289 Magnolia St 2013 HVAC CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 13-00002509 Date 4/22/13
Property Address . . . . . . 289 MAGNOLIA ST
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0 --------------
-------------------------------------------------------------
Application desc
1 cu 1 ahu
-- -------------------------------------------------------------------------
Owner Contractor
------------------------
--------- ----- - - ----
TRUSROTT, -ROBIN W & THEODORE OCEAN STATE HEAT & AIR, INC.
289 MAGNOLIA STREET 1476 ATLANTIC BLVD. FL 32266
ATLANTIC BEACH FL 32233 NEPTUNE BEACH
(904) 249-82S1
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . -
Permit Fee . . . . 95 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date 10/19/13 -----------------------
2 . 00
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 95 . 00 95 . 00 . 00 . 00
Plan Check Total . 00 * 00 . 00 . 00
Other Fee Total 4 . 00 4 * 00 . 00 . 00
Grand Total 99 . 00 99 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph(904) 247-5826 Fax (904) 247-5845
JOB ADDRESS: PERMU#
PROJECTVALUES
NEW -AJR CONDITIONING & BEATING SYSTEM INSTALLATION
Air Conditioning,: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating,,_
Duct Systems: Total CFM AEOULkED
REPLACEMETN7 AIR CONDITIONTENG & HEATING SYSTEM INSTALLATION
ARI# J 6 7 GZX0
Air Conditioning: Unit Quantity I Tons Per Unit 2-j- REQUIRED
Heat: Unit Quantity I BTU's Per Unit a z za 0. Seer Rating__�5-
Duct Systems: Total CFM REQUIRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Undergound Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantit-N
(Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLA-NTEOUS:
Prefabricated Fireplace Qty Automobile Lifts
Gas Piping Outlets Boilers BTUs
Elevators,'Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
4 Vented Wall Furnaces Refrigerator Condenser BTUs
4 Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER:
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I haveread
this application and know the same to be true and correct. All provisions of laws and ordinances governine this work-will be complied with whether specified
or not. The permit does no-,give authority to violate th--provisions of any other state or local law regulation construction or the performance ofconstruction.
Property Ovners Name T It,,!pAr-e- 7�-urtc-+ Phone Number 2-Y7 - G,3,A 9
Mechanical Company Oc:,&� An, Am aP A Office Phone 2-W 4 a j-1 Fax I Y.;-.3�v.9
I City IN w State r-1- Zip 3 2-Z4 L
Co. Address: t Y 7�. I
License Holder(Print): -To 6-153- A state Ue n/Registration 7'r CA-f-4 Vi,3 z 0
Notarized Sianature of License Holder /—Xll� A (1 75
,7 22w
YVETTE P.MORALErbW0 d su scn e ithis ky of .201
NOTARY PUBLIC
STATE OF FLORIDA Sigoptae of Notary ublic 0 Ali V�
V twl %_./V V
C4mni#EE879174
EV"s 3WN17
ACCA Manual "J" Heat Load Calculation Date 04/22/13
Customers Name Truscott Location Atlantic Beach
BTUH
Type of Construction Heat Transfer multipliers Area or COOLING
Exposure Notes HEATING COOLING Length HEATING
1,351
Gross Wall
F23 Windows —
North Al, N, 2 29.0 16.0 15 435 240
East& West Al, E &W, 2 29.0 46.0 112 3,248 5,152
Al, S, 2 29.0 25.0 20 580 500
South
1 12 t:35248
0
_E2 8
4 Doors --
Front Solid Wood - Panel /2-7.OU 15.8 30 810 474
Patio Solid Wood - Storm 16.4 97 60 984 582
--25.0 __
Other Sldg GI Dr, S, 2 32.6 Fff 0 0 0
5 Net Wall --
Area I R- 11, 1/2"Asp. Brd. 3.2 1.9 1,114 3,565 2,117
Area 2 R- 13, 1/2"Asp. Brd. 3,0 -11.8 0 0
Area 3 R- 13, 1/2"Asp. Brd. 3.0 1.8 0 0
6 Ceilings —
Area I Attic, R-22 1.9 2.1 1,351 2,567 2,837
Area 2 Attic, R- 19 2.1 2.3 0 0
Area 3 Attic, R- 19 2.1 2.3 0 0
7 Floors —
Area I Slab 40.5 0.0 167 6,764 0
Area 2 None 0.0 0.0 0 0
8 Infiltration Winter Summer Avg Cilng Ht
I Poor 1500 -2100 1�2 0.6 9 7,632 4,963
9 Sub Total BTUH Loss -- - 26,584
2,658
—10 Duct BTUH Loss
11 TOTAL HEATING LOAD 29,243
12 People and Appliances Bedrooms 3 3,000
13 Sub Total BTUH Gain (Structure) 19,865
14 Duct BTUH Gain Location Attic 15% 2,980
:— 22,844
15 TOTAL SENSIBLE —
16 Infiltraton Latent Gain Infit. CFIVI 122 4,225
17 People Latent Gain # Peopie--- 4 920
19 TOTAL LATENT 5,145
19 Total Cooling Load !7,990
This combination qualifies for a Federal Energy
Efficiency Tax Credit when placed in service
CERTIFIEDT. between Feb 17, 2009 and Dec 31, 2013.
tvvvw.a h r 1 d ire cto ry.or g 4
Certificate of Product Ratings
AHRI Certified Reference Number: 3676250 Date: 4/17/2013
Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source
Outdoor Unit Model Number: 25HCC530A**30
Indoor Unit Model Number: FV4CNFOO2
Manufacturer: CARRIER AIR CONDITIONING
Trade/Brand name: PERFORMANCE 15 PURON HP
Manufacturer responsible for the rating of this system combination is CARRIER AIR CONDITIONING
Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third
party testing:
Cooling Capacity(Btuh): 28000
EER Rating (Cooling): 12.50
SEER Rating (Cooling): 15.00
Heating Capacity(Btuh)@ 47 F: 27800*
Region IV HSPF Rating (Heating): 8.50
Heating Capacity(Btuh)@ 17 F: 16700
Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate.
DISCLAIMER
AHRI does,not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for,
the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance ofthe product(s),or the
unauthorized afteration of data listed on this Cerdficate.Certified ratings are valid only for models and configurabons listed in the directory at www.ahridirectory.org.
TERMS AND CONDITIONS
This Certificate and its contents are proprietary products ofAHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.
The contents of this Certificate may not in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any
form or manner or by any means.except for the user's individual,personal and confidential reference.
CERTIFICATE VERIFICATION
The information for the model cited on this ceftfficate can be verified at www.ahridire(;tory.org, Air-Conditioning,Heating,
click on'Verify Certificate"link and enter the AHRI Certified Reference Number and the date on On ILI and Refrigeration Institute
which the cerfificate was issued,which is listed above,and the Certificate No.,which is listed below.
@2013 Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO.: 130107043990313088