158 S Oceanwalk Dr 2013 HVAC CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 /oR Application Number . . . . . 13-00002567 Date 4/29/13 Property Address . . . . . . 158 S OCEANWALK DR Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ GYARMATHY, RAYMOND H A/C SYSTEMS OF JACKSONVILLEINC 158 OCEANWALK DRIVE S P.O. BOX 10236 ATLANTIC BEACH FL 32233 JACKSONVILLE FL 32247 (904) 858-4342 ---------------------------------------------------------------------------- Permit W/W/O MECHANICAL PERMIT Additional desc . . Permit Fee . . . . 214 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 10/26/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 3 . 21 STATE MECH DBPR SURCHARGE 3 . 21 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 214 . 00 214 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 6 . 42 6 .42 . 00 . 00 Grand Total 220 .42 220 . 42 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247-5826 Fax(904) 247-5845 JOB AiDDRESS: 158 Oceanwalk Dr. Atlantic Beach, FL 32233 PERMIT# PROJECT VALUE $5025.00 NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity_ Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION ARI #4358468 Air Conditioning: Unit Quantity Tons Per Unit 4 REQUIRED Heat: Unit Quantity BTU's Per Unit 47,000 Seer Rating 15 Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty_ Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Tanks(gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name Ray Gyarmathy Phone Number (904) 343-2387 Mechanical Company A/C Systems of Jacksonville, Inc. Office Phone 904-858-4342-Fax 904-858-4348 Co. Address: 1821 Mitchell Ave Citv Jacksonville State FL Zil) 32207 License Holder(Print): Paul G Kinser Suite Ce ification/Registration# CAC1813233 Notarized Signature of License Holder ��_ 4tf!f pr Sworn and subscribed before me th- 29th day 2013 15, 0 If THERESA A.WEISBACK Notafy PubliC-St3leof Florida Signature of Notary Public C:Ommisslon#EE 4AS95 My Commission E W Bonded Thru PichardINMi0tance Load Short Form Job: + wrightsoft Date: Apr 29,2013 Entire House By: A/C Systems of Jacksonville Inc. 1821 Mitchell Ave,Jad(sonville,FL 32207 Phonei 904-858-4342 Fax:904-858-4348 Ernail:acsysiax@yahoo.com License:CAC1 81813233 Project Information For: Ray Gyarmathy 158 Oceanwalk Dr, Atlantic Beach, FL 32233 Design Information Htg Cig Infiltration Outside db ('F) 39 92 Method Simplified Inside db ('F) 68 75 Construction quality Average Design TD ('F) 29 17 Fireplaces 0 Daily range - L Inside humidity(%) 50 50 Moisture difference (gr/lb) 23 58 HEATING EQUIPMENT COOLING EQUIPMENT Make Amana Make Amana Trade Amana Trade Amana Model ASZ140481A Cond ASZ140481A AHRI ref 4358468 Coil ASPF426016E AHRI ref 4358468 Eff iciency 8.8 HSPF Eff iciency 15 SEER Heating input Sensible cooling 0 Btuh Heating output 0 Btuh @ 47'F Latent cooling 0 Btuh Temperature rise 0 'F Total cooling 0 Btuh Actual air flow 1600 cfm Actual air flow 1600 cfm Air flow factor 0.071 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0.08 in H20 Static pressure 0.08 in H20 Space thermostat Load sensible heat ratio 0.94 ROOM NAME Area Htgload CIg load Htg AVF CIg AVF (w) (Btuh) (Btuh) (cfm) (cfm) Room3 3481 22403 35232 1600 1600 Entire House 3481 22403 35232 1600 1600 Other equip loads 0 0 Equip. @ 0.97 RSM 34175 Latent cooling 2408 TOTALS 3481 22403 36584 1600 1600 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 2013-Apr-29 1520:55 + wrightSOft Rig ht-Su itee Universal 2012 12 1.05 RSU 18387 Page 1 ACC$, YAEnergy Load caiculatons\GYARMATHY.rup Calc=MJ8 FrontDoorfaces: N Job: Building Analysis Date: Apr 29,2013 + wrightsoft Entire House By: A/C Systems of Jacksonville Inc. 1821 Mitchell Ave,Jacksonville,FL32207 Phone�904-858-4342 Fax:904-858-4348 Eniail:acsAax@yahoo.com License�CAC`181813233 Project Information For: Ra lyxmath� 159 Oceanwal Dr., Atlantic Beach, FL 32233 Design Conditions Indoor: Heating Cooling Location: 68 75 Jacksonville Mayport Naval, FL, US Indoor temperature ('F) Elevation: 16 ft Design TD ('F) 29 17 Latitude: 30'N Relative humidity 50 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 23.0 58.2 Dry bulb ('F) 39 92 Infiltration: Daily range (oF) - 15 L Method Simplified Wet bulb ('F) - 78 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Heating Component Btuh/ft2 Btuh % of load Walls 2.2 3165 14.1 Glazing 16.5 9918 44.3 Doors 11.3 950 4.2 Ceilings 0.9 3230 14.4 Floors 0.4 1514 6.8 Infiltration 2.2 3625 16.2 Ducts 0 0 Piping 0 0 GWM Humidification 0 0 Ventilation 0 0 Adjustments 0 Total 224031 100.0 Cooling Component Btuh/ft2 Btuh % of load Walls 0.9 1265 3.6 Glazing 42.9 25764 73.1 Doors 12.0 1011 2.9 Ceilings 1.7 6054 17.2 Floors 0 0 0 Infiltration 0.7 1138 3.2 Ducts 0 0 Ventilation 0 0 Internal gains 0 0 Blower 0 0 Adjustments 0 —Tota.1 1 352321 100.01 Latent Cooling Load 2408 Btuh Overall U-value= 0.069 Btuh/ft2-'F Data entries checked. 2013-Apr-29 1520:55 wrightSOft Right-SurteG universal 2012 12.1.05 RSU18387 Page 1 AC-Ck Y:\Energy Load Calculabons\GYARMATHY.rup Calc=MJ8 FrontDoorfaces: N Component Constructions Job: wrightsoft' Date: Apr 29,2013 Entire House By: A/C Systems of Jacksonville Inc. 1821 Mitchell Ave,Jacksonville,FL 32207 Phone:904-858-4342 Fax:904-858-4348 Email:acsysjax@yahoo.com License:CAC1 81813233 Project Information For Ray Gyarmathy 158 Oceanwalk Dr., Atlantic Beach, FL 32233 Design Conditions Location: Indoor: Heating Cooling Jacksonville Mayport Naval, FL, US Indoor temperature(OF) 68 75 Elevation: 16 ft Design TD (OF) 29 17 Latitude: 30'N Relative humidity 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 23.0 58.2 Dry bulb(OF) 39 92 Infiltration: Daily range(OF) - 15 L Method Simplified Wet bulb(OF) - 78 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area Ll-value Insul R Htg HTM Loss Cig HTM Gain fF BWW-*F ft2-*FA3hh l3bihff Btuh BUM Walls 15B-10sfo-2:Bg wall,light dry soil,brick wall,r-10 ins,8"thk n 383 0.061 10.0 2.21 847 0.90 346 e 349 0.061 10.0 2.19 765 0.87 302 s 371 0.061 10.0 2.20 818 0.89 331 w 337 0.061 10.0 2.18 736 0.85 286 all 1440 0.061 10.0 2.20 3165 0.88 1265 Partitions (none) Windows 1 D-c2ow:2 glazing,dr outr,air gas,wd frm mat,dr innr, 1/4"gap, n 148 0.570 0 16.5 2446 21.3 3153 1/4"thk e 140 0.570 0 16.5 2314 63.4 8877 s 160 0.570 0 16.5 2645 25.6 4096 w 152 0.570 0 16.5 2513 63.4 9637 all 600 0.570 0 16.5 9918 42.9 25764 Doors 11 DO:Door,wd se type e 42 0.390 0 11.3 475 12.0 505 w 42 0.390 0 11.3 475 12.0 505 all 84 0.390 0 11.3 950 12.0 1011 Ceilings 16B-30ad:Attic ceiling,asphalt shingles roof mat,r-20 roof ins,r-30 3481 0.032 30.0 0.93 3230 1.74 6054 ceil ins Floors 21B-28t:Bg floor,light dry soil,prm int ins cov,6.5'depth,r-3 ins,tile 3481 0.015 3.0 0.44 1514 0 0 fir fnsh 2013-Apr-29 15:20:55 wrightsoft' Rght-SuiteOL)niversal2Ol2l2.1.05RSU18387 Page 1 ACCK Y.-Energy Load Calculabons\GYARMATHY.rup Calc=MJ8 FrontDoorfaoes: N Job: + wrightsoft Project Summary Date: Apr29,2013 Entire House By: A/C Systems of Jacksonville Inc. 1821 Mitchell Ave,JacksonAlle,FL 32207 Phonei 904-858-4342 Fax:904-858-4348 Email:acsysjax@yahoo.com Liceensei CAC1 81813233 Project Information For: Ray Gyarmathy 158 Oceanwalk Dr, Atlantic Beach, FIL 32233 Notes: Design Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 'F Outside db 92 'F Inside db 68 'F Inside db 75 'F Design TD 29 'F Design TD 17 oF Daily range L Relative humidity 50 % Moisture difference 58 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 22403 Btuh Structure 35232 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 22403 Btuh Use manufacturer's data n Rate/swing multiplier 0.97 Infiltration Equipment sensible load 34175 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2408 Btuh Ducts 0 Btuh Heatin Coolin Central vent (0 cfm) 0 Btuh Area (ft2) 3489 348q Equipment latent load 2408 Btuh Volume(ft') 24367 24367 Air changes/hour 0.28 0.15 Equipment total load 36584 Btuh Equiv.AVF (cfm) 114 61 Req. total capacity at 0.70 SHR 4.1 ton Heating Equipment Summary Cooling Equipment Summary Make Amana Make Amana Trade Amana Trade Amana Model ASZ140481A Cond ASZ140481A AHRI ref 4358468 Coil ASPF426016E AHRI ref 4358468 Eff iciency 8.8 HSPF Eff iciency 15 SEER Heating input Sensible cooling 0 Btuh Heating output 0 Btuh @ 470F Latent cooling 0 Btuh Temperature rise 0 -1- Total cooling 0 Btuh Actual air flow 1600 cfm Actual air flow 1600 cfm Air flow factor 0.071 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0.08 in H20 Static pressure 0.08 in H20 Space thermostat Load sensible heat ratio 0.94 Calculati ons approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-Apr-29 15:20 55 12t:_ + wrightSOft Right-SuiteO Universal 2012 12.1.05 RSU1 8387 Page 1 Y:\Energy Load Calculatons\GYARMATHY.rup caic=MJ8 FrontDoorfaces: N Job: + wrightsoft AED Assessment Date: Apr29,2013 Entire House By: A/C Systems of Jacksonville Inc. 1821 Mitchell Ave,Jacksonville,FL 32207 Phone:904-858-4342 Faxi 904-858-4348 Email:acsysjax@yahoo.com License:CAC1 81813233 Project Information For: Ray Gyarmathy 158 Oceanwalk Dr, Atlantic Beach, FIL 32233 Design Conditions Location: Indoor: Heating Cooling Jacksonville Mayport Naval, FL, US Indoor temperature (T) 68 75 Elevation: 16 ft Design TD (T) 29 17 Latitude: 30'N Relative humidity 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 23.0 58.2 Dry bulb (oF) 39 92 Infiltration: Daily range (T) - 15 ( L Wet bulb (T) - 78 Wind speed (mph) 15.0 7.5 Test for Adequate Exposure Diversity Hourly Glazing Load 35,000-- 30,000-- 25,000-- 20,000-- 0 15,000-- 10,000-- 5,000-- 0 8 9 10 11 12 13 14 15 16 17 18 19 20 Hour of Day .'e Hourly /Average AED firr�ft Maximum hourly glazing load exceeds average by 19.6%. House has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 13tuh 2013-Apr-29 15:20:55 + wrightSOft Right-suitee Universal 2012 12.1,05 RSU18387 Page 1 ACCN YAEnergy Load Calculabons\GYARMATHY.rup Calc=MJ8 Front Door faces:N + wrightsoft Right-JO Worksheet Job: Date: Apr 29,2013 Entire House By: A/C Systems of Jacksonville Inc. 1821 Mitchell Ave,Jacksonville,FIL 32207 Phone:904-858-4342 Faxi 904-858-4348 Email:acsysjax@yahoo.00m License CAC1 81813233 1 Room name Entire House Room3 2 Exposed wall 236.0 ft 236.0 ft 3 Room height 9.0 ft 9�0 ft heat/cool 4 Room dimensions 3481 0 ft2 3481.0 ft2 59.0 x 59.0 ft 5 Room area Ty Construction U-value Or HTM Area (ft� Load Area .M Load number (Btuh/ft'-'F) (Btuh/ft) or perimeter (ft) (Btuh) or perimeter (ft) (Bt h) Heat I Cool Gross N/P/S H eat I Cool Gross N/P/S Heat I Cool 6 W 15B-10sfb-2 0.083 n Z21 0.90 531 383 847 346 531 383 B47 346 L—G 1 D-c2ow 0.570 n 16.53 21.31 148 0 2446 3153 148 0 2446 3153 W 15B-10sfb-2 0.083 e 2.19 0.87 531 349 765 302 531 349 765 302 1 L2 D-c2ow 0.570 e 16.53 63.40 140 0 2314 8877 140 0 2314 8877 111DO 0.390 e 11.31 12.03 42 42 475 505 42 42 475 505 5B-10sfb-2 0.083 s 2.20 0.89 531 371 818 331 531 371 818 331 t--G I D-c2ow 0570 s 16.53 25.60 160 0 2645 4096 160 0 2645 4096 W 15B-10sfb-2 0.083 w Z 18 0.85 531 337 736 286 531 337 736 286 IjD-c2ow 0.570 w 16.53 63�40 152 0 2513 9637 152 0 2513 9637 111 DO 0.390 w 11.31 12.03 42 42 475 505 42 42 475 505 C 1613-30ad 0.032 &93 1.74 3.481 3481 3230 6054 3481 3481 3230 6054 F 21 B-28t 0015 0.44 0�00 3481 3481 1514 0 3481 3481 1514 0 6 c)AED excursion 0--- 0 18778 34094 18778 34094 Envelope loss/gain — 12 a) Infiltration 3625 1138 3625 1138 b) Room ventilation 0 0 0 0 13 Internal gainsi Occupants @ 230 0 0 0 0 Appliances/other 0. -- 0 Subtotal(lines 6 to 13) 22403 352321 22403 35232 Less external load 0 0 0 0 0 0 0 0 Less transfer 0 0 Redistribution 0 0 2 Subtotal 0 0 -0% 0%, 01 0 14 22403 3523 22403 35232 151 Duct loads 0% 0% Total room load 22403 35232 22403 35232 1600 1600 16001 1600 Air required(cfm) I I I I I I Calculations approved bVACCA to meet all requirements of Manual J 8th Ed. 2013-Apr-29 1520:55 -f+F vvrightsc)ft Right-SuiteO Universal 2012 121.05 RSU18387 Pagel AC(Z-" YAEnergy Load Calculations\GYARMATHY.rup CaIc=MJ8 FrontDoorfaces: N Job: + wrightsoft Loads for Multiple Orientations Date: Apr 29,2013 Entire House By: A/C Systems of Jacksonville Inc. 1821 Mitchell Ave,Jacksonville,FL 32207 Phone�904-858-4342 Fax:904-858-4348 Email:acsysjax@yahoo.com License:CACI 8 181 3233_ — Project Information For: Ray Gyarmathy 158 Ciceanwalk Dr.I Atlantic Beach, FIL 32233 Design Conditions Location: Indoor: Heating Cooling Jacksonville Mayport Naval, FL, US Indoor temperature ('F) 68 75 Elevation: 16 ft Design TD ('F) 29 17 Latitud& 30'N Relative humidity 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 23.0 58.2 Dry bulb ('F) 39 92 Infiltration: Daily range('F) - 15 ( L Wet bulb ('F) - 78 Wind speed (mph) 15.0 7.5 Front Door North Northeast East Southeast South Southwest West Northwest Sensible Load (Btuh) 34175 37335 34745 37306 34125 37335 34795 37364 Latent Load (Btuh) 2408 2408 2408 2408 2408 2408 2408 2408 Total Load (Btuh) 36584 39744 37154 39715 36534 39744 37204 39772 Heating AVF (cfm) 1600 1600 1600 1600 1600 1600 1600 1600 Cooling AVF (cfm) 1600 1600 1600 1600 1600 1600 1600 1600 Building Orientation Cooling Load 30000 M 0 -J 0) 20000 0 0 7� "6 10000 0 N NE E SE S Sw W NW Direction Front Door faces Current Cirientation� Front Door faces North Highest Cooling Loa& Front Door faces Northwest Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-Apr-29 15:2055 lzt:� + wrightSOft Right-Suite@ Universal 2012 12.1.05 RSU18387 Page 1 ,4C01, YAEnergy Load Calculabons\GYARMATHY.rup Calc=MJ8 Front Door faces:N