1925 Seminole Rd 2013 HVAC CITY OF ATLANTIC BEAC.11
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 13-00002514 Date 4/23/13
Property Address . . . . . . 1925 SEMINOLE RD
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0 ------
----------------------------------------------------------------------
Application desc
3 . 5 tons 42000 BTU' s
-------------------------------------------------------------
Owner Contractor
------------------------
------------------------
MCKENNA, ROBERT E DONOVAN HEATING & AIR
1925 SEMINOLE ROAD 315 SIXTH AVENUE SOUTH
ATLANTIC BEACH FL 32233 JACKSONVILLE BEACH FL 32250
(904) 241-3785
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . - . 00
Permit Fee . . . . 103 . 00 Plan Check Fee
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 10/20/13 ---------------
-------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 103 . 00 103 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 107 . 00 107 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALI, CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
This combination qualifies for a Federal Energy
I "Imp Efficiency Tax Credit when placed in service
111111111111111ki CERTIFIEDT.
www.ahridirectory.org between Feb 17, 2009 and Dec 31, 2013.
A
Certificate of Product Ratings
AHRI Certified Reference Number: 3650161 Date: 4/23/2013
Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source
Outdoor Unit Model Number: TXH542GKA*
Indoor Unit Model Number: FVWX48*�**
Manufacturer: TEMPSTAR
Trade/Brand name: SMARTCOMFORT TX 5500 R410A HP
Manufacturer responsible for the rating of this system combination is TEMPSTAR
Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third
party testing:
Cooling Capacity(Btuh): 42000
EER Rating (Cooling): 12.50
SEER Rating (Cooling): 15.50
Heating Capacity(Btuh) @ 47 F: 42000
Region IV HSPF Rating (Heating): 8.70
Heating Capacity(Btuh) @ 17 F: 25800
Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate.
DISCLAIMER
AHRI does not endorse the product(s)listed on this Certificate and makes no representations.warranties or guarantees as to,and assumes no responsibility for,
the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),orthe
unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory atwww.ahridirectory.org.
TERMS AND CONDITIONS
This Certificate and its contents are proprietary products of AHRL This Certificate shall only be used for individual,personal and confidential reference purposes.
The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any
form or manner or by any means,except for the user's individual,personal and confidential reference.
CERTIFICATE VERIFICATION
The information for the model cited on this certificate can be verified at www.ahridirectory.org, 04 "IMF, Air-Conditioning,Heating,
click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on A00W 00 ILI and Refrigeration Institute
which the certificate was issued,which is listed above,and the Certificate No.,which is listed below.
@2013 Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 130111948628783641
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach,FL 32233
Ph(904)247-5826 Fax(904)247-5845
JOB ADDREss:-- PERIMT#
PROJECTVALUE$
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Pe'r Unit Seer Rating
Duct Systems: Total CFM
MQULRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
AM4 A-,
Air Conditioning: Unit Quantity Tons Per Unit '3 -r Cl(,l
Heat REQULRED
Unit Quantity-I BTU's Per Unit SeerRating 11�- S
Duct Systems: Total CFM -REQ
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty Automobile Lifts
Gas Piping Outlets Boilers BTU's-
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
#Water Heaters Solar Collection Systems
Tanks(gallons)
Wells
3THER:
,ermit becomes void if work does not commence within a six month pericid or work is suspended or abandoned for six months.I hereby certify that I have read
iis application and know the same to be true and coirrmt. All provisions of laws and ordinances governing this work will be complied with whether specified
r not lie permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction-
toperty Owners Name i4,A,, 1(e
_V,\Y)C Phone Number q0 7-gD V0
lechanical Company --I— Office Phone V1 1-3*7 LrFax -LH I-3-?'IS-
o-Address: -z 1,�;- -S, City �� e. -Ge4ck _State C Zip
icense Holder(Print): U�&v� State Certification/Registration# if-4 C031-) 61
i9tarized Sknature of License HoMer
and subscribed before me this 'Z,3 day of P
f �i - 20/�-
.00 ft Notary Public State of Flo a
Hughes
EE 1 86278
T'Mothy L
innothyLee Hughes Si of Notary Public
M Cr
My Commission EE 186278
01(5
Expires 04103/20=16
E;?
Job:
Project Summary Date: 4/15/13
+ wrightsoft Entire House By: Brandon Zaharie
Donovan Heat & Air
315 6th ave south, Jacksonville Beach, FL 32250 Phone.241-3785 Email: brandon(gdonovanac.com
For: Mckenna
1925 Seminole RD, Atlantic Beach, FL 32233
Notes:
Weather: Jacksonville Mayport Naval, FL, US
Winter Design Conditions Summer Design Conditions
outside db 39 'F Outside db 95 'F
Inside db 68 'F Inside db 75 'F
29 'F Design TD 20 'F
Design TD Daily range L
Relative humidity 50 %
Moisture difference 53 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 17933 Btuh Structure 15831 Btuh
Ducts 6189 Btuh Ducts 12799 Btuh
Central vent (33 cfm) 727 Btuh
Central vent (33 cfm) 1054 Btuh 0 Btuh
Humidification 0 Btuh Blower
Piping 0 Btuh Use manufacturer's data in
Equil5ment load 25176 Btuh Rate/swing multiplier 1.00
Infiltration Equipment sensible load 29357 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
1 (Average) Structure 1948 Btuh
Fireplaces Ducts 2254 Btuh
Heati n Coolin Central vent (33 cfm) 1196 Btuh
Area (ft') 17N 17N Equipment latent load 5397 Btuh
Volume(ft') 16146 16146
Air changes/hour 0.45 0.20 Equipment total load 34754 Btuh
Equiv.AVF (cfm) 122 54 Req. total capacity at 0.70 SHR 3.5 ton
Heating Equipment Summary Cooling Equipment Summary
Make Tempstar Make Tempstar
Trade Trade TXH542
Model TXH542 Cond
Coil FVM4X48
ARI ref no. 3650161 ARI ref no. 3650161 15.5 SEER
8.7 HSPF Efficiency
Efficiency Sensible cooling 30163 Btuh
Heating input 12927 Btuh
Heating output 42875 Btuh @ 47'F Latent cooling 43090 Btuh
Temperature rise 27 oF Total cooling
Actual air flow 1436 cfm Actual air flow 1436 cfm
Air flow factor 0.060 cfm/Btuh Air flow factor o.050 cfm/Btuh
0 in H20 Static pressure 0 in H20
Static pressure Load sensible heat ratio 0.84
Space thermostat
Printout certified by ACCA to meet all requirements of Manual J 8th Ed. 2013-Apr-19 11150:18
,gE:� vvjriQ"t:,sc3,fit Right-Suite�V Universal 7.1.01 RSU05996 Page 1
ACCA c:\users\Sates\Documents\Wrightsoft HVAC\3.5TON Calc=MJ8 Orientation=N