Loading...
1243 LINKSIDE DR HVAC PERMIT L)ku`1 r I ItCITY OF ATLANTIC BEACH j 800 SEMINOLE ROAD J =�" ATLANTIC BEACH,FL 32233 ., INSPECTION PHONE LINE 247-5814 ~:*✓J� ."'tel Application Number . . . . . 13-00002537 Date 4/24/13 Property Address . . . . . . 1243 LINKSIDE DR Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 CU 1 AHU 3 TONS ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ DIOCESE OF ST AUGUSTINE DONOVAN HEATING & AIR C/O BISHOP VICTOR GALEONE 315 SIXTH AVENUE SOUTH 11625 OLD SAINT AUGUSTINE RD JACKSONVILLE BEACH FL 32250 JACKSONVILLE FL 322582056 (904) 241-3785 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 99 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 10/21/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 99 . 00 99 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 103 . 00 103 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE. WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. 4 MECHANICAL PERMIT APPLICATION CITY OF ATLAN'ITIC BEACH 800 Seminole Rd Atlantic Beach,FL 32233 Ph(904)247-5826 Fax(904)247-5845 JOB AWims: 12— Lrivsid, -Dr PKR IIT# PROJECTVALUE y8(WD NEW AIR CONDITIONING&HEATING SYSTEM INSTALLATION Air Conditioning: Unit QTY Tons Pea.Unit Heat: Unit Quairiity BTU's Per Unit Seer .Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING&HEATING SYSTEM INSTALLATION Air Conditioning: ni Quantity + Tons Per Unit 3 ARI#j" �W-v Heat: Q .L— BTU's Per Unit 3r:,nOCJ Seer Rativa JS Duct Systems: Total CFM REQIIIRE'D FIRE PREVENTION Fire Fire S�System Q�t9 (Requires 3 sets of per) Quantlt3' (Requires 3 seas of lam Underground Fire Main Value 3 sets of plans) Fire Hose Cabinets Quantity (Regwres 3 sets of plans) Commercial Hoods (Requires 3 sets of Fre Suppression Systems �� 3 bans) sets of plans) FIRE PLACES MISCELLANEOUS: fim Priffiib uxit�ed��lace Qty_, Automobile Lifts Gas�g Boilers BTU's FlevALL OTHER GAS PIPING Heat ER islEscaiators dtanger Quantity of Outlets #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Wellss(gallons) DTHER: emut becomes void ifvvak does not anem virt>un a six month period or work is=q=dcd or abamdnod far six months.I hereby cm fy that I have read tis appliC"M andknowthe samto be tramand cont Alt provisions oflaws and ordhmn es this ght m tho�ty to violatia the watt will be sped rnoL T7>Cptxmit does nal ^ Pmvlsioas ofany other or local law mdatim conmuction or thepeffmMance ofcanstractiom topWy Owners Name _ ��Y� ter � Phone Number `1 -(7at!( Zecbanic al Company-U�nc ivc,n f �-- t rc. Office Phone 2'i 1-31 LrFax I,,-i Y3�`'IS b.Address: 31 S [per daarc, S, City O&V Gzf c k Sta '+L. Zip 3 aaSv icense Holder(Print): ; l��i+� rwvG n Stm Cerfiicati 'on#_Lc Co-3- 161 iced Skmhwe of HoUw rtirwr�r Sworn and subxnbed before me this_2_day of _�_2O LL �.M+ Notary Pudic State of Flo dpi of Notary Public ` Jv Timothy tee Hughes My Comm"m EE 188278 a Expires 04/03/2018 wri so htft® Project Summary Job: 9 Date: April 17,2013 Entire House By: Aaron Thacker Donovan Heat & Air 315 6th Ave S,Jacksonville Beach,FL 32250 Phone:904-241-3785 Fax.904241-3745 Email:aaron@donovanac.com Web:www.DonovanAC.com Project Information For: Mark Waters 1243 Linkside Dr, Atlantic Beach, FL 32233 Notes: Design Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 OF Outside db 95 OF Inside db 70 OF Inside db 75 OF Design TD 31 OF Design TD 20 OF Daily range L Relative humidity 50 % Moisture difference 53 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 26705 Btuh Structure 20836 Btuh Ducts 4945 Btuh Ducts 4814 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 31649 Btuh Use manufacturer's data n Ratelswing multiplier 1.00 Infiltration Equipment sensible load 25651 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1154 Btuh Ducts 2066 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area(ft') 1040 1040 Equipment latent load 3220 Btuh Volume(W) 8320 8320 Air changes/hour 0.45 0.23 Equipment total load 28871 Btuh Equiv.AVF (cfm) 62 32 Req. total capacity at 0.70 SHR 3.1 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade COMFORT 15 PURON SINGLE STAGE ... Trade COMFORT 15 PURON SINGLE STAGE Model 25HCC536A**30 Cond 25HCC536A**30 AHRI ref no3676268 Coil FX4DN((B,F)037 AHRI ref no367626$ Efficiency 8.7 HSPF Efficiency 12.5 EER, 15 SEER Heating input Sensible cooling 24360 Btuh Heating output 35200 Btuh @ 47°F Latent cooling 10440 Btuh Temperature rise 28 OF Total cooling 34800 Btuh Actual air flow 1160 cfm Actual air flow 1160 cfm Air flow factor 0.037 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.89 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wrl9 Right-Suite®Universal 8.0.24 RSU05995 htsoft° 2013-Apr-1914:18:02 C:\Users\Owner\Documents\Wrightsoft HVAC\Bogus 3 ton.rup Calc=MJ8 Front Door faces: S Page 1 ��IIII� This combinationualifies for a Federal Ener Efficiency Tax Credit when placed in seryge between Feb 17, 2009 and Dec 31,2013. r Certificate of Product Ratings AHRI Certified Reference Number: 3676268 Date: 4/24/2013 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 25HCC536A**30 Indoor Unit Model Number: FX4DN(B,F)037 Manufacturer: CARRIER AIR CONDITIONING Trade/Brand name: PERFORMANCE 15 PURON HP Manufacturer responsible for the rating of this system combination is CARRIER AIR CONDITIONING Rated as follows in accordance with AHRI Standard 2101240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity(Btuh): 34800 EER Rating (Cooling): 12.50 SEER Rating (Cooling): 15.00 Heating Capacity(Btuh)@ 47 F: 34400*: Region IV HSPF Rating(Heating): 8.50* Heating Capacity(Btuh)@ 17 F: 22000 Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION ��, The information for the model cited on this certificate can be verified at www.ahridirectory.org, Air-Conditioning,Heating, click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on 0%2 on �' and Refrigeration Institute which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. 02013 Air-Conditioning,Heating,and Refrigeration Institute CERTIFICATE NO.: 130112925559196115