1024 Ocean Blvd (revised) 2013 plans P
y a
141 I Q
38'-8" o c7
25 n
•8 13-0r n
LO
—6'-6" 6'-6" to
0
o
I- --------------------�— ----------------- --------------- -----�-
q z
------------------ - - ———————————————— I I ----------_ --
I II
� o
a
I z
I 1 1 I 1 1 I I a 1•- o
S2 S2 I S2 SZ I I o ~ v
I I I I w W >
W ix
I I °
1I I M C')r— --------I--I ! i 0
o
I
I ( ! I I I W 0 CO,
1
- I Q
N I o
S2 -r i I 1 I 1 0
N I ! I I S2 I W z N
I
of
I i I I I I
9 1
10
I I ------ ----- -----I
I I i I
I i I 3 I
I �
S2
I _
S2 I
I
I
N
I
I I
I
to
I
I M
I nz�-10 n
12 { II
I
I
I
W
coI
I
N
I I I II I V N
I'I
I U
- -- --- ———— —— — —————— — I ----- -- -------- --- - - --- s2 11 i � W
► I I
—— —— — ——————— — —— — —— —— ——— — ———— —— —— ——— — —— I I I I I n w w I ' _j 3
ILL
I Q
-1 ! — 30 x30 x12 FOOTING WITH I ' m =
#5 REINFORCEMENT, DRILLED AND EPDXIED USING I I I I I 1 (3)#5 BARS EACH WAY, I I U
Z Q
SIMPSON SET ADHESIVE. MINIMUM EMBEDMENT INTO I i EQUALLY SPACED, I i Z W W m
n II
I I
EXISTING AND PROPOSED FOOTINGS IS 6 .MINIMUM
I I U
I I
U
I
I EDGE DISTANCE OF REINFORCEMENT IS 3".MAXIMUM I I = I I ( I I I U O
HORIZONTAL SEPARATION OF BARS IS 48". I I I { I I I J �/ Z
I I I I 1 3 ! W Q
Q
I I I I 1 I I ! I I Q
I I I I I I I I
I i IN, I-_J
I I I I I 1 !
I I I iv I S2 I
IJ --- --------L— I ------ -----------
----- ----------�
OUNDATION PLAN
I I is I I o v Q o
I I I I
———— ------ --I
' I I i I I
----- ---- ------ --� I 2
I i I 1 I S2 I i z LL
QO
,- --- -- ---- -- --------- J I S2 I I I J o
I I I f I q
I I I I I 2 I I NLL
�— J
iI r---- - ----- -- - --- ------- -- -- J
I I I i I S2 I i li
IO&!j 7LQ y, � _ Q ,
j ! I It Sib ''w`w'
270 �r
4
- -- - - ----- - - -- ' I A 8"x8"THICKENED EDGE Cp/" Y y �,�
—— —— I WITH (1)#4 CONTINUOUS I
1
LL
! I 1,1_
L
_J
I
-Fl— ----I
U. O
4'-8" 9'-2" 1'-9" 9'-0" 2'-3"
V a0 N
13'-10" 13'-0"
CONTINUOUS BOND BEAM WITH 2500 PSI
wa
CONCRETE AND (1)#5 BAR _ a 0
to
va
w C —•t`
CONCRETE SLAB 4 THICK •`0 0
FIBER REINFORCED CO o
U U_U_
UNLESS NOTED OTHERWISE ON PLAN. CONTINUOUS BOND BEAM WITH 3000 PSI
CONCRETE AND (1)#5 BAR
FINISHED GRADE
c� 0
~ N
i N M
-a
8"X16"CMU STEMWALL. STEMWALL o
U
c�
I —
VARIES WITH GARAGE SLOPE .:
a VERTICAL REINFORCEMENT TO BE#5 X �'
DEFORMED BARS AT 48"O.C. FILL ° a
CELLS WITH 3000 psi CONCRETE. i
' ( r
O M '
C —
FIBER REINFORCED CONCRETE SLAB, 4"THICK ? N Y N
_ — UNLESS NOTED OTHERWISE ON PLAN. V
ed U
q • O
ONE STORY: d=8", b-16n, 2)#4 BARS 8 °
TWO STORY: d=10", b=20", (3)#4 BARS a ° b S
( X16 CMU STEMWALL. STEMWALL a� a ° ° w ��/hi
s I ( I ( I � ` r
r AYN
-I I I _ THREE STORY: d=12", b=24", (2)#5 BARS _ VERTICAL REINFORCEMENT TO BE#5 _ a O` '�� ,•• •• �i�'
DEFORMED BARS AT 48 O.C. FILL ° ° y •••• ••• ��
`y
° — d a a a CELLS WITH 3000 psi CONCRETE. —I a °p
a VERTICAL REINFORCEMENT TO HAVE 9 ° —
• 8
° i I Ii I I I • � i
BEND AT BOTTOM AND BE EMBEDDED
° a — I I _III- 6 MIL VAPOR BARRIER OR EQUIVALENT
4" INTO TOP COURSE. a VERTICAL REINFORCEMENT TO HAVE 9" i lI I I WATERPROOFING BETWEEN COMPACTED +' •
d
I — BEND AT BOTTOM AND BE EMBEDDED SUBBASE AND FOOTING/SLAB ••F RI •Ilk, �
— 4" INTO TOP COURSE. 8" X 8" ONE STORY: X=12"WITH(2)#4 .n.. w.., ,, .....'
TWO-STORY: X= 16"WITH(3)#4
b FOOTING TO BEAR ON FIRM FOOTING TO BEAR ON FIRM THREE-STORY:X=20"WITH 3 #5
UNDISTURBED SOIL. O FILE
-ilI II
_ UNDISTURBED SOIL. yl-
@���.�R.10R
Sheet No.
B ARINE G FOOTINGGARAGE STEMWALL FOOT i N G RE`s MD FOR CODE COMPLIANCE STEMWALL DETAIL 2 2
;
fj=::z%TYP1CAL
1 1 0 C SEE PERMTfS FATLANTIC
OR�Ip p��H
C_
1"= 1'-0" REOU1REMEN'�'S AND CONDMONS.
REVMWM DATE: 2 OF 5
This ddocument,togett sr with the concepts d designs presented herein is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document wMxxd written audhortr n by Alexander Grace Consulting,Inc.,shall be without Nability to Alexander Grace Consulting,Inc.