Loading...
420 Main St 2013 HVAC CITY OF ATLANTIC BEACH 1 800 SEMINOLE ROAD J ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 �jyJ131�� Application Number . . . . . 13-00002497 Date 4/18/13 Property Address . . . . . . 420 MAIN ST Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ----------------------------------------------- Application desc 2 TONS 24000BTU ---------------------------------------------- Owner Contractor - ------------------------ ----------------------- WILLIAMS, PATRICK M. SNYDER HEATING & AIR 420 MAIN ST P.O. BOX 16826 ATLANTIC BEACH FL 32233 JACKSONVILLE FL 32245 (904) 641-0600 --------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . . 00 Permit Fee . . . . 91 . 00 Plan Check Fee Issue Date . . . . Valuation . . . . 0 Expiration Date . . 10/15/13 --------------------- ---------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----- ---------- ---------- - Permit Fee Total 91 . 00 91 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 95 . 00 95 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITU OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904)247-5826 Fax(904)247-5845 JOB ADDRESS' LiLi-7-0r-6 ' - PERMIT# PROJECT VALUE NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION ARI# SLc19 9 Air Conditioning: Unit Quantity I Tons Per Unit 'L REQUIRED Heat: Unit Quantity I BTU's Per Unit ZH000 Seer Rating \'S Duct Systems: Total CFM REQUIRED FIRE PREVENTION Re Fire Sprinkler System Quantity (Requires 3 sets of plans) ) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Tanks(gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name ti ;11;o.rw Phone Number 1p - q�19 Z Mechanical Company `Jn Q d Office Phone cA%-06Q0 Fax �o -l1-Z5Zq Co. Address: City S� � l�i _ State h.- Zip 3;-q-`A License Holder(Print): - I l State Certification/Registration# ICA S1330I- Notarized Signature of License Holder Sworn and subscribed before me this i day of 20 ! ZPRY PSB( I ajY A.FOUST MY COMMISSION#EE 204656 Signature of Notary Public * EXPIRES:July 21,2016 Ilk�jE OF FI�Po Bonded Thru Budget Notary Ser*es r Certificate of Product Ratings AHRI Certified Reference Number: 5439791 Date: 4/18/2013 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: GSZ130241B* Indoor Unit Model Number: ARUF30Bl4A*+TXV Manufacturer: GOODMAN MANUFACTURING CO., LP. Trade/Brand name: GOODMAN,JANITROL,AMANA DISTINCTIONS, EVERREST,ONE HOUR AIR CONDITIONING AND HEATING, ENERGI AIR Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP. Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity (Btuh): 23000 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Heating Capacity(Btuh) @ 47 F: 21600* Region IV HSPF Rating (Heating): 7.70 Heating Capacity(Btuh)@ 17 F: 13600 Ratinas followed by an asterisk(*)indicate a voluntary rerate of previously published data.unless accompanied with a WAS.which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org, Air-Conditioning,Heating, click on'Nerity Certificate"link and enter the AHRI Certified Reference Number and the date on A. ��-' and Refrigeration Institute which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. ©2013 Air-Conditioning,Heating,and Refrigeration Institute CERTIFICATE NO.: 130107626935415277 DesignStar Load Calculation Results are intended for use with Rheem heating and cooling systems The New Degree of C customer • . • Street Address 420 MAIN ST, Atlantic Beach, FL 32233 .................................................. Latitude, Longitude 30.3375°, -81.76860 House Square Footage: 1107 sq. ft. Name: GEORGIA WILLIAMS ..... ................. Phone: 123-123-1234 Email: example@mail.com _.........._ __ .................................._............--..... ,House • . • SHR •75 ............................._......._.........................................__....._............................_......._........_......................................................-_..........................................._...... Number of residents 2 ........................ .. ....................................................................................... ........................................................__............................_.................................... ...._...................... Ceiling height 9 Wall U-value ( R-value 0.09 11 ..................................................._....I................................................................. Floor U-value R-value 0.2 15 _ . _ Ceiling U-value R-value 0.053 1 19 ................_......................................................._......................._......................._.................__......_......_..................._...................... Window U-value 0.5 ................................................................. ...... Window SHGF 0.85 ........................._.........__ .........................--................................................................_.........._..........._..............._..........................._...................... ...................._...................... Moisture grains 53 .................... .. ..................................................................................................................................................................................._............................................. Duct loss % 10 ......................................._ Duct gain % 10 ............................_.................................................._........._............................................_.........._._...................... ..____ __._._....._...................................._.... Cooling infiltraction (ACH) 0.6 ......._....................................................._.............._....._.__.._.._.___........_........._.................. Heating infiltration (ACH) 0.8 ................................................................ Winter ventilation 0 ............. ............... ............. ...... ..................... ._....... .... _.......... ............................. ............................ _............ ................. ................_.......... _........... ... ..----......_........_._...__. Summer ventilation 0 ............. ......... ............................................_..........._...................._.........................................._..................................... ..........._.............._._....._.._._..._..... Design Conditions outdoor Heating Cooling ...................__.........................................._......__................._........................... .._...__ _......_. ....._. . Dry bulb (°F) 32 93 ._.._ ....................... ..........................................................................................................................._............................................................. Daily rangeM .............................. _._................_................. ...... Relative humidity 50% _........_ ............................................_......................._........................_..................................................._.................................. Moisture difference 53 ...................................................................................._............................................................_...._._..I............................._............................................................ Indoor Heating Cooling .. ............................................................................................................. Indoor temperature (°F) 70 75 _.._ Design temperature differenceff) 38 18 .................................. ......... ............................................ .............. . .. . ',Heatinq Load ._..._. W a I I Area Btuh % of load 3556 16.8 ........_.............. Floor 5297 25 ...................... ......__.._................._........_...._ _........ Ceiling 2229 10.5 ...................................... ......................._........._............._.................................._........_................. ......__ Windows 3002 14.2 ........I.............................. Infiltration 5164 24.4 ...........I................... System Efficiency Loss 1925 9.1 .......................................... .............................................. Tota 1: 21174 Heating Loads 21,174 BTU/hr r System Efficiency Loss Floor 4 j Ceiling Windows Infiltration \ Wall Cooling Loads . Area Btuh % of load Wall 2620 1u. ............... .. ......... Ceiling 3110 12 ................................................ ............... ................................. Windows 10163 39.1 Sensible Infiltration 1835 7.1 Latent Infiltration 3339 12.9 ........................_............................... _...._- System Efficiency Gain 2107 8.1 Internal 1882 7.2 ....................... ......... .. ... . ........ ......... Sensible People Load 460 1.8 ................. ......................................... .......................................... . Latent People Load 460 1.8 ............................. .................................... Total: 25975 .......................... . .................. ................................. Sensible load 22176 .................. Latent load 3799 SHR 0.85 ............................................................................................................................ ... ... ....................... Capacity at .75 SHR 2.46 Tons ............. ....... ................................................................................_...................................._........................ Cooling Loads 25,975 BTU/hr Sensible People Load Latent People Load Sensible Infiltration Internal Windows � i System Efficiency Wall r Ceiling Latent Infiltration • • - • .71 - • • AED Graph 15000 i 10000 9 5000 0 Sam 9am loam Ilam 12pm 1pm 2pm 3p 4pm 5pm 6pm 7pm Spm Hourly Loads —Average j • • ent selection System equipment selection will be made using the following derived values. Glass (E) 80 sq. ft. Glass (S) .........................................................................................._......................_........................................-................................................................._ ........................ Glass (N) 11 sq. ft. ..............................................._...............................................................................................__ . Glass (W) 56 sq. ft. ....................... ............................. ..................................................................._......................._......................_..............._........--.......................I....._....._ .............................. Summer Outdoor 930F ................................... .................................................. ....__.__...................................................._....__............_.................--...._..... ......................... Summer Wet Bulb 770F .................. .................... Summer Indoor 750F ...................................................................................................................................................._............................................._.__....... Summer Design Grains 50% ......... ... ..... Winter Outdoor 32°F ......................... _......._..........................._................_.................................._..........._............................ ...... __...._........ _............. _...._.......... _ Winter Indoor 70°F ............................._................-............................................................................................._........-..._._..-.._......_..................._..........................._.-....._.........._....._......._._... Sensible Cooling 22,176 Btuh ......................................................... ........... _ ......... .........................................._ Latent Cooling 3,799 Btuh ................................... .................... ......................................................................................._.....................I.......... ...........__ ....._......_......................... ................................... Required Cooling Airflow 1,008 CFM ............................................................................_.................................................-........._..................................................................._......................... Sensible Heating 21,174 Btuh ....................................-......................................................................................................................_ ...................... ........................ Required Heating Airflow 275 CFM 11...........-..................................................... .. _._... ................... All calculations are based upon approved hvac industry standards and procedures,and comply with all local, state and federal code requirements.All computed results are Estimates.Product provided by Energy Design Systems and Idea Tree