Loading...
335 6th St (vault) PERMIT WORKSHEET Certificate of Occupancyl Job Address: Type Work: 3 3 S b 61 Property Owner: Phone # Contractor: Phone # Permit#: Date Issued: Building Inspections: Footing 1!��c>4 Slab WS4ruchti,j 4rrAiltr, Tie Beam 01 .31 st- -7 Lintel Nailing Sheathing Framing Cover Up Insulation 6-Lq-oq Final Building L,�,2,n,nL[ Tree Permit# YES NO Electrical Permit# Date/ Copy to Z U,It JEA Temp, Pole Permit# Date/ Copy to JEA Temp. Power Letter Received: YES NO Inspections: Rough Electric 6-V,,C4 Released to JEA 5- Temp. Power Released to JEA Temp. Pole Released to JEA G-4-S tJ 61-: 0,4 -031 S 2� Final I C�,-Zcp-C)q Released to JEA 0- Mechanical Permit# C3 � 41 S,7 S --5 Inspections: Rough 1�s-Cp , clj Final Plumbing Permit# tf'7—<�3 Inspections: Rough I Underslab 3-3-0q Topout �s t, 0 Water/Sewer Final I C) --2,o-6t� Drainage Inspection: Pool Permit# Inspections: Steel Final Grounding Final ��-,-26 -eZ Roofing Permit# F— Inspections: Nailing Sheathing Final Fire Inspection: Failed Inspections: Date Paid: Date Paid: 10. ft CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH,FLORIDA 32233 INSPECTION PHONE LINE 247-5826 Application Number . . . . . 03-00026753 Date 9/11/03 Property Address . . . . . . 335 6TH ST Tenant nbr, name . . . . . . RENOVATE/ADD EXISTING BLD Application description . . . RESIDENTIAL ADD/RENOVATE/ALTER Property zoning . . . . . . . TO BE UPDATED Application valuation . . . . 275000 Owner Contractor ------------------------ EMPIRE DESIGN BUILDERS INC FLOWER, GARY & KIM FISCUS, DEVIN CHAME 335 6TH STREET ATLANTIC BEACH FL 32233 13790 SAND PEBBLE CT (904) 249-7371 JACKSONVILLE FL 322245279 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc - - Plan Check Fee Permit Fee . . . . 1020 . 00 510 . 00 Issue Date . . . . Valuation . . . . 275000 ----------------------------------------------------- ---------------------- Other Fees . . . . . . . . . WATER IMPACT FEE 200 - 00 WATER CROSS CONNECTION 35 . 00 Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 1020 .00 1020 . 00 . 00 . 00 Plan Check Total 510 . 00 510 .00 . 00 . 00 Other Fee Total 235 . 00 235 . 00 . 00 . 00 Grand Total 1765 . 00 1765 . 00 . 00 . 00 BUILDING MATERIAL,RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE,AND MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER- -FAILURE To COMPLY WITH THE CONSTRUCTION LIEN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS-ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW. BUILDING OFFICIAL CITY OF ATLANTIC BEACH BUILDING / ZONING DEPARTMENT L Higgins S. Doerr 800 Seminole Road Atlantic Beach,Florida 32233 -5800 (904)247 (904)247-5845 Fax PLAN REVIEW COMMENTS Permit Application # 0-=S - Z(,,-7S" 7� Property Address: Z3 55 (,elti E=1 REE-1- Applicant: tA-pl P-T-- D t,4 %3 t L--p e A-Z-s Project: 0 L)il"TIE LZ)G This permit application has been: Approved F7 Reviewed and the following items need attention: Please re-submit your application when these items have been completed. Reviewed By: Date: CITY OF ATLANTIC BEACH PERMIT CALCULATION SHEET Date: 9 - 2 . 63 Address -3 )7- �7- SC91 r,(,D-3 eet a D,6 Heated Square Footage @ $ per sq ft = $ Garage Shed @$ per sq ft = $ Carport Porch @ $ per sq ft= $ Deck @ $ per sq ft $ Patio V @ $ per sq il $ TOTAL VALUATION: $ Total Valuation ist $ Remaining Value $ per thousand or portion thereof CONSTRUCTION TYPE: TOTAL BUILDING FEE $ ZONING: AS. 2- + 1/2 Filing Fee $ FLOOD ZONE: t>,- (I) Fireplaces @ $3 5.00 $ IMPERVIOUS SURFACE: ,;L tj C- BUILDING PERMIT FEE $ z-.+v.0 3 *f 2- WATERIMPACTFEE $ ,;koo S (f- 2-0 Lro SEWER IMPACT FEE $ tf WATER METER/TAP $ TOL CAPITAL IMPROVEMENT$ SEWER TAP $ C ( ) RADON HRS .0050 $ SECTION H PAVING ( ) $ CROSS CONNECTION $ ST( ) SURCHARGE $ OTHER $ GRAND TOTAL DUE: 1/13/03 CITY OF ATLANTIC BEACH BUILDING PERMIT APPLICATION (ALTERATIONS/ADDITIONS) Date: 7- 6 — C3 Job Address: 6 S+r e r-ir Avi�I't, (�e C4 C, 7, Owner of Property: Gory P. Elok2er' Address: T35— A-HQ!1+iC_ 5nc,� TelephoneR04- L49 - 73 7 Legal Description: BlockNumber: Lot Number: Y,ICO-18 ZoningDistrict: FXS'Z_ Contractor: FMIQI;r- Qeliepl - &Ide-rs State License Number: CGC e) ro 0 Z_k!J Contractor's Address: 6311 411cemaci G+ Telephone: IQLi- 7 7-9- 9 695�) - Fax: 90q - reci I - VY,6 8 a, 9oq-qqZ 6701 Describe proposed use and work to be done: Re VI17 Uft�%b-A �_ CkJr1l*k-%;d1 Present use of land or building(s): ReSt'4,enr_ C_ Valuation of proposed construction: J Z-76-, 00 0 What are the dimensions of the added space: Z5- -feet x 59 feet Will the added area be heated and cooled? yes New electrical or increase in service? YeS New plumbing fixtures? �/e_� New fireplace? )�c_% New heating/air conditioning?--*e c Is approval of Homeowner's Association or other private entity required?-If yes,please submit with this application. Will this project involve changes in elevation,site grade or any use of fill material or the removal of any trees? 9 NO. Applicant certifies that no change in site grade or fill material will be used on this project. El YES. See Step 2 below. Approval of the Public Works Department is required prior to issuance of a Building Permit. C9 NO. Applicant certifies that no trees will be removed for this project. El YES. Removal of Trees will be required for this project. TREE REMOVAL PERMIT IS REQUIRED. Tree Removal Permits to be reviewed by the Tree Conservation Board,which meets two times each month. Procedure: In order to expedite issuance of permits, please follow all steps and provide all information as appropriate. Incomplete applications may result in delay in issuance of permit. I STEP 1. Verify zoning designation and proper setbacks for the proposed construction. If you are unsure of this information, please contact the Planning and Zoning Department at 904-247-5826. In order to correctly verify zoning designation, please have Property Appraiser's Real Estate Number available. STEP 2. Contact the City of Atlantic Beach Department of Public Works to determine if a pre-construction or post-construction topographical survey or grading plan is required. (If not required, written verification must be provided with this application.) The Department of Public Works is located at: 1200 Sandpiper Lane,Atlantic Beach,FL 32233 Telephone:(904)247-5834 STEP 3. Submit Tree Removal Application if trees are to be removed or relocated. STEP 4. Please submit Building Permit Application, Energy Code Forms, Notice of Commencement, Owner/Contractor Affidavit if owner is contractor,and four(4)complete sets of construction plans to the Building Department,which is located at the Atlantic Beach City Hall,800 Seminole Road,Atlantic Beach,FL 32233 Telephone:(904)247-5826 800 Seminole Road -Atlantic Beach,Florida 32233-5445 Telephone: (904)247-5800 -Fax: (904)247-5845 -http://www.ei.atlantic-beach.fl.us Page I Revised 1/14/03 In addition to construction and engineering detail,plans must contain the following information as appropriate for the type of work being performed. Scale of drawings should be sufficient to depict all required information in a clear and legible manner. 1. Current survey showing the property boundary with bearings and distances and the legal description. 2. Location of all structures,temporary and permanent,including setbacks,building height,number of stories and square footage. Identify any existing structures and uses. 3. If required by the Department of Public Works,a pre-construction topographical survey. 4. Any significant environmental features,including any jurisdictional wetlands,CCCL,natural water bodies. 5. Impervious Surface area calculations:include driveways,sidewalks,patios and other Impervious Surfaces. Swimming pools may be excluded from total Impervious Surface. 6. Other information as may be appropriate for individual applications. I hereby certify that all information provided with this application is correct. Signature of owner: Date: I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of the laws and ordinances governing this type of work will be complied with,whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any federal,state or local rules,regulations,ordinances,or laws in any manner,including the governing of construction or the performance of construction of the property. I understand that the issuance of this permit is contingent upon the above information being true and correct and that the plans and supporting data have been or shall be provided as required. -o, Signature of Contractor: Date: LIF/2�Z05 If Address and contact information of person to receive all correspondence regarding this application(please print). Name: Keu IV) I scu S Mailing Address: Aile., a 0( 600 1- +1 -14 C kSCA4 FL -3z-Ls--r. Telephone: -qoq - 729- qW:5 Fax: 90-1-641 -5'602 E-Mail, kJ1JC,5 4 C0MC,%*6 +-)7e AS TO OWNER: Sworn to and subscribed before me this 4:i�L —dayof Q)J4 ,2003 State of Florida,County of Duval b CHRISTINE ANITA COOK Notary's Signature.(: L.$.b�" &U1k Notary Public,State of Florida R-1,personally known My comm.expires Jan.27,2006 El Produced identification Comm.No.DO 082009 Type of identification produced AS TO CONTRACTOR: Sworn to and subscribed before me this day of 20 State of Florida,County of Duval Notary's Signature: 4,e� UNDA A.SCHAEDEL MY COMMISSION#OD 036580 rsonally known EXPIRES:June 25,2005 Er-Pe D Produced identification Bonded Thru Budget Notary Servifts Type of identification produced 800 Seminole Road -Atlantic Beach,Florida 32233-5445 Telephone: (904)247-5800 -Fax: (904)247-5845 -http://www.ei.atlantic-beach.fl.us Page 2 Revised 1/14/03 08/21/200 3 14:25 9047249154 DURDEN SURVEY PAGE 02/02 MAP SHOWING BOUNDARY SURVEY OF.- LOTS 14, 16 AND 18. BLOCK 8. SUBDIIASION W. ATLANTIC BEACH, AS RECORDED IN PLAT BOOK 5. PACE 69 OF THE CURREN" PUE)I.JC RECORDS OF' DUVAL COUNTY, FLORIDA LOT 19 LOT 17 LOT 13 LOT 13 LOT 11 FOUND 112-sm PRE NO OMMA mum ;/Z-mw FnPE :t NO to0irmATION LLJ LOT 20 ......... ........ . b Of C3 LOT 12 AN R* r F�4 Al ......... ---------------dIA! pwm P""nT NO IDENTIFICA111ON —o c 5006' N.T.S. mum I/Z-mm Pipe FOM 112,WON Fww 112,*pm FqpE NO vENnmcA7?oN —1/ NO 09NT*rA?*N NO MeNrnqrATXN SIXTH STREET 40' RIGHT—OF—WAY LIES IN A.rM ZONE le'SW n.00O Mo ntpvwwL 17, 190. COMUNfrf RINEL ANX QW5 ALL IN"OOM AN&SS ARE MWIX"AS AIZJSLWM ANO poSmm NO supp 1;RESTRocnom LwE By PLAT ALL L07Z i�ZJ HMEON UE WrW AKOOk 0 EXCO-7 AZ�N= CUMFIED TO: X—DOC7rS 4'CION Lt&W F&JM DMID7 AS NOT= GARY P. FLoWER —//—DENOM a'*=PoMe VfC&"AS MOTO 7WRE WAY W AounN& Marmmm,; twr AW NOV,SHOWN ON 7NIS SURVTY T*T 4my pe FWAV mv TW PLqLV MOM OF vvvAL OVA", nAqm4. I hmeby corft Umi Uft mosto the tninbwm t Mod ad ft4h by IM fkwW Board of Land pwwmt to D U R D E N =7 do Ghd AN SUR"NO AND MAPPING. INC. 8150 Lom"t.r Rood JudItsomVIIII0, Morwo 3Z211 , ") -m , I' MjQMoAqEQIrW== (904) 724-S528 Fr.. 721-1s" 09WE1111morlaffs ", . , H WCENVED ouslisim NO. Gage MCC W^Rx.p. -07 SICNED ALJdusi um SCALE: il= 3ol 743 SURVEY NOT VALID UK=THIS PMT 13 !M905=WH'ME w&OF THE AoM SNED. B-3165 Cc: CITY OF ATLANTIC BEACH [). Ford BUILDING / ZONING DEPARTMENT o—eff-T- 800 Seminole Road -ach,Florida 32233 Atlantic Be (904)247-5800 (904)247-5845 Fax PLAN REVIEW COMMENTS Permit Application # C)FS - Z(,-7S- fN Cj ov'ss Property Address: (4�' -rH E=i =QZL Applicant: sotL�pe�a P roj ect: This permit application has been: Ct?�Approved Reviewed and the following items need attention: Please re-subm c en these ite ms have been completed. 0 ,� - (�- 7 Reviewed By. Date: + CITY OF ATLANTIC BEACH BUILDING PERMIT APPLICATION (ALTERATIONS/ADDITIONS) Date: 7– 6 03 Job Address: . S+r e r-Jr C1,1�1�C, V�e C4 C, Owner of Property: Gary Elo �,2',e Address: .335 1;+ Telephone:qO'4- Z_cA 9 - 7 3 7 Legal Description: BlockNumber: Lot Number: 1%IC418 Zoning District: ?\SZ— Contractor: &J,1jQ11;C QeS1!9V2 - C&-\I de Ir-S State License Number: CGC_0607_\!� Contractor's Ad;ess: E7,31T kttc".M"g� C+ '7�[eJC-t0,1,_*Xe_ , EZ 57-7-5-60 J * Telephone: 7 7_JJ - Snb Fax: 90q I - 1-(,o 6 so, lo�j-11L 6709 Describe proposed use and work to be done: Present use of land or building(s): Re S%*Oten C C_ Valuation of proposed construction: J L 76-, 00 0 What are the dimensions of the added space: Z5- -feet x *3 9 feet Will the added area be heated and cooled? New electrical or increase in service? Yes New plumbing fixtures? New fireplace? New heating/air conditioning?--)te s Is approval of Homeowner's Association or other private entity required?—If yes,please submit with this application. Will this project involve changes in elevation,site grade or any use of fill material or the removal of any trees? 9 NO. Applicant certifies that no change in site grade or fill material will be used on this project. YES. See.Step 2 below. Approval of the Public Works Department is required prior to issuance of a Building Permit. NO. Applicant certifies that no trees will be removed for this project. 0 YES. Removal of Trees will be required for this project. TREE REMOVAL PERMI1 IS REQUIRED. Tree Removal Permits to be reviewed by the Tree Conservation Board,which meets two times each month. Procedure: In order to expedite issuance of permits, please follow all steps and provide all i.nformation as appropriate. Incomplete applications may result in delay in issuance of permit. STEP 1. Verify zoning designation and proper setbacks for the proposed construction. If you are unsure of this information, please contact the Planning and Zoning Department at 904-247-5826. In order to correctly verify zoning designation, please have Property Appraiser's Real Estate Number available. STEP 2. Contact the City of Atlantic Beach Department of Public Works to determine if a pre-construction or post-construction topographical survey or grading plan is required. (If not required,written verification must be provided with this application.) The Department of Public Works is located at: 1200 Sandpiper Lane,Atlantic Beach,FL 32233 Telephone:(904)247-5834 STEP 3. Submit Tree Removal Application if trees are to be removed or relocated. STEP 4. Please submit Building Permit Application, Energy Code Forms, Notice of Commencement, Owner/Contractor Affidavit if owner is contractor,and four(4)complete sets of construction plans to the Building Department,which is located at the Atlantic Beach City Hall,800 Seminole Road,Atlantic Beach,FL 32233 Telephone:(904)247-5826 800 Seminole Road -Atlantic Beach,Florida 32233-5445 Telephone: (904)247-5800 -Fax: (904)247-5845 -http://www.ci.atlantic-beach.fl.us Page I Revised 1/14/03 In addition to construction and engineering detail,plans must contain the following information as appropriate for the type of work being performed. Scale of drawings should be sufficient to depict all required information in a clear and legible manner. 1. Current survey showing the property boundary with bearings and distances and the legal description. 2. Location of all structures,temporary and permanent,including setbacks,building height,number of stories and square footage. Identify any existing structures and uses. 3. If required by the Department of Public Works,a pre-construction topographical survey. 4. Any significant environmental features,including any jurisdictional wetlands,CCCL,natural water bodies. 5. Impervious Surface area calculations:'include driveways,sidewalks,patios and other Impervious Surfaces. Swimming pools may be excluded from total Impervious Surface. 6. Other information as may be appropriate for individual applications. I hereby certify that all information provided with this application is correct. Signature of owner: I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of the laws and ordinances governing this type of work will be complied with,whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any federal,state or local rules,regulations,ordinances,or laws in any manner,including the governing of construction or the performance of construction of the property. I understand that the issuance of this permit is contingent upon the above information being true and correct and that the plans and supporting data have been or shall be provided as required. Signature of Contractor: Date: Address and contact information of person to receive all correspondence regarding this application(please print). Name: Keo ;n Fiscus MailingAddress: S31i 4UdLea"Q( Me , FL 37--LS--6 Telephone: . q0q - 72-9- q,00�L—Fax: 90-14,41 —5'668 E-Mail: kC�13 44#5 0_ C4M cot S AS TO OWNER: Sworn to and subscribed before me this 2LJ±L -day of /1..0 cvu-5� 12003 State of Florida,County of Duval Notary's Signature: oc�-Qk CHRISTINE ANITA COOK Notary Public,State of Florida R-1personally known My comm.expires Jan.27,2006 Produced identification Comm.No.DO 082009 Type of identification produced AS TO CONTRACTOR: Sworn to and subscribed before me this day of 20 State of Florida,County of Duval Notary's Signature: LINDA A.SCHAEDEL My COMMISSION#DD 036580 R-lersonally known EXPIRES:June 25,2005 D Produced identification A Bonded Thru Budget Notary services Type of identification produced 800 Seminole Road -Atlantic Beach,Florida 32233-5445 Telephone: (904)247-5800 -Fax: (904)247-5845 -http://www.ci.atiantic-beach.fl.us Page 2 Revised 1/14/03 08/21/2003 14:25 9047249154 DURDEN SURVEY PAGE 02/02 MAP SHOWING BOUNDARY SURVEY OF: LOTS 14. 16 AND 18. BLOCK 8, SUBDIIASION "A". ATLANTIC BEACH, AS RECORDED IN PLAT BOOK 5. PACE 69 OF THE CURREN" PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA LOT 19 LOT 17 LOT 13 LOT 13 LOT I I uh FOUND 112'IRON pn 50.00' �uvm 1/2'mm PIPE NO NO Li > b Of LOT 20 ......... 0 LOT 12 AN 01 l'- Room dmm tkf.......... Al MUMP 112'mom PIPE al NO iDIMMATION - 1, - .!-- �g- 5=00' %F ==gw KT.& FOVAQ I/Z"mm WE 17 lr� IA.I'm 112,ww PIPE NO JUMVIVAUM NO IDOMFIrATION NO ORNYMCAMN SIXTH STREET 40' RIGHT-OF-WAY Nmm Tw Avomrr Lffs AV Fl.rmn ZONE'k,ov FIDW A" ft-VSCV AM 17, 1999. COMMUNRY W)a Na 12=5 AU W"CR AHMES ARE WW'00-AS MWLqtM AM PMC= NO all9.4NNG RES7ft"ON LWE aY FLAr AU L07S SW"HEREON LC WrWN SCOCK a EXCV�r A?J;M"M CMFIED TO: X-OMMS 4'CWN LAW F&J"DrIM AS NOTIM GARY P. FLOWER -//-DENOIn 6' WO nMV eXCM AS NOYED MERE MAY at AmawmL xEsmsuptA twr ARv Nor sHam om mis suRviy imf Amr se Foum ov nc Amc mcom oF ouva Cwhffv� FLORM. I hmre4y ar"Oak MS*t@ tha rnrnbwm teanfed at WM by eft marwo Bwd of Land purmant to D U R D E N m7 g17 SIJRVE)lNG ANO MAPPING. INC. 8150 UnOwtor Rood Jacksonville, norldo 3nil (904) 724-5595 Fox 721-7a45 FLUMA REGIWWW$M%fY0*N�.4797 UCENSED DUUNtUS NO. 08" SICNED AUQUrT Im SCA19: - T*. 3a, THIS SURVEY NOf VALID LDOLM TKS F"NT Is 31WSWO WTti TWrL W,&or TwE AaM W&D. E3-3165 BEACH CITY OF ATLANTIC 800 SEMINOLE ROAD ATLANTIC BEACH, FLORIDA 32233 INSPECTION PHONE LINE 247-5826 Application Number . . . . . 03-00027372 Date 12/10/03 Property Address . . . . . . 335 6TH ST Tenant nbr, name . . . . . . CONSTRUCTION TRAILER Application description . . . DEMO L f Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 Owner Contractor ------------------------ -------------------- ---- FLOWER, GARY MICHAEL G. HOLDER INC 335 6TH STREET 44161 WOODRIDGE DR. ATLANTIC BEACH FL 32233 CALLAHAN FL 32011 (904) 721-7676 ------------------------------------------------------------ ---------------- Permit . . . . . . DEMOLITION PERMIT Additional desc . . Permit Fee . . . . 100 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Fee summary Charged Paid Credited Due ----------------- ---------- ---- ------ ---------- ---- ------ Permit Fee Total 100 . 00 100 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 100 . 00 100 . 00 . 00 . 00 BUILDING MATERIAL,RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE,AND MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER- "FAILURE TO COMPLY WITH THE CONSTRUCTION LIEN LAW CAN RESULT IN THE PROPERTY OWNER PAYTNG TWICE FOR BUILDING IMPROVEMENTS"ISSUED ACCORDING TO APPROVED PLANS WHICFj-ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW. BUILDING OFFICIAL CITY OF ATLANTIC BEACH q-PERMIT APPLICATION Date: Job Address: r4 Owner of Property: i:�-A/L 0 u,3 Address: _50d Telephone: Legal Description: Block Number: Lot Number: Zoning District: 4t� ,e Contractor: -,Z22 ,- //01 J&-A -State License Number: Contractor's Address: 6 00c_/^�6c_ /CZ Fax: Telephone: 7-91 -2 6 76 Describe proposed use and work to be done: Present use of land or building(s): Is approval of Homeowner's Association or other private entity required? If yes, please submit with this application. Will this project involve changes in elevation,site grade or any use of fill material or the removal of any trees? El NO. Applicant certifies that no change in site grade or fill material will be used on this project. YES. See Step 2 below. Approval of the Public Works Department is required prior to issuance of a Building Permit. El NO. Applicant certifies that no trees will be removed for this project. F� YES. Removal of Trees will be required for this project. TREE REMOVAL PERMIT IS REQUIRED. Tree Removal Permits to be reviewed by the Tree Conservation Board,which meets two times each month. Procedure: In order to expedite issuance of permits, please follow all steps and provide all information as approyr Incomplete applications may result in delay in issuance of permit. STEP 1. Attach Tree Removal Application if trees are to be removed or relocated. I hereby certify that a]I information provided with this application is correct. Signature of Owner: Date: I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of the laws and ordinances governing this type of work will be complied with,whether specified herein or not. The granting of a permit does not presurne to give authority to violate or cancel the provisions of any federal,state or local rules,regulations,ordinances,or laws in any manner,including the governing of construction or the performance of construction of the property. I understand that the issuance of this permit is contingent upon the above information being true and correct and that the plans and supporting data have been or shall be provided as required. 800 Seminole Road -Atlantic Beach,Florida 32233-5445 Page 1 Telephone: (904)247-5800 -Fax: (904)247-5845 -http://www.ci.atlantic-beach.fl.us Revised 1/14/03 Signature of Contractor: Date: Address and contact information of person to receive all correspondence regarding this application (please print). Name: Mailing Address: Telephone: Fax: E-Mail: AS TO OWNER: Sworn to and subscribed before me this day of 920 State of Florida,County of Duval Notary's Signature: Personally known Produced identification Type of identification produced AS TO CONTRACTOR: Sworn to and subscribed before me this day of 20_. State of Florida,County of Duval Notary's Signature: F� Personally known M Produced identification Type of identification produced 800 Seminole Road -Atlantic Beach,Florida 32233-5445 Telephone: (904)247-5800 -Fax: (904)247-5845 - http://www.ci.atlantic-beach.fl.us Page 2 Revised 1/14/03 12/04/2003 03:14 9046302957 COURT ADMIN PAGE 01/01 CHAMOCRS Or GARY P. FLOWER COUNTY JUDGE DWVAL COUNTY COURTHOUSE .�ACKSONVILLE, rLORICA 3tZOZ December 4,2003 Mr. Don Ford Atlantic Beach City Inspector se V'a #247-5845 RE: Perrnit 0 26753, 335 6th Street, Atlantic Beach,Florida 32233 Dear Mr.Ford* please this letter Serve as my pemission to change Our building contractor, from Kevin Fiskis to Michael 0. Holder, Inc., as of this date, December2,2003- Please make the changeover in all,necessary paperwork as Soon as possible. Thank you for taking care of this so quickly. If there is ever anything that I can do for you,please do not hesitate to contact my office. ?2 truly yours Gary .Flower GPF/cam HP OfficeJet K Series K80 Log for Personal Printer/Fax/Copier/Scanner Information Systems 247-5845 Dec 04 2003 2:1 Ipm Ust Transaction Date Time T_V—e Identification Duratio Pages Rtauft Dec4 2:10pm Received 9046302957 0:15 1 OK 12/02/2003 06:06 9046302957 COURT ADMIN PAGE 01/01 CHAMBER$ OF GARY P. FLOWER COUNTY JUDGE DUVAL COUNTY COVRTHOU5F- JACKSONVILLE. FLORIDA 3220E December 2,2003 Mr. Don Ford Atlantic Beach CitY InsPedOr s cnt vi-fax#2 4 7-W-- Dear Mr. Ford: please thi- an e U ,* letter serve as iny,permission to ch g our b ilding contractor, from Kevin Fiskis to Michael 0. Holder, Inc., as of this date, December2,2003. Please make the changeover in all-necessary Paperwork as soon as possible. Thank you for taking care of this so quickly. Ifthercis ever anything that I can do for you,please do not hesitate to contact my office. Very yo S 0 ov /Gary Flower Oox- GPF/cam OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FLORIDA 32233-5445 Telephone: (904)247-5800 Fax: (904)247-5845 hftp://ci.atiantic-beach.fl.us FAX To: Fax#: From: Jennifer Date: Pages: Re: 0�001-YT� t��VK- 01)6UnQ c, El Urgent For Review E] Please Reply Notes: 0,Ait, I C(6(f--( S-5 6tn,�J- G-kyL,g HP OfficeJet K Series K80 Log for Personal Printer/Fax/Copier/Scanner Information Systems 247-5845 Dec 03 2003 9:25am Last Transaction Date Time T)= Identificatio Duratio Pnes Resul Dec 3 9:23am Fax Sent 96302957 2:09 2 OK FORM 60OA-2001 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: FLOWERS Builder: EMPIRE_D_­ES__1GN_ Address: Lot: , Sub: Plat: Permitting Office: City, State: FL Permit Number: Owner: Jurisdiction Number: Climate Zone: North I. New construction or existing N vv - 12. Cooling systems 2, Single family or multi-family Single family a. Central Unit 3. Number of units,if multi-family - Cap:48.0 kBtu/hr - SEER: 13.50 4. Number of Bedrooms 5 b. Central Unit 5. Is this a worst case? Yes - Cap:28.4 kBtu/hr SEER: 12.10 6. Conditioned floor area(ft') 3240 ft2 c. N/A 7. Glass area&type Single Pane Double Pane - a. Clear glass,default U-factor 0.0 ft2 609.0 ft2 _ 13. Heating systems b. Default tint 0.0 ft2 0.0 ft2 _ a. Electric Heat Pump Cap:48.0 kBtu/hr c. Labeled U or SHGC 0.0 W 0.0 ft2 HSPF:8.20 8. Floor types _ b. Electric Heat Pump Cap:29.6 kBtu/hr a. Raised Wood,Stem Wall ft2 HSPF:7.60 b. Raised Wood,Post or Pier ft2 c. N/A c. N/A 9. Wall types 14. Hot water systems a, Concrete,Int Insul,Exterior R=5.0,2056.0 ft' a. Electric Resistance Cap:65.0 gallons b.N/A EF:0.91 c. N/A b. N/A d. N/A e. N/A c. Conservation credits 10. Ceiling types (HR-Heat recovery,Solar a. Under Attic R=30.0,2083.0 112 DIP-Dedicated heat pump) b. Single Assembly R=19,0,209.0 112 15. HVAC credits PT, c. Under Attic R=19.0,466.0 ft2 (CF-Ceiling fan,CV-Cross ventilation, 11. Ducts HF-Whole house fan, a. Sup:Unc. Ret:Unc. AH(Sealed):Interior Sup.R=6.0,250.0 ft PT-Programmable Thermostat, b. Sup:Une. Ret:Unc. AH(Sealed):Attic Sup.R=6.0, 125.0 ft MZ-C-Multizone cooling, MZ-H-Multizone heating) F_ Total as-built points: 44683 Glass/Floor Area: 0.19 Total base points: 44895 PASS I hereby certify that the plans and specifications gQverid 1 Review of the plans and �qfjE by this calculation are in complian-m with the a specifications covered by this 01 Energy Code. calculation indicates compliance with the Florida Energy Code. 0 PREPARED BY: Ig M. Dal Before construction is Completed DATE: this building will be inspected for I hereby certify that this building, as designed, is in compliance with Section 553.908 0 compliance with the Florida Energy Code. Florida Statutes. OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: r__ 2-o3 EnergyGauge@(Version: FLRCPB v3.30) FORM 60OA-2001 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: Lot: , Sub: , Plat: FL, PERMIT#: BASE AS-BUILT GLASS TYPES .18 X Conditioned X BSPM Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF Points .18 3240.0 20.04 11687.3 Double,Clear S 15.0 6.0 20.0 35.87 0.44 314.3 Double,Clear S 1.3 5.0 30.0 35.87 0.84 902.0 Double,Clear S 1.3 4.0 9.0 35.87 0.78 250.5 Double,Clear S 1.3 5.0 17.0 35.87 0.84 511.1 Double,Clear SW 1.3 4.0 8.0 40.16 0.80 258.6 Double,Clear W 1.3 5.0 75.0 38.52 0.90 2604.5 Double,Clear W 1.3 6.0 68.0 38,52 0.93 2444.7 Double,Clear W 1.3 5.0 24.0 38.52 0.90 833.4 Double,Clear W 1.3 4.0 11.0 38.52 0.85 359.9 Double,Clear W 1.3 5.0 26.0 38.52 0.90 902.9 Double,Clear NW 1.3 5.0 8.0 25.97 0.92 190.2 Double,Clear N 1.3 5.0 30.0 19.20 0.93 536.3 Double, Clear S 1.3 5.0 18.0 35.87 0.84 541.2 Double,Clear W 1.3 5.0 22.0 38.52 0.90 764.0 Double, Clear N 1.3 5.0 22.0 19.20 0.93 393.3 Double, Clear N 1.3 5.0 20.0 19.20 0.93 357.5 Double,Clear N 1.3 5.0 28.0 19.20 0.93 500.5 Double,Clear E 1.3 5.0 13.0 42.06 0.90 492.6 Double, Clear E 1.3 5,0 60-0 42.06 0.90 2273.4 Double,Clear E 1.3 4.0 24.0 42.06 0.85 856.1 Double,Clear E 1.3 5.0 24.0 42.06 0.90 909.4 Double, Clear E 1.3 6.0 34.0 42.06 0.93 1333.8 Double,Clear E 1.3 5,0 18.0 42.06 0,90 682.0 As-Built Total: 609.0 19212.3 WALL TYPES Area X BSPM Points Type R-Value Area X SPM = Points Adjacent 0.0 0.00 0.0 Contrete, Int Insul, Exterior 5.0 2056.0 1.00 2056.0 Exterior 2056.0 1.70 3495.2 Base Total: 2056.0 3495.2 As-BqIIt Total: 2066.0 2056.0 DOOR TYPES Area X BSPM Points Type Area X SPM Points Adjacent 0.0 0.00 0.0 Exterior Insulated 20.0 4.10 82.0 Exterior 20.0 6.10 122.0 Base Total: 20.0 122.0 1 As-Built Total: 20.0 82.0 EnergyGauge@ DCA Form 60OA-2001 EnergyGaugeV/FlaRES'2001 FLRCPB v3.3O I FORM 60OA-2001 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details [ADDRESS: Lot: , Sub: , Plat: FL, PERMIT#: BASE AS-BUILT CEILING TYPES Area X BSPM Points R-Value Area X SPM X SCM Points Under Attic 2292.0 1.73 3965.2 Under Attic 30,0 2083.0 1.73 X 1.00 3603.6 Single Assembly 19.0 209.0 5.64 X 1.00 1178.8 Under Attic 19.0 466.0 2.34 X 1.00 1090.4 Base Total: 2292.0 3966.2 As-Built Total: 2758.0 5872.8 FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM Points Slab 0.0(p) 0.0 0.0 Raised Wood,Stem Wall 11.0 2190.0 -1.90 -4161.0 Raised 2277.0 -3.99 -9085.2 Raised Wood,Post or Pier 11.0 87.0 1.05 91�8 Base Total: -9085.2 As-Built Total: 2277.0 -4069.2 INFILTRATION Area X BSPM = Points Area X SPM Points 3240.0 10.21 33080.4 3240.0 10.21 33080.4 Summer Base Points: 43264.9 Summer As-Built Points: 56234.3 Total Summer X System Cooling Total X Cap X Duct X System X Credit Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (DM x DSM x AHU) 56234.3 0.628 (1.090xl.147xO.86) 0.253 0.950 9843.2 56234.3 0.372 (1.090xl.147xl.05) 0.282 0.950 CA97.7 43264.9 0.4266 18456.8 1 56234.3 1.00 1.160 0.263 0.950 16295.2 EnergyGauge" DCA Form 60OA-2001 EnergyGaugeO/FiaRES'2001 FLRCPB v3.30 FORM 60OA-2001 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: Lot: , Sub: , Plat: FL, PERMIT#: BASE AS-BUILT GLASS TYPES .18 X Conditioned X BWPM Points Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF Pointl .18 3240.0 12.74 7430.0 Double,Clear S 15.0 6.0 20.0 13.30 3.61 960.0 Double,Clear S 1.3 5.0 30.0 13.30 1.14 454.0 Double, Clear S 1.3 4.0 9.0 13.30 1.26 150.6 Double, Clear S 1.3 5.0 17.0 13.30 1.14 257.3 Double,Clear SW 1.3 4.0 8.0 16.74 1.11 149.0 Double,Clear W 1.3 5.0 75.0 20.73 1.03 1596.2 Double,Clear W 1.3 6.0 68.0 20.73 1.02 1434.9 Double,Clear W 1.3 5.0 24.0 20.73 1.03 510.8 Double,Clear W 1.3 4.0 11.0 20.73 1.04 237.8 Double,Clear W 1.3 5.0 26.0 20.73 1.03 553.4 Double,Clear NW 1.3 5.0 8.0 24.30 1.00 195.1 Double,Clear N 1.3 5.0 30.0 24.58 1.00 739.4 Double,Clear S 1.3 5.0 18.0 13,30 1.14 272.4 Double,Clear W 1.3 5.0 22.0 20.73 1.03 468.2 Double,Clear N 1.3 5.0 22.0 24.58 1.00 542.2 Double,Clear N 1.3 5.0 20.0 24.58 1.00 492.9 Double,Clear N 1.3 5.0 28.0 24.58 1.00 690.1 Double,Clear E 1.3 5.0 13.0 18.79 1.04 254.0 Double,Clear E 1.3 5.0 60.0 18.79 1.04 1172.3 Double, Clear E 1.3 4.0 24.0 18.79 1.06 478.3 Double, Clear E 1.3 5.0 24.0 18.79 1.04 468.9 Double,Clear E 1.3 6.0 34.0 18.79 1.03 657.2 Double,Clear E 1.3 5.0 18.0 18.79 1.04 351.7 As-Built Total: 609.0 13086.7 WALL TYPES Area X BWPM Points Type R-Value Area X WPM Points Adjacent 0.0 0.00 0.0 Concrete, Int Insul,Exterior 5.0 2056.0 5.70 11719.2 Exterior 2056.0 3.70 7607.2 Base Total: 2066.0 7607.2 As-Built Total: 2066.0 11719.2 DOOR TYPES Area X BWPM Points Type Area X WPM Points Adjacent 0.0 0.00 0.0 Exterior Insulated 20.0 8.40 168.0 Exterior 20.0 12.30 246.0 Base Total: 20.0 246,0 As-Built Total: 20.0 168.0 EnergyGauge@ DCA Form 60OA-2001 EnergyGaugeVFlaRES'2001 FLRCPB v3.30 FOiRM 60OA-2001 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: Lot: , Sub: , Plat: , , FL, PERMIT#: BASE AS-BUILT CEILING TYPES Area X BWPM = Points R-Value Area X WPM X WCM Points Under Attic 2292.0 2.05 4698.6 Under Attic 30.0 2083.0 2.05 X 1.00 4270.11 Single Assembly 19.0 209.0 1.86 X 1.00 388.7 Under Attic 19.0 466.0 2.70 X 1.00 1258.2 Base Total: 2292.0 4698.6 As-Built Total: 2758.0 5917.1 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM Points Stab 0.0(p) 0.0 0.0 Raised Wood,Stem Wall 11.0 2190.0 1.20 2628.0 Raised 2277.0 0.96 2185.9 Raised Wood, Post or Pier 11.0 87.0 1.55 134.8 Base Total: 2185.9 As-Built Total: 2277.0 2762.9 1 INFILTRATION Area X BWPM = Points Area X WPM Points 3240.0 -0.59 -1911.6 3240.0 -0.59 -1911.6 Winter Base Points: 20256.1 Winter As-Built Points: 31742.3 Total Winter X System Heating Total X Cap X Duct X System X Credit Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (DM x DSM x AHU) 31742.3 0.619 (1.069xl.169xO.88) 0.416 0.950 9085.9 31742.3 0.381 (1.069xl.169xl.05) 0.449 0.950 6045.3 20256.1 0.6274 12708.7 1 31742.3 1.00 1.171 0.428 0.950 15110.6 EnergyGaugeTm DCA Form 60OA-2001 EnergyGaugeOlFlaRES'2001 FLRCPB v3.30 F6RM 60OA-2001 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: Lot: , Sub: , Plat: , , FL, PERMIT#: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST CTIO COMPONENTS REQUIREMENTS FOR EACH PRACTICE CHECK- Exterior Windows&Doors 1606.1.ABC.1.1 Maximum:.3 cfm/sq.ft..window area; .5 cfm/sq.ftA-00—r wriaa­. Exterior&Adjacent Walls 606.1.ABC.1.2.1 Caulk,gasket,weatherstrip or seal between:windows/doors&frames,surrounding wall; foundation&wall sole or sill plate;joints between exterior wall panels at corners;utility penetrations;between wall panels&top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from,and is sealed to,the foundation to the top plate. Floors 1606.1.ABC.1.2.2 Penetrations/openings>1/8"sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the.perimeter, penetrations and seams. Ceilings 606.1.ABC.1.2.3 Between walls&ceilings; penetrations of ceiling plane of top floor;around shafts, chases, soffits,chimneys,cabinets sealed to continuous air barrier;gaps in gyp board&top plate; attic access.EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter,at penetrations and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations,sealed;or Type IC or non-IC rated, installed inside a sealed box with 1/2"clearance&3"from insulation;or Type IC rated with<2.0 cfm from conditioned space,tested. Multii-_story Hoys es I 606.1.ABC.1.2,5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts--?16.1 ABC.1.3 Exhaust fans vented to outdoors,dampers; combustion space heaters comply with NFPA, have combustion air. 6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all rq��� COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612.1 Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit breaker(electric)or cutoff(gas)must be provided. External or built-in heat required. Swimming Pools&Spas 612.1 Spas&heated pools must have covers(except solar heated).Non-commercial pools must have a pump timer.Gas spa&pool heaters must have a minimum thermal efficiency of.78%. Showerheads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems 610.1 All ducts,fittings,mechanical equipment and plenum chambers shall be mechanically attached,sealed, insulated,and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics:R-6 min. insulation. HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system Insulation 604.1,602.1 Ceilings-Min, R-1 9.Common walls-Frame R-1 1 or CBS R-3 both sides. Common ceiling&floors R-1 1. EnergyGaUgeT' DCA Form 60OA-2001 EnergyGauge(&/F]aRES'2001 FLRCPB v3.30 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* 83.6 The higher the score,the more efficient the home. Lot: , Sub: Plat: FL, I New construction or existing New - 12. Cooling systems 2. Single family or multi-family Single family _ a. Central Unit Cap:48.0 kBtu/hr 3, Number of units,if multi-family I - SEER: 13.50 4. Number of Bedrooms 5 - b. Central Unit Cap:28.4 kBtu/hr 5. Is this a worst case? Yes - SEER: 12.10 6. Conditioned floor area(ft) 3240 ft-2 c. N/A 7. Glass area&type Single Pane Double Pane - a. Clear-single pane 0.0 ft2 609.0 ft2 - 13. Heating systems b. Clear-double pane 0.0 ft2 0.0 W - a. Electric Heat Pump Cap:48.0 kBtu/hr c, Tint/other SHGC-single pane 0.0 ft2 0.0 ft2 _ HSPF:8.20 d. Tint/other SHGC-double pane b. Electric Heat Pump Cap:29.6 kBtu/hr 8. Floor types - HSPF:7.60 a. Raised Wood,Stem Wall R=I 1.0,2 190.0ft2 c. N/A b. Raised Wood,Post or Pier R=I 1.0,87.0ft2 c. N/A 14. Hot water systems 9. Wall types a. Electric Resistance Cap:65.0 gallons a. Concrete,Int Insul,Exterior R=5.0,2056.0 ft2 EF:0.91 b.N/A b.N/A c. N/A d. N/A c. Conservation credits e. N/A (HR-Heat recovery,Solar 10. Ceiling types DHP-Dedicated heat pump) a. Under Attic R=30.0 2083.0 ft2 15. HVAC credits PT, b. Single Assembly R=19.�,209.0 ft- (CF-Ceiling fan,CV-Cross ventilation, c. Under Attic R=19.0,466.0 ft' HF-Whole house fan, 11. Ducts PT-Programmable Thermostat, a. Sup:Unc. Ret:Unc. AH(Scaled):Interior Sup.R=6.0,250.0 ft MZ-C-Multizone cooling, b. Sup:Unc. Rct:Unc. AH(Sealed):Attic Sup.R=6.0, 125.0 ft NIZ-H-Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above energy saving features which will be installed(or exceeded) JHE ST4 in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: Address of New Home: City/FL Zip: 0 *NOTE: The home's estimated energy performance score is only available through the FLAIRES computer program. This is-not a Building Energy Rating. Ifyour score is 80 or greater (or 86for a US EPAIDOE EnergyStar""designation), your home may qualifyfor energy efficiency mortgage(EEM) incentives ifyou obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 3211638-1492 or see the Energy Gauge web site at wwwfisec.ucf edufor information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 850148 7-1824. EnergyGaugeg(Version:FLRCPB v3.30) Residential System Sizing Calculation Summary Project Title: Code Only FLOWERS Professional Version FL Climate: North 8/22/m Location for weather data: Jacksonville - Defaults: Latitude(30) Temp Range(M) Humiditydata: InteriorRH (50%) Outdoor wet bulb(7 F) Humidity difference(49qr.) Winter design temperature 32 F Summer design temperature 94 F Winter setpoint 70 F Summer setpoint 75 F Winter temperature difference 38 F Summer temperature difference 19 F Total heating load calculation 46807 Btuh Total cooling load calculation 65652 Btuh Submitted heating capacity % of calc Btuh Submitted cooling capacity % of calc Btuh Total (Electric Heat Pump) 165.8 77600 Sensible (SHR = 0.5) 73.6 38200 Heat Pump+Auxiliary(O.OkW) 165.8 77600 Latent 277.8 38200 Total (Electric Heat Pump) 116.4 76400 WINTER CALCULATIONS Winter Heating Load (for 3240 sqft) Load component Load Ducts(5%) Window total 609 sqft 16748 Btuh Wall total 2056 sqft 11308 Btu h ows(3M) Door total 20 sqft 357 Btuh Doors(l%) Ceiling total 2758 sqft 4037 Btuh Floor total See detail report 3082 Btuh Infiltration 216 cfm 9047 Btuh Subtotal 44678 Btuh Duct loss 2229 Btuh Walls(24%) TOTAL HEAT LOSS 46807 Btuh SUMMER CALCULATIONS Summer Cooling Load (for 3240 sqft) Load component Load Window total . 609 sqft 30340 Btu h Lterd Wall total 2056 sqft 4441 Btuh Door total 20 sqft 212 Btuh Lat—t WN.(i 0%) Ceiling total 2758 sqft 4542 Btuh Floor total 90 BTu h Wndo�(46%) Infiltration 189 cfm 3958 Btuh Internal gain 3600 Btuh Ducts(7%) Subtotai(sensible) 47184 Btuh Duct gain 4718 Btuh Total sensible gain 51902 Btuh CeOngs(7%) Latent gain(infiltration) 6310 Btu h EnergyGauge(&System Sizing based on ACCA Manual J. Latent gain(internal) 7440 Btuh PREPARED BY: Total latent gain 13750 Btuh DATE: TOTAL HEAT GAIN 65652 Btuh EnergyGauge(I FLRCPB v3.30 System Sizing Calculations - Winter Residential Load - Component Details Project Title: Code Only FLOWERS Professional Version FL Climate: North Reference City: Jacksonville (Defaults) Winter Temperature Difference: 38.0 F 8/22/03 Window Panes/SHGC/Frame/U Orientation Area X HTM= Load 1 2, Clear, Metal, DEF N 20.0 27.5 550 Btuh 2 2, Clear, Metal, DEF N 30.0 27.5 825 Btuh 3 2, Clear, Metal, DEF N 9.0 27.5 248 Btuh 4 2, Clear, Metal, DEF N 17.0 27.5 468 Btuh 5 2, Clear, Metal, DEF NE 8.0 27�5 220 Btuh 6 2, Clear, Metal, DEF E 75.0 27.5 2062 Btuh 7 2, Clear, Metal, DEF E 68.0 27.5 1870 Btuh 8 2, Clear, Metal, DEF E 24.0 27.5 660 Btuh 9 2, Clear, Metal, DEF E 11.0 27.5 302 Btuh 10 2, Clear, Metal, DEF E 26.0 27.5 715 Btuh 11 2, Clear, Metal, DEF SE 8.0 27.5 220 Btuh 12 2, Clear, Metal, DEF S 30.0 27.5 825 Btuh 13 2, Clear, Metal, DEF N 18.0 27.5 495 Btuh 14 2, Clear, Metal, DEF E 22.0 27.5 605 Btuh 15 2, Clear, Metal, DEF S 22.0 27.5 605 Btuh 16 2, Clear, Metal, DEF S 20.0 27.5 550 Btuh 17 2, Clear, Metal, DEF S 2&0 27.5 770 Btuh 18 2, Clear, Metal, DEF W 13.0 27.5 358 Btuh 19 2, Clear, Metal, DEF W 60.0 27.5 1650 Btuh 20 2, Clear, Metal, DEF W 24.0 27.5 660 Btuh 21 2, Clear, Metal, DEF W 24.0 27.5 660 Btuh 22 2, Clear, Metal, DEF W 34.0 27.5 935 Btuh 23 2, Clear, Metal, DEF W 18.0 27.5 495 Btuh Window Total 609 16748 Btuh Walls Type R-Value Area X HTM= Load 1 Concrete- Exterior 5.0 2056 5.5 11308 Btuh Wall Total 2056 11308 Btuh Doors Type Area X HTM= Load 1 Insulated - Exter 20 17.9 357 Btuh Door Total 20 35713tuh Ceilings Type R-Value Area X HTM= Load 1 Under Attic 3.0.0 2083 1.3 2708 Btuh 2 Single Assembly 19-Q 209 1.9 397 Btuh 3 Under Attic 19.0 466 2.0 932 Btuh Ceilina Total 2758 403713tuh Floors Type R-Value Size X HTM= Load 1 Raised Wood/Enclosed 11 2190.0 sqft 1.3 2847 Btuh 2 Raised Wood/Open 11 87.0 sqft 2.7 235 Btuh Floor Total 2277 3082 Btuh Infiltration Type ACH X Building Volume CFM= Load Natural 0.40 32400(sqft) 216 9047 Btuh Mechanical 0 0 Btuh Infiltration Total EnergyGaugeS FLRCPB v3.30 216 9047 Btuh Manual J Winter Calculations Residential Load - Component Details (continued) Project Title: Code Only FLOWERS Professional Version FL Climate: North 8/22/03 Subtotal 44578 Btuh Totals for Heating Duct Loss(using duct multiplier of 0.05) 2229 Btuh Total Btuh Loss 46807 Btuh Key:Window types(SHGC-Shading coefficient of glass as SHGC numerical value or as clear or tint) (Frame types-metal,wood or insulated metal) (U-Window U-Factor or'DEF'for default) (HTM-ManualJ Heat Transfer Multiplier) Key:Floor size(perimeter(p)for slab-on-grade or area for all other floor types EnergyGauge@ FLRCPB v3.30 System Sizing Calculations - Summer Residential Load - Component Details Project Title: Code Only FL FLOWERS Professional Version Climate: North Reference City: Jacksonville (Defaults) Summer Temperature Difference: 19.0 F 8/22/03 Type Overhang Window Area(sqft) HTM Load Window Panes/SHGC/U/lnSh/ExSh Ornt Len Hot Gross Shaded Unshaded Shaded Unshaded 1 2,Clear, DEF, N, N N 15 6 20.0 0.0 20.0 23 23 460 Btuh 2 2,Clear, DEF, N, N N 1.33 5 30.0 0.0 30.0 23 23 690 Btuh 3 2, Clear, DEF, N, N N 1.33 4 9.0 0.0 9.0 23 23 207 Btuh 4 2,Clear, DEF, N, N N 1.33 5 17.0 0.0 17.0 23 23 391 Btuh 5 2,Clear, DEF, N, N NE 1.33 4 8.0 0.0 8,0 23 51 408 Btuh 6 2, Clear, DEF, N, N E 1.33 5 75.0 16.6 58.4 23 72 4587 Btuh 7 2, Clear, DEF, K N E 1.33 6 68.0 12.5 55.5 23 72 4281 Btuh 8 2,Clear, DEF, N, N E 1.33 5 24.0 4.9 19.1 23 72 1487 Btuh 9 2,Clear,DEF, N,N E 1.33 4 11.0 1.4 9.6 23 72 723 Btuh 10 2,Clear, DEF, N,N E 1.33 5 26.0 5.8 20.2 23 72 1590 Btuh 11 2,Clear, DEF, N, N SE 1.33 5 8.0 0.0 8.0 23 63 504 Btuh 12 2, Clear, DEF, N, N S 1.33 5 30.0 30.0 0.0 23 37 690 Btuh 13 2,Clear, DEF, N,N N 1.33 5 18.0 0.0 18.0 23 23 414 Btuh 14 2,Clear, DEF, N, N E 1.33 5 22.0 3.7 18.3 23 72 1401 Btuh 15 2,Clear, DEF, N, N S 1.33 5 22.0 22.0 0.0 23 37 506 Btuh 16 2,Clear, DEF,N, N S 1.33 5 20.0 20.0 0.0 23 37 460 Btuh 17 2, Clear, DEF,N, N S 1.33 5 28.0 28.0 0.0 23 37 644 Btuh 18 2,Clear, DEF, N, N W 1.33 5 13.0 0.0 13.0 23 72 936 Btuh 19 2,Clear, DEF, N, N W 1.33 5 60.0 13.3 46.7 23 72 3669 Btuh 20 2,Clear, DEF,N, N W 1.33 4 24.0 6.6 17.4 23 72 1403 Btuh 21 2,Clear, DEF, N, N W 1.33 5 24.0 4.9 19.1 23 72 1487 Btuh 22 2,Clear, DEF, N, N W 1.33 6 34.0 5.5 28.5 23 72 2180 Btuh 23 2,Clear, DEF, N, N W 1.33 5 18.0 1.5 16.5 23 72 1223 Btuh Window Total -- 1 609 30340 Btuh Walls Type R-Value Area HTM Load 1 Concrete-Exterior 5.0 2056.0 2.2 4441 Btuh Wall Total 2056.0 4441 Btuh Door-s Type Area HTM Load Insulated-Exter 20.0 10.6 212 Btuh Door Total 20.0 212 Btuh Ceilings Type/Color R-Value, Area HTM Load 1 Under Attic/Dark 30.0 2083.0 1.5 3041 Btuh 2 Single Assembly/Dark 19.0 209.0 2.1 447 Btuh 3 Under Attic/Dark 19.0 466.0 2.3 1053 Btuh Ceilinq Total 2758.0 4542 Btuh Floors Type R-Value Size HTM Load 1 Raised Wood 11.0 2190.0 sqft 0.0 0 Btuh 2 Raised Wood 11.0 87.0 sqft 1.0 90.48 Btuh Floor Total 2277.0 90 Btuh EnergyGaugeB FLRCPB V3.30 Manual J Summer Calculations Residential Load - Component Details (continued) Project Title: Code Only FLOWERS Professional Version FL Climate: North 8/22/03 Infiltration Type ACH Volume CFM= Load Natural 0.35 32400 189.4 3958 Btuh Mechanical 0 0 Btuh Infiltration Total 189 3958 Btuh Internal Occupants Btuh/occupant Appliance Load gain 8 X 300 + 1200 360 Subtotal 47184 Btuh Duct gain(using duct multiplier of 0.10) 4718 Btuh Total sensible gain 51902 Btuh Totals for Cooling Latent infiltration gain (for 49 gr. humidity difference) 6310 Btuh Latent occupant gain (8 people @ 230 Btuh per person) 1840 Btuh Latent other gain 5600 Btuh TOTAL GAIN 66652 Btuh I Key: Window types(SHGC-Shading coefficient of glass as SHGC numerical value or as clear or tint) (U-Window U-Factor or'DEFfor default) (InSh-Interior shading device:none(N),Blinds/Daperies(B)or Roller Shades(R)) (ExSh-Exterior shading device: none(N)or numerical value) (Ornt-compass orientation) EnergyGauge@ FLRCPB v3.30 67 -f5 Z-7 69 0 4 2 6 Ok HULSBERG ENGINEERING PAGE 02 05/05/2004 14:43 FILE COPY] 1" AIR SPACE (TYPICAL) NEW BRICK VENEE EXISTING CLAY MASONRY UNIT WALL NEW CORRUGATED BRICK EXISTING SLAB TIES AT 16"oc. VERTICALLY AND 32"oc. HORIZONTALLY. ATTACH TIES TO MASONRY WALL WITH 3/ir,"x IY4" TAPCON SCREWS. INSTALL WEEPHOLES BELOW`—,lAI SLAB LEVEL AT 48"oc. I R v POUR NEW FOOTING WITH /—EXISTING FOOTING AND REINFORCEMENT (1) #5 CONT. DOWEL NEW IL 'Op v FOOTING TO EXISTING AT 48"oc WITH #5 DOWELS 'APPROVEO LS We CITY� OF ATLANTIC BEACH EPDXY NEW DOWE BUILDING OFF'r-E INTO EXISTING FOOTING Ay 0 -5 2003 DETAIL OFADDING NEW FOOTING EXTENSION TO EXISTING FOOTING FOR BRICK VENEER K, Hut J%FIC.4 ,4 .4 Q EXTENSION OF FOOn?fG FOR BRICK FILE COPY No.331.5 FLOWERS HULSHING G (FL 2W NMW M,SUFTE 2M JACKSMUE,SL 3M7 Ph.(W4)US-2401 Fax(904)2804X7 0 JM"K NUUMR64 PE E]FL= Wwat PE Cf-At C ocs c cr-r%&�� 11 t.331 NMI n 444 it rucewrn sy, wu HP Fax Series 900 Fax History Report for Plain Paper Fax/Copier May 05 2004 3:50pm Last Fax Date Time Identification Duration PA= Result May 5 3:48pm Received 9042604367 0:38 2 OK Result: OK - black and white fax 05/05/2004 14:43 9042604367 HULSBERG ENGINEERING PAGE 01 91 CITY C)F �'-JD MAY 0 5 2004 DATE &TIME: May 5, 2004 3:29:54 PM TO. Don Ford COMPANY; City Of Atlantic Beach Building Dept sy: FAX NO; 247-5877 FROM: Jeffrey K- Hulsberg COMPANY: Hulsberg Engineering, Inc. FAX NO: (904) 260-4367 PHONE NO: (904) 886-2401 R E.- NO. OF PAGES: 2, including cover CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FLORIDA 32233 ........... rl qv INSPECTION PHONE LINE 247-5826 Application Number . . . . . 03 -00026753 Date 12/17/03 Property Address . . . . . . 335 6TH ST Tenant nbr, name . . . . . . RENOVATE/ADD EXISTING BLD Application description . . . RESIDENTIAL ADD/RENOVATE/ALTER Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 275000 Owner Contractor -- ---- - ---- ---- - ----- --- - - -- - - - -- --- - - --- ------- FLOWER, GARY & KIM MICHAEL G. HOLDER INC 335 6TH STREET 44161 WOODRIDGE DR. ATLANTIC BEACH FL 32233 CALLAHAN FL (904) 249-7371 CALLAHAN FL 32011 (904) 721-7676 ------- -- ---- -- -- -- ----- -- --- ----- --- - -- - - - - -- - - --- -- ----- - - -- - ---- ----- - --- Permit . . . . . . ELECTRICAL PERMIT Additional desc SVC INCREASE TO 200AMP Sub Contractor DYNAMIC ELECTRIC COMPANY Permit Fee . . . . 85 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date 6/17/04 Fee summary Charged Paid Credited Due ---------- ------- - --------- - ---- --- - - ---- - ----- - - ------- - Permit Fee Total 85 . 00 85 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 85 . 00 85 . 00 . 00 . 00 BUILDING MATERIAL,RUBBISH AND DEBRIS FROM TI-HS WORK MUST NOT BE PLACED IN PUBLIC SPACE,AND MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER. "FAILURE TO COMPLY WITH THE CONSTRUCTION LIEN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS"ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW. BUILDING OFFICIAL CITY OF ATLANTIC BEACH ELECTRICAL PERMIT APPLICATION Date: JZ 1(" 1'0 Property Address: f !2 v?sz Owner: Mf t4v L J E7-x, Telephone#: Contractor: elfc-MI'C' — Telephone#: Contractor Address: ;-72- 0 54N J_JS6 Fax#: -2.6o — 75-77 In consideration of permit given for doing the work as described in the above statement, we hereby agree to perform said work in accordance with the attached plans and specifications which are a part hereof and in accordance with the City of Atlantic Beach ordinance and standards of good practice listed therein. Building: Building Type: 0 Trailer Service: If other construction is 0 New Ll Residence Q Temp. Cl New being done on this building Or site,list the building )d Old 0 Commercial 13 Signs Increase Permit number: Re-wire 0 Addition Sq.Ft. U Repair too to Z4-7s,3 Conductor Size: AMPS: COPPER E] ALLNUNUM Pk Switch or RACE Breaker AMPS ZOO PH W VOLT WAY Existing Service RACE Size AMPS 16 0 PH W (4 VOLT 7-4 0 WAY Feeders: NO. SIZE NO SIZE NO SIZE Lighting Outlets CONCEALED OPEN Receptacles CONCEALED OPEN 0 10 AMPS 31 100 AMPIS Switches R-0 Incandescent 3.0 Fluorescent & M.V. Fixed 0.100 AMPS OVER BELL Appliances CD TRANSFER. Air H.P.RATING H.P.RATING CEILING KW-HEAT Conditioning COMP.MOTOR OTHER MOTORS AMPS HEAT eT 614 7d 1-1 Motors 0-1 H.P. IVOLTAGE NO. OVER I H.P. PHS I _EH_� I UNDER600V OVER600V Transformers NO. KVA NO. KVA No.Neon-Transf Ea._Sign Miscellaneous 800 Seminole Road -Atlantic Beach,Florida 32233-5445 Phone: (904)247-5800- Fax: (904)247-5845- http://www.ci.atlantic,-beach.H.us 1" AIR SPACE (TYPICAL) NEW BRICK VENEER--,,,----,, EXISTING CLAY MASONRY UNIT WALL NEW CORRUGATED BRICK ISTING SLAB TIES AT 16"oc. VERTICALLY AND 32"oc. HORIZONTALLY., ATTACH TIES TO MASONRY RA WALL WITH 3/16"x IY4" TAPCON SCREWS. INSTALL WEEPHOLES BELOW SLAB LEVEL AT 48"Oc. — 6 EXISTING FOOTING MIN. AND REINFORCEMENT v M6 N POUR NEW FOOTING WITH--.,,, (1)#5 CONT. DOWEL NEW FOOTING TO EXISTING AT 48"oc WITH#5 DOWELS co EPDXY NEW DOWELS 4" INTO EXISTING FOOTING DETA&OF ADDiNG NEW FOOTING EXTENSION TO EXISTING F0077NG FOR BRICK VENEER C33 EXTENSION-OF F007ING FOR BRICK FLOWERS NnG ENGDOMM0. DiC. (FL.CERT.No.26846) 2955 HARTLEY RD.,SUITE 202 JACKSOWILLE,R-32257 Ph.(904)SW2401 Fox(904)260-43sT t CON JEFFREY K HULSERG,PE [D FLOYD S.Suls(K PE Nr FEJ 331521 Ti PE#.7 WMI SCALE*V -I CHECKED BY-&M CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FLORIDA 3223-31 "A INSPECTION PHONE LINE 247-5826 Application Number . . . . . 03-00026753 Date 3/05/04 Property Address . . . . . . 335 6TH ST Tenant nbr, name . . . . . . RENOVATE/ADD EXISTING BLD Application description . . . RESIDENTIAL ADD/RENOVATE/ALTER Property' Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 275000 Owner Contractor - -- - ------ ---- -- -------- --- --- ------------ ------ FLOWER, GARY & KIM MICHAEL G. HOLDER INC 335 6TH STREET 44161 WOODRIDGE DR. ATLANTIC BEACH FL 32233 CALLAHAN FL (904) 249-7371 CALLAHAN FL 32011 (904) 721-7676 ----- --------- ----------- ------------------- - - ---------------- -------------- Permit . . . . . . PLUMBING PERMIT Additional desc . . Sub Contractor . . WORKMANS KWIK FIX PLUMBING Permit Fee . . . 168 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Fee summary Charged Paid Credited Due -- -------------- - ---------- ------- -- - ---------- ---------- Permit Fee Total 168 . 00 168 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 168 . 00 168 . 00 . 00 . 00 BUILDING MATERIAL,RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE,AND MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER. "FAILURE TO COMPLY WITH THE CONSTRUCTION LIEN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS" ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW. BUILDING OFFICIAL e CITY OF ATLANTIC BEACH r V I �" PLUMBING PERMIT APPLICATION Property Address:_335"' Ce,�� -k- Date: Owner: Telephone#: Contractor: �Pll Telephone #: 31& 4H Contractor A ddress: --- Fax#: gq � 016) ? In consideration of permit given for doing the work as described in the above statement,we hereby agree to perform said work in accordance with the attached plans and specifications which are a part hereof and in accordance with the City of Atlantic Beach ordinance and standards of good practice listed therein. Installation of plumbing and fixtures must be in accordance with the most recent edition of the Southern Standard Plumbing Code. Plumbing Type: If other construction is being done on this building or site, ef'-1"^New list the building permit number: Re-Pipe Z)3 0 0 0 9 V1 Number of Fixtures: Bath Tubs Showers Closets Shower Pans Dishwashers Sinks Disposals Urinals Floor Drains Washing Machine Lavatory Water Sewer Water Heaters Other Fees Permit Issuing Fee: $35.00 Total Fixtures: X $7.00 + $35.00 800 Seminole Road - Atlantic Beach, Florida 32233-5445 Phone: (904) 247-5800- Fax: (904) 247-5845- http:/twww.ci.atlantic-beach.fl.us CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FLORIDA 32233 INSPECTION PHONE LINE 247-5826 Application Number . . . . . 04-00028168 Date 4/29/04 Property Address . . . . . . 335 6TH ST Tenant nbr, name . . . . . . RE-ROOF Application description . . . ROOF Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 3500 Owner Contractor ------------------------ ------------------------ FLOWER, GARY R.D. WOODS ROOFING 335 6TH STREET 85440 ALENE ROAD ATLANTIC BEACH FL 32233 YULEE FL 32097 (904) 225-2480 ------------------- --------------- -------- ---------------------------------- Permit . . . . . . ROOF PERMIT Additional desc . . Permit Fee . . . . 75 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 3500 Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 75 . 00 75 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 75 . 00 75 . 00 . 00 . 00 BUILDING MATERIAL,RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE,AND MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER. "FAILURE TO COMPLY WITH THE CONSTRUCTION LIEN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS"ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUBfECT TO REVOCATION FOR VIOLATION OF APPLICA13LE PROVISIONS OF LAW. B DING OFFICIAL CITY OF ATLANTIC BEACH PERMIT CALCULATION SHEET Date Address F��rPermit fee based on dollar evaluation as indicated on permit application. Heated Square Footage s persqft= $ Garage/Shed s per sq ft= $ Carport/Porch s per sq ft= $ Deck $ per sq ft= $ Patio s per sq ft= $ TOTAL VALUATION: $ 3!�b $35.00 is, S1000.00 $ $35.00 Total Valuation s $ Remaining Value Per thousand or portion thereof- CONSTRUCTION TYPE: TOTAL BUILDING FEE ZONING: + V2Filing Fee $ FLOOD ZONE: ( ) Fireplaces * $35.00 $ IMPERVIOUS SURFACE: BUILDING PERMIT FEE $ WATER IMPACT FEE $ SEWER IMPACT FEE $ WATER METER/TAP $ CAPITAL IMPROVEMENT S SEWER TAP $ C ( )RADON HRS.0050 $ SECTION H PAVING $ CROSS CONNECTION $ ST ( ) SURCHARGE $ OTHER $ GRAND TOTAL DUE $ CC- CITY OF ATLANTIC BEACH D*. Ford BUILDING / ZONING DEPARTMENT go— i 800 Seminole Road err Atlantic Beach,Florida 32233 (904)247-5800 (904)247-5845 Fax PLAN REVIEW COMMENTS Permit Application c4- zsi Property Address: -�3 L Applicant: Project: Rc- PC30P This permit application has been: E&'*--Approved F7 Reviewed and the following items need attention: Please re-submit your application when these items have been completed. Reviewed By: �iL Date: CITY OF ATLANTIC BEACH ROOFING PERMIT APPLICATION Date: Job Address: Owner of Property: C-j*1?_,Y + Cto,%_ rt_�d-X_ Address: Telephone: Contractor: 44A'fkt1 4W.10��j -State License Number: Contractor's Address: T.__ A/",V, 3;zpy Telephone: 2:�Y--- 4. 1�_-- 2 Fax: /Q90 $e_ CP Scope of Work: ozc--,,6 V C G4 W S AS alarno;-) L&tF Deck Slope: z. Greater than 2:12 Less than 2:12 Valuation of work: Product Name(Example: Timberline): Manufacturer(Example: GAF): 6rAf ASTM Designation(s): /"7p,;*7 -7 �Z Required Inspections: Sheathing and Final Signature of Owner: Date: j6 , Date: Signature of Contractor: AS TO OWNER: Sworn to and subscribed before me this day of �20 State of Florida,County of Duval Notary's Signature: RMRITALODGE N0ftyPW*-Sftftofft1da El Personally known myCany6ionBj0p�mWN"W2rL6 V Produced identification commbdon#CC972675 Type of identification producedF�L4t- Fy/_0�513 o�b W W W W —— —; 9-q AS'T6 CONTRACTOR: Sworn to and subscribed before me this ;2 day of ' 20 State of Florida,County of Duval Notary's Signa )uanita C.Knox MYCOMMISSIONOI CC964097 EXPIRES ly El Personally k own October 27, 2004 1 i BONDED THRU TROY FAIN INSURANCE,INC Produced i enti ation I ti Type of i en i Oication produced F" 5 z-0 800 Seminole Road Atlantic Beach,Florida 32233-5445 Telephone: (904)247-5800 Fax: (904)247-5845 -http://www.ci.atiantic-beach.fl.us Page 1 Revised 2/21/03 Boc)k 11776 Page 465 I�114`V�Jz ­ I z , . NOTICE OF COMMENCEMENT State of Tax Folio No. County of To Whom It May Concern: The undersigned hereby informs you that improvements will be made to certain real property, and in accordance with Section 713 of the Florida Statutes,the following information is stated in this NOTICE OF COMMENCEMENT. Legal Description of property being improved: Address of property being improved: General description of improvements: Owner: Address: X' Owner's interest in site of the improvement: ,-'Vee Simpji>Fitleholder(if other than owner): Name: DAPI PAC%-I !3!;FS50 Catntractor: 0/ Page 465­ Address: Filed & Recorded Telephone No.: �dr C/A- Fax No: 07 51,� 9151K JIM FULLER CIRCUIT COURT Surety(if any) DUVAL CUTY RECORDING S 5.00 Address: Amount of Bond$ TRUST FUND $ 1.00 Telephone No: Fax No: Name and address of any person making a loan for the construction of the improvements Name: Address: Phone No: Fax No: Name of person within the State of Florida, other than himself, designated by owner upon whom notices or other documents may be served: Name: Address: Telephone No: Fax No: In addition to himself, owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.06(2)(b),Florida Statues. (Fill in at Owner's option) Name: Address: Telephone No: Fax No: Expiration date of Notice of Commencement(the expiration date is one (1)year from the date of recording unless a different date is specified): THIS SPACE FOR RECORDER'S USE ONLY OWNER Signed Date: Before me this c�,)t�5� day of in the coty of buval,State Of Florida,has personally appeared 'Z!�� rjlju)ef— X. otary Public at Large,State of Florida,County of Duval. SANDRAB.GURNE My commission expires: My COMMISSION#DD 293508 ...-V EXPIRES-March 6,2008 or Personally Known: o BMW Thni Nftry PL"Ic Urdqrwr#0m Produced Identification:a- A Fi;w-.5/.161 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FLORIDA 32233 INSPECTION PHONE LINE 247-5826 Application Number . . . . . 05-00030847 Date 7/27/05 Property Address . . . . . . 335 6TH ST Tenant nbr, name . . . . . . REPL HVAC Application description . . . MECHANICAL ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 Owner Contractor ---------- -------------- ------------------------ FLOWER, GARY NICK' S SOLAR & AIR SYSTEMS 335 6THSTREET 4891 TIMIQUANA RD ATLANTIC BEACH FL 32233 JACKSONVILLE FL 32210 (904) 737-5499 --- ----- -------------------------------------------------------------------- Permit MECHANICAL PERMIT Additional desc . . Permit Fee . . . . 79 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Fee summary Charged Paid Credited Due ---- ------------- ---------- ---------- ---------- ---------- Permit Fee Total 79 . 00 79 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 79 . 00 79 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. BUILDING OFFICIAL CITY OF ATLANTIC BEACH MECHANICAL PERMIT APPLICATION Date: t� 0 Property Addriess: Owner. Telephone Contractor: J La4_t__� Telephone#:_222L�` Contractor Address: Fax Contractor Signature: ............ Ilk 15 in the above statement, we hereby agree to perform s In consideration of permit give with the attached plans and specifications which are a part hereof and in accordance with the,City of Atlantic Beach ordinances and sta d ds of ood ractice listed therein. n ar Type of Heating Fuel: If other construction is being done ci�this—building Q Electric or site,list the building permit number: EJ Gas: _LP —Natural —Central Utility Cl oil Q , Other—Specify iP MECHANICAL EQUIPMENT TO BE INSTALLED NATURE OF WORK C) Heat Space _Recessed Central Floor Residential Air Conditioning: —Room Central 0 Duct System: Material-----7-Thickness— 13 Commercial a Refrigeration Maximum capac'tY_cfin Q New Building 0 Cooling Tower:Capacity _M 0 Fire Sprinklers:Number of Heads Q Existing Building El Elevator: __ Manlift Es—calator 13 Gasoline Pumps (Number) C3 Replacement of Existing System Q Tanks —(Number) :;-��....(Number) Q New Installation 13 LPG Containers —(Number) (No system previously installed) • Unfired Pressure Ve�ssel • Boilers U Extension or Add-on to Existing System • Gas Piping 13 Other-Speci C3 Other—Specify fy__� LIST ALL EQUIPMENT AIR CONDITIONING,REFRIGERATION EQUIPMENT&CONDENSOR'S Approving Number Units Description Model# Manufacturer Ton's Agency Se or r7' HEATING—FURNACES,BOILERS,FIREPLACES&AIR HANDLER'S Approving Number Units Description Model# Manufacturer BTU's Agency TAN S No ninal C )acity Type Li juid Serial Approving How Many &Dimensions Contained Manufacturer No. Agency 800 Seminole Road *Atlantic Beach,Florida 32233-5445 Phone: (904)247-5800* Fax: (904)247-5845 e http://wWW.ci-atiantic-beach.fl.us Revised 1/04 *'!'&ET1OgER1a;EtCiECIpBeach T *** r 110"ORE' Type;POC Drawer: 1 Da'tee. 5/26/@4 01 Rece t no: 59104 Descr* bon �116131 267g5u3antity Amount BP BUILDING PERMITS 1.00 $35.00 Tender d CK CHECelail 11127 $35.00 Total tendered Total payment $35.00 $35.00 Trans date: 5/26/04 Time: 11:05:48 6 2004 CK# LAN ORI -NOTICE J OF Umik, JOB ADDRESS DATE 1 :33S s-,-. ��-Izl THIS JOB HAS NOT BEEN COMPLETED The following additions or corrections shall be made before — the job will be accepted Z A-5 �Puk �:3 . > REINSPECT FEE It is unlawful for any Carpenter, Contractor, Builder or other persons, to cover or cause to be covered, any part of the work with flooring, lath, earth or other material, until the proper inspector has had ample time to approve the installation. After additions or corrections have been PLUMBINGH made, call 247-5826, Building Depart- ment for an inspection. Field Inspectors ELEC are in the office-from 8:00 a.m. to 5:00 P.M. Monday through Friday, BLDG CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5826 Application Number . . . . . 04-00029391 Date 12/13/04 Property Address . . . . . . 335 6TH ST Tenant nbr, name . . . . . . IRRIGATION/SPRINKLER Application description . . . PLUMBING ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 Owner Contractor - - ------ ----- ----------- ---- - -- ------------- ---- FLOWER, GARY TARPON LANDSCAPE & DESIGN INC 335 6TH STREET 371 4TH STREET ATLANTIC BEACH FL 32233 ATLANTIC BEACH FL 32233 (904) 813-6036 (904) 710-9070 -------------------------------------------------------------- -------------- Permit . . . . . . PLUMBING PERMIT Additional desc . . Permit Fee . . . . 50 . 00 Plan Check Fee Issue Date . 00 . . . . Valuation . . . . 0 Expiration Date 6/13/05 Fee summary Charged Paid Credited Due -------- --------- --- ------- ---------- ---------- ---------- Permit Fee Total 50 . 00 50 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 50 . 00 50 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILD 4��. C i, BUILDING OFFICIAL CITY OF ATLANTIC BEACH PLUMBING PERMIT APPLICATION Date: 1Z 3- Address, Property Address: e Owner: Telephone# Contractor: V��k,/kC.Telephone# Contractor Address: 149. RV727 3,- 1 Fax t In consideration of permit given for doing tile work as described in the above statement,we hereby agree to perform said-work in accordance with the attached plans and specifications which are a part hereof and in accordance with the City of Atlantic Beach ordinance and standards of good practice listed therein. Installation of plumbing and fixtures must be in accordance with the most recent edition of the Southern Standard Plumbing Code. Plumbing Type: If other construction is being done on this building or site, V"New list the build numbqL;, El Re-Pipe Number of Fixtures: Bath Tubs Showers Closets Shower Pans Dishwashers Sinks Disposals Urinals Floor Drains Washing Machine Lavatory Water Sewer Water Heaters Other Fees Permit Issuing Fee: $35.00 Total Fixtures: X$7.00 + $35.00 800 Seminole Beach, Florida 32233-5445 eac Phone: (904) 247-5800 "(964) 2477-�584 - hftp://www.ci.atlantic-beach.fl.us Revised 1/04 cit� of Atlantic Beach *** USTOMER RECEIPT *** Oper: WITH Type: OC Drawer: Date: 4/26/04 @1 Receipt no: 51666 Descr an Quantity kount �m 26753 Bp BUILDING PERMITS 1.00 $35.N Tender detail cK CHECKS 7808 $35.W Total tendered $35.N Total paysent $35.N Trans date: 4/26/04 Time: 16-.39:51 LA d) Ilk, C"') C.2 ORI OF Dig W JOB ADDRESS DATE C), THIS JOB HAS NOT BEEN COMPLETED The following additions or corrections shall be made before the job will be accepted L 11 u,1-0 Vv U4 �7 0$�I�*-00�RREI�NSPE�CTT FE�E ��� It is unlawful for any Carpenter, Contractor, Builder or other Persons, to cover or cause to be covered, any part of the work with flooring, lath, earth or other material, until the proper inspector has had ample time to approve the installation. After additions or corrections have been made, call 247-5826, Building Depart- PLUMBING ment for an inspection. Field Inspectors ELEC are in the office'from 8:00 a.m. to 5:00 BLDG P.M. Monday through Friday, 9 12044 Dr 0 'ATLANTIC BEACH' F ---.71 PMIT INFORMATION ---- 12044 ------- LOCATION INFORMATION I------ Address,i 33S SIXTH STRUT Type:PENCE, P C,lis of Work;NEW' ATLANTIC REACH, ' p LORIDA , 32233, --------- -LZOAL DESCATPTION ---------- Type:WOOD, FRAME tot : 14/ 14, Block�: -11*p: '0 Pro0osed Use:sINoLE FAMILY Section: 0 Subd: Rng Owellin Subdivi,si-on*. ''Est Val uw: 0 .00 Impl�ov cost : 200.00 e 14tal F t 10-00 10.00 FLONQ via WNS DO ION "PLICATION-. Frzs ---------- P , Otto , 'Ad T 10 .00 dr FLORIDA Ph, 77 TI ------ Name Li i'NOTICE AM COWRETE "MS AND FOOTINGS MUST BE INSPECTED BEFORE PWR#NQ 'PESMIT VOID SIX MONTHS AFTER DATE OF ISSUE NOT PLACED IN PUBLIC Sp AC 146IN4 MATERIAL,f:OW D DEBRIS FROM THIS WORK MUST BE UPAND AW�AY EITHER CONTRACTOR OR OWNER E,AND MUST BE H�ULEO FAILURE TO 'COMPLY WITH THE MECHANIC S UIEN 14W N IN OPER" ESUL YINGTWICE FORTHIE BUJI -1 PRO EMENT .14 P LANS WHICH ARE PART OF THIS PERMIT ANE VI"P 0 ACCORDING TO APPROVED 'A�04 OF APPLICA]BLEfiROWS ION8 Of LAW. i�O6 *as TIA C A^H BUILI NTIC 13 )ING D F�MENV APPLICATION FOR FENCE PERMIT Owners name-6-cv--�I-L k-len --F I;Z) vie'r------------Phone ;I)q"l Job Address-----33 j".;L— ---------------------------- Lot.......Block and/or Unit #------------Subdivision Contractor if different from ovner-A-81ft------------------------- ----------------------------------------------------------------- Valuation of fence $-,220------- Corner or 0� lot Type construction_-PjL-,k--et-1�f---------------- Show location and height of fence as well as location of street(s) . -Four -.foo4 pOcA� 4��ce Owner signature_ Date - ---------------- Contractor signature---------------------------------Date U/?V2F y �45 OA1 A,740 C?'- 69 Z- 0 Cl 7- 17 7,7-,- 9j 14' K 14 L77--1 A-Y4 5o k, 16,Wl/ �Ar rll//,S I-Rol-�-I.?rt- -100 lZoo7s W,Vlakl 21 19 17 15 13 1 9 go 24 2-0 IG 14 10 8 14yz 3FIVENTH up Z5 Z3 2 1 1 c,) 17 is 1 :3 7 5 ......... .......... 47 L 7 2- (o 2-4 2- 2- is 14 1 z 10 8 05 Vill 0 IB Leo`j to lice OL di X, AC W ' 2-15 2-3 Z 1 19 15 13 11 17 L ---- 7) I zj,5 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FLORIDA 32233 INSPECTION PHONE LINE 247-5826 Application Number . . . . . 03-00026753 Date 4/05/04 Property Address . . . . . . 335 6TH ST Tenant nbr, name . . . . . . RENOVATE/ADD EXISTING BLD Application description . . . RESIDENTIAL ADD/RENOVATE/ALTER Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 275000 Owner Contractor ---- -------- --------- --- - ---- ------------------- FLOWER, GARY & KIM MICHAEL G. HOLDER INC 335 6TH STREET 44161 WOODRIDGE DR. ATLANTIC BEACH FL 32233 CALLAHAN FL (904) 249-7371 CALLAHAN FL 32011 (904) 721-7676 ----------------------- ----------------------- ------------------------------ Permit . . . . . . MECHANICAL PERMIT Additional desc . . Sub Contractor . . NICK' S SOLAR AND AIR Permit Fee . . . . 123 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 123 . 00 123 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 123 . 00 123 . 00 . 00 . 00 BUILDING MATERIAL,RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE,AND MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER. "FAILURE TO COMPLY WITH THE CONSTRUCTION LIEN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS-ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW. BUILDfN FFICIAL CITY OF ATLANTIC BEACH MECHANICAL PERMIT APPLICATION Date: Property Address: Owner: Telephone #: Contractor: /t/1-ck 1'r Telephone #: �79/a�gf Contractor Address: d::ti, —XAax 21-?ell,0;�tr In consideration of permit given for doing the work as described in the above statement,we hereby agree to perform said work in accordance with the attached plans and specifications which are a part hereof and in accordance with the City of Atlantic Beach ordinances and standards of good practice listed therein. Type of Heating Fuel: If other construction is being done on this building or site,list the building permit number: C3 Electric • Gas: —LP —Natural —Central Utility • Oil zu 7 S • Other-Specify MECHANICAL EQUIPMENT TO BE INSTALLED NATURE OF WORK 0 Heat _Space _Recessed —Central —Floor jOr Residential 0 Air Conditioning: Room,, ACentral Cl Duct System: Mat;iTal ;;2 Thickness 0 Commercial Maximum caorcity. -3r�2 cfm • Refrigeration Q New Building • Cooling Tower: Capacity gpm C3 Existing Building • Fire Sprinklers:Number of Heads • Elevator: —- Manlift Escalator (Number) Q Replacement of Existing System • Gasoline Pumps —(Number) El Tanks (Number) C3 New Installation Q LPG Containers (Number) (No system previously installed) C3 Unfired Pressure Vessel El Extension or Add-on to Existing System C3 Boilers C3 Gas Piping 0 Other-Specify_ Q Other-Specify LIST ALL EQUIPMENT AIR CONDITIONING,REFRIGERATION EQUIPMENT&CONDENSOR'S Approving Number Units Description Model# Manufacturer Ton's Agency �2 HEATING-FURNACES,BOILERS,FIREPLACES&AIR HANDLER'S Approving Number Units Description Model# Manufacturer BTU's Agency v4 22 V /1 14 �f Q- - 4 e_-, S-2 k: 4 t4 r-. 4 f r 21— 19P I L--11 TANKS Nominal Capacity Type Liquid Serial Approving How Man� &Dimensions Contained Manufacturer No. Agency 800 Seminole Road -Atlantic Beach,Florida 32233-5445 Phone: (904)247-5800- Fax: (904)247-5845 - http://www.ci.atlantic-beach.fl.us S1 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FLORIDA 32233 INSPECTION PHONE LINE 247-5826 Application Number . . . . . 04-00028152 Date 4/26/04 Property Address . . . . . . 335 6TH ST Tenant nbr, name . . . . . . GAS PIPING, FIREPLACE Application description . . . MECHANICAL ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 Owner Contractor ------ ------------------ ------------------------ FLOWER, GARY AEI INTERNATIONAL CORP 335 6TH STREET 719 ARLINGWOOD AVENUE ATLANTIC BEACH FL 32233 JACKSONVILLE FL 32211 ---------------------------------------------------------------------------- Permit * ' * . . . MECHANICAL PERMIT Additional desc . . Permit Fee . . . . 90 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 90 . 00 90 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 90 . 00 90 . 00 . 00 . 00 BUILDING MATERIAL,RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE,AND MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER. "FAILURE TO COMPLY WITH THE CONSTRUCTION LIEN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS"ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW. -09�- ( - BUILD G OFFICLA1 Rpr 23 04 08: 17a Cit�j of Atlantic Beach Bu 904-247-5845 P. 1 I CITY OF ATLANTIC BEACH MECHANICAL PERMIT APPLICATION Date: ';L:i 104 Property Address: Owner: F-1 0C.-c.)e Telepbone - 663(z:, Contractor: Telephone /-'J-t- I (�D A-<; K V-e-'��- Contractor Address: 7-3 qzq�, �,�4 jit,3jp Fax#: '7;21- 3-3�i& In consideration of permit gi�cn for—doing the work as described in the above statement,we hereby agree to perform said work in accordance with the attached plans and specifications which are a pan hereof and in accordance with the City of Atlantic Beach ordinances and standards of good jEactice listed therein. Type of Heating Fuel: If other construction is being done on this building or sitc�Est the building permit number: C3 Elect cXLP Central 15tility X( Gas: C3 Oil C3 -Other-Spe MECHANICAL EQUIPMENT TO BE INSTALLED NATURE OF WORK C3 Beat _Space —Recessed Central —Floor Residential C3 Air Conditioning: —Room Central C3 Duct System: Material Thickness Cbmmercial C3 Refrigeration Maximum Q New Building • Cooling Tower: Capacity- X Existing Building, • Fire Sprinklers:Number of Heads • Elevator: Manlift Escalator (Number) C1 Replacement of Existing System • Gasoline Pumps _(Number) • Tanks (Number) New histallation LPCy Containers (Number) (No system previously installed) Unfired Pressure Vessel. 3 Extension or Add-on to E�xisting Systern Cl Boilers Gas Piping 0 Other-Specify_ 0 Other-Specify— LIST ALL EQUIPMEN-,A AIR CONDI-noNING,REFRIGERATION EQUIPMENT&CONDENSOR'S Approving Number Units Description Model# Manufacturer Tot's Agency HEATING-FURNACES,BOILERS,FIREPLACE$&AIR HANDLER'S Approving Number Units Description Model# Manudwrarer BTU's Agency Walt -13-L- --�uj Ja '6—,,za--L <t5 Az- a 2 TANKS Nominal Citpacity Type Liquid Serial Approving How Man� &Dimnsioas Contained Manufacturer No. Azency k 2-C. I I I IQ -1 ,� — 6SII&t 800 Seminole Road- Atlantic Beach,Florida 32233-5445 Phone:(904)247-5800- Fax: (904)247-5845- http://www-ci.adantic-bt2Ch.fLus VICES A.& L SER LTC#NG-41 0#W917 PW 310 9378 AARON ZxPr"MW JadmonvI111%FL=254213 Phoft 0"724-9771*Not(904)721-3350 'j1j- CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FLORIDA 32233 INSPECTION PHONE LINE 247-5826 Application Number . . . . . 03-00026753 Date 12/04/03 Property Address . . . . . . 335 6TH ST Tenant nbr, name . . . . . . RENOVATE/ADD EXISTING BLD Application description . . . RESIDENTIAL ADD/RENOVATE/ALTER Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 275000 Owner Contractor ------------------------ -- --- --- -- ---- ---- - - -- - - FLOWER, GARY & KIM MICHAEL G. HOLDER INC 335 6TH STREET 44161 WOODRIDGE DR. ATLANTIC BEACH FL 32233 CALLAHAN FL (904) 249-7371 CALLAHAN FL 32011 (904) 721-7676 ------------------------------------------------------- --------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . Permit Fee . . . . 1020 . 00 Plan Check Fee 510 . 00 Issue Date . . . . 9/11/03 Valuation . . . . 275000 Expiration Date . . 3/10/04 ---------------------------------------------------------------- - --- -------- Other Fees . . . . . . . . . WATER IMPACT FEE 200 . 00 WATER CROSS CONNECTION 35 . 00 Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 1020 . 00 1020 . 00 . 00 . 00 Plan Check Total 510 . 00 510 . 00 . 00 . 00 Other Fee Total 235 . 00 235 . 00 . 00 . 00 Grand Total 1765 . 00 1765 . 00 . 00 . 00 BUILDING MATERIAL,RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE,AND MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER. "FAILURE TO COMPLY WITH THE CONSTRUCTION LIEN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS"ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW. BUILDING OFFICIAL Residential System Sizing Calculation Summary Project Title: Code Only FLOWERS Professional Version FL Climate: North 8/22/03 Location for weather data: Jacksonville - Defaults: Latitude(30) Temp Range(M) Humidity data: InteriorRH (50%) Outdoor wet bulb (7 F) Humidity difference(49gr.) Winter design temperature 32 F Summer design temperature 94 F Winter setpoint 70 F Summer setpoint 75 F Winter temperature difference 38 F Summer temperature difference 19 F Total heating load calculation 46807 Btuh Total cooling load calculation 65652 Btuh Submitted heating capacity % of calc Btuh Submitted cooling capacity % of calc Btuh Total (Electric Heat Pump) 165.8 77600 Sensible (SHR = 0.5) 73.6 38200 Heat Pump +Auxiliary(O.OkW) 165.8 77600 Latent 277.8 38200 1 Total (Electric Heat Pump) 116.4 76400_ WINTER CALCULATIONS Winter Heating Load (for 3240 sqft) Load component Load Window total 609 sqft 16748 Btuh hIll'(1 9%) Wall total 2056 sqft 11308 Btuh Wndo-s(36%) V Door total 20 sqft 357 Btuh Ceiling total 2758 sqft 4037 Btuh D....(1%) Floor total See detail report 3082 Btuh Floors(7%) Infiltration 216 cfm 9047 Btuh Subtotal 44578 Btuh eillngs(9%) Duct loss 2229 Btuh vv.11s( TOTAL HEAT LOSS 46807 Btuh SUMMER CALCULATIONS Summer Cooling Load (for 3240 sqft) Load component Load Window total 609 sqft 30340 Btuh Lederd irdernal(l I%) Wall total 2056 sqft 4441 Btuh Door total 20 sqft 212 Btuh Lt.rt hfil.(l 0 4,'1" Ceiling total 2758 sqft 4542 Btuh Floor total 90 Btuh 1nt.Galn(5%) Wndows(46%) Infiltration 189 cfm 3958 Btuh Internal gain 3600 Btuh Subtotal(sensible) 47184 Btuh Infil.(6%) Duct gain 4718 Btuh Walls( Total sensible gain 51902 Btuh Cellhgs(7%) Latent gain(inf i Itratio n) 6310 Btuh EnergyGauge@ System Sizing based on ACCA Manual J. Latent gain(internal) 7440 Btuh PREPARED BY: Total latent gain 13750 Btuh DATE: TOTAL HEAT GAIN 65662 Btuh EnergyGauge@ FLRCPB v3.30 System Sizing Calculations - Winter Residential Load - Component Details Project Title: Code Only FLOWERS Professional Version FL Climate: North Reference City: Jacksonville (Defaults) Winter Temperature Difference: 38.0 F 8/22/03 Window Panes/SHGC/Frame/U Orientation Area X HTM= Load 1 2, Clear, Metal, DEF N 20.0 27.5 550 Btuh 2 2, Clear, Metal, DEF N 30.0 27.5 825 Btuh 3 2, Clear, Metal, DEF N 9.0 27.5 248 Btuh 4 2, Clear, Metal, DEF N 17.0 27.5 468 Btuh 5 2, Clear, Metal, DEF NE 8.0 27.5 220 Btuh 6 2, Clear, Metal, DEF E 75.0 27.5 2062 Btuh 7 2, Clear, Metal, DEF E 68.0 27.5 1870 Btuh 8 2, Clear, Metal, DEF E 24.0 27.5 660 Btuh 9 2, Clear, Metal, DEF E 11.0 27.5 302 Btuh 10 2, Clear, Metal, DEF E 26.0 27.5 715 Btuh 11 2, Clear, Metal, DEF SE 8.0 27.5 220 Btuh 12 2, Clear, Metal, DEF S 30.0 27.5 825 Btuh 13 2, Clear, Metal, DEF N 18.0 27.5 495 Btuh 14 2, Clear, Metal, DEF E 22.0 27.5 605 Btuh 15 2, Clear, Metal, DEF S 22.0 27.5 605 Btuh 16 2, Clear, Metal, DEF S 20.0 27.5 550 Btuh 17 2, Clear, Metal, DEF S 28.0 27.5 770 Btuh 18 2, Clear, Metal, DEF W 13.0 27.5 358 Btuh 19 2, Clear, Metal, DEF W 60.0 27.5 1650 Btuh 20 2, Clear, Metal, DEF W 24.0 27.5 660 Btuh 21 2, Clear, Metal, DEF W 24.0 27.5 660 Btuh 22 2, Clear, Metal, DEF W 34.0 27.5 935 Btuh 23 2, Clear, Metal, DEF W 18.0 27.5 495 Btuh Window Total 609 16748 Btuh Walls Type R-Value Area X HTM= Load 1 Concrete- Exterior 5.0 2056 5.5 11308 Btuh Wall Total 2056 11308 Btuh Doors Type Area X HTM= Load 1 Insulated - Exter 20 17.9 357 Btuh Door Total 20 35713tuh Ceilings Type R-Value Area X HTM= Load 1 Under Attic 30.0 2083 1.3 2708 Btuh 2 Single Assembly 19.0 209 1.9 397 Btuh 3 Under Attic 19.0 466 2.0 932 Btuh Ceiling Total 2758 403713tuh Floors Type R-Value Size X HTM= Load 1 Raised Wood/Enclosed 11 2190.0 sqft 1.3 2847 Btuh 2 Raised Wood/Open 11 87.0 sqft 2.7 235 Btuh Floor Total 2277 3082 Btuh Infiltration Type ACH X Building Volume CFM= Load Natural 0.40 32400(sqft) 216 9047 Btuh Mechanical 0 0 Btuh Infiltration Total EnergyGauge@ FLRCPB v3.30 216 9047 Btuh Manual J Winter Calculations Residential Load - Component Details (continued) Project Title: Code Only FLOWERS Professional Version FL Climate: North 8/22/03 Subtotal 44578 Btuh Totals for Heating Duct Loss(using duct multiplier of 0.05) 2229 Btuh Total Btuh Loss 46807 Btuh Key:Window types(SHGC-Shading coefficient of glass as SHGC numerical value or as clear or tint) (Frame types-metal,wood or insulated metal) (U-Window U-Factor or'DEF'for default) (HTM-ManualJ Heat Transfer Multiplier) Key: Floor size(perimeter(p)for slab-on-grade or area for all other floor types EnergyGauge@ FLRCPB v3.30 System Sizing Calculations - Summer Residential Load - Component Details Project Title: Code Only FLOWERS Professional Version FL Climate: North Reference City.- Jacksonville (Defaults) Summer Temperature Difference: 19.0 F 8/22/03 Type Overhang Window Area(sqft) HTM Load Window Panes/SHGC/U/InSh/ExSh Ornt Len Hgt Gross Shaded Unshaded Shaded Unshaded 1 2,Clear,DEF, N, N N 15 6 20.0 0.0 20.0 23 23 460 Btuh 2 2,Clear, DEF, N, N N 1.33 5 30.0 0.0 30.0 23 23 690 Btuh 3 2,Clear, DEF, N, N N 1.33 4 9.0 0.0 9.0 23 23 207 Btuh 4 2,Clear, DEF, N, N N 1.33 5 17.0 0.0 17.0 23 23 391 Btuh 5 2,Clear, DEF, N, N NE 1.33 4 8.0 0.0 8.0 23 51 408 Btuh 6 2,Clear, DEF, N, N E 1.33 5 75.0 16.6 58.4 23 72 4587 Btuh 7 2, Clear, DEF, N, N E 1.33 6 68.0 12.5 55.5 23 72 4281 Btuh 8 2,Clear, DEF, N, N E 1.33 5 24.0 4.9 19.1 23 72 1487 Btu h 9 2,Clear, DEF, N, N E 1.33 4 11.0 1.4 9.6 23 72 723 Btuh 10 2,Clear, DEF, N, N E 1.33 5 26.0 5.8 20.2 23 72 1590 Btuh 11 2,Clear, DEF, N, N SE 1.33 5 8.0 0.0 8.0 23 63 504 Btuh 12 2,Clear, DEF, N, N S 1.33 5 30.0 30.0 0.0 23 37 690 Btuh 13 2,Clear, DEF, N, N N 1.33 5 18.0 0.0 18.0 23 23 414 Btuh 14 2,Clear, DEF, N, N E 1.33 5 22.0 3.7 18.3 23 72 1401 Btuh 15 2,Clear, DEF, N, N S 1.33 5 22.0 22.0 0.0 23 37 506 Btuh 16 2,Clear, DEF, N, N S 1.33 5 20.0 20.0 0.0 23 37 460 Btuh 17 2,Clear, DEF, N, N S 1.33 5 28.0 28.0 0.0 23 37 644 Btuh 18 2,Clear, DEF, N, N W 1.33 5 13.0 0.0 13.0 23 72 936 Btuh 19 2,Clear, DEF, N, N W 1.33 5 60.0 13.3 46.7 23 72 3669 Btuh 20 2,Clear, DEF, N, N W 1.33 4 24.0 6.6 17.4 23 72 1403 Btuh 21 2,Clear, DEF, N, N W 1.33 5 24.0 4.9 19.1 23 72 1487 Btuh 22 2,Clear, DEF, N, N W 1.33 6 34.0 5.5 28.5 23 72 2180 Btuh 23 2,Clear, DEF, N, N W 1.33 5 18.0 1.5 16.5 23 72 1223 Btuh Window Total 1 609 1 30340 Btuh Walls Type R-Value Area HTM Load 1 Concrete-Exterior 5.0 2056.0 2.2 4441 Btuh Wall Total 2056.0 4441 Btuh Doors Type Area HTM Load 1 Insulated-Exter 20.0 10.6 212 Btuh Door Total 20.0 212 Btuh Ceilings Type/Color R-Value Area HTM Load 1 Under Attic/Dark 30.0 2083.0 1.5 3041 Btuh 2 Single Assembly/Dark 19.0 209.0 2.1 447 Btuh 3 Under Attic/Dark 19.0 466.0 2.3 1053 Btu h Ceiling Total 2758.0 4542 Btuh Floors Type R-Value Size HTM Load 1 Raised Wood 11.0 2190.0 sqft 0.0 0 Btuh 2 Raised Wood 11.0 87.0 sqft 1.0 90.48 Btuh Floor Total 2277.0 90 Btuh EnergyGauge@ FLRCPB v3.30 Manual J Summer Calculations Residential Load - Component Details (continued) Project Title: Code Only FLOWERS Professional Version FL Climate: North 8/22/03 Infiltration Type ACH Volume CFM= Load Natural 0.35 32400 189.4 3958 Btuh Mechanical 0 0 Btuh Infiltration Total 189 3958 Btuh Internal Occupants Btuh/occupant Appliance Load gain 8 X 300 + 1200 3600 Btuh Subtotal 47184 Btuh Duct gain(using duct multiplier of 0.10) 4718 Btuh Total sensible gain 51902 Btuh Totals for Cooling Latent infiltration gain (for 49 gr. humidity difference) 6310 Btuh Latent occupant gain (8 people @ 230 Btuh per person) 1840 Btuh Latent other gain 5600 Btuh I TOTAL GAIN 1 65652 Btuh Key: Window types(SHGC-Shading coefficient of glass as SHGC numerical value or as clear or tint) (U-Window U-Factor or'DEFfor default) (InSh-Interior shading device: none(N), Blinds/Daperies(B)or Roller Shades(R)) (ExSh-Exterior shading device: none(N)or numerical value) (Ornt-compass orientation) EnergyGaugeO FLRCPB v3.30 FORM 60OA-2001 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: FLOWERS Builder: EMPIRE DESIGN Address: Lot: , Sub: Plat: Permitting Office: City, State: FL Permit Number: Owner: Jurisdiction Number: Climate Zone: North 1. New construction or existing New 12. Cooling systems 2. Single family or multi-family Single family a. Central Unit Cap:48.0 kBtu/hr 3. Number of units,if multi-family I SEER: 13.50 4. Number of Bedrooms 5 b. Central Unit Cap:28.4 kBtu/hr 5. Is this a worst case? Yes SEER: 12.10 6. Conditioned floor area(ft') 3240 ft' c. N/A 7. Glass area&type Single Pane Double Pane a. Clear glass,default U-factor 0.0 ft, 609.0 ft2 _ 13. Heating systems b. Default tint 0.0 ft2 0.0 111 a. Electric Heat Pump - Cap:48.0 kBtu/hr c. Labeled U or SHGC 0.0 ft2 0.0 ft2 HSPF:8.20 8. Floor types _ b. Electric Heat Pump Cap:29.6 kBtu/hr a. Raised Wood,Stem Wall ft2 - HSPF:7.60 b. Raised Wood,Post or Pier W c. N/A c. N/A 9. Wall types 14. Hot water systems a. Concrete,Int Insul,Exterior R=5.0,2056.0 ft' a. Electric Resistance Cap:65.0 gallons b. N/A EF:0.91 c. N/A b. N/A d. N/A e. N/A c. Conservation credits 10. Ceiling types (HR-Heat recovery,Solar a. Under Attic R=30.0,2083.0 ft2 DHP-Dedicated heat pump) b. Single Assembly R=l 9.0,209.0 ft2 - 15. HVAC credits PT, c. Under Attic R=I 9.0,466.0 ft 2 (CF-Ceiling fan,CV-Cross ventilation, 11. Ducts - HF-Whole house fan, a. Sup:Unc. Ret: Unc. AH(Sealed):Interior Sup.R=6.0,250.0 ft - PT-Programmable Thermostat, b. Sup:Unc. Ret:Unc. AH(Sealed):Attic Sup.R=6.0, 125.0 ft MZ-C-Multizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.19 Total as-built points: 44683 PASS Total base points: 44895 I hereby certify that the plans and specificatio, Icovered Review of the plans and oj-T14E S T44*1 by this calculation are in compli with th rida specifications covered by this AV ' �610 Energy Code. calculation indicates compliance PREPARED BY: ig M. D with the Florida Energy Code. Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 1 hereby certify that this building, as designed,is in cob W-E compliance with the Florida Energy Code. Florida Statutes. OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: EnergyGauge@(Version: FLRCPB v3.30) FORM 60OA-2001 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: Lot: , Sub: , Plat: FL, PERMIT#: BASE AS-BUILT GLASS TYPES .18 X Conditioned X BSPM Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF Points .18 3240.0 20.04 11687.3 Double,Clear S 15.0 6.0 20.0 35.87 0.44 314.3 Double, Clear S 1.3 5.0 30.0 35.87 0.84 902.0 Double,Clear S 1.3 4.0 9.0 35.87 0.78 250.5 Double, Clear S 1.3 5.0 17.0 35.87 0.84 511.1 Double,Clear SW 1.3 4.0 8.0 40.16 0.80 258.6 Double, Clear W 1.3 5.0 75.0 38.52 0.90 2604.5 Double,Clear W 1.3 6.0 68.0 38.52 0.93 2444.7 Double,Clear W 1.3 5.0 24.0 38.52 0.90 833.4 Double, Clear W 1.3 4.0 11.0 38.52 0.85 359.9 Double,Clear W 1.3 5.0 26.0 38.52 0.90 902.9 Double, Clear NVJ 1,3 5.0 8.0 25.97 0.92 190.2 Double,Clear N 1.3 5.0 30.0 19.20 0.93 536.3 Double, Clear S 1.3 5.0 18.0 35.87 0.84 541.2 Double,Clear W 1.3 5.0 22.0 38.52 0.90 764.0 Double, Clear N 1.3 5.0 22.0 19.20 0.93 393.3 Double,Clear N 1.3 5.0 20.0 19.20 0.93 357.5 Double,Clear N 1.3 5.0 28.0 19.20 0.93 500.5 Double,Clear E 1.3 5.0 13.0 42.06 0.90 492,6 Double, Clear E 1.3 5.0 60.0 42.06 0.90 2273A Double,Clear E 1.3 4.0 24.0 42.06 0.85 856.1 Double, Clear E 1.3 5.0 24.0 42.06 0.90 909.4 Double,Clear E 1.3 6.0 34.0 42.06 0.93 1333.8 Double,Clear E 1.3 5.0 18.0 42.06 0.90 682.0 As-Built Total: 609.0 19212.3 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adjacent 0.0 0.00 0.0 Concrete, Int Insul, Exterior 5.0 2056.0 1.00 2056.0 Exterior 2056.0 1.70 3495.2 Base Total: 2056.0 3495.2 As-Built Total: 2056.0 2056.0 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 0.0 0.00 0.0 Exterior Insulated 20.0 4.10 82.0 Exterior 20.0 6.10 122.0 Base Total: 20.0 122.0 1 As-Built Total: 20.0 82.01 EnergyGauge@ DCA Form 60OA-2001 EnergyGauge@/FlaRES'2001 FLRCPB v3.30 FORM 60OA-2001 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: Lot: , Sub: , Plat: FL, PERMIT#: BASE AS-BUILT CEILING TYPES Area X BSPM P Type R-Value Area X SPM X SCM = Points Under Attic 2292.0 1.73 3965.2 Under Attic 30.0 2083.0 1.73 X 1.00 3603.6 Single Assembly 19.0 209.0 5.64 X 1.00 1178.8 Under Attic 19.0 466.0 2.34 X 1.00 1090.4 Base Total: 2292.0 3965.2 As-Built Total: 2758.0 5872.8 FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Slab 0.0(p) 0.0 0.0 Raised Wood, Stem Wall 11.0 2190.0 -1.90 -4161.0 Raised 2277.0 -3.99 -9085.2 Raised Wood, Post or Pier 11.0 87.0 1.05 91.8 Base Total: -9085.2 As-Built Total: 2277.0 -4069.2 INFILTRATION Area X BSPM = Points Area X SPM = Points 3240.0 10.21 33080.4 3240.0 10.21 33080.4 Summer Base Points: 43264.9 Summer As-Built Points: 56234.3 Total Summer X System Cooling Total X Cap X Duct X System X Credit Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (DM x DSM x AHU) 56234.3 0.628 (1.090x1.147x0.86) 0.253 0.950 9843.2 56234.3 0.372 (1.090xl.147xl.05) 0.282 0.950 6497.7 43264.9 0.4266 18456.8 1 56234.3 1.00 1.160 0.263 0.950 16295.2 EnergyGauge Tm DCA Form 60OA-2001 EnergyGauge@/FlaRES'2001 FLRCPB v3.30 FORM 60OA-2001 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: Lot: , Sub: , Plat: , , FL, PERMIT#: BASE AS-BUILT GLASS TYPES .18 X Conditioned X BWPM Points Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF Pointc .18 3240.0 12.74 7430.0 Double, Clear S 15.0 6.0 20.0 13.30 3.61 960.0 Double,Clear S 1.3 5.0 30.0 13.30 1.14 454.0 Double, Clear S 1.3 4.0 9.0 13.30 1.26 150.6 Double,Clear S 1.3 5.0 17.0 13.30 1.14 257.3 Double,Clear SW 1.3 4.0 8.0 16.74 1.11 149.0 Double,Clear W 1.3 5.0 75.0 20.73 1.03 1596.2 Double, Clear W 1.3 6.0 68.0 20.73 1.02 1434.9 Double,Clear W 1.3 5.0 24.0 20.73 1.03 510.8 Double,Clear W 1.3 4.0 11.0 20.73 1.04 237.8 Double,Clear W 1.3 5.0 26.0 20.73 1.03 553.4 Double,Clear NW 1.3 5.0 8.0 24.30 1.00 195.1 Double, Clear N 1.3 5.0 30.0 24.58 1.00 739.4 Double,Clear S 1.3 5.0 18.0 13.30 1.14 272.4 Double, Clear W 1.3 5.0 22.0 20.73 1.03 468.2 Double,Clear N 1.3 5.0 22.0 24.58 1.00 542.2 Double,Clear N 1.3 5.0 20.0 24.58 1.00 492.9 Double,Clear N 1.3 5.0 28.0 24.58 1.00 690.1 Double,Clear E 1.3 5.0 13.0 18.79 1.04 254.0 Double,Clear E 1.3 5.0 60.0 18.79 1.04 11723 Double,Clear E 1.3 4.0 24.0 18.79 1.06 478.3 Double, Clear E 1.3 5.0 24.0 18.79 1.04 468.9 Double,Clear E 1.3 6.0 34.0 18.79 1.03 657.2 Double, Clear E 1.3 5.0 18.0 18.79 1.04 351.7 As-Built Total: 609.0 13086.7 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adjacent 0.0 0.00 0.0 Concrete, Int Insul,Exterior 5.0 2056.0 5.70 11719.2 Exterior 2056.0 3.70 7607.2 Base Total: 2066.0 7607.2 As-Built Total: 2056.0 11719.2 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 0.0 0.00 0.0 Exterior Insulated 20.0 8.40 168.0 Exterior 20.0 12.30 246.0 Base Total: 20.0 246.0 1 AS-Built Total: 20.0 168.01 EnergyGauge@ DCA Form 60OA-2001 EnergyGauge(D/FlaRES'2001 FLRCPB v3.3O FORM 60OA-2001 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: Lot: , Sub: , Plat: , , FL, PERMIT#: BASE AS-BUILT CEILING TYPES Area X BWPM = P R-Value Area X WPM X WCm Points Under Attic 2292.0 2.05 4698.6 Under Attic 30.0 2083.0 2.05 X 1.00 4270.1 Single Assembly 19.0 209.0 1.86 X 1.00 388.7 Under Attic 19.0 466.0 2.70 X 1.00 1258.2 Base Total: 2292.0 4698.6 As-Built Total: 2758.0 5917.1 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 0.0(p) 0.0 0.0 Raised Wood, Stem Wall 11.0 2190.0 1.20 2628.0 Raised 2277.0 0.96 2185.9 Raised Wood, Post or Pier 11.0 87.0 1.55 134.8 Base Total: 2185.9 As-Built Total: 2277.0 2762.9 INFILTRATION Area X BWPM = Points Area X WPM = Points 3240.0 -0.59 -1911.6 3240.0 -0.59 -1911.6 Winter Base Points: 20256.1 Winter As-Built Points: 31742.3 Total Winter X System Heating Total X Cap X Duct X System X Credit Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (DM x DSM x AHU) 31742.3 0.619 (1.069xl.169xO.88) 0.416 0.950 9085.9 31742.3 0.381 (1.069xl.169xl.05) 0.449 0,950 6045.3 20256.1 0.6274 12708.7 31742.3 1.00 1.171 0.428 0.950 15110.6 EnergyGauge T" DCA Form 60OA-2001 EnergyGauge@/FlaRES'2001 FLRCPB v3.30 FORM 60OA-2001 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS: Lot: , Sub: , Plat: FL, PERMIT#: BASE AS-BUILT WATER HEATING Number of X Multiplier Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 5 2746.00 13730.0 65.0 0.91 5 1.00 2655.47 1.00 13277.4 I As-Built Total: 13277.4 CODE COMPLIANCE STATUS BASE AS-BUILT Cooling + Heating + Hot Water Total Cooling + Heating + Hot Water Total Points Points Points Points Points Points Points Points 18457 12709 13730 44895 j_ 16295 15111 13277 44683 PASS RiUE SP44 lift, EnergyGauge'll DCA Form 60OA-2001 EnergyGauge@/FlaRES'2001 FLRCPB v3.30 FORM 60OA-2001 Code Compliance Checklist Residential Whole Building Performance Method A - Details �ADDRESS-. Lot: , Sub: , Plat: , FL, PERMIT#-. 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST TREQUIREMENTS FOR EACH PRACTICE COMPONENTS 'I'SE TON CHECK Exterior Windows&Doors 606.1.ABC.1.1 1: Maximum:.3 cfm/sq.ft.window area; .5 cfm/sq.ft. door area. Exterior&Adjacent Walls 606.1.ABC.1.2.1 I-Caulk.,g-asket-,weatherstrip or seal between:window-s/doors&frames, su rrounding wall; foundation&wall sole or sill plate;joints between exterior wall panels at corners; utility penetrations;between wall panels&top/bottom plates;between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from-,-and is sealed to,th-e foundation to the top-plate. Floors 606.1.ABC.1.2.2 Penetrations/openings>1/8"sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the-perimeter,penetrations and seams. Ceilings 606.1.ABC.1.2.3 Between walls&ceilings;penetrations of ceiling plane of top floor; around shafts,chases, soffits, chimneys,cabinets sealed to continuous air barrier;gaps in gyp board&top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at theperimeter,at penetrations-and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations,sealed;or Type IC or non-IC rated, installed inside a sealed box with 1/2"clearance&3"from insulation; or Type IC rated with<2.0 cfm from conditioned space,tested. Multi-story Houses 606.1ABCA.2.5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors,dampers; combustion space heaters comply with NFPA, have combustion air. 6A-22 OTHER-PRESCRIPT-IVE MEASURES (must be met or exceeded by all residences.) COMPONENTS !—SECTION REQUIREMENTS CHECK Water Heaters 612.1 Comply with efficiency requirements in Table 6-12. Switc h or clearly marked circuit -breaker(electric, or cutoff�gas)must be pro-v-id-ed.-External or built-in heat trap required, Spas&heated pools must have covers(except solar heated). Non-commercial pools Swimming Pools&Spas 612.1 must have a pump timer.Gas spa&pool heaters must have a minimum thermal efficiency of 78%. Showerheads 1612.1 Water flow must be restricted to no more than 2.55 gallons er minute at 80 PSIG. _p Air Distribution Systems 610.1 All ducts,fittings, mechanical equipment and plenum chambers shall be mechanically attached,sealed, insulated,and installed in accordance with the criteria of Section 610. 1 Ducts in unconditioned attics: R-6 min. insulation. Separate HVAC Co-ntrols 607.1 readily access-iblemanual-o-ra-utomatic thermost-at for--each system. Insulation 604.1,602.1 Ceilings-Min. R-1 9.Common walls-Frame R-1 1 or CBS R-3 both sides. Common ceiling&floors R-1 1. EnergyGauge Tm DCA Form 60OA-2001 EnergyGauge@/FlaRES'2001 FLRCP13 v3.30 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* 83.6 The higher the score,the more efficient the home. Lot: , Sub: , Plat: FL, 1. New construction or existing New - 12. Cooling systems 2. Single family or multi-family Single family _ a. Central Unit Cap:48.0 kBtu/hr 3. Number of units,if multi-family I - SEER: 13.50 4. Number of Bedrooms 5 - b. Central Unit Cap:28.4 kBtu/hr 5. Is this a worst case? Yes - SEER: 12.10 6. Conditioned floor area(ft') 3240 ft2 c. N/A 7. Glass area&type Single Pane Double Pane - a. Clear-single pane 0.0 ft, 609.0 ft2 _ 13, Heating systems b. Clear-double pane 0.0 ft, 0.0 ft2 _ a. Electric Heat Pump Cap:48.0 kBtu/hr c. Tint/other SHGC-single pane 0.0 ft, 0.0 ft2 _ HSPF:8.20 d. Tint/other SHGC-double pane b. Electric Heat Pump Cap:29.6 kBtu/hr 8. Floor types - HSPF:7.60 a. Raised Wood,Stem Wall R=1 1.0,2190.0W c. N/A b. Raised Wood,Post or Pier R=I 1.0,87.0ft2 c. N/A 14. Hot water systems 9. Wall types - a. Electric Resistance Cap:65.0 gallons a. Concrete,Int Insul,Exterior R=5.0,2056.0 ft' - EF:0.91 b. N/A b. N/A c. N/A d. N/A c. Conservation credits c. N/A (HR-Heat recovery,Solar 10. Ceiling types DHP-Dedicated heat pump) a. Under Attic R=30.0,2083.0 W - 15. HVAC credits PT, b. Single Assembly R=I 9,0,209.0 W - (CF-Ceiling fan,CV-Cross ventilation, c. Under Attic R=19.0,466.0 ft' HF-Whole house fan, 11. Ducts - PT-Programmable Thermostat, a. Sup:Unc. Ret:Unc. AH(Sealed):Interior Sup.R=6.0,250.0 ft - MZ-C-Multizone cooling, b. Sup:Unc. Ret: Unc. AH(Sealed):Attic Sup.R=6.0, 125.0 ft MZ-H-Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above energy saving features which will be installed(or exceeded) 1_,Tj4E Sr4 in this home before final inspection. Otherwise,a new EPL Display Card will be completed 0, based on installed Code compliant features. 0 Builder Signature: Date: Address of New Home: City/FL Zip: WE *NOTE: The home's estimated energy performance score is only available through the FLAIRES computer program. This is not a Building Energy Rating. Ifyour score is 80 or greater(or 86for a US EPAIDOE EnergyStarTmdesignation), your home may qualifyfor energy efficiency mortgage(EEM) incentives ifyou obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 3211638-1492 or see the Energy Gauge web site at www.'/sec.ucf edu'for information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 8501487-1824. EnergyGauge(b(Version: FLRCPB v3.30) C CITY OF ATLANTIC BEACH BUILDING / ZONING DEPARTMENT L. Higains 800 Seminole Road Atlantic Beach,Florida 32233 (904)247-5800 C I'll (904)247-5845 Fax PLAN REVIEW COMMENTS Permit Application # 03- 2,7s4-7 Property Address: :iT— Applicant: 4z L-DcfF�. Project: =Qc�&I ATI(SISJ -4 41�0 M 6 t1d This permit application has been: ED Approved F--] Reviewed and the following items need attention: nex- V2AIN 14aA4LU Please re-submit your application when these items hav e been completed. Reviewed By: Date:' CITY OF ATLANTIC BEACH BUILDING PERMIT APPLICATION (ALTERATIONS/ADDITIONS) Date: Job Address: Owner of Property: a4qA Address: 3.3,5— 4.44 517— Telephone: Legal Description: Block Number: LotNumber: -It/4 /9 ZoningDistrict: Contractor: M169ACL State License Number: C-661 Contractor's Address: JN/ 64— -32011 Telephone: _'Mit— 7A1- 71,74, Fax: go — 7.X — y / 7.2 6 J� Describe proposed use and work to be done: 14-OUS-Z —RE)0,0 VAT7,q.) 7�,Oj Present use of land or building(s): Valuation of proposed construction: What are the dimensions of the added space: 2 JV feet x 340 feet Will the added area be heated and cooled? New electrical or increase in service? Add plumbing fixtures? Add fireplace? YJ 1, Add heating/air conditioning?.. !?in/* Is approval of Homeowner's Association or other private entity required?_If yes, please submit with this application, Will th ,Wproject involve changes in elevation,site grade or any use of fill material or the removal of any trees? NO. Applicant certifies that no change in site grade or fill material will be used on this project. YES. See Step 2 below. Approval of the Public Works Department is required prior to issuance of a Building Permit. [?�NO. Applicant certifies that no trees will be removed for this project. 0 YES. Removal of Trees will be required for this project. TREE REMOVAL PERMIT IS REQUIRED. Tree Removal Permits to be reviewed by the Tree Conservation Board,which meets two times each month. Procedure: In order to expedite issuance of permits, please follow all steps and provide all information as appropriate Incomplete applications may result in delay in issuance of permit STEP 1. Verify zoning designation and proper setbacks for the proposed construction. If you are unsure of this information, please contact the Planning and Zoning Department at 904-247-5826. In order to correctly verify zoning designation, please have Property Appraiser's Real Estate Number available. STEP 2. Contact the City of Atlantic Beach Department of Public Works to determine if a pre-construction or post-construction topographical survey or grading plan is required. (If not required, written verification must be provided with this application.) The Department of Public Works is located at: 1200 Sandpiper Lane,Atlantic Beach,FL 32233 Telephone:(904)247-5834 STEP 3. Submit Tree Removal Application if trees are to be removed or relocated. STEP 4. Please submit Building Permit Application, Energy Code Forms, Notice of Commencement, Owner/Contractor Affidavit if owner is contractor,and four(4)complete sets of construction plans to the Building Department,which is located at the Atlantic Beach City Hall,800 Seminole Road,Atlantic Beach,FL 32233 Telephone:(904)247-5826 800 Seminole Road -Atlantic Beach,Florida 32233-5445 Page I Telephone: (904)247-5800 -Fax: (904)247-5845 -http://www.ci.atlantic-beach.fl.us Revised 1/14/03 'in addition to construction and engineering detail,plans must contain the following information as appropriate for the type of work being performed. Scale of drawings should be sufficient to depict all required information in a clear and legible manner. 1. Current survey showing the property boundary with bearings and distances and the legal description. 2. Location of all structures,temporary and permanent,including setbacks,building height,number of stories and square footage. Identify any existing structures and uses. 3. If required by the Department of Public Works,a pre-construction topographical survey. 4. Any significant environmental features,including any jurisdictional wetlands,CCCL,natural water bodies. 5. Impervious Surface area calculations: include driveways, sidewalks, patios and other Impervious Surfaces. Swimming pools may be excluded from total Impervious Surface. 6. Other information ams may be priate for indivi ual applications. I hereby certify that all infornmn provide i plication is correct. Signature of owner: Date: I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of the laws and ordinances governing this type of work will be complied with, whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any federal,state or local rules,regulations,ordinances,or laws in any manner,including the governing of construction or the performance of construction of the property. I understand that the issuance of this permit is contingent upon the above information being true and correct and that the plans and supporting data have been or sliall be provided as required. Signature of Contractor: Date: Address and contact information of person to receive all correspondence regarding this application (please print). Name: Mailing Address: Telephone: Fax: E-Mail: AS TO OWNER: Sworn to and subscribed before me this :Q day of X_/91111 2 0 0',5 State of Florida,County of Duval Notary's Signature: Roxanne Rader Q­11e'rsonally known MYCOMMISSION# DD023830 EXPIRES FJ Produced identificatti r May 7,2005 FAIN INSURANCL INC Type of identification pro uced'ON"D THRu TROY AS TO CONTRACTOR: Sworn to and subscribed before me this day of 20 -P State of Florida,County of Duval Notary's Signature: Roxanne Rader 9-fersonally known MYCOMMISS*N# MUM EXPIRES 'Z Produced identification May 7,2005 5ONDID THRU TROY FAJN INSLWANCk INC Type of identification pro(rdco 800 Seminole Road -Atlantic Beach,Florida 32233-5445 Page 2 Telephone: (904)247-5800 -Fax: (904)247-5845 -http://www.ci.atlantic-beach.fl.us Revised 1/14/03 08/21/2003 14:25 9047249154 DURDEN SURVEY PAGE 02/02 MAP SHOWING BOUNDARY7URVEY OF.- LOTS 14, 16 AND 18. 13LOCK B. SUBDPASION *A-. ATLANTIC BEACH, AS RECORDED IN PLAT BOOK 5. PACE 659 OF THE CURREN' PU13LJC RECORDS OF' DUVAL COUNTy, FLORIDA LOT 19 LOT 17 LOT la LOT 13 LOT 11 150.00, MWO 112 RM Pre 2 1/;!-ffm pf;w LAJ > LOT 20 ......... ....... . Of LOT 12 lz u- 0 Z2 (0 nXM 112�OtON Pre NO IOMFICAMN mw. kr.s� FWW I/Z,hwm PIPE 150,00' MVXV 112-NM—C FWhV 112-NOW PPE NO VMMATON NO 0&rWlCA?*N SIXTH STREET 40' RIGHT—OF—WAY AVIM WS FROPOttr Lin Av F"xx;zmLr Fum A"p REV=N"L 17, Ifft C06"ftM pApa Na 12007.5 A-1 Owl 0 Au ft?tRov man Apz Krw'oo-AS jfrAst#z0 AW pvsf�= No au&pw msmzmN Lwr ay PLAr ALL LOn StOW HM-ON LC WTWN KOCK a EXCZ�A, mrM CtRTIRED TO: X—00'C7M 4'C�WN LAVK FZNCE 0MtPT AS NOTED GARY F. FLOWER //—0rhWM 5' KtVD POICE MM AS NOTM TWRE k4Y St AOOffOJAL ftwxcromn —r ARe mor sNam oN SE FOU&O W RMORM OF I hmmhy owijfy that meeft the ftdnknuM t aW wt ft4h by 11IN&FkwMq 90&d af Larmf Jwv� Purwount to D 0 MAPPING 'n-'.r .ad Z, soction 027 and D U R D E N SLJRV"E)lNG AND MAPPING. INC. 8150 Lonowtur Road V to, Floldc 3Z211 1 (904) 724-5!1�08 Fox 721-7845 MOR'DA KGIWWM RMNV" 4707 WED DUCfNt*U No. geoe oftoc SICNED AlJdu iT 1,3, 2003 SCQ.E: 743 SURVEY W vAuD LIKM THS PRINT IS !MWS= IMIH T14E sWAL OF 7WE AWW sollm. B-3165 Residentia I System Sizing Calculation Summary Project Title: Code Only FL FLOWERS Professional Version Climate: North Location for weather data: Jacksonville - Defaults: Latitude(30) Temp Range(M) Humidi rin+,- 1-4—:– )utdoor wet bulb( F) Humidity difference(49gr.) Winter design temperature 32 F 'Summer design temperature 94 F Winter setpoint 0 70 F Summer setpoint Winter tem erature difference 38 F 75 F Summer temperature difference 19 F 0: B Total heatin load calculation 46807 Btu4h :Total cooling load c alculation 65652 Btuh Submitted heating capacity % of calc Btuh Submitted cooling capacity % of calc Btuh Total (Electric Heat Pump) 165.8 77600 Sensible (SHR = 0.5) 73.6 38200 Heat Pump+Auxiliary(O.OkW) 165.8 77600 Latent 277.8 38200 ctric Heat Pump) 116.4 76400 WINTER CALCULATIONS Winter Heating Load (for 3240 Load component Load Dut.(5%) Window total 609 sqft 16748 Btuh infil.(19%) Wall total 2056 sqft 11308 Btuh ows(36%) Door total 20 sqft 357 Btuh Ceiling total 2758 sqft 4037 Btuh D.�.(l%) Floor total See detail report 3082 Btuh Floors(7%) Infiltration 216 cfm 9047 Btuh Subtotal 44578 Btuh Duct loss 2229 Btuh VVW1.(24%) TOTAL HEAT LOSS 46807 Btuh SUMMER CALCULATIONS Summer Cooling Load (for 3240 sqft) Load component Load Window total 609 sqft 30340 Btuh Laterd"ernal(l 1%) Wall total 2056 sqft 4441 Btuh ;ddmmmmmlb.- Door total 20 sqft 212 Btuh Lat.,d infil.(l 0%) Ceiling total 2758 sqft 4542 Btuh Floor total 90 Btuh VV."do-S(46%) Infiltration 189 cfm 3958 Btuh Internal gain 3600 Btuh Ducts(7%) Subtotal(sensible) 47184 Btuh Duct gain 4718 Btuh IWO.(I VV*118(7%) Total sensible gain 51902 Btuh C.ffing.(7%) Latent ga in(infiltration) 6310 Btuh Latent gain(internal) 7440 Btuh EnergyGauge@ System Sizing based on ACCA Manual J. Total.latent gain 13750 Btuh PREPARED BY: TOTAL HEAT GAIN 65652 Btuh DATE: EnergyGaugeO FLRCPB v3.30 System Sizing Calculations - Winter Residential Load - Component Details Project Title: Code Only FL FLOWERS Professional Version Climate: North Reference City: Jacksonville (Defaults) Winter Temperature Difference: 38.0 F 8/22/03 Window Panes SHGC/Frame/U Orientation Area X HTM= Load 1 2, Clear, Metal, DEF N 20.0 27.5 550 Btuh 2 2, Clear, Metal, DEF N 30.0 27.5 825 Btuh 3 2, Clear, Metal, DEF N 9.0 27.5 248 Btuh 4 2, Clear, Metal, DEF N 17.0 27.5 468 Btuh 5 2, Clear, Metal, DEF NE 8.0 27.5 220 Btuh 6 2, Clear, Metal, DEF E 75.0 27.5 2062 Btuh 7 2, Clear, Metal, DEF E 68.0 27.5 1870 Btuh 8 2, Clear, Metal, DEF E 24.0 27.5 660 Btuh 9 2. Clear, Metal, DEF E 11.0 27.5 302 Btuh 10 2, Clear, Metal, DEF E 26.0 27.5 715 Btuh 11 2, Clear, Metal, DEF SE 8.0 27.5 220 Btuh 12 2, Clear, Metal, DEF S 30.0 27.5 825 Btuh 13 2, Clear, Metal, DEF N 18.0 27.5 495 Btuh 14 2, Clear, Metal, DEF E 22.0 27.5 605 Btuh 15 2, Clear, Metal, DEF S 22.0 27.5 605 Btuh 16 2, Clear, Metal, DEF S 20.0 27.5 550 Btuh 17 2, Clear, Metal, DEF S 28.0 27.5 770 Btuh 18 2, Clear, Metal, DEF W 13.0 27.5 358 Btuh 19 2, Clear, Metal, DEF W 60.0 27.5 1650 Btuh 20 2, Clear, Metal, DEF W 24.0 27.5 660 Btuh 21 2, Clear, Metal, DEF W 24.0 27.5 660 Btuh 22 2, Clear, Metal, DEF W 34.0 27.5 935 Btuh 23 2, Clear, Metal, DEF W 18.0 27.5 495 Btuh Window Total 609 16748 Btuh Walls Type R-Value Area X HTM= Load 1 Concrete- Exterior 5.0 2056 5.5 11308 Btuh Wall Total 2056 11308 Btuh Doors Type Area X HTM= Load 1 Insulated - Exter 20 17.9 357 Btuh Door Total 20 35713tuh Ceilings Type R-Value Area X HTM= Load 1 Under Attic 30.0 2083 1.3 2708 Btuh 2 Single Assembly 19.0 209 1,9 397 Btuh 3 Under Attic 19.0 466 2.0 932 Btuh Ceilinq Total 2758 403713tuh Floors Type R-Value Size X HTM= Load 1 Raised Wood/Enclosed 11 2190.0 sqft 1.3 2847 Btuh 2 Raised Wood/Open 11 87.0 sqft 2.7 235 Btuh Floor Total 2277 3082 Btuh Infiltration Type ACH X Building Volume CFM= Load Natural 0.40 32400(sqft) 216 9047 Btuh Mechanical 0 0 Btuh Infiltration Total EnergyGauge(@ FLRCPB v3.30 216 9047 Btuh Manual J Winter Calculations Residential Load - Component Details (continued) Project Title: Code Only FL FLOWERS Professional Version Climate: North 8/22/03 I Subtotal 44578 Btuh Totals for Heating Duct Loss(using duct multiplier of 0.05) 2229 Btuh Total Btuh-Loss 46807 Btuh Key:Window types(SHGC-Shading coefficient of glass as SHGC numerical value or as clear or tint) (Frame types-metal,wood or insulated metal) (U-Window U-Factor or'DEF'for default) (HTM-ManualJ Heat Transfer multiplier) Key:Floor size(perimeter(p)for slab-on-grade or area for all other floor types EnergyGaugeS FLRCPB v3.30 System Sizing Calculations - Summer Residential Load - Component Details Project Title: Code Only FL FLOWERS Professional Version Climate: North Reference City: Jacksonville (Defaults) Summer Temperature Difference: 19.0 F 8/22/03 Type Overhang Window Area HT Load Window panes/SHGC/U/InSh/ExSh Ornt Len H t Gross (S'ft) 2,Clear,DEF, N,N N 15 6 Shaded Unshaded Sh ded Unshaded P 2 a n C, HTM haded s iaded Shade C IT d Un 1 5 6 20.0 0.0 20.0 23 23 460 Btuh 2 2,Clear, DEF,N, N N fl.33 5 30.0 0.0 30.0 23 23 690 Btuh 3 2,Cl,ear, DEF, N, N N 1.33 4 9.0 0.0 9.0 23 23 207 Btuh 4 2.Cl,ear, DEF, N, N N 1.33 5 17.0 0.0 17.0 23 23 391 Btuh 5 2, Clear, DEF, N, N NE 1.33 4 8.0 0.0 8.0 23 51 408 Btuh 6 2,Clear, DEF, N, N E 1.33 5 75.0 16.6 58.4 23 72 4587 Btuh 7 [2, Clear, DEF, N,N E 1.33 6 68.0 12.5 55.5 23 72 4281 Btuh 8 2,Clear,DEF, N, N E 1.33 5 24.0 4.9 19.1 23 72 1487 Btuh 9 2,Clear, DEF, N,N E 1.33 4 11.0 1.4 9.6 23 72 723 Btuh 10 2,Clear,DEF, N, N E 1.33 5 26.0 5.8 20.2 23 72 1590 Btuh 11 2,Clear, DEF, N, N SE 1.33 5 8.0 0.0 8.0 23 63 504 Btuh 12 2,Clear, DEF, N, N S 1.33 5 30.0 30.0 0.0 23 37 690 Btuh 13 2,Clear, DEF, N, N N 1.33 5 18.0 0.0 18.0 23 23 414 Btuh 14 2,Clear, DEF,N, N E 1.33 5 22.0 3.7 18.3 23 72 1401 Btuh 15 2,Clear,DEF, N, N S 1.33 5 22.0 22.0 0.0 23 37 506 Btuh 16 2,Clear, DEF, N,N S 1.33 5 20.0 20.0 0.0 23 37 460 Btuh 17 2,Clear, DEF, N, N S 1.33 5 28.0 28.0 0.0 23 37 644 Btuh 18 2, Clear,DEF, N, N W 1.33 5 13.0 0.0 13.0 23 72 936 Btuh 19 2,Clear, DEF,N, N W 1.33 5 60.0 13.3 46.7 23 72 3669 Btuh 20 2,Clear, DEF, N, N W 1.33 4 24.0 6,6 17.4 23 72 1403 Btuh 21 2,Clear, DEF, N, N W 1.33 5 24.0 4.9 19.1 23 72 1487 Btuh 22 2,Clear, DEF, N, N W 1.33 6 34.0 5.5 28.5 23 72 2180 Btuh 23 2,Clear, DEF, N,N W 1.33 5 18.0 1.5 16.5 23 72 1223 Btuh Window Total 609 Type R-Value Area HTM Load Walls 30340 Btuh 1 Concrete-Exterior 5.0 2056.0 2.2 4441 Btuh Wall Total 2056.0 4441 Btuh Doors Type Area HTM Load Insulated-Exter 20.0 10.6 212 Btuh Door Total 20.0 212 Btuh Ceilings Type/Color R-Value Area HTM Load I Under Attic/Dark 30.0 2083.0 1.5 3041 Btuh 2 Single Assembly/Dark 19.0 209.0 2.1 447 Btuh 3 Under Attic/Dark 19.0 466.0 2.3 1053 Btuh Ceilinq Total -- 2758.0 4542 Btuh Floors Type R-Value Size HTM Load I Raised Wood 11.0 2190.0 sqft 0.0 0 Btuh 2 Raised Wood 11.0 87.0 sqft 1.0 90.48 Btuh Floor Total 2277.0 90 Btuh EnergyGaugeO FLRCPB v3.30 Manual J Summer Calculations Residential Load - Component Details (continued) Project Title: Code Only FL FLOWERS Professional Version Climate: North 8/22/03 Infiltration Type ACH Volume CFM= Load Natural 0.35 32400 189.4 3958 Btuh l' Mechanical In fil.--tion Total 0 n Pf..k .1 on I Occupants Btuh/occupant Applian�ce �Load�� 8 X 300 + �1200 3600 Btuh Subtotal - 47184 Btuh Duct gain(using duct multiplier of 0.10) 4718 Btuh c, ., . Total sensible gain F51902 Btuh Totals for Cooling Latent infiltration gain (for 49 gr. humidity difference) 6310 Btuh Latent occupant gain (8 people @ 230 Btuh per person) 1840 Btuh Latent other gain 5600 Btuh I TOTAL GAIN - 65652 Btuh Key: Window types(SHGC-Shading coefficient of glass as SHGC numerical value or as clear or tint) (U-Window U-Factor or'DEFfor default) (InSh-Interior shading device: none(N), Blinds/Daperies(B)or Roller Shades(R)) (ExSh-Exterior shading device: none(N)or numerical value) (Ornt-compass orientation) EnergyGaugeO FLRCPB v3.30 FOPM 60OA-2001 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department Of Community Affairs Residential Whole Building Performance Method A Project Name: FLOWERS Address: Lot: , Sub: Plat: Builder: EMPIR 9--DES I G_ N City, State: FL Permitting Office: Owner: Permit Number: Climate Zone: North Jurisdiction Number: I New construction or existing New - 12. Cooling systems 1 2. Single family or multi-family Single family _ a. Central Unit 3. Number of units,if multi4amily Cap:48.0 kBtu/hr 4. Number of Bedrooms 5 b. Central Unit SEER: 13.50 5. Is this a worst case? Cap:28.4 kBtu/hr Yes 6. Conditioned floor area(ft') SEER: 12.10 3240 ft, c. N/A 7. Glass area&type Single Pane Double Pane a. Clear glass,default U-factor 0.0 111 609.0 ft, 13. Heating systems b. Default tint 0.0 ft, 0.0 ft, a. Electric Heat Pump Cap:48.0 kBtu/hr c. Labeled U or SHGC 0.0 ft2 8. Floor types 0.0 ft, HSPF:8.20 - b. Electric Heat Pump Cap:29.6 kBtu/hr a. Raised Wood,Stem Wall ft2 - b. Raised Wood,Post or Pier ft2 c. N/A HSPF:7.60 - c. N/A - 9. Wall types - 14. Hot water systems a, Concrete,Int Insul,Exterior R=5.0,2056.0 ft2 1 1 b. N/A - I I a. Electric Resistance Cap:65.0 gallons c. N/A - b. N/A EF:0.91 d. N/A - e. N/A I c. Conservation credits 10. Cei I ing types (HR-Heat recovery,Solar a. Under Attic R=30.0,2083.0 DHP-Dedicated heat pump) ft2 b. Single Assembly R=19.0,209.0 ft, c. Under Attic R=19.0,466.0 ft2 15. HVAC credits PT, (CF-Ceiling fan,CV-Cross ventilation, 11. Ducts HF-Whole house fan, a. Sup:Unc. Ret:Unc. AH(Sealed):Interior Sup.R=6.0,250.0 ft PT-Programmable Thermostat, b. Sup:Unc. Ret:Unc. AH(Sealed):Attic Sup.R=6.0, 125.0 11 i MZ-C-Multizone cooling, MZ-H-Multizone heating) Total as-built points: 44683 Glass/Floor Area: 0.19 Total base points: 44895 PASS I hereby certify that the plans and specifi at* overed Review of the plans and "c 111E Sr4 by this calculation are in compl, with th''op-Thida specifications covered by this Ivo Energy Code. calculation indicates compliance eo PREPARED BY: 19 M. D with the Florida Energy Code. A� fill Before construction is completed DATE: this building will be inspected for I hereby certify that this building, as designed,�s in compliance with Section 553.908 compliance with the Florida Energy Code. Florida Statutes. Ob w-B OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: EnergyGaugeg(Version: FLRCPB v3.30) FORM 60OA-2001 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details Plat: , FL, PERMIT#: BASE AS-BUILT GLASS TYPES .18 X Conditioned X BSPM Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF Points 18 3240.0 20.04 11687.3 Double,Clear S 15.0 6.0 20.0 35.87 0.44 314.3 Double,Clear S 1.3 5.0 30.0 35.87 0.84 902.0 Double,Clear S 1.3 4.0 9.0 35.87 0.78 250.5 Double,Clear S 1.3 5.0 17.0 35.87 0.84 511.1 Double,Clear SW 1.3 4.0 8.0 40.16 0.80 258.6 Double,Clear W 1.3 5.0 75.0 38.52 0.90 2604.5 Double,Clear W 1.3 6.0 68.0 38.52 0.93 2444.7 Double,Clear W 1.3 5.0 24.0 38.52 0.90 833.4 Double,Clear W 1.3 4.0 11.0 38.52 0.85 359.9 Double,Clear W 1.3 5.0 26.0 38.52 0.90 902.9 Double,Clear NW 1.3 5.0 8.0 25.97 0.92 190.2 Double,Clear N 1.3 5.0 30.0 19.20 0.93 536.3 Double,Clear S 1.3 5.0 18.0 35.87 0.84 541.2 Double,Clear W 1.3 5.0 22.0 38.52 0.90 764.0 Double,Clear N 1.3 5.0 22.0 19.20 0.93 393.3 Double, Clear N 1.3 5.0 20.0 19.20 0.93 357.5 Double,Clear N 1.3 5.0 28.0 19.20 0.93 500.5 Double, Clear E 1.3 5.0 13.0 42.06 0.90 492.6 Double,Clear E 1.3 5.0 60.0 42.06 0.90 2273.4 Double,Clear E 1.3 4.0 24.0 42.06 0.85 856.1 Double, Clear E 1.3 5.0 24.0 42.06 0.90 909.4 Double,Clear E 1.3 6.0 34.0 42.06 0.93 1333.8 Double,Clear E 1.3 5.0 18.0 42.06 0.90 682.0 As-Built Total: 609.0 19212.3 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adjacent 0.0 0.00 0.0 Concrete, Int Insul, Exterior 5.0 2056.0 1.00 2056.0 Exterior 2056.0 1.70 3495.2 Base Total: 2056.0 3495.2 As-Built Total: 2056.0 2056.0 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 0.0 0.00 0.0 Exterior Insulated 20.0 4.10 82.0 Exterior 20.0 6.10 122.0 Base Total: 20.0 122.0 1 As-Built Total: 20.0 82.01 EnergyGauge(D DCA Form 60OA-2001 EnergyGaugeO/FlaRES'2001 FLRCPB v3.30 FORM 60OA-2001 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: Lot: , Sub: Plat: FL, PERMIT#: BASE AS-BUILT CEILING TYPES Area X BSPIVI 4PointsType R-Value Area X SPM X sCM Points Under Attic 2292.0 1.73 3965.2 Under Attic 30.0 2083.0 1.73 X 1.00 3603.6 Single Assembly 19.0 209.0 5.64 X 1.00 1178.8 Under Attic 19.0 466.0 2.34 X 1.00 1090.4 Base Total: 2292.0 3965.2 As-Built Total: 2758.0 5872.8 FLOOR TYPES Area X BSPM Points Type R-Value Area X SPM Points Slab 0.0(p) 0.0 0.0 Raised Wood, Stem Wall 11.0 2190.0 -1.90 -4161.0 Raised 2277.0 -3.99 -9085.2 Raised Wood, Post or Pier 11.0 87.0 1.05 91.8 Base Total: -9085.2 As-Built Total: 2277.0 -4069.2 INFILTRATION Area X BSPM Points Area X SPM Points 3240.0 10.21 33080.4 3240.0 10.21 33080.4 Summer Base Points: 43264.9 Summer AS-Built Points: 56234.3 TotalSummer X System Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (DM x DSM x AHU) 56234.3 0.628 (1.090x1.147x0.86) 0.253 0.950 9843.2 56234.3 0.372 (1.090xl.147xl.05) 0.282 0.950 6497.7 43264.9 0.4266 18456.8 56234.3 1.00 1.160 0.263 0.950 162951.2 EnergyGaugeTm DCA Form 60OA-2001 EnergyGaugeg/FlaRES'2001 FLRCPB v3.30 FORM 60OA-2001 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: Lot: , Sub: , Plat: FL, PERMIT#: BASE AS-BUILT GLASS TYPES 1 .18 X Conditioned X BWPM Points Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF Point,, .18 3240.0 12.74 7430.0 Double, Clear S 15.0 6.0 20.0 13.30 3.61 960.0 Double,Clear S 1.3 5.0 30.0 13.30 1.14 454.0 Double,Clear S 1.3 4.0 9.0 13.30 1.26 150.6 Double,Clear S 1.3 5.0 17.0 13.30 1.14 257.3 Double, Clear SW 1.3 4.0 8.0 16.74 1.11 149.0 Double, Clear W 1.3 5.0 75.0 20.73 1.03 1596.2 Double,Clear W 1.3 6.0 68.0 20.73 1.02 1434.9 Double,Clear W 1.3 5.0 24.0 20.73 1.03 510.8 Double,Clear W 1.3 4.0 11.0 20.73 1.04 237.8 Double, Clear W 1.3 5.0 26.0 20.73 1.03 553.4 Double,Clear NW 1.3 5.0 8.0 24.30 1.00 195.1 Double,Clear N 1.3 5.0 30.0 24.58 1.00 739.4 Double, Clear S 1.3 5.0 18.0 13.30 1.14 272.4 Double,Clear W 1.3 5.0 22.0 20.73 1.03 468.2 Double, Clear N 1.3 5.0 22.0 24.58 1M 542.2 Double, Clear N 1.3 5.0 20.0 24.58 1.00 492.9 Double,Clear N 1.3 5.0 28.0 24.58 1.00 690.1 Double,Clear E 1.3 5.0 13.0 18.79 1.04 254.0 Double, Clear E 1.3 5.0 60.0 18.79 1.04 1172.3 Double, Clear E 1.3 4.0 24.0 18.79 1.06 478.3 Double,Clear E 1.3 5.0 24.0 18.79 1.04 468.9 Double,Clear E 1.3 6.0 34.0 18.79 1.03 657.2 Double, Clear E 1.3 5.0 18.0 18.79 1.04 351.7 As-Built Total: 609.0 13086.7 WALL TYPES Area X BWPM Points Type R-Value Area X WPM = Points Adjacent 0.0 0.00 0.0 Concrete, Int Insul, Exterior 5.0 2056.0 5.70 11719.2 Exterior 2056.0 3.70 7607.2 1 Base Total: 2056.0 7607.2 As-Built Total: 2056.0 11719.2 DOOR TYPES Area X BWPM Points Type Area X WPM Points Adjacent 0.0 0.00 0.0 Exterior Insulated 20.0 8.40 168.0 Exterior 20.0 12.30 246.0 Base Total: 20.0 246.0 , As-Built Total: 20.0 168.0 EnergyGauge@ DCA Form 60OA-2001 EnergyGaugeV/FlaRES'2001 FLRCPB v3.30 FORM 60OA-2001 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details Plat: FL, PERMIT#: BASE AS-BUILT 'PM Points CEILING TYPES Area x BWpM =oints Type R-Value Area X WPM x WCM Under Attic 2292.0 2.05 4698.6 Under Attic 30.0 2083.0 2.05 X 1.00 4270.1 Single Assembly 19.0 209.0 1.86 X 1.00 388.7 ointS 4217 01 Under Attic 388 7 19.0 466.0 2.70 X 1.0o 1258.2 Base Total: 2292.0 4698.6 As-Built Total: 2758.0 5917.1 FLOOR TYPES Area X BWPM Points Type - R-Value Area X WPM Points Slab 0.0(p) 0.0 0.01Raised Wood,Stem Wall 11.0- 2190.0 1.20 2628.0 Raised 2277.0 0.96 2185.9 Raised Wood, Post or Pier 11.0 87.0 1.55 134.8 Base Total: 2185.9 As-Built Total: INFILTRATION Area X BWPM Poin I ts 2277.0 2762.9 - - Area X WPM = Points 3240.0 -0.59 -1911.6 Winter Base Points: 20256.1 Winter As-Built Points: 3240.0 -0.59 -1911.6 - 31742.3 Total Winter X System Heating Total X Cap X Duct X System X Credit Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (DM x DSM x AHU) 31742.3 0.619 (1.069X1.169x0.88) 0.416 0.950 9085.91 31742.3 0.381 (1.069xl.169xl.05) 0.449 0.950 6045.3 20 E 256.1 0.6274 12708.7 31742.3 1.00 1.171 0.428 0.950 1511 0.6 EnergyGaugeTm DCA Form 60OA-2001 EnergyGaugeS/FlaRES'2001 FLRCPB v3.30 FORM 60OA-2001 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details FADDRADDRESS: Lot: , Sub: , Plat: , , FL, ESS,, Lot,, , Sub. , Plat,�, , FL�, PERMIT#: P�ER M I T�#. 13ASE WATER HEATING — mmm� AS-BUILT Number of X Multiplier Total i Tank EF Bedrooms Numberof X Tank X Multiplier X Credit Total 2746 Volume Bedrooms Ratio Multiplier 13730.0 65.0 0.91 5 1.00 2655.47 1.00 13277.4 As-Built Total: 13277.4 CODE COMPLIANCE STATUS '32774 =13277.4 BASE AS-BUILT - --- j Cooling Heating + Hot Water Total Cooling Heating + Hot Water = Total Points Points Points Points Points Points Points Points 18457 12709 13730 44895 95 16295 15111 13277==44683 EPASS j,T14E S 4v 0 fill Q0 wF EnergyGaugeTm DCA Form 60OA-2001 EnergyGauge(@/FlaRES'2001 FLRCPB v3.30 FORM 60OA-2001 �Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: Lot: , Sub: , Plat: , , FL, PERMIT#: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMEN_FOR EACH PRACTICE Exterior CHECK -M9-dOws—&DOors 606.I.ABC.1.1 Maximum:. window ama; -5 fM��.ft._dloor area CM Exterior&Adjacent Walls 606.1.ABC.1.2.1 Caulk,gasket,weatherstrip or seal between:windows/doors&frames,surrounding wall; foundation&wall sole or sill plate;joints between exterior wall panels at corners;utility penetrations;between wall panels&top/bottom plates;between walls and floor. EXCEPTION:Frame walls where a continuous infiltration barrier is installed that extends C E E 0 e e MP x, " xt no 0 0 r r N WEN i4 AdjT 0 aS c F Floors -- -from—,ar-Ld is_sealed to�the foundation to the top_plate_ loors 606.1.ABC.1.2.2 Penetrations/openings>1/8"sealed unless backed by truss or joint members. EXCEPTION:Frame floors where a continuous infiltration barrier is installed that is sealed C Ce lings eilings 606.1.ABC.1.2.3 Between walls&ceilings;penetrations of ceiling plane of top floor;around shafts,chase F soffits,chimneys,cabinets sealed to continuous air barrier;gaps in gyp board&top plates;' 60 0 6 -*11*A A i I ,]CHECK l13� sc attic access. EXCEPTION:Frame ceilings where a continuous infiltration barrier is i in-stalled that is sealed a enetrations and seams, Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no pe 0 netrations,sealed;or Type IC or non-IC rated,installed inside a- I sealed box with 1/2"clearance&3"from insulation;or Type IC rated with<2.0 cfm from -M-ulti- conditi med space,tested, _�_-Stqryh[ouses 606.I.ABC.1.2.5_____Akr barrier on perimeter of floor -P�vit �between floors. Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors,dampers;combustion space_h_______ have combustion air. eaters comply with NFPA, I OTHER PRESCRIPTIVE MEASURES (must be met or exceeded b all residences.) EQUIREM' omply with' HI eake_r�elec pas&heate COMPONENTS 7� T72 R sEcTlo SECTION— ----- REQUIREMENTS----------- C ECK Water Heaters 612.1 Comply with efficiency requirements in Table 6-12.Switch or clearly ma-__ Wa breaker(electric)or cutoff I a" rked circuit _rnust be provided. em I or -n heat trap required. Swimming Pools&Spas __bW 4 r, 612.1 Spas&heated pools must have covers(except solar heated). Non-com—me-rcial-pools- F must have a pump timer.Gas spa&pool heaters must have a minimum thermal --efficiency of-78%. Showerheads 612.1 Water flow must be restricted to no more han 6'2 Air Distribution Systems 610.1 SIG. 1 All ducts,fittings, mechanical equipment and plenum chambers shall be mechanically atta c attached,sealed, insulated,and installed in accordance with the criteria of Section 610. c Ducts in unconditioned attics:R-6 min. insulation. HVAC Controls 607.1 Sepa 0 Separate-readify access�ilemanualor automatic theLmostat for eachMstem. C 'lir Insulation 604.1. 602.1 Ceilings-Min. R-19.Common walls-Frame R-1 1 or CBS R-3 both sides. Corn r Common ceiling&floors R-1 1. EnergyGauge'll DCA Form 60OA-2001 EnergyGaugeS/FlaRES'2001 FLRCPB v3.30 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFO RMANCE SCORE* 83.6 The higher the score,the more efficient the home. New construction or existing Lot: , Sub: Plat: FL, 2. Single family or multi-family New 12. Cooling system, I Number of units,if multi-family Single family a. Central Unit 4- Number of Bedrooms I Cap:48.0 kBtu/hr 5. Is this a worst case? 5 b. Central Unit SEER: 13.50 - 6. Conditioned floor area(ft2) Yes Cap:28.4 kBtu/hr - 7- Glass area&type 3240ft2 c. N/A SEER: 12.10 - a. Clear-Single pane Single Pane Double Pane b. Clear-double pane 0.0 ft2 611.0ft2 0.0 ft2 0.0 ft2 13. Heating systems c. Tint/other SHGC-single pane 0.0 R2 0.0 ft2 - a. Electric Heat Pump d. Tint/other SHGC-double pane - Cap:48.0 kBtu/hr 8. Floor types b. Electric Heat Pump HSPF:8.20 a. Raised Wood,Stem Wall Cap:29.6 kBtu/hr b. Raised Wood,Post or Pier R�i 1.0,2190.0ft2 - c. N/A HSPF:7.60 c. N/A R=1 1.0,87.0fP 9. Wall types 14. Hot water systems a. Concrete,Int Instil,Exterior a. Electric Resistance b. N/A R=5.0,2 056.0 ft2 Cap:65.0 gallons c. N/A b. N/A EF:0.91 d. N/A e. N/A c. Conservation credits 10. Ceiling types (HR-Heat recovery,Solar a. Under Attic R=30-0,2083.0 ft2 DHP-Dedicated heat pump) b. Single Assembly R=19.0,209.0ft2 15. HVAC credits c. Under Attic IL Ducts R=19-0,466.0 W (CF-Cciling fan,CV-Cross ventilation, PT, HF-Whole house fan, a. Sup:Unc. Ret:Unc. AH(Sealed):Interior Sup-R=6-0,250.0 ft PT-PrOgrammable Thermostat, b. Sup:Unc. Ret:Unc. AH(Scaled):Attic Sup.R=6.0, 125.0 ft MZ-C-Multizone cooling, MZ-H-Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above energy saving features which will be installed(or exceeded) -,VHE Sri in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. S Builder Signature: Date: Address 4A New H ome: City/FL Zip: 0 WE *NOTE.- The home's estimated energy performance score is only available through the FLAIRES computer program. This is not a Building Energy Rating. Ifyour score is 80 or greater(or 86for a US EPAIDOE EnergyStar 7ndesignation), your home may qualifyfor energy efjiciency mortgage(EEM) incentives ifyou obtain a Florida Energy Gauge Rating. Contact the Energy Gauge flolline at 3211638-1492 or see the Ener Gauge web site a www.fsec.uc e r gy t f du fo information anda list of cerlified Raters. For information about Florida's Energy Efficiency Code For Building Cons(rucaon, contact the Department of Community Affairs at 8501487-1824. EnergyGauge(b(Versiow.FLRCPB v3.30)