Loading...
185 8Th St 2013 HVAC .5z I CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00002480 Date 4/16/13 Property Address . . . . . . 185 8TH ST Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ ATLANTIC INVESTMENTS LLC AIR MCCALL INC 3948 3RD ST S SUITE 332 5771 MINING TER JACKSONVILLE BEACH FL 32250 STE 203 JACKSONVILLE FL 32257 (904) 288-6110 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 99 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 10/13/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 99 . 00 99 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 103 . 00 103 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax (904) 247-5845 JOB ADDRESS: 185 8 TH ST PERMIT# PROJECT VALUE $ 00 NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Ratin Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION ARI#5725542 Air Conditioning: Unit Quantity I Tons Per Unit 3 REQUIRED Heat: Unit Quantity I BTU's Per Unit I Okw Seer Rating 13 Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: replace 3 ton heat pump system with Lennox 13hpx-036, cbx25uh-036, lOkw, Honeywell pro 6000 programmable thermostat Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name Mike Curran Phone Number 904-910-6431 Mechanical Company Air McCall Office Phone 288-6110—Fax 288-6619 Co. Address: 6662 Columbia Park Dr S City Jacksonville State FL Zip 32258 License Holder(Print): JonathanMcCann __7<"? - __SWe ication/Registration# CMC 1249941 4 Notarized S old L Jj MYRTICE A L RAS S 4crib�befbre meAii� pril 20 13 My COMMISSION D916875 S o an sub r Fjordallots fv'McOm S Ea e osfuNotary Public EXPIRES September 21,2013 /aj (40T)j4�-0153 S ature of Notary Public Job: wrightsoft Right J@ Mobile Report Date: 4/16/2013 Entire House By: Robert Battinelli Air McCall Inc. 5771 Mining Ter.,#102,Jacksonville,FL 32257 Phone:904-288-6110 Fax 904-288-6619 Email:airmccall@bellsouth.netWeb:www.airmccall.com License:CMC1249941 Project Information For: Mike Curran, Atlantic investments 185 8th St., Atlantic Beach, FL 32233 Design Conditions Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature ('F) 70 75 Elevation: 43 ft Design TD ('F) 35 16 Latitude: 30'N Relative humidity 30 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 8.4 52.8 Dry bulb ('F) 35 91 Infiltration: Da i ly ra nge ('F) - 17 ( M Method Simplified Wet bu I b('F) - 77 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Component Btu h/ft' Btuh % of load Walls 7.0 11157 32.5 Glazing 19.7 3550 10.3 Doors 13.5 425 1.2 VAI Ceilings 2.8 5535 16.1 Floors 4.8 9397 27.4 Accrs Infiltration 2.4 4278 12.5 Ducts 0 0 Piping 0 0 &gl Humidification 0 0 Cd-ff CEflirgs Ventilation 0 0 Adjustments 0 Total 34343 100.0 Component Btu h/ft' Btuh %of load Walls 4.1 6514 27.0 1 rteT-d Gdr-s Glazing 41.2 7411 30.8 11 iltr2tion Doors 11.4 360 1.5 \ANI Ceilings 3.5 6847 28.4 Floors 0 0 0 Infiltration 0.6 1061 4.4 Ceilincp Ducts 0 0 Ventilation 0 0 Internal gains 1890 7.8 Blower 0 0 Adjustments 0 100.0 Gad nmg aher Total 240821 Latent Cooling Load 2725 Btuh Overall U-\ra lue =0.151 Btuh/ft2-'F Data entries checked. 2013-Apr-1 6 04:05:21 ,i;;.- + wrightsoft Right-SuiteO Universal 2012 12.1.06 Right Ja Mobile Page 1 .Z-5' -\wstmp\658ccf47-48c0-41 b2-b0f2-dbfce8f71b1b70.rup Calc=MJ8 Front Door faces: N Project Summary Job: wrightsofIr Date: 4/16/2013 Entire House By: Robert Battinelli Air McCall Inc. 5771 Mining Ter.,#102,Jacksonville,FL 32257 Phone 904-288-6110 Fax 904-288-6619 Email:airmccall@bellsouth.net Web www.airmccall.com License CMC1249941 Project Information For: Mike Curran, Atlantic investments 185 8th St., Atlantic Beach, FL 32233 Notes: ——----------- Design Information Weather: Jacksonville/Craig, FL, US Winter Design Conditions Summer Design Conditions Outside db 35 'F Outside db 91 'F Inside db 70 'F Inside db 75 'F Design TD 35 'F Design TD 16 'F Daily range M Relative humidity 50 % Moisture difference 53 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 34343 Btuh Structure 24082 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 34343 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 24082 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2725 Btuh Ducts 0 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft� 1975 1975 Equipment latent load 2725 Btuh Volume (ft) 17775 17775 Air changes/hour 0.38 0.20 Equipment total load 26807 Btuh Equiv. AVF (cfm) 113 59 Req. total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Make Lennox Trade Trade Merit Model Cond 13HPX-036 AHRI ref Coil CBX25UH-036 AHRI ref 5725542 Efficiency 0 AFUE Efficiency 13 SEER Heating input 0 MBtuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 'F Total cooling 0 Btuh Actual air flow 1096 cfm Actual air flow 1096 cfm Air flow factor 0.032 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat Load sensible heat ratio 0.90 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft Right-SuiteG universal 2012 12.1.06 Right J@ Mobile 2013-Apr-16 04 05 21 -Tr, Page I \wstmp\658ccf47-48CO-4lb2-bOf2-dbfce8f7bb7O.rup Calc=MJ8 FrontDoorfaces: N wrightsoft Right-JO Worksheet Job: Entire House Date: 4/1612013 By: Robert Battinelli Air McCall Inc. 5771 Mining Ter.,#102,Jacksonville,FIL 32257 Phone 904-288-6110 Fax�904-288-6619 Email:airmccall@bellsouth.net Web:www.airmcrall.com License:CMC1249941 1 Room name Entire House First Floor 2 Exposed wall 200�O ft 200.0 ft 3 Room height 9.0 ft d 9.0 ft heat/cool 4 Room dimensions 1.0 x 1975�O ft 5 Room area 1975.0 ft2 1975.0 ft2 I I I I I Ty Construction U-value Or HTM Are fv) Load Area (w) Load number (Btuh/ft2_'F) (Bt u h/f t2) or aperinreter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool G,.rs N/P/S Heat Cool Gross N/P/S Heat Cool 6 V" 114F-2 0.203 n 7.02 4,10 495 446 3131 1828 495 446 3131 1828 D-c2ow 0.570 n 19.72 20�91 49 0 970 1028 49 0 970 1028 14F-2 0.203 e 7�02 4L10 405 364 2558 1493 405 364 2558 1493 I D-c2ow 0.570 e 1972 6301 41 0 805 2573 41 0 805 2573 11 114F-2 0.203 s 7.02 4.10 495 446 3131 1828 495 446 3131 1828 D-c2ow 0570 s 19.72 25.16 49 0 970 1237 49 0 970 1237 J:�� 4F-2 0.203 w 7.02 4.10 405 333 2337 1364 405 333 2337 1364 G 1 D-c2ow 0570 w 19.72 63.01 41 0 805 2573 41 0 805 2573 D 1 1DO 0.390 w 1149 11.43 32 32 425 360 32 32 425 360 C 16C-1 lal 0081 280 347 1975 1975 5535 6847 1975 1975 5535 6847 F 22A-coh 1�358 46.99 0,00 1975 200 9397 0 1975 200 9397 0 61 c)AED excur ion 01 1 0 1 Envelope loss/gain 300651 21131 1 30065 211�31 12 a) Infiltration 4278 1061 4278 1061 1 b) Room ventilation 0 0 0 0 13 Internal gaii s Occupants @ 230 3 690 3 690 Appliances/other 1200 1200 Subtotal(lines 6 to 13) 34343 24082 34343 24082 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 34343 24082 34343 24082 15 Duct loads 0% 0% 0 0 _0% 0% 0 0 Total room load 343431 240821 343431 24082 1 Air required(cfm) 10961 10961 10961 10961 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-Apr-16 04:05:21 Right-Suite&Universal 2012 121.06 Right J10 Mobile Page 1 \wstmp\658ccf47-48cO-41 b2-bGf2-dbfce8f­7bb70.rup Calc=MJ18 Front Door faces: IN Job: Component Constructions Date: 411612013 wirightsoft Entire House By: Robert Battineiii Air McCall Inc. 5771 Mining Ter.,#102,Jacksonville,FL 32257 Phone:904-288-6110 Fax:904-288-6619 Email:airmccall@bellsouth.net Web:www.airmccall.com License:CMC1249941 Project Information For: Mike Curran,Atlantic investments 185 8th St.,Atlantic Beach, FL 32233 Design Conditions Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature(T) 70 75 Elevation: 43 ft Design TD (*F) 35 16 Latitude: 30'N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 8.4 52.8 Dry bulb(T) 35 91 Infiltration: Dailyrange(T) - 17 ( M Method Simplified VVetbulb(*F) - 77 Construction quality Average VVind speed (mph) 15.0 7.5 Fireplaces 0 Or Area Ll-value Insull R Htg HTM Loss C19 HTM Gain Construction descriptions If Bbjh/ft2-'F ft2-'F/Bkjh BbhlW Btuh Bhjhff Btuh Walls 446 0.203 2.0 7.02 3131 4.10 1828 14F-2:Blk wall,r-2 ext bd ins,4"thk n e 364 0.203 2.0 7.02 2558 4.10 1493 S 446 0.203 2.0 7.02 3131 4.10 1828 w 333 0.203 2.0 7.02 2337 4.10 1364 all 1589 0.203 2.0 7.02 11157 4.10 6514 Partitions (none) Windows 19.7 970 20.9 1028 1 D-c2ow:2 glazing,clr outr,air gas,wd frm mat,cir innr,1/4"gap, n 49 0.570 0 e 41 0.570 0 19.7 805 63.0 2573 1/8"thk S 49 0.570 0 19.7 970 25.2 1237 w 41 0.570 0 19.7 805 63.0 2573 all 180 0.570 0 19.7 3550 41.2 7411 Doors w 32 0.390 0 13.5 425 11.4 360 11 DO:Door,wd sc type Ceilings 3.47 6847 16C-1 1 al:Attic ceiling,asphalt shingles roof mat,r-1 1 ceil ins,1/2" 1975 0.081 11.0 2.80 5535 gypsum board int fnsh Floors 9397 0 0 22A-cph:Bg floor,heavy damp soil,on grade depth,carpet fir fnsh 200 1.358 0 47.0 2013-Apr-16 04:05:21 wrightsoft Right-Suite@ Universal 2012 12.1.06 Right JOD Mobile Page 1 �Jlm \wstmp\658ccf47-48cO-4lb2-bof2-dbfce8f7bb7O.rup Calc=MJ8 Front Door facesi N Job: wrightsoft AED Assessment Date: 4/16/2013 Entire House By: Robert Battinelli Air McCall Inc. 5771 Mining Ter.,#102,Jacksonville,FL 32257 Phonei 904-288-6110 Fax:904-288-6619 Email:airmcGall@belIsouth.net Web www.airmcrall.com License:CMC1249941 Project Information For: Mike Curran, Atlantic investments 185 8th St., Atlantic Beach, FL 32233 Design Conditions Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature (OF) 70 75 Elevation: 43 ft Design TD (OF) 35 16 Latitude: WON Relative humidity 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 8.4 52.8 Dry bulb(OF) 35 91 Infiltration: Dailyrange (OF) - 17 ( M Wetbulb(OF) - 77 Wind speed (mph) 15.0 7.5 Test for Adequate Exposure Diversity Hourly Glazing Load 10,00 9,00 8,00 7,00 6,00 5,00 4,00 3,00 2,00, 1,001,ri , — 0 i L i i i i i +----� 8 9 10 11 12 13 14 15 16 17 18 19 20 Hour of Day Hourly Aerage AEDIirTit Maximum hourly glazing load exceeds average by 19.0%. House has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh 2013-Apr-1604:05:21 wriiightSOft Right-Swteg Universal 2012 121�06 Right JV Mobile Page 1 Zb� �wstmp\658ccf47-48c0-41 b2-b0f2-dbfce8f71bb70.rup Calc=MJ8 Front Door faces: N N ,4/, ;7<- First Floor First Floc Job #: Air McCall Inc. Scale: 1 : 92 Performed by Robert Battinelli for: Page 1 Mike Curran 5771 Mining Ter.,#102 Right-Suite(Dunivarsal 2012 185 8th St. Jacksonville, FL 32257 12.1.06 Right J@ Mobile Atlantic Beach,FL 32233 Phone: 904-288-6110 Fax 904-288-6619 2013-Apr-1 6 04:05:22 ...-48cO-41 b2-bOf2-dbfce8f7bb7O.rup www.airmccall.com airmccall@bellsouth.net CERTIFIED�- www.ahridire ctory.a rg Certificate of Product Ratings AHRI Certified Reference Number: 5725542 Date: 4/16/2013 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 13HPX-036-230-17 Indoor Unit Model Number: CBX25UH-036-230-* Manufacturer: LENNOX INDUSTRIES, INC. Trade/Brand name: 13HPX SERIES Manufacturer responsible for the rating of this system combination is LENNOX INDUSTRIES, INC. Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity (Btuh): 34400 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Heating Capacity(Btuh) @ 47 F: 33400 Region IV HSPF Rating (Heating): 8.20 Heating Capacity(Btuh) @ 17 F: 21400 Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for clarnages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS I rposes. This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidentia reference pu The contents of this Cerfificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or othervAse utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org, A' C nditioning,Heating, click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on no ILI an"d R,efrigeration Institute Which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. @2013 Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 130105971047428694