1879 Beach Ave MECH AVE k �k ,,
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 13-00002445 Date 4/10/13
Property Address . . . . . . 1879 BEACH AVE
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 4375
----------------------------------------------------------------------------
Application desc
5 ton system change out
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
PETRONI GERARD P & REIDUNN TRS TROPIC HEATING & AIR
1879 BEACH AVE 750 MAYPORT RD
ATLANTIC BEACH FL 322335938 ATLANTIC BEACH FL 32233
(904) 241-1788
----------------------------------------------------------------------------
Permit ' * * ' * * MECHANICAL HVAC PERMIT
Additional desc . . 5 TON SYSTEM CHANGE OUT
Permit Fee . . . . 115 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 10/07/13
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 115 . 00 115 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 119 . 00 119 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach,FL 32233
Ph(904)247-5826 Fax(904)247-5845
JOB ADDRESS: PERMITo/--6, 2X�Zj-
PROJECT VALUE $ 417 -7 5"'
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity I' Tons Per Unit ARI# ??at 4D Yo
Heat: Unit Quantity BTU's Per Unit REQUIRED
Duct Systems: Total CFM Seer RatinL—Z-3—
REQUIRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty_ Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
# Vented Wall Furnaces Refrigerator Condenser BTU's
# Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER:
Permit becomes void if work does not commence within a six month period or work is suspende-d—or abandoned for six months.I hereby certify that I have read
this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified
or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction,
Property Owners Name 11e;4VA11 Phone Number
Mechanical Company 7--P/7,t 14&0� T-Offil e Phone 2- .7/ -202
eax ;W
fel
Co. Address: �7 S16 ^4A A81-i Ad city- A -ff State j!!Mil)
License Holder(Print):
State Certification/Registration# A
Notarized Signature of License Holder
KAREN E.PANTFOEDER Sworn and sullibed'before me this– day of 40ri'l 2013
NOTARY PUBLIC Signature of Notary Publi
STATE OF FLORIDA
Comm#EE064448
EXPIres 3/4/2015
CERTIFIEDTM
vvww.a h rid i rectory.o rg
Certificate of Product Ratings
AHRI Certified Reference Number: 3890040 Date: 4/9/2013
Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source
Outdoor Unit Model Number: 213BN(A,W)060****A
Indoor Unit Model Number: FB4CNF060
Manufacturer: BRYANT HEATING AND COOLING SYSTEMS
Trade/Brand name: LEGACY LINE PURON HP
Manufacturer responsible for the rating of this system combination is BRYANT HEATING AND COOLING
SYSTEMS
Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third
party testing:
Cooling Capacity(13tuh): 58000
EER Rating (Cooling): 10.80
SEER Rating (Cooling): 13.00
Heating Capacity(Btuh)@ 47 F: 56000*
Region IV HSPF Rating (Heating): 7.70
Heating Capacity(Btuh)@ 17 F: 36200
Ratings followed by an asterisk(*)Indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate.
DISCLAIMER
AHRI does not endorso the product(s)Usted on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility W
the product(s)Illsted on this Certificate.AHIRI expressly disclaims all Ilabillity for damages of any kind arising out of the use or performance of the product(s),or the
unauthorized alteration of data Usted on this Certificate.Certified ratings are valid only for models and configurations listed In the directory at www.ahridirector)4org.
TERMS AND CONDITIONS
This Certificate and its contents am proprietary products of AHRL This Certificate shall only be used for Individual,personal and confidentlial reference purposes.
The contents or this Certificate may not,in whole or In part,be reproduced;copied;disseminated;entered Into a computer database;or otherwise utillized,In any
form or manner or by any means,except for the user's Individual,personal and confidential reference.
CERTIFICATE VERIFICATION
The Information for the model cited an this certificate can be verified at www.ahridirectoryorg, it "101 Ai C diti ning,Heating,
dick on"Verify Certificate"Unk and enter the AHRI Certified Reference Number and the date on AIIIIW No ILI ir- on I to
which the certificate was issued,which Is Isted above,and the Certificate No.,which Is Usted bellow. and Refrigeration Institute
02013 Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO.: 130099887456502248
Project Summary Job: Petron!
Date: 418/2013
Entire House By: Tropic Heating&Air C
Tropic Heating & Air Conditioning, Inc.
750 Mayport Rd,Atlantic Beach,Fl-32233 Phone:904-241-1788 Fax:904-241-2172 Email:Tropicac@msn.com License:CA0052431
- Project Information
For: Reidunn Petroni, Tropic Heating&AirConditioning,Inc.
1879 Beach Ave.,Atlantic Beach, FL 32233
Phone: 904-241-1788 Fax: 904-241-2172
Notes: Email:Tropicac@msn.com
Design Information
Weather: Jacksonville/Craig, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 35 'F Outside db 91 *F
Inside db 70 'F Inside db 75 'F
Design TD 35 'F Design TD 16 'F
Daily range M
Relative humidity 50 %
Moisture difference 53 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 24053 Btuh Structure 30443 Btuh
Ducts 10863 Btuh Ducts 9698 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 34916 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 40141 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 3212 Btuh
Ducts 3028 Btuh
Area(ft2) Heating Cooling Central vent(0 cfm) 0 Btuh
2800 2800 Equipment latent load 6240 Btuh
Wume(M) 22400 22400
Air changes/hour 0.41 0.21 Equipment total load 46381 Btuh
Equiv.AVF(cfm) 153 78 Req. total capacity at 0.70 SHR 4.8 ton
Heating Equipment Summary Cooling Equipment Summary
Make n/a Make
Trade n/a Trade
Model n/a Cond
AHRI ref n/a Coil
AHRI ref
Efficiency n/a Efficiency 0 SEER
Heating input 0 MBtuh Sensible cooling 0 Btuh
Heating output 0 Btuh Latent cooling 0 Btuh
Temperature rise 0 'F Total cooling 0 Btuh
Actual air flow 1812 cfm Actual air flow 1812 cfm
Air flow factor 0.052 cfm/Btuh Air flow factor 0.045 cfm/Btuh
Static pressure 0 in H20 Static pressure 0 in H20
Space thermostat Load sensible heat ratio 0.87
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wrightsoft' Right-Sufte@ Universal 2012 12.1.06 Right JO Mobile 2013-Apr-08 17:08:45
...\wetmp%a7l5375f-29db-49b3-beal-lOf96MScll.rup Calc=MU8 FrontDoorftces: W Page 1
Right JO Mobile Report Job: Petroni
Date: 4/812013
ire House By: Tropic Heating&Air C...
Tropic Heating &Air Conditioning, Inc.
750 Mayport Rd,Atlantic Beach,FL32233 Phone:904-241-1788 Fax:904-241-2172 Email:Tropicac@msn.com Ucense:CAC052431
Project Information
For: Reidunn Petroni, Tropic Heating&AirConclitioning,Inc.
1879 Beach Ave.,Atlantic Beach, FL 32233
Phone: 904-241-1788 Fax: 904-241-2172
Email:Tropicac@msn.com
Design Conditions
Location: Indoor: Heating Cooling
Jacksonville/Craig, FL, US Indoor temperature('F) 70 75
Elevation: 43 ft Design TD('F) 35 16
Latitude: 30ON Relative humidity 30 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 8.4 52.8
Dry bul b('F) 35 91 Infiltration:
Dailyrange ff) - 17 ( M Method Simplified
Wet bulb(o F) - 77 Construction quality Average
Wind speed(mph) 15.0 7.5 Fireplaces 0
Component BIuh/fF Btuh %of load
Walls 3.4 7009 20.1 V\91
Glazing 30.1 8429 24.1 Dxts
Doors 13.5 425 1.2
Ceilings 1.7 2374 6.8
Floors 0 0 0
Infiltration 2.4 5817 16.7
Ducts 10863 31.1 Gaft
Piping 0 0
1
Humidification 0 0 1rft&n
Ventilation 0 0 Cmirgs
Adjustments 0
Total 1 1 34916, 100.01
Component Btu h/ft2 Btuh %of load
Walls 2.6 5450 13.6 VMWLS IribmA Gains
Glazing 56.2 15748 39.2
Doors 11.4 360 0.9
Ceilings 2.6 3622 9.0
Floors 0 0 0 Ducts
Infiltration 0.6 1404 3.5
Ducts 9698 24.2
Ventilation 0 0
Internal gains 3860 9.6 Gaging
Blower 0 0 Infiltration
Adjustments 0 ceilrimm
Total 1 1 40141 , 100.01 aher
Latent Cooling Load=6240 Btuh
Overall U-\ralue=0.101 Btuh/ft2-*F
Data entries checked.
2013-Apr-08 17:08:45
wrightSOft Right-SulteO Universal 2012 12.1.06 Right A)Mobile Page 1
...\wetmp\a7l5375f-29db-49b3-beal-lOf96D8Q6cll.rup Calc=MJ8 FrontDoorfaces: W
Right-JO WorkshW Job: Petroni
Entire House Date: 4/812013
Tropic Heating &Air Conditioning, Inc. By: Tropic Heating&Air Condi
750 Mayport Rd,Atlantic Beach,Fl.32233 Phone:904-241-1788 Fax:904-241-2172 Email:Troplcac@msn.com License:CAC052431
1 Room name Entire House Second Floor
2 Exposed wall 300.0 ft 150,0 ft
3 Room height 8.0 ft d 8.0 ft heat(cool
4 Room dimensions 35.0 x 40.0 ft
5 Room area 2WO.0 ft2 14W.0 ft2
TY Construction U-value. Or (BtHTM Area (W) Load Area (ft2) Load
number (Btuh/W� F) Uh/ft2 or perimeter (ft (Stuh) or perimeter (ft) (Btuh)
i Heat I Cool j Gro. I N/P/S Heat Cool P/S j Heat I Cool
6 V" 128-Osw 0.097 n 3.36 2.61 560 495 1661 1292 280 248 831 646
I D-c2om 0.870 n 30.10 28,08 65 0 1957 1825 33 0 978 913
12B-Osw 0.097 e 3.36 2.61 640 565 1896 1474 320 283 w 737
t---G ID-c2om 0.870 a 30.10 78.45 75 0 2258 5884 38 0 1129 2942
11 I= 12B-0sw 0.097 s 3.36 2.61 560 464 1556 1209 280 216 725 564
1 D-c2om 0.870 s 30.10 33.16 65 0 1957 2156 33 0 978 1078
11DO 0.390 a 13.49 11.43 32 32 425 360 32 32 425 360
12B-Osw 0.097 w 3.36 261 640 565 1896 1474 320 283 948 737
t--.G 1D-c2om 0.870 w 30.10 78.45 75 0 2258 5884 38 0 1129 2942
C 16B-19ad 0.049 1.70 2.59 1400 1400 2374 3622 0 0 0 0
F Florl 0.000 0.00 0.00 1400 1400 0 0 1400 1400 0 0
1 61 c)AED excursion 01 1 1
Envelope lose/gain 1 182371 251801 1 1 809
12 a) Infiltration 5817 1404 2908 702
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants C 230 2 460 2 460
Appliances/other 3400 3400
Subtotal(lines 6 to 13) 24053 30443 11000 15480
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 24053 30443 11000 15480
15 Duct loade 45% 32% 10863 9698 45% 32% 4968 4931
Total room I ad 349161 401411 1 1 159671 204101
Air requiredloc") 1812 1812 828 921
Calculations aporoved by ACCA to meet all requirements of Manual J 8th Ed.
2013-Apr-08 17:08:45
Aftil -411- wrights4:*ft Right-Suiteg Universal 2012 12.1.06 Right J(&Mobile Page 1
...\wstmp\a7l5375f-29db-49b3-beal-lOf96O8O6c1 I.rup Calc=MJ8 Front Door faces: W
Right-M Worksheet Job: Petroni
Date: 4/8/2013
am, Etitire House By: Tropic Heating&Air Condi
Tropic Heating &Air Conditioning, Inc.
750 Mayport Rd,Atlantic Beach,FL 32233 Phone:904-241-1788 Fax:904-241-2172 Email:Tmpleac@,fTm.com License:CAC052431
I Room name Third Floor
2 Exposed wall 150.0 ft
3 Room height 8.0 It heat/cool
4 Room dimensions 35.0 x 40.0 It
5 Room area 1400.0 ft2
Ty Construction lue HTM Area (ft2) Load Area Load
number L(BUXW�.'F)j Or (Btutvft2) or perimeter (ft) (Btuh) or penmeter
Heat Cool Gross N/P/S Heat Cool Gross NIP/S Heat cool
6 %f 128-OBW 0.097 n 3.36 2 61 280 248 831 646
I Dc2om 0.870 n 30.10 28.08 33 0 978 913
V" 12B-Osw 0.097 e 3.36 2.61 320 283 948 737
1 D-c2om 0.870 e 30.10 78.45 38 0 1129 2942
280 248 831 646
Y 12B-Osw 0,097 a 3.36 2.61
1 D-c2 m 0.870 a 30.10 33.16 33 0 978 1078
11DOO 0.390 a 13.49 11.43 0 0 0 0
12B-0sw 0.097 w 3.36 2.61 320 283 948 737
t--G 1 D-c2om 0.870 w 30.10 78.45 36 0 1129 2942
C 16B-19ad 0.049 1.70 2.59 1400 1400 2374 3622
F Florl 0.000 0.00 0.00 0 0 0 0
i6i c)AED excursion 01 1
Envelope lossigain 101451 142b2
12 Infiltration 2908 702
b) Room ventilation 0 0
13 Internal gains: Occupants Q 230 0 0
Appliances/other 0
Subtotal(lines 6 to 13) 13054, 14964
Less external load 0 0
Less transfer 0 0
Redistribution 0 0
14 Subtotal 13054 14964
15 Duct loads 45% 32% 5895 4767
Total room load 18M 1 197311
Nr required(cfm) 983 890 1 1
Calculations awroved by ACCA to meet all reouirements of Manual J 8th Ed.
2013-Apr-08 17:08:45
-401- wrightscxft Right-Sulteg Universal 2012 12.1.06 Right JS Mobile Page 2
Aft#, ...\wstmp\a715375f-29db-49b3-bea1-1 OWD806cl l.rup Calc=W8 Front Door faces: W
Component Constructions Job: Petroni
Date: 418/2013
Entire House By: Tropic Heating&Air C...
N Tropic Heating & Air Conditioning, Inc.
750 Mayport Rd,Atlantic Beach,FL 32233 Phone;904-241-1788 Fax:904-241-2172 Email:Tropicac@msn.com Ucense:CAC052431
Project Information
For: Reidunn Petroni, Tropic Heating&AirConditioning,Inc.
1879 Beach Ave.,Atlantic Beach, FL 32233
Phone: 904-241-1788 Fax: 904-241-2172
Email:Tropicac@msn.com
Design Conditions
Location: Indoor: Heating Cooling
Jacksonville/Craig, FL, US Indoor temperature(OF) 70 75
Elevation: 43 ft Design TD(OF) 35 16
Latitude: 30'N Relative humidity(%) 30 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 8.4 52.8
Dry bulb(OF) 35 91 Infiltration:
Dailyrange(OF) - 17 M Method Simplified
Wet bulb(OF) - 77 Construction quality Average
Wind speed(mph) 15.0 7.5 Fireplaces 0
Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain
ft2 BtuhV-'F f?-'F/Bklh BtuhAP Btuh BtuhM Btuh
Walls
12B-Osw:Frm wall,vnl ext, r-1 I cav ins, 1/2"gypsum board int n 495 0,097 11.0 3.36 1661 2.61 1292
fnsh,2"x4'wood frm e 565 0.097 11.0 3.36 1896 2.61 1474
s 464 0.097 11.0 3.36 1556 2.61 1209
W 565 0.097 11.0 3.36 1896 2.61 1474
all 2089 0.097 11.0 3.36 7009 2.61 5450
Partitions
(none)
Windows
1D-c2om:2 glazing,or outr,air gas,mtl no brk frm mat,dr innr, 1/4" n 65 0.870 0 30.1 1957 28.1 1825
gap, 1/8"thk e 75 0.870 0 30.1 2258 78.4 5884
s 65 0.870 0 30.1 1957 33.2 2156
W 75 0.870 0 30.1 2258 78.4 5884
all 280 0.870 0 30.1 8429 56.2 15748
Doors
11 DO:Door,wd so type s 32 0,390 0 13.5 425 11.4 360
Ceilings
16B-19ad:Attic oeiling, asphalt shingles roof mat,r-19 ceil ins, 1/2' 1400 0.049 19.0 1.70 2374 2.59 3622
gypsum board int frish
Floors
Florl:Florl 1400 0 0 0 0 0 0
2013-Apr-08 17:08:45
wrightsoft Right-s.itee Universal 2012 12A�06 Right JS Mobile Page 1
ACCX ...\wstmpla7l5375f-29db-49b3-beal-lOf960806cil.rup Calc=MJ8 FrontDoorfaces: W
AED Assessment Job: Petroni
Date: 418/2013
Entire House By: Tropic Heating&Air C
Tropic Heating &Air Conditioning, Inc.
750 Mayport Rd,Atlantic Beach,FL 32233 Phone:904-241-1788 Fax:904-241-2172 Email:Tropirac@msn.com Ucense:CAC052431
Project Information
For: Reidunn Petroni, Tropic Heating&AirConditioning,Inc.
1879 Beach Ave.,Atlantic Beach, FL 32233
Phone: 904-241-1788 Fax: 904-241-2172
Email:Tropicac@msn.com
Design Conditions
Location: Indoor: Heating Cooling
Jacksonville/Craig, FL, US Indoor temperature(*F) 70 75
Elevation: 43 ft Design TD('F) 35 16
Latitude: 30'N Relative humidity(%) 30 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 8.4 52.8
Dry bulb(*F) 35 91 Infiltration:
Dailyrange('F) - 17 M
Wet bulb('F) - 77
Wind speed(mph) 15.0 7.5
Test for Adequate Exposure Diversity
Hourly Glazing Load
20,OOE------- -- ------ -
18,00(-
16,00(-
14,00(-
10,00(-
8,00(-
6,00(-
4,00(-
2,00(1-
8 10 1 1 1 2 13 1 4 1 5 16 1 7 1 8 1 9 2 0
Hour of Day
X FbAy Z Aerage AEDlinit
Maximum hourly glazing load exceeds average by 19.6%.
House has adequate exposure diversity (AIED), based on AED limit of 30%.
AIED excursion: 0 Btuh
2013-Apr-08 17:08:45
wrightsoft Right-SuiteO Universal 2012 12.1.06 Right AD Mobile Page 1
'111M ...\wstmp\a7l5375f-29db-49b3-beal-lOf960806c1 I.rup Cale=MJ8 Front Door faces: W