Actual air flow 1187 cfm Air flow factor 0.037 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat Load sensible heat ratio 0.89 Calculations approved by ACCA to meet all requirements of Manual J ath Ed. 2013-Mar-26 09:05:06 wrightSOft Right-Suitell)universal 8.0.24 RSU05995 Page 1 ACC'K C\Users\Owner\Documents\Wrightsoft HVAC\Bogus 3 ton.rup Cale=MJ8 Front Door faces: W