Loading...
2041 BEACH AVE HVAC PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00002534 Date 4/24/13 Property Address . . . . . . 2041 BEACH AVE Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 CU 1 AHU 2 . 5 TONS ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ BROTMAN SOLOMON G & LESLIE G ENVIRONMENTAL A/C SERVICES, INC 2041 BEACH AVE 8110 CYPRESS PLAZA DR STE 106 ATLANTIC BEACH FL 322335934 JACKSONVILLE FL 32256 (904) 279-0030 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 95 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 10/21/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 95 . 00 95 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 99 . 00 99 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247-5826 Fax (904) 247-5845 JOB ADDRESS: C %ve PEmrfT-�,, PROJECT VALUE NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQ REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit "� -'�3 ARI #REQUIRED Heat: Unit Quantity BTU's Per Unit'�O,wo Seer Rating \AS Duct Systems: Total CFM RE Q UIR—ED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans Fire Standpipe Quantity (Requires 3 sets of-platis) Underground Fire Main— Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty_ Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTUs # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name Cao Phone Number r\2�1 Mechanical Compan �, -...Rffice Phone-��'\-"Z�Wax a��cl Co. Address`--�'--,\��) City License Holder(Print)-%-\,,—,Z� `4N, State Certification/Registration Notarized Signature of License Holder,,t, Sworn and subscribed before me this day of 20\'�, KAY VEGA-NAVARRO Signature of No-t—ar—yT-'5- 14Q. 'ubli�c , Commission#DD 972187 -,,q Expires July 17,2014 Smded Thtu Tmy P*n im"m 800 ANNON CERTIFIED,. L w ww.ah rid ire cto ry,org A� Certificate of Product Ratings AHRI Certified Reference Number: 4563144 Date: 4/23/2013 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 4TWR303OB1 Indoor Unit Model Number: *AM7AOB3OH21 Manufacturer: TRANE Trade/Brand name: XR13 WEATHERTRON Manufacturer responsible for the rating of this system-combination is TRANE Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity(13tuh): 30000 EER Rating (Cooling): 12.00 SEER Rating (Cooling): 14.50 Heating Capacity(Btuh) @ 47 F: 28800 Region IV HSPF Rating (Heating): 9.00 Heating Capacity(Btuh)@ 17 F: 17400 Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for,' the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the una rth nri7pd lafteratinn of data listed on this Certificate.Certified ratings are valid only for models and configurations listed In the directory at www.ahr rectory.org. TERMS AND CONDITIONS This Certificate and Its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidentlat feterence purposes. The contents ofthis Certificate may not,in whole or In part be reproduced;copied;disseminated;entered into a computer clatabasi7-5—r otherwise utilized,in any form or manner or by any means4gpept for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at wwwahridirectory.org, AS "IMP, Air-Conditioning,Heating, click on"Verify Certificate"link and enterthe AHRI Certified Reference Number and the date on which the certificate was Issued,which Is listed above,and the Certificate No.,which is listed below. 0%0 on ILI and Refrigeration Institute 02013 Air-Conditioning,Heating,and Refrigeration Institute CERTIFICATE NO.: 130111982075397555 wrightsoft Project Summary Entire House By: M.Ellis Energy Design Systems, Inc. Project Information For: Brotman Residence Changeout 2041 Beach Avenue, Atlantic Beach, FL Notes: Front door faces South Design Information Weather: Jacksonville, Int'IAP, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 OF Outside db 94 OF Inside db 74 OF Inside db 74 OF Design TD 42 OF Design TD 20 OF Daily range M Relative humidity 50 % Moisture difference 51 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 24742 Btuh Structure 28338 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(23 cfm) 1069 Btuh Central vent(23 cfm) 509 Btuh Humidification 0 Btuh Blower Piping 0 Btuh 0 Btuh Equipment load 25811 Btuh Use manufacturer's data n Rate/swing multiplier 0.99 Infiltration Equipment sensible load 28559 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1543 Btuh Ducts 0 Btuh Heatin Coolip Central vent(23 cfm) 805 Btuh Area (fl:2) 128Y 128 Equipment latent load 2348 Btuh Volume(ft3) 11583 11583 Air changes/hour 0.45 0.23 Equipment total load 30907 Btuh Equiv.AVF(cfm) 87 44 Req. total capacity 2.5 ton Heating Equipment Summary Cooling Equipment Summary Make Trane Make Trane Trade XR 15 Weathertron Trade XR 15 Weathertron Model 4TWR5030EI Cond 4TWR503OE1 Coil TAM7AOB3OH21 Efficiency 9.5 HSPF Efficiency 15.7 EER Heating input Sensible cooling 30020 Btuh Heating output 29800 Btuh @ 470F Latent cooling 1580 Btuh Temperature rise 26 OF Total cooling 31600 Btuh Actual air flow 1027 cfm Actual air flow 1027 cfm Air flow factor 0.042 cfm/Btuh Air flow factor 0.036 cfm/Btuh Static pressure 0.00 in H20 Static pressure 0.00 in H20 Space thermostat Load sensible heat ratio 0.92 Boldlitalic values have been manually overridden Printout certified by ACCA to meet all requirements of Manual J 8th Ed. EAEDS\Current\Resident1a1 Changeout Manual AEAC, Page I