Loading...
1731 Beach Ave 2013 HVAC CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00002494 Date 4/18/13 Property Address . . . . . . 1731 BEACH AVE Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 CU 1 AHU ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ PARRISH ROBERT B. & FORREST OCEAN STATE HEAT & AIR, INC. 1731 BEACH 1476 ATLANTIC BLVD. FL 32266 ATLANTIC BEACH FL 322335838 NEPTUNE BEACH (904) 249-8251 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 87 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 10/15/13 ------ ---------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 87 . 00 87 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 91 . 00 91 . 00 . 00 . 00 PERMIT IS APPROVED ONL I' IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION �A ON CITY OF ATLANTIC BEACH goo Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247-5826 Fax (904) 247-5845 JOB ADDRESS: UZI 13-r-�- PERmrr# PROJECT VALUE S 31 :5-72, 71 NEW AIR CONDITIONING & BEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Ratm* g REQUIRED Duct Systems: Total CFM REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION AM 9 Y Y(o S16-1 6 Air Conditioning: Unit Quantity Tons Per Unit /. ,5- k -UIRED Heat: Unit Quantity BTU's Per Unit /I apo Seer Rating___j_3 Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantitv (Requires3 sets of plans) I (Requires 3 sets of plans) Fire Suppression Systems Quantity FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps �'-, Vented Wall Furnaces Refrigerator Condenser BTLT's 4 Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: or work is suspended or abandoned for six months.I hereby certify that I hre=ed Permit becomes void if work-does not commence within a six month pen isions of laws and ordinances governin,�this work-will be complied with whether speciBed this application and know the same to be true and correct. All prov state or local I � rmance of construction. or not. The permit does not give authority to violate the provisions of any other aw regulation construction or the perfo i Property Owners -Name fo- e-r-r-A Phone N,umber (007- :n 6 3 Mechanical Company -0. CQ&A -n,,h- WIC A a\., 4:r office Phone 1,y�-2�Lrt Fax-LYj---ZLY-9 City State R— ZiPATI-Wo Co. Address: I (7io Afi AAt, License Holder(Print): -r, 44 State cation/Registration 4 r-ACRY-9.2-1 0 Notarized Signature of License Holder day of )0-13 yvETTE P.MORALES orn an be 0 s NOTARY PUBLIC Signature of Notary ublic STATE OF FLORIDA Comm#EES79174 Expires 3/2r20`17 04/18/2013 07�04 FAX 9042498949 OCEAN-STATE-A/C ATLANTIC-BEACH [6002/003 ACCA Manual "J" Heat Load Calculation Date 04/17113 Customers Name Parrish Location Atlantic Beach Type of Construction Heat Transfer Multipliers Area or BTUH Exposure Notes HEATING COOLING Length HEATING COOLING 1 Gross Wall 376 2,3 Windows - Nc)rth Al, N, 2 29.0 15 435 240 East&West Al, E&W, 2 29.0 4135,Q, 23 667 1,058 South Al, S, 2 29.0 26-G, 8 232 200 4 Doors rront Solid Wood -Panel 27.0 16' .8 30 810 474 patio Solid Wood - Storm 16.4 9.7 60 984 582 Other SIdg Gi Dr, S, 2 32,6 25.0 0 0 0 5 Net Wall Area I R- 11, 112"Asp. Brd. 3.2 1'.9 240 766 456 Area 2 R_ 13, 1/2"Asp. Brd. 3.0 1.6, - 0 0 Area 3 R- 13, 1/2"Asp, Brd. 3.0 1.8 0 0 6 Ceilings 714 790 Area 1 Attic, R-22 1.9 2:1 376 Area 2 Attic, R- 19 2.1 2'.3,:' 0 0 2 19 0 Area 3 Attic, R- 19 2.1 2,31 0 7 Floors Area I Slab 40.5 0.0 1657 6,764 0 0 0 Area 2 None 0.0 8 Infiltration Winter summer Avg Cilng Ht Poor 1500 -2100 1.2 0.6, 9 3,730 3,123 15,104 mer 0.6 9 Sub Total STUH Loss 10 Duct BTUH Loss 1,510 ii TT-OTAL HEATING LOAD 16, 14 12 People and Appliances Bedrooms 1 ,3,200 10,123 13 Sub Total BTUH Gain (Structure) 14 Duct BTUH Gain Location Attic 15% 3,823 15 ITOTAL SENSIBLE -13,746 16 linfiltraton Latent Gain Infit, CFM 34 2,363 17 People Latent Gain #People 2 1,200 19 ITOTAL LATENT 1 3,663 19 I'Totall cooling Load 77309 04/18/2013 07:04 FAX 9042498949 OCEAN-STATE-A/C ATLANTIC-BEACH [a003/003 Fon" amsd CERTIFIED_�.,7 A al 7 L Certificate of Product Ratings AHRI Certified Reference NuMber: 4465686 oats: 4/17/2013 Product: Split System: Heat pump with Remote Outdoor UnitAin-Source Outdoor Unit Model Number:YHJD18S41S2 Indoor Unit Model Number:AHRi8B Manufacturer:YORK BY JOHNSON CONTROLS Trade/Brand name' LXSERIES Manufacturer responsible for the rating of this system combination Is YORK BY JOHNSON CONTROLS Rated as follows In accordance with AHRI Standard 21Gr2404008 for Unitary Air-Condltloning and Air-source Heat Pump Equipment and subject to verification of rating accuracy by AHR"ponsorgd,independent,third party testing; Cooling Capacity(Btuh): 18000 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Heating Capacity(Btuh)@ 47 F: 18000 Region IV H$PF Rating(Heating). 7.70 Heeting Capacity(Btuh)@ 17 F: 11400 Rgainp toliowed by an asterisk r)indicate a voluntary rtralee of pre'ADUSIY Pubil4hC4 dot&.unless accompanied��lh a WAS,winicti indicates,-invowntary rerate. DISCLAIMER as 10,a d mes no ponsibi n AHFJ don not andorse the pmduct(s)figed on this CaFtificau and makes no reproserdauorts,wamrides or ouarantims n assu r*8 lity to the producitia)Howd on this cartificift.AHRI exprunalY dllrtSlm5 all liability for damages ot any kind adming out uf the us4 or perFormanca of tho productM,or the unauthorized aneration of deti BMW an this rwonosta.Certified r3tings ara YaNci only for mod als and conrigurvitiorts Hated in the d Irwwry at www.phrldirectoryory. TERMS AND CONDITIONS noe re"renc rpo This Carocift and me Wntants are propriatary pioductsol'AHRI.This CgrUfIcStedhAll only be usedforindivi",personsland corinde 1 8 Pu N"- in%whole or in part.be reproduced;copled;dIGs9rni,w ;entered irdD a=nputur di"base;or otherwise utiltzeirl,In any The rontirats Of this CerttflemP may rl#� reftre ca form ormennororbywry means,qxemptilortheuver's Individual.pamonsland contiderMsi n CERTIFtCATE VERIFICATION -org, LAn Air-Condnioning.Heciting, The Information 1br the model Mod on thia cartificate Csit to verified at wwwAhridinectOrY I click on'Vertfy CV01111rAft"link and cuter the AHRI Cwt1flad Rvftranca Number and thb 0M on JOW No IL and Refrigeration fristitute which the Certificate was i"Lieo,which Ir fistod above,and the Ceifficaft Nc6,which Is listed below. CERTIFICATE NO.: C2013 Air-Conditioning,Heating,and Refrigeration Institute