Loading...
MECH PERMIT 150 Sherry Dr CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00002442 Date 4/09/13 Property Address . . . . . . 150 SHERRY DR Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 5902 ---------------------------------------------------------------------------- Application desc Replace HVAC 5 tons 56, 000 btu' s ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ COMMUNITY PRESBYTERIAN OCEAN STATE HEAT & AIR, INC. CHURCH 1476 ATLANTIC BLVD. 150 SHERRY DR NEPTUNE BEACH FL 32266 ATLANTIC BEACH FL 322335236 (904) 249-8251 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . INSTALL NEW 5TON SYSTEM Permit Fee . . . . 115 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 10/06/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 115 . 00 115 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 119 . 00 119 . 00 . 00 . 00 PERMIT,IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. -MECHANICAL PER-MIT APPLICATION CITY OF ATLANTIC BEACH 8,30 Seminole Rd Atlantic Beach. FL -31-22131 Ph (904) 247-5926 Fa.), (904) 247-5845 JOB ADDRESS: PERMfT PROJECT f�4LUE S E- NEW ,'UR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditionina: Unit Quant1tv Tons Per Unit Heat: Unit Quantin" BTU's Per Unit Duct Svstems: Total CFM Seer Ratinz j ff 0:�-U—IkED REPLACEMENT AIR CONT-DITIONING & HEATING SYSTEM INSTALLA�TION -Air Conditioning: Unit Quantity I Tons Per Unit ARI 4 .,3 19001 T Heat: Unit Quantit"A" BTUs Per Unit KE-ULTIRED Duct Systems: Total CFM --9�to 0 Seer Razing_ Q RE-0 UIR-ED FIRE PREVENTION Fire Sprinkler System Quantit�, (Requires 3 sets of plans) Fire S+andpipe Quantity (Requires3­1 sets of plans) Under-around Fire Main Value (Requires sets of plans) Fire 17rose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantil-�-- (Requires 3 sets of plans) Fire Suppression Systems uantny Q (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty— Automobile Lifts Gas PiDine Outlets Boilers Eievators,E�scalators s -ALL OTHER GAS PIPING Heai Exchan-er Quantitv of Outlets P NT, umps ented Wall Furnaces Refri�gerator Condenser BTU"s 4 V,'ater Heaters Solar Collection Systems Tanks (gallons) V7ejjS OTHER: N� P ermi-becomes void if work does not commence withir a six mo!7th period or work iss suspended 77,abapdoned for six m-onths.I hereby certif�'that,I have read this application and know the same to be true and correct. All provisions of I?-,kks and ordinances gov--r-ning this work will be complied with whether specifi-,� or not. The permit does not-orive authority to violate the provisions of any other stato or loccai law regulation construction or the performanec ofmnstruction. Properft, 0-wners--Name PhoneNumber 7Dq- (,qLZ I _Cn t4 Mechanical Company 0 d-Ne A,- Of-fice Phone 2V5-2;,j-1 Fax 2-vj- Zjy9 Co. Address: _1,1-7 U A4jjAe_ —8juj Citl State Zjj) ?t 2-1, License Holder(Print): State Certificatio , -gistration o Notarized Sign.ature of License Ho YVETTE P.MORALES S orn an d sub cf6re this da - of 20_a NOTARY PLISUC STATE OF FLORIDA Sig 1,re,of Not Public Comn-A EE$79174 v Expires 3/Ml 7 ACCA Manual "J" Heat Load Calculation Date 04/08/13 customers Name Community Presbyterian Church Location Atlantic Beach OKI g-allga I Gross Wall 77 1,503 2 W ,3 Windows I North Al, N, 2 29.0 16.0 15 435 240 East& West Al, E &W, 2 29.0 46.0 112 3,248 5,152 South— Al, S, 2 29.0 25,0 20 580 500 4 Doors Front Solid Wood - Panel 27.0 15.8 30 810 474 Patio Solid Wood-Storm 16.4 97 0 0 Other___SIdg GI Dr, S, 2 32.6 25.0 0 0 0 5 Net Wall I Area I R- 11, 1/2"Asp. l3rd. 3.2 t9 1,632 5,222 3,101 Area 2 R- 13, 1/2"Asp. Brd. 3.0 1.8 0 0 Area 3 R- 13, 1/2"Asp. Brd. 3.0 1.8 0 0 1 r6 Ceilings -- --E .8 — 1 Area I Attic, R-22 '1.9 -2q 0 0 Area 2 Attic, R- 19 2.1 2.3 0 0 Area 3 Attic, R- 19 2.1 2.3 1,503 3,156 3,457 7 Floors Area I Slab 40.5 U 167 6,764 0 Area 2 None 0.0 0.0 ET 0 0 8 Infiltration Winter Summer Avg Cilng Ht Poor 1500-2100 1.2 0.6 10 16,566 13,313 9 Sub Total BTUH Loss 36,781 10 Duct BTUH Loss 1 9,613 11 TOTAL HEATING LOAD 46, 94 12 People and Appliances Bedrooms — 7,200 13 Sub Total BTUH Gain (Structure) 14 Duct BTUH Gain gLocation Attic .........�33,437 15 TOTAL SENSIBLE 15% 6,321 39,758 16 Infiltraton Latent Gain Infit. CFM 151 12,321 17 People Latent Gain #People 8 4,800 19 TOTAL LATENT 17,121 19 Total Cooling Load 56,879 MWILd CERTIFIEDT. L www.ahridiriectory.org — 'A Certificate of Product Ratings AHRI Certified Reference Number: 3890017 Date: 4/8/2013 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 2SHBC360(A,W)**30 Indoor Unit Model Number: FB4CNF060 Manufacturer: CARRIER AIR CONDITIONING Trade/Brand name: COMFORT 13 PURON HP Manufacturer responsible for the rating of this system combination is CARRIER AIR CONDITIONING Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity(Btuh): 58000 EER Rating (Cooling): 10.80 SEER Rating(Cooling): 13.00 Heating Capacity(Btuh)@ 47 F: 56000* Region IV HSPF Rating (Heating): 7.70 Heating Capacity(Btuh)@ 17 F: 36200 Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no re resentations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for parnages of any kind arising out of the use or performance of the product(s),or the unauthorized atteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at wwvv.ahriclirectory�org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products ofAHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org, click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on it "IMF, Air-Conditioning,Heating, which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. APOU 00 ILI and Refrigeration Institute @2013 Air-Conditioning,Heating,and Refrigeration Institute CERTIFICATE NO.: 130099220955992966