Loading...
343 19th ST HVAC PERMIT CITY OF ATLANTIC BEACH , 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00002S35 Date 4/24/13 Property Address . . . . . . 343 19TH ST Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 CU 1 AHU 3 . S TONS ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ OZIMKOVSKI YEVENIY & LAURA L DONOVAN HEATING & AIR 343 19TH ST 31S SIXTH AVENUE SOUTH ATLANTIC BEACH FL 32233 JACKSONVILLE BEACH FL 322SO (904) 241-3785 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 103 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 10/21/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DEPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 103 . 00 103 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 107 . 00 107 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. This combination qualifies for a Federal Energy Efficiency Tax Credit when placed in service CERTIFIEDTM between Feb 17, 2009 and Dec 31,2013. ww w.a h rid i rec to ry.a rg Certificate of Product Ratings AHRI Certified Reference Number: 3650246 Date: 4/24/2013 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: TXH542GKA* Indoor Unit Model Number: FXM4X42**A* Manufacturer: TEMPSTAR Trade/Brand name: SMARTCOMFORT TX 5500 R410A HP Manufacturer responsible for the rating of this system combination is TEMPSTAR Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity(13tuh): 41500 EER Rating (Cooling): 12.50 SEER Rating (Cooling): 15.00 Heating Capacity(Btuh)@ 47 F: 36800 Region IV HSPF Rating,(Heating): 8.70 Heating Capacity(Btuh)@ 17 F: 26400 Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),orthe unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and Its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at wwwahridirectory.org, A "IMP, Air-Conditioning,Heating, click on"Verity Certificate"link and enter the AHRI Certified Reference Number and the date on which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. 0%1 No ILI and Refrigeration Institute 02013 Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO.: 130112924059109715 MECHANICAL PE11MIT APPLICATION CITY OF ATLANTIC BFACH 800 Seminole Rd Atlantic Beach,FL 32233 Ph(904)247-5826 Fax(904)247-5945 JOBADDRM: PERMIT# PROJECT VALUE$ 6-0 NEW AIR CONDITIONING&BEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per.Unit Heat: UrtaQsr BTLPs Per Unit Duct System: T REPLACEMEM AIR CONDITIONING&BEATING SYSTEM INSTALLATION Air unit I*. y I Tons Per Unit 3-S ARI# S6LLz-,v(" Heat: Unit Quantit3r--.L— BTUs Per Unit 0 Q) MEMO DuctSystems.- Total CFM — Seer Rafitqg--/!5 FHM PREVENTION Fire Sprinkler System Quantity QReqvkes 3 sets of But Stmidpipe Quantity (ReqWres 3 sets of UndaW .Fire Main Phws) value (Itequku 3 seb of ph=) Fire Hose Cabinets Quantit y QRequkes 3 sets of ph=) Commercial Hoods Quantity Fire S%Vression Systems (Itequires 3 sets of phums) Quantity (Requhvs 3 seft of plains) FMPLACES MISCELLANEOUS.- Prefidzicaftd,Fireplace Qty Automobile Lffks Gas P4)ing Outlets Boilers BTLPs ALL OTHER GAS PIPING MeVSDE��S�tors Quantity of Outlets Heat Exchmger #Vented Wall Fumaces Reffigerator Condenser BT(Ps #Water Heaters Solar Collection Systems Tanks(gallons) wells X11ER: 'eradtbecome-s void ifwork does not CM w-m-nem wfthin a six mouth period or work is suspended orabandoned for six months.I hereb7c�fttlfy that I have read 115 appfication.and Imowthe smw bD be true and CMOCL AR POMM of 1xws and wgnmm WMI&Wths waik wffl be mqftd with r noL 7be Permit does not gin mdwft to viohft the prov whedwspwiffed I 'S'0w ofany other stute Or 10c8l law n3gulation construction orthePerbmance ofconstruction. toperty Owners Name_& IGE Ntp 021 A"%U 0' . PhOneNuMber TOY �ZZ 2-318 ledbanical Company D--viova A tler-.+ -t- A, Phone S�t 1-3*7 K�Nx-JaL3195- b.Address: -9 IS- L,�� city - -0" State f- zip 3.4z�"Sb icense,Holder(Prbt).- w-%Wr-w� State Cmification/Regishation# btm*Ad s4puftffe 01f ot Flodda t4otoly PUbfiC Stalte Sworn and subscribed before me this 2 day of �01 AN 4 thy Loe VjUghes 78 -20LL 7 _E ja62 mv C c Signature of Not"Public r pires 041031201 Of*v Job: wrightsoft. Project Summary Date: 4124/13 Entire House By: Brandon Zaharie Donovan Heat & Air 315 6th ave south,Jacksonville Beach,FL 32250 Phone:241-3785 Email:brandon(§donovanac.com Project Information For: Ozimukovski 343 19 th st,Atlantic Beach, FL 32233 Notes: Design Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 OF Outside db 95 OF Inside db 68 OF Inside db 75 OF Design TD 29 OF Design TD 20 OF Daily range L Relative humidity 50 % Moisture difference 53 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 17933 Btuh Structure 15831 Btuh Ducts 6189 Btuh Ducts 12799 Btuh Central vent (33 cfm) 1054 Btuh Central vent (33 cfm) 727 Btuh Humidification 0 Btuh Blower 0 Btuh Pipl�g 0 Btuh Equipment load 25176 Btuh Use manufacturer's data n Rate/swing multiglier 1.00 Infiltration Equipment sensi le load 29357 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 1948 Btuh Ducts 2254 Btuh Heafi 7N Coolin Central vent (33 cfm) 1196 Btuh Area ft' 1 17N Equipment latent load 5397 Btuh Volume 16146 16146 Air changes/hour 0.45 0.20 Equipment total load 34754 Btuh Equiv.AVF (cfm) 122 54 Req. total capacity at 0.70 SHR 3.5 ton Heating Equipment Summary Cooling Equipment Summary Make Tempstar Make Tempstar Trade Trade Model TXH542 Cond TXH542 ARI ref no. 3650246 Coil FXM4X42 ARI ref no. 3650246 Efficiency 8.7 HSPF Efficiency 15 SEER Heating input Sensible cooling 30163 Btuh Heating output 42875 Btuh @ 47'F Latent cooling 12927 Btuh Temperature rise 27 OF Total cooling 43090 Btuh Actual air flow 1436 cfm Actual air flow 1436 cfm Air flow factor 0.060 cfm/Btuh Air flow factor 0,050 cfm/Btuh Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat Load sensible heat ratio 0.84 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. -PW wwriloft1twc.14t- Right-Suite@ Universal 7.1.01 RSU05996 2013-Apr-24 10:02:50 ,41M c:\userskSales\Documents\Wrightsoft HVAC\3.5TON Calc=MJ8 Orientation=N Page 1