343 19th ST HVAC PERMIT CITY OF ATLANTIC BEACH ,
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 13-00002S35 Date 4/24/13
Property Address . . . . . . 343 19TH ST
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
1 CU 1 AHU 3 . S TONS
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
OZIMKOVSKI YEVENIY & LAURA L DONOVAN HEATING & AIR
343 19TH ST 31S SIXTH AVENUE SOUTH
ATLANTIC BEACH FL 32233 JACKSONVILLE BEACH FL 322SO
(904) 241-3785
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee . . . . 103 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 10/21/13
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DEPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 103 . 00 103 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 107 . 00 107 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
This combination qualifies for a Federal Energy
Efficiency Tax Credit when placed in service
CERTIFIEDTM between Feb 17, 2009 and Dec 31,2013.
ww w.a h rid i rec to ry.a rg
Certificate of Product Ratings
AHRI Certified Reference Number: 3650246 Date: 4/24/2013
Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source
Outdoor Unit Model Number: TXH542GKA*
Indoor Unit Model Number: FXM4X42**A*
Manufacturer: TEMPSTAR
Trade/Brand name: SMARTCOMFORT TX 5500 R410A HP
Manufacturer responsible for the rating of this system combination is TEMPSTAR
Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third
party testing:
Cooling Capacity(13tuh): 41500
EER Rating (Cooling): 12.50
SEER Rating (Cooling): 15.00
Heating Capacity(Btuh)@ 47 F: 36800
Region IV HSPF Rating,(Heating): 8.70
Heating Capacity(Btuh)@ 17 F: 26400
Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate.
DISCLAIMER
AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for,
the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),orthe
unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org.
TERMS AND CONDITIONS
This Certificate and Its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.
The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any
form or manner or by any means,except for the user's individual,personal and confidential reference.
CERTIFICATE VERIFICATION
The information for the model cited on this certificate can be verified at wwwahridirectory.org, A "IMP, Air-Conditioning,Heating,
click on"Verity Certificate"link and enter the AHRI Certified Reference Number and the date on
which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. 0%1 No ILI and Refrigeration Institute
02013 Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO.: 130112924059109715
MECHANICAL PE11MIT APPLICATION
CITY OF ATLANTIC BFACH
800 Seminole Rd Atlantic Beach,FL 32233
Ph(904)247-5826 Fax(904)247-5945
JOBADDRM: PERMIT#
PROJECT VALUE$ 6-0
NEW AIR CONDITIONING&BEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per.Unit
Heat: UrtaQsr BTLPs Per Unit
Duct System: T
REPLACEMEM AIR CONDITIONING&BEATING SYSTEM INSTALLATION
Air unit I*. y I Tons Per Unit 3-S ARI# S6LLz-,v("
Heat: Unit Quantit3r--.L— BTUs Per Unit 0 Q) MEMO
DuctSystems.- Total CFM — Seer Rafitqg--/!5
FHM PREVENTION
Fire Sprinkler System Quantity QReqvkes 3 sets of
But Stmidpipe Quantity (ReqWres 3 sets of
UndaW .Fire Main Phws)
value (Itequku 3 seb of ph=)
Fire Hose Cabinets Quantit
y QRequkes 3 sets of ph=)
Commercial Hoods Quantity
Fire S%Vression Systems (Itequires 3 sets of phums)
Quantity (Requhvs 3 seft of plains)
FMPLACES MISCELLANEOUS.-
Prefidzicaftd,Fireplace Qty Automobile Lffks
Gas P4)ing Outlets Boilers BTLPs
ALL OTHER GAS PIPING MeVSDE��S�tors
Quantity of Outlets Heat Exchmger
#Vented Wall Fumaces Reffigerator Condenser BT(Ps
#Water Heaters Solar Collection Systems
Tanks(gallons)
wells
X11ER:
'eradtbecome-s void ifwork does not CM w-m-nem wfthin a six mouth period or work is suspended orabandoned for six months.I hereb7c�fttlfy that I have read
115 appfication.and Imowthe smw bD be true and CMOCL AR POMM of 1xws and wgnmm WMI&Wths waik wffl be mqftd with
r noL 7be Permit does not gin mdwft to viohft the prov whedwspwiffed
I 'S'0w ofany other stute Or 10c8l law n3gulation construction orthePerbmance ofconstruction.
toperty Owners Name_&
IGE Ntp 021 A"%U 0' . PhOneNuMber TOY �ZZ 2-318
ledbanical Company D--viova A tler-.+ -t- A, Phone S�t 1-3*7 K�Nx-JaL3195-
b.Address: -9 IS- L,�� city
- -0" State f- zip 3.4z�"Sb
icense,Holder(Prbt).- w-%Wr-w� State Cmification/Regishation#
btm*Ad s4puftffe 01f
ot Flodda
t4otoly PUbfiC Stalte Sworn and subscribed before me this 2 day of
�01 AN 4 thy Loe VjUghes 78 -20LL
7 _E ja62
mv C
c Signature of Not"Public
r
pires 041031201
Of*v
Job:
wrightsoft. Project Summary Date: 4124/13
Entire House By: Brandon Zaharie
Donovan Heat & Air
315 6th ave south,Jacksonville Beach,FL 32250 Phone:241-3785 Email:brandon(§donovanac.com
Project Information
For: Ozimukovski
343 19 th st,Atlantic Beach, FL 32233
Notes:
Design Information
Weather: Jacksonville Mayport Naval, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 39 OF Outside db 95 OF
Inside db 68 OF Inside db 75 OF
Design TD 29 OF Design TD 20 OF
Daily range L
Relative humidity 50 %
Moisture difference 53 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 17933 Btuh Structure 15831 Btuh
Ducts 6189 Btuh Ducts 12799 Btuh
Central vent (33 cfm) 1054 Btuh Central vent (33 cfm) 727 Btuh
Humidification 0 Btuh Blower 0 Btuh
Pipl�g 0 Btuh
Equipment load 25176 Btuh Use manufacturer's data n
Rate/swing multiglier 1.00
Infiltration Equipment sensi le load 29357 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 1 (Average) Structure 1948 Btuh
Ducts 2254 Btuh
Heafi
7N Coolin Central vent (33 cfm) 1196 Btuh
Area ft' 1 17N Equipment latent load 5397 Btuh
Volume 16146 16146
Air changes/hour 0.45 0.20 Equipment total load 34754 Btuh
Equiv.AVF (cfm) 122 54 Req. total capacity at 0.70 SHR 3.5 ton
Heating Equipment Summary Cooling Equipment Summary
Make Tempstar Make Tempstar
Trade Trade
Model TXH542 Cond TXH542
ARI ref no. 3650246 Coil FXM4X42
ARI ref no. 3650246
Efficiency 8.7 HSPF Efficiency 15 SEER
Heating input Sensible cooling 30163 Btuh
Heating output 42875 Btuh @ 47'F Latent cooling 12927 Btuh
Temperature rise 27 OF Total cooling 43090 Btuh
Actual air flow 1436 cfm Actual air flow 1436 cfm
Air flow factor 0.060 cfm/Btuh Air flow factor 0,050 cfm/Btuh
Static pressure 0 in H20 Static pressure 0 in H20
Space thermostat Load sensible heat ratio 0.84
Printout certified by ACCA to meet all requirements of Manual J 8th Ed.
-PW wwriloft1twc.14t- Right-Suite@ Universal 7.1.01 RSU05996 2013-Apr-24 10:02:50