336 10th St 2013 HVAC v CITY OF ATLANTIC BEACH s 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00002573 Date 4/30/13 Property Address . . . . . . 336 10TH ST Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . RES SF DISTRICT Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 4ton unit, 48K btu' s ---------------------------------------------------------------------------- Owner Contractor - ------------------------ ----------------------- BULL KATHLEEN & NIELS ONE HOUR AIR 336 10TH ST 1015 ATLANTIC BLVD #249 ATLANTIC BEACH FL 322335530 ATLANTIC BEACH FL 32233 (904) 222-8482 ---------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . 83 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 10/27/13 ------------------------------------------------------------------ Other Fees . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ------ Permit Fee Total 83 . 00 83 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 87 . 00 87 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(9044)-247-5826 Fax (904) 247-5845 JoB ADDRESS: `j� 6T J 1 ��� PERMIT# PROJECT VALUE $ REQUIRED NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit e- Heat: Unit Quantity BTU's Per Unit ( Seer Rating Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name &kL- A U L L Phone Number Z I Mechanical Company ��t l Uv- n!r-�, Office Phon I- 16 Fax 2�l?-S� 2� Co. Address: 1 �8 V►�l `�� '�PI-) City SIC 'l State =Zip 72237 License Holder (Print): Cgol L [o�� State Certification/Registration#C*C&4q-2o Notarized Signature of License Holder Before me this day of 20 Signature of Notary Public Job: 122739 Project Summary Date: 4/3012013 wrightsoft Entire House By: CRAIG EDDY ONE HOUR AIR 1198 MAYPORT RD#1,ATLANTIC BEACH,FL 32233 Phone:904-241-3107 Fax:904-247-5526 License:CAC1814420 UNT-TRINOMMM For: NIELS &KATHY BULL 336 10TH STREET, ATLANTIC BEACH, FL 32233 Phone: 904-249-1345 Notes: Weather: Jacksonville/Craig, FL, US Winter Design Conditions Summer Design Conditions 35 °F Outside db 91 °F Outside db 70 °F Inside db 75 °F Inside db 16 °F Design TD 35 °F Design TD M Daily range 50 Relative humidity 53 gr/lb Moisture difference g Heating Summary Sensible Cooling Equipment Load Sizing 41571 Btuh Structure 37181 Btuh Structure 0 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Blower 0 Btuh Humidification 0 Btuh Piping Equipment load 41571 Btuh Use manufacturer's data 1.00y Rate/swing multiplier 37 .0 Btuh Infiltration Equipment sensible load Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average 4781 Btuh Fireplaces 0 Structure 0 Btuh Ducts 0 Btuh Heating Cooling Central vent(0 cfm) Area(ftp 2112 2112 Equipment latent load 4781 Btuh Volume(if) (cfm)hour 2534 0 44 2534 0.214 Equipment total load 41962 Btuh Equiv.AVF ( Air changes173 89 Req. total capacity at 0.78 SHR 4.0 ton Heating Equipment Summary Cooling Equipment Summary Make GOODMAN Make GOODMAN Trade AMANA Trade AMANA Model ASZC180481 Cond ASZC180481 AHRI ref 4612963 Coil CHPF4960 AHRI ref 4612963 18 SEER Efficiency 0 HSPF Efficiency 37392 Btuh Heating input Sensible cooling 10608 Btuh 0 Heating output 0 'F @ 47°F Latent cooling 48000 Btuh fm Actual air flow Temperature rise cTotal cooling 1693 cfm Actual air flow 1693 cf0.046 cfm/Btuh Air flow factor 0.041 cfm/Btuh Air flow factor 0 in H2O Static pressure 0 in H2O Static pressure 0 89 Space thermostat Load sensible heat ratio Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-Apr-30 08:53:02 wl-igfltsoftRight-SuiteO universal 2012 12.1.07 Right JOO Mobile Page 1 ACOA. ...\wstmp\e735c284-1150-4096-be6e-bd78394acbfa.rup Calc=MJ8 Front Door faces: N