Loading...
1879 Beach Ave MECH AVE k �k ,, CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00002445 Date 4/10/13 Property Address . . . . . . 1879 BEACH AVE Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 4375 ---------------------------------------------------------------------------- Application desc 5 ton system change out ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ PETRONI GERARD P & REIDUNN TRS TROPIC HEATING & AIR 1879 BEACH AVE 750 MAYPORT RD ATLANTIC BEACH FL 322335938 ATLANTIC BEACH FL 32233 (904) 241-1788 ---------------------------------------------------------------------------- Permit ' * * ' * * MECHANICAL HVAC PERMIT Additional desc . . 5 TON SYSTEM CHANGE OUT Permit Fee . . . . 115 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 10/07/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 115 . 00 115 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 119 . 00 119 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach,FL 32233 Ph(904)247-5826 Fax(904)247-5845 JOB ADDRESS: PERMITo/--6, 2X�Zj- PROJECT VALUE $ 417 -7 5"' NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity I' Tons Per Unit ARI# ??at 4D Yo Heat: Unit Quantity BTU's Per Unit REQUIRED Duct Systems: Total CFM Seer RatinL—Z-3— REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty_ Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspende-d—or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction, Property Owners Name 11e;4VA11 Phone Number Mechanical Company 7--P/7,t 14&0� T-Offil e Phone 2- .7/ -202 eax ;W fel Co. Address: �7 S16 ^4A A81-i Ad city- A -ff State j!!Mil) License Holder(Print): State Certification/Registration# A Notarized Signature of License Holder KAREN E.PANTFOEDER Sworn and sullibed'before me this– day of 40ri'l 2013 NOTARY PUBLIC Signature of Notary Publi STATE OF FLORIDA Comm#EE064448 EXPIres 3/4/2015 CERTIFIEDTM vvww.a h rid i rectory.o rg Certificate of Product Ratings AHRI Certified Reference Number: 3890040 Date: 4/9/2013 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 213BN(A,W)060****A Indoor Unit Model Number: FB4CNF060 Manufacturer: BRYANT HEATING AND COOLING SYSTEMS Trade/Brand name: LEGACY LINE PURON HP Manufacturer responsible for the rating of this system combination is BRYANT HEATING AND COOLING SYSTEMS Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity(13tuh): 58000 EER Rating (Cooling): 10.80 SEER Rating (Cooling): 13.00 Heating Capacity(Btuh)@ 47 F: 56000* Region IV HSPF Rating (Heating): 7.70 Heating Capacity(Btuh)@ 17 F: 36200 Ratings followed by an asterisk(*)Indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorso the product(s)Usted on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility W the product(s)Illsted on this Certificate.AHIRI expressly disclaims all Ilabillity for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data Usted on this Certificate.Certified ratings are valid only for models and configurations listed In the directory at www.ahridirector)4org. TERMS AND CONDITIONS This Certificate and its contents am proprietary products of AHRL This Certificate shall only be used for Individual,personal and confidentlial reference purposes. The contents or this Certificate may not,in whole or In part,be reproduced;copied;disseminated;entered Into a computer database;or otherwise utillized,In any form or manner or by any means,except for the user's Individual,personal and confidential reference. CERTIFICATE VERIFICATION The Information for the model cited an this certificate can be verified at www.ahridirectoryorg, it "101 Ai C diti ning,Heating, dick on"Verify Certificate"Unk and enter the AHRI Certified Reference Number and the date on AIIIIW No ILI ir- on I to which the certificate was issued,which Is Isted above,and the Certificate No.,which Is Usted bellow. and Refrigeration Institute 02013 Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO.: 130099887456502248 Project Summary Job: Petron! Date: 418/2013 Entire House By: Tropic Heating&Air C Tropic Heating & Air Conditioning, Inc. 750 Mayport Rd,Atlantic Beach,Fl-32233 Phone:904-241-1788 Fax:904-241-2172 Email:Tropicac@msn.com License:CA0052431 - Project Information For: Reidunn Petroni, Tropic Heating&AirConditioning,Inc. 1879 Beach Ave.,Atlantic Beach, FL 32233 Phone: 904-241-1788 Fax: 904-241-2172 Notes: Email:Tropicac@msn.com Design Information Weather: Jacksonville/Craig, FL, US Winter Design Conditions Summer Design Conditions Outside db 35 'F Outside db 91 *F Inside db 70 'F Inside db 75 'F Design TD 35 'F Design TD 16 'F Daily range M Relative humidity 50 % Moisture difference 53 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 24053 Btuh Structure 30443 Btuh Ducts 10863 Btuh Ducts 9698 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 34916 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 40141 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3212 Btuh Ducts 3028 Btuh Area(ft2) Heating Cooling Central vent(0 cfm) 0 Btuh 2800 2800 Equipment latent load 6240 Btuh Wume(M) 22400 22400 Air changes/hour 0.41 0.21 Equipment total load 46381 Btuh Equiv.AVF(cfm) 153 78 Req. total capacity at 0.70 SHR 4.8 ton Heating Equipment Summary Cooling Equipment Summary Make n/a Make Trade n/a Trade Model n/a Cond AHRI ref n/a Coil AHRI ref Efficiency n/a Efficiency 0 SEER Heating input 0 MBtuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 'F Total cooling 0 Btuh Actual air flow 1812 cfm Actual air flow 1812 cfm Air flow factor 0.052 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat Load sensible heat ratio 0.87 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft' Right-Sufte@ Universal 2012 12.1.06 Right JO Mobile 2013-Apr-08 17:08:45 ...\wetmp%a7l5375f-29db-49b3-beal-lOf96MScll.rup Calc=MU8 FrontDoorftces: W Page 1 Right JO Mobile Report Job: Petroni Date: 4/812013 ire House By: Tropic Heating&Air C... Tropic Heating &Air Conditioning, Inc. 750 Mayport Rd,Atlantic Beach,FL32233 Phone:904-241-1788 Fax:904-241-2172 Email:Tropicac@msn.com Ucense:CAC052431 Project Information For: Reidunn Petroni, Tropic Heating&AirConclitioning,Inc. 1879 Beach Ave.,Atlantic Beach, FL 32233 Phone: 904-241-1788 Fax: 904-241-2172 Email:Tropicac@msn.com Design Conditions Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature('F) 70 75 Elevation: 43 ft Design TD('F) 35 16 Latitude: 30ON Relative humidity 30 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 8.4 52.8 Dry bul b('F) 35 91 Infiltration: Dailyrange ff) - 17 ( M Method Simplified Wet bulb(o F) - 77 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 Component BIuh/fF Btuh %of load Walls 3.4 7009 20.1 V\91 Glazing 30.1 8429 24.1 Dxts Doors 13.5 425 1.2 Ceilings 1.7 2374 6.8 Floors 0 0 0 Infiltration 2.4 5817 16.7 Ducts 10863 31.1 Gaft Piping 0 0 1 Humidification 0 0 1rft&n Ventilation 0 0 Cmirgs Adjustments 0 Total 1 1 34916, 100.01 Component Btu h/ft2 Btuh %of load Walls 2.6 5450 13.6 VMWLS IribmA Gains Glazing 56.2 15748 39.2 Doors 11.4 360 0.9 Ceilings 2.6 3622 9.0 Floors 0 0 0 Ducts Infiltration 0.6 1404 3.5 Ducts 9698 24.2 Ventilation 0 0 Internal gains 3860 9.6 Gaging Blower 0 0 Infiltration Adjustments 0 ceilrimm Total 1 1 40141 , 100.01 aher Latent Cooling Load=6240 Btuh Overall U-\ralue=0.101 Btuh/ft2-*F Data entries checked. 2013-Apr-08 17:08:45 wrightSOft Right-SulteO Universal 2012 12.1.06 Right A)Mobile Page 1 ...\wetmp\a7l5375f-29db-49b3-beal-lOf96D8Q6cll.rup Calc=MJ8 FrontDoorfaces: W Right-JO WorkshW Job: Petroni Entire House Date: 4/812013 Tropic Heating &Air Conditioning, Inc. By: Tropic Heating&Air Condi 750 Mayport Rd,Atlantic Beach,Fl.32233 Phone:904-241-1788 Fax:904-241-2172 Email:Troplcac@msn.com License:CAC052431 1 Room name Entire House Second Floor 2 Exposed wall 300.0 ft 150,0 ft 3 Room height 8.0 ft d 8.0 ft heat(cool 4 Room dimensions 35.0 x 40.0 ft 5 Room area 2WO.0 ft2 14W.0 ft2 TY Construction U-value. Or (BtHTM Area (W) Load Area (ft2) Load number (Btuh/W� F) Uh/ft2 or perimeter (ft (Stuh) or perimeter (ft) (Btuh) i Heat I Cool j Gro. I N/P/S Heat Cool P/S j Heat I Cool 6 V" 128-Osw 0.097 n 3.36 2.61 560 495 1661 1292 280 248 831 646 I D-c2om 0.870 n 30.10 28,08 65 0 1957 1825 33 0 978 913 12B-Osw 0.097 e 3.36 2.61 640 565 1896 1474 320 283 w 737 t---G ID-c2om 0.870 a 30.10 78.45 75 0 2258 5884 38 0 1129 2942 11 I= 12B-0sw 0.097 s 3.36 2.61 560 464 1556 1209 280 216 725 564 1 D-c2om 0.870 s 30.10 33.16 65 0 1957 2156 33 0 978 1078 11DO 0.390 a 13.49 11.43 32 32 425 360 32 32 425 360 12B-Osw 0.097 w 3.36 261 640 565 1896 1474 320 283 948 737 t--.G 1D-c2om 0.870 w 30.10 78.45 75 0 2258 5884 38 0 1129 2942 C 16B-19ad 0.049 1.70 2.59 1400 1400 2374 3622 0 0 0 0 F Florl 0.000 0.00 0.00 1400 1400 0 0 1400 1400 0 0 1 61 c)AED excursion 01 1 1 Envelope lose/gain 1 182371 251801 1 1 809 12 a) Infiltration 5817 1404 2908 702 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants C 230 2 460 2 460 Appliances/other 3400 3400 Subtotal(lines 6 to 13) 24053 30443 11000 15480 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 24053 30443 11000 15480 15 Duct loade 45% 32% 10863 9698 45% 32% 4968 4931 Total room I ad 349161 401411 1 1 159671 204101 Air requiredloc") 1812 1812 828 921 Calculations aporoved by ACCA to meet all requirements of Manual J 8th Ed. 2013-Apr-08 17:08:45 Aftil -411- wrights4:*ft Right-Suiteg Universal 2012 12.1.06 Right J(&Mobile Page 1 ...\wstmp\a7l5375f-29db-49b3-beal-lOf96O8O6c1 I.rup Calc=MJ8 Front Door faces: W Right-M Worksheet Job: Petroni Date: 4/8/2013 am, Etitire House By: Tropic Heating&Air Condi Tropic Heating &Air Conditioning, Inc. 750 Mayport Rd,Atlantic Beach,FL 32233 Phone:904-241-1788 Fax:904-241-2172 Email:Tmpleac@,fTm.com License:CAC052431 I Room name Third Floor 2 Exposed wall 150.0 ft 3 Room height 8.0 It heat/cool 4 Room dimensions 35.0 x 40.0 It 5 Room area 1400.0 ft2 Ty Construction lue HTM Area (ft2) Load Area Load number L(BUXW�.'F)j Or (Btutvft2) or perimeter (ft) (Btuh) or penmeter Heat Cool Gross N/P/S Heat Cool Gross NIP/S Heat cool 6 %f 128-OBW 0.097 n 3.36 2 61 280 248 831 646 I Dc2om 0.870 n 30.10 28.08 33 0 978 913 V" 12B-Osw 0.097 e 3.36 2.61 320 283 948 737 1 D-c2om 0.870 e 30.10 78.45 38 0 1129 2942 280 248 831 646 Y 12B-Osw 0,097 a 3.36 2.61 1 D-c2 m 0.870 a 30.10 33.16 33 0 978 1078 11DOO 0.390 a 13.49 11.43 0 0 0 0 12B-0sw 0.097 w 3.36 2.61 320 283 948 737 t--G 1 D-c2om 0.870 w 30.10 78.45 36 0 1129 2942 C 16B-19ad 0.049 1.70 2.59 1400 1400 2374 3622 F Florl 0.000 0.00 0.00 0 0 0 0 i6i c)AED excursion 01 1 Envelope lossigain 101451 142b2 12 Infiltration 2908 702 b) Room ventilation 0 0 13 Internal gains: Occupants Q 230 0 0 Appliances/other 0 Subtotal(lines 6 to 13) 13054, 14964 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 13054 14964 15 Duct loads 45% 32% 5895 4767 Total room load 18M 1 197311 Nr required(cfm) 983 890 1 1 Calculations awroved by ACCA to meet all reouirements of Manual J 8th Ed. 2013-Apr-08 17:08:45 -401- wrightscxft Right-Sulteg Universal 2012 12.1.06 Right JS Mobile Page 2 Aft#, ...\wstmp\a715375f-29db-49b3-bea1-1 OWD806cl l.rup Calc=W8 Front Door faces: W Component Constructions Job: Petroni Date: 418/2013 Entire House By: Tropic Heating&Air C... N Tropic Heating & Air Conditioning, Inc. 750 Mayport Rd,Atlantic Beach,FL 32233 Phone;904-241-1788 Fax:904-241-2172 Email:Tropicac@msn.com Ucense:CAC052431 Project Information For: Reidunn Petroni, Tropic Heating&AirConditioning,Inc. 1879 Beach Ave.,Atlantic Beach, FL 32233 Phone: 904-241-1788 Fax: 904-241-2172 Email:Tropicac@msn.com Design Conditions Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature(OF) 70 75 Elevation: 43 ft Design TD(OF) 35 16 Latitude: 30'N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 8.4 52.8 Dry bulb(OF) 35 91 Infiltration: Dailyrange(OF) - 17 M Method Simplified Wet bulb(OF) - 77 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft2 BtuhV-'F f?-'F/Bklh BtuhAP Btuh BtuhM Btuh Walls 12B-Osw:Frm wall,vnl ext, r-1 I cav ins, 1/2"gypsum board int n 495 0,097 11.0 3.36 1661 2.61 1292 fnsh,2"x4'wood frm e 565 0.097 11.0 3.36 1896 2.61 1474 s 464 0.097 11.0 3.36 1556 2.61 1209 W 565 0.097 11.0 3.36 1896 2.61 1474 all 2089 0.097 11.0 3.36 7009 2.61 5450 Partitions (none) Windows 1D-c2om:2 glazing,or outr,air gas,mtl no brk frm mat,dr innr, 1/4" n 65 0.870 0 30.1 1957 28.1 1825 gap, 1/8"thk e 75 0.870 0 30.1 2258 78.4 5884 s 65 0.870 0 30.1 1957 33.2 2156 W 75 0.870 0 30.1 2258 78.4 5884 all 280 0.870 0 30.1 8429 56.2 15748 Doors 11 DO:Door,wd so type s 32 0,390 0 13.5 425 11.4 360 Ceilings 16B-19ad:Attic oeiling, asphalt shingles roof mat,r-19 ceil ins, 1/2' 1400 0.049 19.0 1.70 2374 2.59 3622 gypsum board int frish Floors Florl:Florl 1400 0 0 0 0 0 0 2013-Apr-08 17:08:45 wrightsoft Right-s.itee Universal 2012 12A�06 Right JS Mobile Page 1 ACCX ...\wstmpla7l5375f-29db-49b3-beal-lOf960806cil.rup Calc=MJ8 FrontDoorfaces: W AED Assessment Job: Petroni Date: 418/2013 Entire House By: Tropic Heating&Air C Tropic Heating &Air Conditioning, Inc. 750 Mayport Rd,Atlantic Beach,FL 32233 Phone:904-241-1788 Fax:904-241-2172 Email:Tropirac@msn.com Ucense:CAC052431 Project Information For: Reidunn Petroni, Tropic Heating&AirConditioning,Inc. 1879 Beach Ave.,Atlantic Beach, FL 32233 Phone: 904-241-1788 Fax: 904-241-2172 Email:Tropicac@msn.com Design Conditions Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature(*F) 70 75 Elevation: 43 ft Design TD('F) 35 16 Latitude: 30'N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 8.4 52.8 Dry bulb(*F) 35 91 Infiltration: Dailyrange('F) - 17 M Wet bulb('F) - 77 Wind speed(mph) 15.0 7.5 Test for Adequate Exposure Diversity Hourly Glazing Load 20,OOE------- -- ------ - 18,00(- 16,00(- 14,00(- 10,00(- 8,00(- 6,00(- 4,00(- 2,00(1- 8 10 1 1 1 2 13 1 4 1 5 16 1 7 1 8 1 9 2 0 Hour of Day X FbAy Z Aerage AEDlinit Maximum hourly glazing load exceeds average by 19.6%. House has adequate exposure diversity (AIED), based on AED limit of 30%. AIED excursion: 0 Btuh 2013-Apr-08 17:08:45 wrightsoft Right-SuiteO Universal 2012 12.1.06 Right AD Mobile Page 1 '111M ...\wstmp\a7l5375f-29db-49b3-beal-lOf960806c1 I.rup Cale=MJ8 Front Door faces: W